Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Similar documents
Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Process Optical Dissolved Oxygen Probe

SDX Submersible Depth Transmitter User Manual

SDX Submersible Depth Transmitter User Manual

HI 2314 HI 2315 HI 23151

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

PAPR Flow Tester. instructions. part no WARNING

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

Model PDT Dewpoint Transmitter

Modbus Submersible Level Transducer

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

ASIC-Based Small Bore Submersible Level Transducer

EC214 EC215 - EC215R Bench Conductivity Meters

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

High-performance submersible pressure transmitter For level measurement Model LH-10

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

RDO Optical Dissolved Oxygen Sensor

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Deep Submersible Level Transducer Series 300DS

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

STARLOG. Capacitive Water Depth Probe

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Level TROLL OPERATOR S MANUAL. Level TROLL 300 Level TROLL 500 Level TROLL 700 BaroTROLL

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

NEULOG OXYGEN LOGGER SENSOR GUIDE

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Air Consumption Recommended Usage Siphon Feed

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Columbus Instruments

INSTALLATION & MAINTENANCE INSTRUCTIONS

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Research Grade Blood Pressure Transducer User's Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Multi-Probe Sampling System User Guide & Manual

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Oxygen Sensor with Electrode

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

AMS 2710 PCB pressure sensor module with V output

QUICK START GUIDE TO DRINKING WATER MONITORING

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Constant Pressure Inlet (CCN) Operator Manual

ETL Water Level Meter

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Submersible Pressure Transducer

Expert Hydrostatic Level Transmitters


T EK-SUB 4800C 19 mm Submersible Level Transmitter

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

AUTO PUMP STATUS CENTER

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Installation, Operation, and Maintenance Manual

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Underwater Housing for Canon EOS M

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

TRANSDUCER KIT 2 INSTALLATION INSTRUCTIONS

Simrad GD10P Extended On-site Maintenance

DeltaSpan General Purpose Water Small Bore or Wastewater Pressure Level Transmitter LD34 and LD35 Series Manual

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

86BSD Backside Digital Output

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

Dissolved Oxygen Sensor

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Precision Liquid Settlement Array Manual

Instruction Manual BA90 Precision Barometer

Gas Sampling Fitting with MK2.1 and L-Probe

PP-1, PP-1W, PP-2, & PP-3

RD(H)20/25 Pressure-Reducing Regulator User Manual

Multi-Parameter TROLL 9000 WQP-100 Operator s Manual

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

ASDX Series Silicon Pressure Sensors

BGA244 Binary Gas Analyzer

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Over 20,000 Strain Gage Target flowmeters installed since 1952.

High-performance submersible pressure transmitter For level measurement Model LH-10

Multi-Parameter Water Quality TROLL. Multi-Parameter TROLL 9500 WQP-100 OPERATOR S MANUAL

OxyProbe II Instruction Manual

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Precision pressure sensor Basic version Model CPT6020

OLYMPUS Tough TG-3 and TG-4 Waterproof Housing MANUAL

5 Channel Calibrator

DISSOLVED OXYGEN SENSOR BT34i

THE INSIDE STORY OF THE F-SERIES:

Invacare Twilight II Nasal Mask

Transcription:

Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved Gas (TDG) pressures in a variety of natural waters. The probe measures total dissolved gas pressure directly, and reports it relative to atmospheric pressure. This type of analysis is commonly called the Membrane Diffusion Method, and most closely models the behavior of fish gills. Designed for long-term installation, wired to a PLC or logger. The T900 contains a precision pressure transducer, conditioning electronics, a membrane cartridge, and a fixed length of vented cable (4, 10, or 20 meters) for connection to an external RS232 or analog (0 to 5 volt) input on PLCs, SCADA systems, or other controllers. The membrane cartridge consists of a sensing membrane approximately 1.5 meters of very small bore silicone tubing. One end of the tube is sealed, the other end is connected to the pressure transducer which converts the internal tube pressure to an electrical signal. The tube is permeable to all gases including water vapor. The T900 utilizes digital signal processing techniques to provide a calibrated and temperature-compensated 0-5 volt analog output. This output is directly proportional to the applied dissolved gas pressure. In addition, calibrated data is available via RS232 serial output. Precision electronics allow the probe to be powered from an unregulated 8.0 to 16.0 volt DC source without any effect on the probe s accuracy. The probe also features very low power consumption and is especially suitable for Pressure cap (optional) Membrane cartridge O-ring Serial number Cable Probe body (Pressure sensor & electronics) Guard Exploded view of probe components

Total Dissolved Gas T900 Page 2 battery powered instruments and data loggers. Probe maintenance requires regular cleaning of the membrane cartridge to remove biofouling. Biofouling affects only the response time of the probe and not the calibration. Changing the membrane cartridge has no effect on the calibration. Changing the membrane cartridge requires no tools or solutions, and may easily be done in the field. Connections For installation into a PLC, logger, or SCADA system providing 8-16 VDC or RS232 output: 2. Wire according to diagram below. Probe Desiccant DO NOT ATTEMPT TO TAKE THE PROBE APART. It contains special seals and delicate components. Disassembling voids all warranties. 3. Remove the end caps from desiccant cartridge. Use nylon ties and tubing to install desiccant cartridge. Assure that it is positioned above potential flood level. The open end of the cartridge should face down. Replace cartridge when desiccant turns pink in color. Care & Maintenance Repairs or servicing not covered here must be carried out by the manufacturer. Contact In-Situ as described on page 5. The Probe Store the probe out of direct sunlight and protect it from excessive moisture. Do not store the probe in a sealed plastic bag. If the probe has been used in brackish, dirty, or otherwise contaminated water, be sure to rinse the probe in clean water after use, and clean the membrane. Do not let contaminants dry on the probe surface. The Membrane Cartridge The membrane cartridge, if handled carefully and cleaned regularly, can last indefinitely. Membranes with five years field usage have been tested and found to have characteristics identical to those of new membranes. The most significant factors that will deteriorate the tubing are direct sunlight, dirt buildup, and biofouling.

Total Dissolved Gas T900 Page 3 Cleaning the Membrane Cartridge We recommend you leave the membrane cartridge attached to the probe for cleaning. If you do remove it, take care to prevent fluid from entering the open end of the cartridge. If the probe is being used in brackish, dirty, or otherwise contaminated water, be sure to clean the membrane cartridge regularly. This can be done without removing the cartridge from the probe. 2. Carefully remove the slotted guard by turning counterclockwise. Leave the membrane cartridge attached to the probe. 3. Prepare a warm soapy solution in a 500 ml beaker or similar container. Use a mild, non-oily soap. 4. Submerge the membrane cartridge in the warm soapy solution. 5. Using a SOFT toothbrush (a baby s toothbrush is ideal), gently stroke the membrane filament as shown. This will remove most attached dirt and debris. Do not pinch the membrane against the support. Use care, as the membrane material is sensitive to nicks and abrasions. Biofouling may be removed by rinsing in a dilute solution of common household bleach (4 parts water to 1 part bleach). Do not soak in any chemical solution for more than one minute. Never use strong acid or alkaline solutions. 6. Rinse thoroughly in clean water. Removing the Membrane Cartridge Grasp the membrane cartridge at the dimpled end To avoid permanent damage to the sensor, do not put anything into the pressure sensor orifice. If your probe includes a pressure cap, always attach it to the probe when the membrane cartridge is removed for any length of time. To replace the membrane cartridge, or check for moisture in the tubing, first remove the cartridge from the probe. 2. Carefully remove the slotted guard by turning counterclockwise. 3. Using your thumb and forefinger, grip the membrane cartridge at the dimples, located at the probe end. Gently unscrew the assembly, taking care not to touch the membrane tubing. Place the cartridge in a safe clean area. While the cartridge is off Inspect the face of the pressure orifice on the probe. If any beads of moisture appear on the surface, gently remove them with a tissue. Do not put anything into the small hole. Doing so will void the warranty. Inspect the cartridge where it fits onto the probe. It should be clean and free of moisture. Carefully remove any debris or moisture with a tissue. Be sure the miniature bore is not blocked. If the bore is clogged or plugged, the membrane cartridge will need to be replaced. Dimples Membrane cartridge Pressure orifice O-ring Miniature bore Probe body Guard

Total Dissolved Gas T900 Page 4 Removing Water Condensed in the Membrane If the probe is left in water for long periods, water vapor will eventually effuse through the membrane wall where it can condense and create pockets of water. This will affect the response and the accuracy of your readings. To dry the membrane: 1. Remove the membrane cartridge from the probe as described above and place it on a clean, dry, warm surface between 35 and 55 C (95 to 131 F) out of direct sunlight for a day or two. Alternatively, the cartridge may be placed in a warm oven for a few hours. Do not exceed 60 C (140 F). 2. Inspect the tubing through a magnifying glass to ensure that all moisture has evaporated. 3. When dry, reattach the cartridge to the probe take care not to touch the membrane tubing and replace the guard. Replacing the Membrane Cartridge 1. Remove the old membrane cartridge from the probe as described above. 2. Mount the new membrane cartridge. Be careful not to touch the membrane tubing. 3. Tighten the cartridge until it seats. Specifications The Sensor measures Differential Total Dissolved Gas Pressure ( P or delta P), which is the difference between the total dissolved gas and the ambient local barometric pressure. Range: ± 400 mm Hg Resolution: 0.5 mm Hg Accuracy: ±1.5 mm Hg over operating temperature range Signal Output: Digital/Analog Digital Output: RS232 ASCII strings (9600, 8, N, 1) -xxx.x mm Hg (for negative P) xxx.x mm Hg (for positive P) Analog Output: 0.0-5.0 V 400 mm Hg = 0.0 V 0.0 mm Hg = 2.5 V + 400 mm Hg = 5.0 V External Power: 8.0 to 16.0 VDC Power Consumption: 7 ma Materials: Delrin, silicone, stainless steel Media Compatibility: Fresh, salt or brackish waters Maximum Depth Measurement: 53 meters (173 ft) limit of accurate measurement Pressure sensor: 60 meters (196 ft) damage to the sensing element may occur beyond this depth, voiding warranty Operational Temperature: 0 C to +45 C (32 F to 113 F) Storage Temperature With membrane: 0 C to +60 C (32 F to 140 F) Without membrane: -40 C to +60 C (-40 F to +140 F) Cable: 4 meters (13 ft), 10 meters (33 ft), or 20 meters (66 ft) vented polyurethane RuggedCable

Total Dissolved Gas T900 Page 5 Accessories and replacement parts Part Catalog No. Membrane Cartridge...70-020 Cable reel, small steel...2214-0004 Refurbishment of returned membrane cartridge (call Tech Support for an RMA number)... 70-020RW How to Contact Us Technical Support: 800 446 7488 Toll-free 24 hours a day in the U.S. and Canada Address: In-Situ Inc. 221 East Lincoln Ave. Fort Collins, CO 80524 USA Phone: 970 498 1500 Fax: 970 498 1598 Internet: www.in-situ.com e-mail: support@in-situ.com WARRANTY In-Situ Inc. warrants the T900 for one year and warrants membrane cartridges for 30 days, from date of purchase by the end user against defects in materials and workmanship under normal operating conditions. To exercise this warranty contact Technical Support at the phone or e-mail address listed above for a return material authorization (RMA) and instructions. Complete warranty provisions are posted on our website at www.in-situ.com. 1 800 446 7488 (toll-free, US and Canada) or 970 498 1500 www.in-situ.com Information is subject to change without notice. In-Situ and the In-Situ logo, Baro Merge, BaroTROLL, HERMIT, Pocket-Situ, RDO, RuggedCable, RuggedReader, RDO, TROLL, Win-Situ are trademarks or registered trademarks of In-Situ Inc. Copyright 2006-2012 by In-Situ Inc. All rights reserved. 20-006 rev. 02 04/12