Arterial Puncture Wrist. Instruction Manual

Similar documents
Arterial Puncture Wrist

CVC Insertion Simulator

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Peripheral Venous Catheter Placement Simulator

Ultrasound Guided Thoracentesis Simulator

M58 Newborn Vital Signs Examination Simulator. Instruction Manual

Difficult Airway Management Simulator

Ultrasound Guided Thoracentesis / Pericardiocentesis Simulator Full set

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

UPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL

Parts identification:

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

Med Aire Alternating Pressure Pump and Pad System

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

SILENTAIRE TECHNOLOGY

Difficult Airway Management Simulator Assessment System

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

M192. Enema Administration Simulator 2. User s Manual (151218) Introduction/Table of Contents 1 Purpose/Content 2 Cautions concerning handling 3-4

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Bleeding Trauma Module Set. Directions for Use

Lung Sound Auscultation Trainer LSAT

Central Venous Catheter Insertion Training Simulator Introduction for CVC Training with Simulator

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AT Kelly Torso. Directions for Use

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

SILENTAIRE TECHNOLOGY

Pressure Injection Cell Operator s Manual

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

Front derailleur. Dealer's Manual DURA-ACE FD-R9100 ULTEGRA FD-R FD ROAD MTB Trekking. City Touring/ Comfort Bike DM-RAFD001-03

QUIK-jet Micro-Injection System

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Budget Range Operators Handbook

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

Port - Body in a Box User s Manual

Installation Instructions

ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO PORTUGUÊS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

accidents which arise due to non-observance of these instructions and the safety information herein.

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

BMR 2100XL Operating Instructions Page 1 of 13

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Easy Nest Kits. Installation Suggestions

User's Manual. MixRite TF 10. Edition 05.08

Natural Gas Conversion Kit

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

12V MINI AIR COMPRESSOR

Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH.

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Pressure Dump Valve Service Kit for Series 2300 Units

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Installation Instructions

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Instruction Manual for Configura Cushionair Portable Pump

BELT DRIVE PREMIUM INDOOR CYCLING BIKE SF-B1509 USER MANUAL

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

VERTICAL AIR COMPRESSORS

CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL

Techcon Systems TS1254 Pressure Pot

Installation of Your SprayMaster System

INSTRUCTION MANUAL Elisa Baby-PICC

MODEL 1329 Tank Gauge

VERTICAL AIR COMPRESSORS

ANTARES. User Manual ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH. Photo: Jonas Andersson, Lysekil

Welcome to the Specialized Medical Services Respiratory training webinar series!

Instruction Manual. Instruction Manual. Manufactured by G&G Armament 100% Made in Taiwan

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

HPB25 Hydraulic Paving Breaker

USER MANUAL

NOTES BEFORE USE BE SURE TO READ THIS MANUAL BEFORE USING THE HELMET. KEEP THE MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Inflatable Dock Slide Owner s Manual

Metric Porcelain Enamel Powder Pump

R E D I C O N T R O L S

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

MB-SP Series Solvent Purification System

Portable Oil Lube Air Compressors

Techcon Systems TS1258 Pressure Pot

MAGNETIC INDOOR CYCLING BIKE

Nita Newborn Model 1800 User Manual

Alternating Pressure / Low Air Loss Mattress System

SM Models Manual Control

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Transcription:

Arterial Puncture Wrist Instruction Manual

Production supervision Dr. Hiroshi Koyama National Hospital Organization Kyoto Medical Center

ENGLISH Index Features Components Before training While training After training Troubleshooting DOs & DON'Ts Replacement parts P. P.2 P.3~P.6 P.7 P.7~P.9 P.0 P. P. Features A life-like simulator for artery puncture practices for arterial blood collection procedures. Realistic pulsation and flash-back facilitate the training. The simulator is designed for training in artery puncture and blood collection. Do not use for improper purpose. Please read the instruction carefully before use. 2 3 4 5 6 7 Radial artery pulse is palpable. Anatomically correct artery location. Realistic resistance of tissue and artery wall felt through the needle. Natural flashback of arterial blood can be observed. Puncture skin and artery tube are replaceable. No needle marks remain. One-touch connection.

Components Set includes b a c d f f i e h g j a.puncture unit Skin (outer) 2Skin (inner) 3Artery tube 4Silicon tape 5Radius base b.hand-wrist model c.simulator Base d.circulation pump e.blood powder f.jar g.spoon h.connection tube (black ring) i.connection tube (red ring) j.vinyl sheet 2 2 4 2 a 3 2 4 2 5 The operation environment for the circulation pump. Environmental conditions : 0 degrees C. - 40 degrees C. Relative humidity : Less than 80 per cent (no condensation) Working environment : Indoor or place considered to be close to indoor Avoid exposure to the elements Altitude : 2000 meters above sea-level Installation category : Ⅱ (2) Pollution degree : Ⅱ (2) Supply voltage : AC 00V-240V~ 0.6A 50/60Hz 2

Before training Please note: We recommend perform the preparation and training on the included vinyl sheet. Parts name and functions Puncture unit Hand-wrist model Suction tube Discharge tube Drain tube Jar Jar holder Adjustment knob (pulse strength) Power switch Tube socket (In) Tube socket (Out) Preparation of simulated blood Take blood powder with the tip of the small spoon. (approx. /8 spoon) 2 Dissolve it in 4/5 jar of water. (approx. 60cc, 0-40 degrees C) 3 Place the jar on the jar holder at the back side of the simulator base. Tube socket (IN) Tube socket (OUT) 4 Insert the suction/discharge tubes into the simulated blood. Make sure the tips of the both tubes are properly placed undersurface of the fluid. The tip of the drain tube is to be above the surface. drain tube PLEASE NOTE: The solution is not designed for prolonged storage. Please prepare new simulated blood for each session. 3

2 Connection of the circulation pump Connect the simulator base and circulation pump with tubes. Simulator base Circulation pump Push the tube toward the wall until click sound heard. Push the tube toward the wall until click sound heard. Connect the simulator base and circulation pump with tubes. Insert the ends of connection tube to the tube sockets on the circulation pump and simulator base so that the sockets marked with same color sign are properly connected. Base In(gray) Out (red) tubes Out(gray) In (red) Pump Disconnection of the tubes Push Hold this part. Hold the metal sleeve on the tube socket and push it toward the pump/simulator base wall to unlock the connection. Caution: Do not disconnect the tubes while the simulator is running. Before disconnect the tubes, make sure to discharge all fluid from the pump and tubes, and switch the power off. Do not pull the tube by holding the vinyl tube. Otherwise, the tube may come off from the connector. 4

3 Setting up the wrist model and puncture unit Put the silicon tape on the radius base. Insert one end of the silicon tape to one of the slits on the radius base edge so as that the knot comes to the underside. Silicon tape Radius base Knot 差し込む Pulling the silicon tape, place it in the gutter on the base and fix it by inserting the other end into the slit on the opposite side. Make sure not to twist the tape. Put the radius base mounted with the silicon tape to the simulator base, noting that the tape and notch on the simulator base come on the same line. come on the same line Please note; the silicon tape is replaceable. 2Put the artery tube Connect the white connecter at the end of artery tube to the white socket on the simulator base. Lock each connection by turning the socket clock with until it clicks. Please note; if the lock is incomplete, the tube may come off and simulated blood may leak. 5

Putting the tube in the gutter on the radius base, connect the other end of the tube to the black socket and lock it by turning clockwise until it clicks. 3Put the skin cover Please note; if the lock is incomplete, the tube may come off and simulated blood may leak. Cover the radius base by the inner skin cover, noting the direction so that the artery tube is properly inserted in the slits on the walls of the skin cover. Likewise, cover the puncture area by outer skin cover. Make sure the all edges of the skin cover are properly placed in the walls of the puncture unit holder. Please note; make sure that the artery tube is properly placed in the slits on the skin cover without being flatted. 4Set up the hand-wrist model. Put the hand-wrist model on the simulator base. Be careful not to catch the artery tube in between. 6

4 While training Put the power plug to the power supply. 2 Switch on the circulation pump and let the simulated blood fill the tube. Now the simulator is ready for practice. 3 When the pulse is too weak, it can be adjusted by turning adjustment knob on the simulator base. weak strong (Pressure is set at the appropriate strength by the manufacturer at the time of shipping). To make the pulse stronger, turn the knob clockwise. Please note; Excessive force may cause breakage to the knob. Please handle it with care. 4 When the simulated blood in the jar runs short by blood collection training, add some new fluid (or you can return the collected fluid to the jar). 5 After training Discharge the simulated blood from the system. Lift the suction tube so that the end of the tube comes above the fluid surface, and run the circulation pump until the all fluid in the tubes is flow out into the jar. suction tube Please note; Be careful so that the end of the tube is always inside the jar wall. 2 Replace the jar of the simulated blood with another jar filled with clear water. Put the tips of suction and discharge tubes into the water and run the circulation pump until the inside of the tubes are cleaned. 3 Discharge the water from the simulator following the procedure of discharging simulated blood. 4 When the hand-wrist model is stained, wipe off by cloth or wash by water. 7

6 Disassembly of the hand-wrist model and puncture unit Take off the hand-wrist model Lift Holding the puncture unit by one hand, lift the back of the hand-wrist model and take it off from the simulator base. 2Remove the skin covers Take off the outer and inner skin covers one by one. Be careful not to pull them too strong, since excessive force may cause tear(s). 3Disconnect the artery tube Unlock the each connector by turning counterclockwise until it clicks and pull it straight off. Caution: Do not pull the artery tube or any parts by excessive force. Otherwise it may cause breakage in the simulator. 8

4Take off the radius base 7 Cleaning The skin covers Wipe off the simulated blood inside the skin covers by soft cloth. 2The simulator base Wipe off the simulated blood on the simulator base, especially around the puncture unit holder, by soft cloth. 3Outside of the circulation pump Wipe the surface of the circulation pump by cloth wrung out of water. Caution: Do not use any organic solvent or alcohol to any parts of the simulator. When the simulator gets heavily stained, use soap or neutral detergent. 4Inside of the circulation pump We recommend washing up the inside of the pump once in a while. This procedure is to be done before disassembling the unit. ) Stop the circulation pump. OUT 2) Disconnect the tube connector marked 'OUT' (red) on the simulator base. 3) Fill the syringe with clear water and connect the syringe tip to the free end of the tube. 4) Inject the water to the tube until the injected water flow in to the jar. (approx. 20cc.) 5) Connect the tube back to the simulator base and discharge water by following the instruction on page 7. 9

Troubleshooting Quick check-up before calling the customer service Use the table if you have problems using the system. Look in this section for a description of the problem to find a possible solution. Trouble Possible Reason What to Do The system cannot be powered on. (Circulation pump does not run) Circulation pump runs but simulated blood does not flow. Flash-back of the simulated blood is not seen. The simulated blood heavily leaks from around the puncture unit. Bubbles appear in the simulated blood in the tubes. Power plug is not properly connected to the power source. Power switch is cut off. Power does not come to the outlet. Built-in fuse is blown out. Connection of the tubes is wrong. Connection tube(s) between the pump and simulator base is folded. The pulse pressure is too strong (too tight). Valves or other inner parts of the pump are adhered to by extraneous matter. The artery tube is worn out. Simulated blood is not flowing. Syringe is worn or the needle is clogged. The pulse pressure is too weak. Skin covers are not set properly. The artery tube and/or skin covers are worn out. The pulse pressure is too strong. The pump is sucking the bubbles coming from the discharge tube. The artery tube is worn out. Air is collected in the circulation pump. Connect to the power source. Switch it on. Check the breaker., etc. Contact the customer service. Change the connection following the instruction manual. Straighten the tube(s). Loosen the adjustment knob by turning counter-clockwise. Stop the circulation pump and push in water by syringe (see page 9, #4). Replace it with a new artery tube. Check the flow. Replace them with new syringe and needle. Adjust it by turning the adjustment knob clockwise. Set the cover again following the instruction manual. Replace it/them by new one(s). Adjust it by turning the adjustment knob counter-clockwise. Make a little distance between the ends of suction and discharge tubes. Replace it with a new tube. Discharge the air by tilting the pump as shown by the illustration. Simulated blood leaks from the simulator base or pump. None of above is the case. Tube sockets are not properly locked. The end of the drain tube is contacting with the fluid in the jar. Make the pulse pressure weak (tuning the knob counter -clockwise), and run the pump until the bubbles come off. Then return the pulse pressure to appropriate strength. Check the sockets and lock them. Lift the drain tube and push it back toward the simulator base so as not to touch the fluid. 0

DOs and DO'NTs DOs Handle with care The materials for the models are special compositions of soft resin. Please handle them with utmost care at all times. Storage After use, wipe off all the fluid completely from the simulator and powder the soft parts (hand-wrist model and skin covers)with talcum powder. Store the simulator set at room temperature, away from heat, moisture and direct sunlight. Keep clearance For safety reason, always keep the appropriate clearance around the circulation pump while running the system so as to allow the operator to unplug the power supply in case of system malfunction. DON Ts Do not use a curved or broken needle for practice. Never wipe the models and pads with alcohol, thinner or any organic solvent. Don t mark on the simulator with pen or leave any printed materials in contact with simulator surface. Ink marks on the models won't be removable. Do not keep running the system continuously more than 2 hours. Take at least 0 minutes interval every 2 hours. Note; The color of the tube or soft resin parts may change after long use/storage, but this cause no problem in use of the simulator. Replacement parts Parts name Quantity Product code Skin covers Silicon tape Artery tube A set of two (each one of outer and inner skin) A set of four A set of four 35-00 35-030 35-040 Blood powder (for simulated blood) A bottle (30g) 266-080 For inquiries and service, please contact your distributor or: KYOTO KAGAKU CO., LTD. Main Office and Factory 5 Kitanekoya-cho Fushimi-ku Kyoto 62-8388, Japan Telephone : 8-75-605-250 Facsimile : 8-75-605-259 LA Office ( for USA and CANADA customers ) 309 Lomita Boulevard, Torrance, CA 90505,USA Telephone : -30-325-8860 Facsimile : -30-325-8867 http://www.kyotokagaku.com rw-kyoto@kyotokagaku.co.jp

Main Office and Factory 5 Kitanekoya-cho Fushimi-ku Kyoto 62-8388, Japan Telephone : 8-75-605-250 Facsimile : 8-75-605-259 LA Office ( for USA and CANADA customers ) 309 Lomita Boulevard, Torrance, CA 90505,USA Telephone : -30-325-8860 Facsimile : -30-325-8867 07.0.0 http://www.kyotokagaku.com rw-kyoto@kyotokagaku.co.jp