Series K Clean one-touch fittings For blowing Recommended applicable olyolefin: Series T Tubing material Soft polyolefin: Series TS Tubing O.D. ø, ø, ø, ø, ø olyurethane Series TU, Nylon Series T, and Soft nylon Series TS can also be used. owever, the degree of cleanliness will decline. Note 2) Due to the softness of polyurethane, it may fold when being inserted. old the end of the and insert it all the way in. Refer to "Installation and Removal of Tubing". Specifications article generation grade Grade 1 (Refer to front matter pages to for details.) Fluid ir, Nitrogen gas, Water (ure water) aximum operating pressure (20 C) 1 a Note 2) Operating vacuum pressure 0 ka roof pressure (20 C) 3 a mbient and fluid temperature 20 C to 0 C Threads JIS B0203 (Taper thread for piping) Consult SC regarding other fluids. Note 2) The maximum operating pressure is the value at 20 C. Refer to the operating pressure curve for other temperatures. rincipal parts material Body Stud Chuck Guide, Stopper, Drive bushing Collet, Release button Seal, O-ring, Bumper olypropylene resin olypropylene resin Stainless steel 30 Stainless steel 30 olypropylene resin ED Series K is a line of special one-touch fittings for use in clean room blowing and washing lines. lease consult with SC regarding other types of applications. Seal material: The durability of ED with respect to mineral oils is inferior, which makes it unsuitable for piping in general pneumatic. Relationship between operating temperature and maximum operating pressure 1.2 aximum operating pressure a 1.0 0. 0. 0. 0.2 0 20 0 20 0 0 0 Operating temperature C 0
Dimensions ale connector: K ale elbow: K O.D.(mm) ale branch tee: KT ale run tee: KY 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ ale branch Y : KU 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ odel K0-01. K0-02. 1 K0-01 1. K0-02 2. 20. K0-01 32.3 2. K0-02 30.3 2. K-02 3. 32 1 K-03 33 2 2 K-03 3 2 K-0 3. 2 odel K0-01 K0-02 K0-01 K0-02 K0-01 K0-02 K-02 K-03 K-03 K-0 odel KT0-01 KT0-02 KT0-01 KT0-02 KT0-01 KT0-02 KT-02 KT-03 KT-03 KT-0 odel KY0-01 KY0-02 KY0-01 KY0-02 KY0-01 KY0-02 KY-02 KY-03 KY-03 KY-0 odel KU0-01 KU0-02 KU0-01 KU0-02 KU0-01 KU0-02 KU-02 KU-03 KU-03 KU-0 1 1 1 1 1 1 1 1 1.. 1. 1.. 1. 1.. 1... 1. 2 2 2 Clean one-touch fittings K 3 2 1 1 2... 2.. 1.3... 2. 1 20.. 2.3 2. 31. 1 20.. 2.3 2. 31.. 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 2. 2. 2 2 30 31. 3. 3. 3. 1. 2. 2. 2 2 30 31. 3. 3. 3. 1. 1. 3... 2.. 1. 3.. 1 1 2 1 2 3. 3. 3 0 1 0.1.1 2.3 0..2 1.2 2.2.. 1 1 1 1 indicates the maximum diameter. 20 2 2 1 indicates the maximum diameter. 1 20.. 2.3 2. 31. 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 0 2 3. 0.. 2. 1.. 1 23 2 30. 1 1 1. 2 2 0 2 0 0 0 3 0 indicates the maximum diameter. 2 2 1 20 2 1 indicates the maximum diameter. 2 2 2 1 1 1 2-2 1 2 2 1 1 2-1 1 1 1 2- ir cylinder Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter 0
Clean one-touch fittings K Dimensions Straight union: K Elbow: K Union tee: KT Union Y : KU lug-in reducer: KR lug: K odel K0-00 K0-00 K0-00 K-00 K-00 odel K0-00 K0-00 K0-00 K-00 K-00 odel KT0-00 KT0-00 KT0-00 KT-00 KT-00.. 1... 1... 1. fitting size ød odel KR0-0. KR0-0 KR0-0. KR0- KR0- KR0- KR- 1. fitting size ød odel KU0-00 KU0-00 KU0-00 KU-00 KU-00 odel K-0 K-0 K-0 K- K-.. 1. 1 1 3. 2.1..2 3. 3... 0. 20.. 2.3 2. 31. 20.. 2.3 2. 31. 3. 1. 2. 0. 2 20.. 2. 30. 32. 1 2 1 2 1 2 1 1 indicates the maximum diameter. 3. 3. 1 3 0 0..3.. 1 2 3 1 20 indicates the maximum diameter. 2 1 1 2..3.. 1 2 1 2 indicates the maximum diameter. 20.1 3 1 20.2 20..2 2 1. 2 1 2 indicates the maximum diameter. 32 3 3 3.. 1..3 1.2 20. 2 1 1 2 0. 0. 1.1 1. 2... 1.... 1.1 1.1 1 2 2 32 indicates the maximum diameter. ød 2-1 ø 2 ø ø.2 ø 2- ø.2 ød 3- ø.2 3- fitting size ød fitting size ød 0
Clean one-touch fittings K Specific product precautions 1 Be sure to read before handling. ir cylinder Installation of threads Be sure to wrap sealing tape around the taper threads for resin thread. If used without sealing tape air leakage can occur. 1. Series K (with resin thread) 1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. 2) Tightening fter tightening by hand, tighten an additional 2 to 3 turns using a tightening tool. 2. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. osition the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. Installation and removal of 1. Installation of 1) Using tube cutters TK-1, 2 or 3, take a tube having no flaws on its periphery and cut it off at a right angle. Do not use pinchers, nippers or scissors, etc. The might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. 2) old the tube and push it in slowly, inserting it securely all the way into the fitting. 