Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Similar documents
Recommended Applicable Tubing. Specifications. Particulate generation grade

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Clean One-touch Fittings

Clean One-touch Fittings. For Driving Air Piping. KPQ/KPG Series. Applicable Tubing. Tubing material. Specifications

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Miniature Tubing & Miniature Fittings

Series KJ. Miniature One-touch Fittings. Applicable Tube

Brass One-touch Fittings

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Stainless Steel 316 One-touch Fittings

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Clean Speed Controller with One-touch Fitting

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Tube Cutter with Measuring tape built-in

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Coiling Tube with Twist-Proof Fitting

Push-In Fitting Type with Stop Valve

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Multi Core Tube for General Pneumatic Piping

Push-In Fitting Type Pressure Gauge

Connection Thread M, R(PT), Rc(PT) How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod)

How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod) Straight union. T Different dia. straight. F Female connector TX Male elbow

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Tube for General Pneumatic Piping

Push-In Fitting Type Silencer

Pilot Check Valve: Metal Body Type

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

10 - TU0425 BU Color B Black W White R Red BU Blue Y Yellow G Green C Clear YR Orange. Tubing model. Inch size (Series TIUB) Model 3.

Speed Controller Anti-spatter Series

Pressure Gauge Series

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

Speed Controller Constant Flow

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

CHECK VALVES GPCVC Structural Diagram

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

Model SPCøD-T SPC4-M5 SPC4-M50 * 1 SPC4-M6 SPC4-02 SPC6-M5 SPC6-M6 SPC6-01 SPC6-02 SPC16-03

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Model PCøD-TSUS PC4-M6SUS PC4-01SUS PC4-02SUS PC6-M5SUS PC6-M6SUS PC6-01SUS PC6-02SUS PC16-03SUS

reduces flow setting time and setting errors!

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

4-63 T UBE FITTINGS TUBING P OLYURETHANE TUBING SERIES TU P RODUCTS FOR A LIST OF STOCKED PRODUCTS, PLEASE SEE THE CURRENT SMC PRICE LIST S TOCKED

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

PVC Quick Drain Valve

Smooth Vent Valve XVD. Series

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

ROTARY JOINTS NHRC Structural Diagram

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

Die Temperature Control Fitting Series

Smooth Vent Valve. XVD Series

Pad Swinging Attachment

Series IRV1000/2000/3000

Clean Regulator/Fluororesin Type

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Industrial Filter. FGD series

INSTALLATION & MAINTENANCE INSTRUCTION

Air Saving Valve. Pressure Valve Flow Valve

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Operating instruction

Series AMJ. Drain Separator for Vacuum

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

TECHNICAL DATA CAUTION

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Related Products: Auto Drain Valve. Model/Specifications. Model

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

3/8" Dr. Air Butterfly Impact Wrench

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

F l o w c o n T R o l v a l v E S

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

User Guide for. UTR Turbo Air Lappers Pneumatic Air Grinders & Lappers UTR-30, UTR-70, UR , ,

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Transcription:

Series K Clean one-touch fittings For blowing Recommended applicable olyolefin: Series T Tubing material Soft polyolefin: Series TS Tubing O.D. ø, ø, ø, ø, ø olyurethane Series TU, Nylon Series T, and Soft nylon Series TS can also be used. owever, the degree of cleanliness will decline. Note 2) Due to the softness of polyurethane, it may fold when being inserted. old the end of the and insert it all the way in. Refer to "Installation and Removal of Tubing". Specifications article generation grade Grade 1 (Refer to front matter pages to for details.) Fluid ir, Nitrogen gas, Water (ure water) aximum operating pressure (20 C) 1 a Note 2) Operating vacuum pressure 0 ka roof pressure (20 C) 3 a mbient and fluid temperature 20 C to 0 C Threads JIS B0203 (Taper thread for piping) Consult SC regarding other fluids. Note 2) The maximum operating pressure is the value at 20 C. Refer to the operating pressure curve for other temperatures. rincipal parts material Body Stud Chuck Guide, Stopper, Drive bushing Collet, Release button Seal, O-ring, Bumper olypropylene resin olypropylene resin Stainless steel 30 Stainless steel 30 olypropylene resin ED Series K is a line of special one-touch fittings for use in clean room blowing and washing lines. lease consult with SC regarding other types of applications. Seal material: The durability of ED with respect to mineral oils is inferior, which makes it unsuitable for piping in general pneumatic. Relationship between operating temperature and maximum operating pressure 1.2 aximum operating pressure a 1.0 0. 0. 0. 0.2 0 20 0 20 0 0 0 Operating temperature C 0

