VAREC 180 SERIES PRESSURE REGULATORS

Similar documents
CASH VALVE TYPE KP BACK PRESSURE VALVES

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

T208VR Series Tank Blanketing Vacuum Regulator

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

66 Series Direct-Operated Regulators and Vacuum Service Equipment

Type 1190 Low-Pressure Gas Blanketing Regulator

Types ACE95 and ACE95Sr Tank Blanketing Valves

Y692VB Series Vacuum Breaker

Model 1800 PFM Series Regulator. Technical Bulletin

Type ACE95jr Tank Blanketing Valve

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

1805 Series Relief Valves

627 Series Pressure Reducing Regulators

Mark 958 Series Sanitary Gas Back Pressure Regulators

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Types ACE95 and ACE95Sr Tank Blanketing Valves

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

Type 99 Pressure Reducing Regulators

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Types ACE95 and ACE95Sr Tank Blanketing Valves

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Type EZH Relief or Backpressure Regulator

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Noth American 7347 High Pressure Gas Regulators

Type Y692 Gas Blanketing Regulator System

299H Series Pressure Reducing Regulators

SR100 Series Service Regulators. Technical Bulletin

Type 299 Pressure Reducing Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Type 63EG Relief Valve or Backpressure Regulator

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Anderson Greenwood Type 4142 piped away pressure relief valves

FLAME ARRESTOR MODEL L76C-UF

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

S300 Series. Valve Link. Features. Fisher Controls

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction

Type Cronos Pressure Reducing Regulator

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

Mark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators

Type 92S Pilot-Operated Steam Regulator

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

R-1450 R6. Safety Relief Valve

PRO-50 Instrument Supply Regulator

Model 8800A. Pressure Relief and Vacuum Breaker Valve with Flame Arrester

2.0 INSTALLATION & SERVICE

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type R622 Pressure Reducing Regulator

Tank Blanketing Pressure Regulators RHPS Series

V DGX Series. Direct-Operated Regulators Manual D103834X012

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Anderson Greenwood Series 90/9000 Pilot Operated Pressure Relief Valves

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

Series 100 Slam Shut Valve. Technical Bulletin

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

64 Series Pressure Reducing Regulators

North American 7339 High Pressure Gas Regulators

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Full Range Pressure Compensating Variable Flow Control

Types S100K and S102K Pressure Regulators

1301 Series High-Pressure Regulators

EZR Series Pressure Reducing Regulator

829S1 Series Flexflo Pilot

1800CPB2 Service Regulators

Model 4000 Pressure Controller

627 Series Pressure Reducing Regulators

1800CPB2 Pilot-Loaded Service Regulators

B34 Series Regulator Commercial and Industrial Regulator

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

EZH and EZHSO Series Pressure Reducing Regulators

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

North American Orifice Metering System

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

North American 7337A/B/C-4 High Pressure Gas Regulators

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

ZUERCHER BR Series LOW PRESSURE IN-LINE & ANGLE-PATTERN TANK PRESSURE REDUCING REGULATORS

BACK PRESSURE / SUSTAINING

D05 Pressure Regulating Valves

BACK PRESSURE / SUSTAINING

HORIZONTAL BLADDER TANK

VERTICAL BLADDER TANK

AIR AND VACUUM VALVES

1301 Series High-Pressure Regulators

HP/UHP Spring-Loaded Regulator

Liquid Level Controllers

Mark 608. Gas Pressure Regulators. Pressure Regulators Mark 608 Gas Pressure Regulators SPECIFICATIONS (3/4-1-1/4 ) FEATURES 3/4-1-1/4

Transcription:

Double port regulators with a variety of model options for upstream and downstream pressure control FETURES Large diaphragm and a unique double port design achieve a sensitivity of less than 5%. Set pressure controlled by a weighted lever for settings below 1" (25 mm) WC; combination weighted lever and spring for settings up to 20" (50 mm) WC. Double port design adds a dampening effect, allowing the valve smoothly to seek set pressure. Rotary linkage design eliminates friction and drag. Diaphragm chamber and valve body completely isolated to eliminate leakage. Wide range of materials for service in most applications. Easily adjustable setting for fine tuning in the field. Can be set as close as 0.4" WC apart (blanket and recovery). GENERL PPLICTION The 180 Series regulators are designed for use on vapor recovery systems where sensitive control at low pressures is required. They are not recommended for gas tight shutoff applications. TECHNICL DT Materials: luminum, carbon steel Sizes: 1 to 8 (25 to 200 mm) Connections 1 size: Threaded 2 to 8 sizes: Drilled flange Pressure settings: -0.4" to 20 WC (-10 to 500 mm WC) Emerson.com/FinalControl 2017 Emerson. ll Rights Reserved. VCTDS-00303-EN 17/07

SPECIFICTIONS OPERTION The 180 and 186 Series regulators are designed for upstream control, regulating gas in lines going from tanks to vapor recovery compressors. Upstream pressure sensed through control line piping is applied to one side of the diaphragm. The pressure acts against the weighted lever arm, moving the diaphragm linkage. The movement positions the valve to regulate gas flow. s the upstream pressure of the valve increases, the linkage opens the valve, allowing a greater flow capacity. s the pressure is relieved, the valve throttles toward its closed position. The 181 and 187 Series regulators are designed for downstream control, including tank blanketing applications. Downstream pressure sensed through the control line piping is applied to one side of the diaphragm. The pressure acts against the weighted lever arm, moving the diaphragm linkage. The movement positions the valve to regulate gas flow. s the downstream pressure of the valve decreases, the linkage opens the valve, causing an increase in flow capacity. s the pressure increases, the valve throttles toward its closed position. Sizes 1", 2", 3", 4", 6", 8" Materials Body Trim luminum Carbon steel 304 Stainless steel Diaphragm housing 180/181 Galvanized steel 186/187 Cast aluminum Diaphragm Nylon reinforced NBR Fiberglass reinforced PTFE Fiberglass reinforced FKM Connections 1" Size NPT threaded 2" to 8" Size: luminum: drilled to NSI 150# FF Steel: drilled to NSI 150# RF Pressure sensing line 180/181 2" Male NPT connection 186/187 1" Female NPT connection Settings 180/181 0.4" (10 mm) WC vacuum to 1" (25 mm) WC 1" (25 mm) WC to 1.5" (38 mm) WC 186/187 2" (50 mm) WC to 10" (250 mm) WC 10" (250 mm) WC to 20" (500 mm) WC Downstream vacuum (Models 180 and 186) Must remain between atmospheric and 4.91 psig (0.34 barg) vacuum. Upstream pressure (Models 181 and 187) Must remain between atmospheric and 20 psig (1.38 barg). Pressure differential for full flow 180/181 0.4" (10 mm) WC 186/187 1.5" (38 mm) WC Repeatability Will maintain pressure within 0.1" (2.5 mm) WC of set point. 2

SPECIFICTIONS DIMENSIONS, inches and pounds (millimeters and kilograms) Size code 01 02 03 04 06 08 Nominal pipe size 1 (25) 2 (50) 3 (80) 4 (100) 6 (150) 8 (200) 5 (127) 7 11 /16 (195) 10 (254) 12 (305) 15 (381) 17½ (445) B 3⅛ (79) 4¼ (108) 5⅛ (130) 5⅞ (149) 7¾ (197) 8¾ (222) C 10½ (267) 11⅛ (283) 12 1 /16 (306) 12 11 /16 (322) 14 9 /16 (370) 15 9 /16 (395) D 10¾ (273) 10¾ (273) 10¾ (273) 10¾ (273) 13½ (343) 13½ (343) E 26 (660) 26 (660) 26 (660) 26 (660) 32 (813) 32 (813) * 85 (39) 120 (55) 150 (68) 180 (82) 210 (95) 260 (118) * Shipping weight Shipping weights are for aluminum construction. 5¾ (146) E C D B Drain 2 NPT Section - - Model 180 Back pressure type (upstream control) Section - - Model 181 Back reducing type (downstream control) DIMENSIONS, inches and pounds (millimeters and kilograms) Size code 01 02 03 04 06 08 Nominal pipe size 1 (25) 2 (50) 3 (80) 4 (100) 6 (150) 8 (200) 5 (127) 7 11 /16 (195) 10 (254) 12 (305) 15 (381) 17½ (444) B 3⅛ (79) 4¼ (108) 5⅛ (130) 5⅞ (149) 7¾ (197) 8¾ (222) C 7 (178) 7⅝ (194) 8 9 /16 (217) 9 3 /16 (233) 11 1 /16 (281) 12 1 /16 (306) * 85 (39) 120 (55) 150 (68) 180 (82) 210 (95) 260 (118) * Shipping weight Shipping weights are for aluminum construction. 4 11 /16 (119) Section - 20½ (521) Dia C B 8 3 /16 (208) B Drain 1 NPT Control line connection B Section B-B - Model 186 Section B-B - Model 187 Installation, mounting arrangement and dimensions are preliminary general information not be used for construction. Certified drawings are available. 3

FLOW CURVES 180, 181, 186 ND 187 REGULTORS 16 1 2 14 Pressure (DP) across valve Inches of water 12 10 8 6 4 2 0 0 1000 2000 3000 4000 5000 6000 7000 Cubic feet/hour at 60 F and 14.7 psia, air flow (SCFH) 180, 181, 186 ND 187 REGULTORS 16 14 Pressure (DP) across valve Inches of water 12 10 8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Thousand cubic feet/hour at 60 F and 14.7 psia, air flow (SCFH) 4

FLOW CURVES 180, 181, 186 ND 187 REGULTORS 100 700 900 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 200 300 400 500 600 800 1000 Pressure drop across valve in lbs. Per square inch (psi) 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Thousand cubic feet/hour at 60 F and 14.7 psia, air flow (SCFH) 5

REGULTOR SUMMRY Upstream control (back pressure regulator) Downstream control (pressure reducing regulator) 180 186 181 187 Upstream Downstream Upstream Downstream Upstream Downstream Upstream Downstream Set ranges Low: -0.4 < 1 WC High: 1 < 1.5 WC Set ranges Low: 2 < 10 WC High: 10 < 20 WC Set ranges Low: -0.4 < 1 WC High: 1 < 1.5 WC Set ranges Low: 2 < 10 WC High: 10 < 20 WC Full open Sense-set 0.4 WC Max. vacuum 4.91 psig Full open Sense-set 1.5 WC Max. vacuum 4.91 psig Max. pressure 20 psig Full open Set-sense 0.4 WC Max. pressure 20 psig Full open Set-sense 1.5 WC Body cross section Models 180/186 s upstream pressure increases, the valve opens (lifts). Body cross section Models 181/187 s downstream pressure increases, the valve closes (lifts). Functional description s the sense pressure increases, the linkage lifts the plug. s the sense pressure decreases, the linkage lowers the plug. Linkage schematic Diaphragm housing Setting spring Vent Sense press W1 Setting weights (fine adjustment) W2 Body plug 6

ORDERING INFORMTION SELECTION GUIDE Example: 18 1 L 2 1 B Model 18 Double port regulator Configuration (select one) 0 Back pressure (upstream control) - settings up to 1.5" (38 mm) WC 1 Pressure reducing (downstream control, including tank blanketing) - settings up 1.5" (38 mm) WC 6 Back pressure (upstream control) - settings up to 20" (500 mm) WC 7 Pressure reducing (downstream control, including tank blanketing) - settings up to 20" (500 mm) WC Setting range (select one) 180 and 181 186 and 187 L -0.4" < 1" (-10 < 25 mm) WC 2" < 10" (50 < 250 mm) WC H 1" to 1.5" (25-38 mm) WC 10" to 20" (250-500 mm) WC Size (select one) 1 1" 2 2" 3 3" 4 4" 6 6" 8 8" Valve body material (select one) 1 luminum 3 Cast steel Diaphragm material (select one) B NBR T PTFE V FKM Example: 2" pressure reducing double port regulator, aluminum body with NBR diaphragm. 7

8