3) fter inserting the, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, problems such as leakage or disconnection of the can occur. ) Grease is not used due to the Series K oil-free specifications. For this reason, greater insertion force is required when is installed. In particular, polyurethane may fold when inserted due to its softness. old the end of the, and insert it all the way in slowly and securely. Refer to dimension in the dimension drawings for guidance on the insertion depth of. Tubing size ø ø ø ø ø Tubing insertion length (mm) 1 2 Installation and removal of 2. Removal of 1) ush in the release button sufficiently, pressing the collar evenly around its circumference. 2) ull out the while holding down the release button so that it does not pop out. If the release button is not pressed down sufficiently, there will be increased bite on the and it will become more difficult to pull it out. 3) When the removed is to be used again, first cut off the section of the which has been chewed. Using the chewed portion of the tube as it is can cause problems such as leakage or difficulty in removing the. Operating environment 1. Series K/T are special one-touch fittings for use on clean blowing and washing lines. lease consult with SC regarding other types of applications. Seal and materials: The durability of ED and polyolefin with respect to mineral oils is inferior, making them unsuitable for piping in general pneumatic. Use Series K, KG, T, TS, and TU for piping to general pneumatic. 1. Tightening of blow fittings (resin taper threads for piping) Since Series K taper threads are made of resin, minute leakage may gradually occur due to stress relaxation. erform periodic inspections, and if leakage is detected correct the problem by further tightening. If additional tightening becomes ineffective, replace the fitting with a new product. recaution on use of other brands aintenance 1. When using brands other than SC, confirm that the outside diameter tolerances satisfy the following specifications. 1) olyolefin Within ±0.1 mm 2) olyurethane Within ±0.1 mm Within 0.2 mm 3) Nylon Within ±0.1 mm ) Soft nylon Within ±0.1 mm Do not use if the outside diameter tolerance is not satisfied. It may not be possible to connect the, or leakage or disconnection may occur after connection. olyolefin is recommended for use with clean room fittings. Note that while other types of will satisfy performance standards for leakage and pull-out strength, etc., the degree of cleanliness will deteriorate. Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter 0
Clean one-touch fittings K Specific product precautions 2 Be sure to read before handling. Operating environment Warning 1. Do not use in environments or locations where there is a danger of damage to fittings and. For fitting and materials, refer to specifications and construction drawings, etc. 2. rovide shade in locations which receive direct sunlight. 3. Do not operate in locations where vibration or impact occurs. Since this can cause leakage and fitting damage, etc., please contact SC regarding use in this kind of environment.. rovide shielding in locations near heat sources. When there are heat sources in the surrounding area, the product's temperature may rise due to radiated heat and exceed its operating temperature range. Block off the heat with a cover, etc.. Do not use in locations where static electric charges will be a problem. lease consult with SC regarding use in this kind of environment.. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. lease consult with SC regarding use in this kind of environment. 1. Series K are special one-touch fittings for use on clean blowing and washing lines. lease consult with SC regarding other types of applications. Seal material: The durability of ED with respect to mineral oils is inferior, making it unsuitable for piping in general pneumatic. Use Series K and KG for piping to general pneumatic. aintenance 1. re-maintenance inspection When the product is to be removed, turn off the electric power, and be sure to cut off the supply pressure and confirm that fluid in the piping has been discharged. 2. ost maintenance inspection fter remounting and connection of piping, restore the fluid and electric power, and perform suitable function and leak tests. If leakage occurs or the does not operate properly, stop operation immediately and confirm whether it is mounted correctly. 