Dimensions ale connector: K ale elbow: K O.D.(mm) ale branch tee: KT ale run tee: KY 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ ale branch Y : KU 1/ 1/ 1/ 3/ 3/ 1/ 1/ 1/ 3/ 3/ odel K0-01. K0-02. 1 K0-01 1. K0-02 2. 20. K0-01 32.3 2. K0-02 30.3 2. K-02 3. 32 1 K-03 33 2 2 K-03 3 2 K-0 3. 2 odel K0-01 K0-02 K0-01 K0-02 K0-01 K0-02 K-02 K-03 K-03 K-0 odel KT0-01 KT0-02 KT0-01 KT0-02 KT0-01 KT0-02 KT-02 KT-03 KT-03 KT-0 odel KY0-01 KY0-02 KY0-01 KY0-02 KY0-01 KY0-02 KY-02 KY-03 KY-03 KY-0 odel KU0-01 KU0-02 KU0-01 KU0-02 KU0-01 KU0-02 KU-02 KU-03 KU-03 KU-0 1 1 1 1 1 1 1 1 1.. 1. 1.. 1. 1.. 1... 1. 2 2 2 Clean one-touch fittings K 3 2 1 1 2... 2.. 1.3... 2. 1 20.. 2.3 2. 31. 1 20.. 2.3 2. 31.. 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 2. 2. 2 2 30 31. 3. 3. 3. 1. 2. 2. 2 2 30 31. 3. 3. 3. 1. 1. 3... 2.. 1. 3.. 1 1 2 1 2 3. 3. 3 0 1 0.1.1 2.3 0..2 1.2 2.2.. 1 1 1 1 indicates the maximum diameter. 20 2 2 1 indicates the maximum diameter. 1 20.. 2.3 2. 31. 2 2.2 2. 2. 2. 2. 32.1 33.1 3.3 3.3 0 2 3. 0.. 2. 1.. 1 23 2 30. 1 1 1. 2 2 0 2 0 0 0 3 0 indicates the maximum diameter. 2 2 1 20 2 1 indicates the maximum diameter. 2 2 2 1 1 1 2-2 1 2 2 1 1 2-1 1 1 1 2- ir cylinder Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter 0

Clean one-touch fittings K Dimensions Straight union: K Elbow: K Union tee: KT Union Y : KU lug-in reducer: KR lug: K odel K0-00 K0-00 K0-00 K-00 K-00 odel K0-00 K0-00 K0-00 K-00 K-00 odel KT0-00 KT0-00 KT0-00 KT-00 KT-00.. 1... 1... 1. fitting size ød odel KR0-0. KR0-0 KR0-0. KR0- KR0- KR0- KR- 1. fitting size ød odel KU0-00 KU0-00 KU0-00 KU-00 KU-00 odel K-0 K-0 K-0 K- K-.. 1. 1 1 3. 2.1..2 3. 3... 0. 20.. 2.3 2. 31. 20.. 2.3 2. 31. 3. 1. 2. 0. 2 20.. 2. 30. 32. 1 2 1 2 1 2 1 1 indicates the maximum diameter. 3. 3. 1 3 0 0..3.. 1 2 3 1 20 indicates the maximum diameter. 2 1 1 2..3.. 1 2 1 2 indicates the maximum diameter. 20.1 3 1 20.2 20..2 2 1. 2 1 2 indicates the maximum diameter. 32 3 3 3.. 1..3 1.2 20. 2 1 1 2 0. 0. 1.1 1. 2... 1.... 1.1 1.1 1 2 2 32 indicates the maximum diameter. ød 2-1 ø 2 ø ø.2 ø 2- ø.2 ød 3- ø.2 3- fitting size ød fitting size ød 0

Clean one-touch fittings K Specific product precautions 1 Be sure to read before handling. ir cylinder Installation of threads Be sure to wrap sealing tape around the taper threads for resin thread. If used without sealing tape air leakage can occur. 1. Series K (with resin thread) 1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. 2) Tightening fter tightening by hand, tighten an additional 2 to 3 turns using a tightening tool. 2. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. osition the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. Installation and removal of 1. Installation of 1) Using tube cutters TK-1, 2 or 3, take a tube having no flaws on its periphery and cut it off at a right angle. Do not use pinchers, nippers or scissors, etc. The might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. 2) old the tube and push it in slowly, inserting it securely all the way into the fitting. 3) fter inserting the, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, problems such as leakage or disconnection of the can occur. ) Grease is not used due to the Series K oil-free specifications. For this reason, greater insertion force is required when is installed. In particular, polyurethane may fold when inserted due to its softness. old the end of the, and insert it all the way in slowly and securely. Refer to dimension in the dimension drawings for guidance on the insertion depth of. Tubing size ø ø ø ø ø Tubing insertion length (mm) 1 2 Installation and removal of 2. Removal of 1) ush in the release button sufficiently, pressing the collar evenly around its circumference. 2) ull out the while holding down the release button so that it does not pop out. If the release button is not pressed down sufficiently, there will be increased bite on the and it will become more difficult to pull it out. 3) When the removed is to be used again, first cut off the section of the which has been chewed. Using the chewed portion of the tube as it is can cause problems such as leakage or difficulty in removing the. Operating environment 1. Series K/T are special one-touch fittings for use on clean blowing and washing lines. lease consult with SC regarding other types of applications. Seal and materials: The durability of ED and polyolefin with respect to mineral oils is inferior, making them unsuitable for piping in general pneumatic. Use Series K, KG, T, TS, and TU for piping to general pneumatic. 1. Tightening of blow fittings (resin taper threads for piping) Since Series K taper threads are made of resin, minute leakage may gradually occur due to stress relaxation. erform periodic inspections, and if leakage is detected correct the problem by further tightening. If additional tightening becomes ineffective, replace the fitting with a new product. recaution on use of other brands aintenance 1. When using brands other than SC, confirm that the outside diameter tolerances satisfy the following specifications. 1) olyolefin Within ±0.1 mm 2) olyurethane Within ±0.1 mm Within 0.2 mm 3) Nylon Within ±0.1 mm ) Soft nylon Within ±0.1 mm Do not use if the outside diameter tolerance is not satisfied. It may not be possible to connect the, or leakage or disconnection may occur after connection. olyolefin is recommended for use with clean room fittings. Note that while other types of will satisfy performance standards for leakage and pull-out strength, etc., the degree of cleanliness will deteriorate. Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter 0

Clean one-touch fittings K Specific product precautions 2 Be sure to read before handling. Operating environment Warning 1. Do not use in environments or locations where there is a danger of damage to fittings and. For fitting and materials, refer to specifications and construction drawings, etc. 2. rovide shade in locations which receive direct sunlight. 3. Do not operate in locations where vibration or impact occurs. Since this can cause leakage and fitting damage, etc., please contact SC regarding use in this kind of environment.. rovide shielding in locations near heat sources. When there are heat sources in the surrounding area, the product's temperature may rise due to radiated heat and exceed its operating temperature range. Block off the heat with a cover, etc.. Do not use in locations where static electric charges will be a problem. lease consult with SC regarding use in this kind of environment.. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. lease consult with SC regarding use in this kind of environment. 1. Series K are special one-touch fittings for use on clean blowing and washing lines. lease consult with SC regarding other types of applications. Seal material: The durability of ED with respect to mineral oils is inferior, making it unsuitable for piping in general pneumatic. Use Series K and KG for piping to general pneumatic. aintenance 1. re-maintenance inspection When the product is to be removed, turn off the electric power, and be sure to cut off the supply pressure and confirm that fluid in the piping has been discharged. 2. ost maintenance inspection fter remounting and connection of piping, restore the fluid and electric power, and perform suitable function and leak tests. If leakage occurs or the does not operate properly, stop operation immediately and confirm whether it is mounted correctly. 3. Tightening of blow fittings (resin taper threads for piping) Since Series K taper threads are made of resin, minute leakage may gradually occur due to stress relaxation. erform periodic inspections, and if leakage is detected correct the problem by further tightening. If additional tightening becomes ineffective, replace the fitting with a new product.. Check for the following during regular maintenance, and replace components as necessary. a) Scratches, gouges, abrasion, corrosion b) eakage, refer to item 3 regarding taper thread leakage. c) Twisting, flattening or distortion of d) ardening, deterioration or softness of. Do not repair or patch the replaced or fittings for reuse. recaution on use of other brands 1. When using brands other than SC, confirm that the outside diameter tolerances satisfy the following specifications. 1) olyolefin Within ±0.1 mm 2) olyurethane Within +0.1 mm Within 0.2 mm 3) Nylon Within ±0.1 mm ) Soft nylon Within ±0.1 mm Do not use if the outside diameter tolerance is not satisfied. It may not be possible to connect the, or leakage or disconnection may occur after connection. olyolefin is recommended for use with clean room fittings. Note that while other types of will satisfy performance standards for leakage and pull-out strength, etc., the degree of cleanliness will deteriorate.

Clean one-touch fittings K Specific product precautions 3 Be sure to read before handling. ir cylinder 1. Do not use in locations where the connecting threads and connection will slide or rotate. The connecting threads and connection will come apart under these conditions. 2. Use at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tube. 3. lease consult with SC regarding fluids other than air, water and nitrogen gas.. In the case of liquid fluids, keep surge pressure at or below the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, this can cause damage to the fittings and. Selection 1. Store away from direct sunlight at 0 C or less. 2. Open the inner package of double packaging in a clean room or other clean environment. andling 1. Before mounting confirm the model and size, etc. lso, confirm that there are no blemishes, nicks or cracks in the product. 2. When is connected, consider factors such as changes in the length due to pressure, and allow sufficient leeway. 3. ount so that fittings and are not subjected to twisting, pulling or moment loads. This can cause damage to fittings and flattening, bursting or disconnection of, etc.. ount so that is not damaged due to tangling and abrasion. This can cause flattening, bursting or disconnection of, etc. ounting Installation of threads Be sure to wrap sealing tape around the taper threads for both resin and metal threads. If used without sealing tape air leakage can occur. 1. Series K (with resin thread) 1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. 2) Tightening fter tightening by hand, tighten an additional 2 to 3 turns using a tightening tool. 2. Series K/KG (with metal thread) 1) For fter tightening by hand, tighten approximately 1/ turn further using a tightening tool. Excessive tightening can cause air leakage due to thread damage or deformation of the gasket, etc. Insufficient tightening can cause loose threads and air leakage, etc. Installation of threads 2) Taper thread (1) Wrapping of pipe tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1. to 2 thread ridges exposed at the end of the threads. (2) When installing, tighten with the proper torque shown in the table below. s a rule, this corresponds to two or three turns with a tool after tightening by hand. thread size R 1/ R R 3/ R Installation and removal of roper tightening torque N m to to 1 to 2 2 to 30 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. osition the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. 1. Installation of 1) Using tube cutters TK-1, 2 or 3, take a tube having no flaws on its periphery and cut it off at a right angle. Do not use pinchers, nippers or scissors, etc. The might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage. 2) old the tube and push it in slowly, inserting it securely all the way into the fitting. 3) fter inserting the, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, problems such as leakage or disconnection of the can occur. ) Grease is not used due to the Series K oil-free specifications. For this reason, greater insertion force is required when is installed. In particular, polyurethane may fold when inserted due to its softness. old the end of the, and insert it all the way in slowly and securely. Refer to dimension in the dimension drawings for guidance on the insertion depth of. 2. Removal of 1) ush in the release button sufficiently, pressing the collar evenly around its circumference. 2) ull out the while holding down the release button so that it does not pop out. If the release button is not pressed down sufficiently, there will be increased bite on the and it will become more difficult to pull it out. 3) When the removed is to be used again, first cut off the section of the which has been chewed. Using the chewed portion of the tube as it is can cause problems such as leakage or difficulty in removing the. Rotary actuator ir gripper Directional control valve Flow control Filter, ressure control Fittings & Tubing ir preparation ressure switch Clean gas filter