3. Tightening of blow fittings (resin taper threads for piping) Since Series K taper threads are made of resin, minute leakage may gradually occur due to stress relaxation. erform periodic inspections, and if leakage is detected correct the problem by further tightening. If additional tightening becomes ineffective, replace the fitting with a new product.. Check for the following during regular maintenance, and replace components as necessary. a) Scratches, gouges, abrasion, corrosion b) eakage, refer to item 3 regarding taper thread leakage. c) Twisting, flattening or distortion of d) ardening, deterioration or softness of. Do not repair or patch the replaced or fittings for reuse. recaution on use of other brands 1. When using brands other than SC, confirm that the outside diameter tolerances satisfy the following specifications. 1) olyolefin Within ±0.1 mm 2) olyurethane Within +0.1 mm Within 0.2 mm 3) Nylon Within ±0.1 mm ) Soft nylon Within ±0.1 mm Do not use if the outside diameter tolerance is not satisfied. It may not be possible to connect the, or leakage or disconnection may occur after connection. olyolefin is recommended for use with clean room fittings. Note that while other types of will satisfy performance standards for leakage and pull-out strength, etc., the degree of cleanliness will deteriorate.
Clean one-touch fittings K Specific product precautions 3 Be sure to read before handling. ir cylinder 1. Do not use in locations where the connecting threads and connection will slide or rotate. The connecting threads and connection will come apart under these conditions. 2. Use at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tube. 3. lease consult with SC regarding fluids other than air, water and nitrogen gas.. In the case of liquid fluids, keep surge pressure at or below the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, this can cause damage to the fittings and. Selection 1. Store away from direct sunlight at 0 C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. andling 1. Before mounting confirm the model and size, etc. lso, confirm that there are no blemishes, nicks or cracks in the product. 2. When is connected, consider factors such as changes in the length due to pressure, and allow sufficient leeway. 3. ount so that fittings and are not subjected to twisting, pulling or moment loads. This can cause damage to fittings and flattening, bursting or disconnection of, etc.. ount so that is not damaged due to tangling and abrasion. This can cause flattening, bursting or disconnection of, etc. ounting Installation of threads Be sure to wrap sealing tape around the taper threads for both resin and metal threads. If used without sealing tape air leakage can occur. 1. Series K (with resin thread) 1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. 2) Tightening fter tightening by hand, tighten an additional 2 to 3 turns using a tightening tool. 2. Series K/KG (with metal thread) 1) For fter tightening by hand, tighten approximately 1/ turn further using a tightening tool. Excessive tightening can cause air leakage due to thread damage or deformation of the gasket, etc. Insufficient tightening can cause loose threads and air leakage, etc. Installation of threads 2) Taper thread (1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. (2) When installing, tighten with the proper torque shown in the table below. s a rule, this corresponds to two or three turns with a tool after tightening by hand. thread size R 1/ R R 3/ R Installation and removal of roper tightening torque N m to to 1 to 2 2 to 30 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. osition the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. 1. Installation of 1) Using tube cutters TK-1, 2 or 3, take a tube having no flaws on its periphery and cut it off at a right angle. Do not use pinchers, nippers or scissors, etc. The might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. 2) old the tube and push it in slowly, inserting it securely all the way into the fitting. 3) fter inserting the, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, problems such as leakage or disconnection of the can occur. ) Grease is not used due to the Series K oil-free specifications. For this reason, greater insertion force is required when is installed. In particular, polyurethane may fold when inserted due to its softness. old the end of the, and insert it all the way in slowly and securely. Refer to dimension in the dimension drawings for guidance on the insertion depth of. 2. Removal of 1) ush in the release button sufficiently, pressing the collar evenly around its circumference. 2) ull out the while holding down the release button so that it does not pop out. If the release button is not pressed down sufficiently, there will be increased bite on the and it will become more difficult to pull it out. 3) When the removed is to be used again, first cut off the section of the which has been chewed. Using the chewed portion of the tube as it is can cause problems such as leakage or difficulty in removing the. Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter