Patient Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Similar documents
Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Instructions For Use. Elastomeric Infusion Device

HEALTHCARE PROFESSIONAL GUIDE. Elastomeric Products

Making Life Easier Easypump II

PAIN RELIEF SYSTEM PATIENT GUIDELINES

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

Tourniquet Systems Pressure Infusion

Blood Pressure Monitoring: Arterial Line

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

Compatible Baxter IV Sets

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Balloon Gastrostomy (BG) Tube

Mirage Vista Nasal Mask

PUMP WITH FIXED FLOW RATE. Instructions for Use

Parts identification:

Basic Flows in a Microfluidic Device

Patients Guide for Self Administering Intravenous Antibiotics General points

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Alfred ECMO Circuit Priming and Storage Guide

Instructions for Use. OptiLife Nasal Lab Mask

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS

Information for patients and nurses. Rocket Ambulatory Chest Drain

Flexi-pro Aerosol Delivery System (FADS) Manual

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

Caregiver s Reference Guide

C O L O G Y. New. g u O N. l o t a C a. The high security connection

Micro Dial-Flowmeter. Instructions for Use

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

Port - Body in a Box User s Manual

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

Infusion. 1 evercare inline

leaders in enteral delivery

IVIG Educational Presentation

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

MyControl Bathing System Signature Series

Training Device Instructions

Home Oxygen Therapy in NHS Scotland. Level 1 Education for Patients & Carers

Troubleshooting Guide Aquarius

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Patient Home Care Information

Oxygen Dialflow Meter. Instructions for Use

User manual STARLOCK. Careways International - Innovation Quality Performance

SuperClear 15mL and 50mL Centrifuge Tubes

Patient Sleep Test Hookup

PRODUCT CATALOGUE OF

2D Labtainer BioProcess Container (BPC) systems

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

Peninsula Dental Social Enterprise (PDSE)

! CAUTION! ! WARNING! General Information

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

INSTALLATION INSTRUCTIONS

The Butterfly. Steep Trendelenburg Gel Bean Bag Positioner USE & CARE GUIDELINES DAVID SCOTT COMPANY

Date Effective: Date Reviewed: Nebraska Biocontainment Unit. Doffing Biological Protective Suit and PAPR

Nita Newborn Model 1800 User Manual

Instructions For Use. English 1 of 16

Instructions For Use. English 1 of 16

TOURNIQUET SYSTEMS & PRESSURE INFUSION

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

INVACARE. Bed Rail Selection Chart

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

TDUX Inflatable Duct Sealing System 1.0 General Product Information

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19

Airway Larry Airway Management Trainer Head LF03667U Instruction Manual

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

PLUMBING, FIRE SAFETY, AND RADIANT HEATING AND COOLING SYSTEMS INSTRUCTIONAL GUIDE. Making ProPEX Connections

Respiratory Equipment Update. Continuous Positive Airway Pressure (CPAP), Bi-level Positive Airway Pressure (BiPAP) and Related Accessories

Table of Contents Want full page pictures with most important parts labeled in the beginning.

LEAK TROUBLESHOOTING

Rev. B. Operating Instructions

TOURNIQUET SYSTEMS & PRESSURE INFUSION

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Paradise Pump Series Operator s Manual

Dual Electronic Basketball System Owners Manual

Safety Huber Needles

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Assisting with Insertion. Care of Intraspinal Catheters

Installation Instructions

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Chester Chest Model 2400 User s Manual

Chester Chest Model 2400 User s Manual

Stroller. Sprint S T R O L L E R S P R I N T

Oxygen Dialflow Meter. Instructions for Use

Complex Care Hub Manual: Oxygen Therapy

Extension Sets and Adaptors for Feeding Tubes by Susan Agrawal

Exploring the Properties of Gases

INFLATION GUIDE. Follow this step by step guide to inflate your board quickly and easily, to ensure maximum paddling performance and enjoyment.

Transcription:

Patient Guide Baxter Elastomeric Devices Promoting patient-centric care

How is medication delivered by the Infusor/ Intermate? The device is filled with medication prescribed by your physician. The product immediately starts delivering medication once it is connected to your catheter/port and will continue until it is empty or disconnected. As the elastomeric balloon consistently deflates it will gently push medication through your IV tubing and into your catheter/port. How should I carry it? For Infusors and Intermates; the Luer Lock Connector (refer to Diagram 1) should always be taped to your skin at approximately the same level as the top of the device (ie. Fill Port Cap refer to Diagram 1) in order to maintain an accurate flow rate. For Coil Tube Infusors, the Luer Lock Connector (refer to Diagram 1) should always be taped to your skin. Keep the top of the Infusor 15 cm 20 cm below the Luer Lock Connector (refer to Diagram 1) to maintain an accurate flow rate. Carry the device using the carrying case/pouch provided by our health care provider. Diagram 1 1 Winged Luer Cap protects the opening and stops the flow of medication. 2 Luer Lock Connector at the end of the tubing attaches the Infusor/Intermate to the catheter/port. 3 Coiled Tube Infusors Infusors 1 Flow Restrictor controls the infusion rate of the medication. 4 Tubing is kink-resistant and carries the medication from the device into your body. 5 Balloon Reservoir holds the medication. 6 Progression Lines may be horizontal or vertical on the plastic housing. These show the progress of the infusion. 7 Fill Port Cap protects the Infusor/Intermate device. 8 Plastic Housing. 9 Slide Clamp. 2 2 5 7 Intermates

Monitoring Infusion Progress Since the Infusor/Intermate delivers medication at a slow rate the elastomeric balloon reservoir will appear to be shrinking over several hours or days. Ensure that the IV tubing is not clamped or kinked. Utilize progression lines on the Infusor/Intermate housing to monitor infusion progress over time. Infusion is complete when the balloon is completely deflated and all eight indicator bumps (four on either side) on the inside of the device are clearly visible (refer to Diagram 2). Diagram 2 1 Indicator Bumps 2 Progression Lines 2 3

Diagram 3 Infusion Progression LV5 (2C1009KP) - Nominal Delivery Time is 48 hours Delivering accurate infusion. Continuously. 12 HRS INFUSED 24 HRS INFUSED 36 HRS INFUSED 4

5

Diagram 4 Infusion Progression LV1.5 (2C1087KP) - Nominal Delivery Time is 7 days Delivering accurate infusion. Continuously. 2 DAYS INFUSED 4 DAYS INFUSED 6 DAYS INFUSED 6

7

Contact your Healthcare Provider if: Patient name or medication is incorrect on the medication label. The expiration date on the label has passed. The medication does not appear to be flowing as expected (i.e. size of elastomeric balloon is not changing as expected). The Infusor/Intermate is leaking. Medication comes in contact with your skin: Immediately wash the area with water and soap. Place the device in the plastic bag provided (or any other plastic bag) and return to your healthcare provider. The elastomeric balloon has burst. Luer Lock Connector becomes un-taped from your skin (Infusor only). Consider these conditions that can affect flow rate Temperature: If using an Infusor, ensure Luer Lock Connector is taped to your skin. Ensure device remains at room temperature. Do not expose device to extreme heat/cold. Device Height: For Infusors and Intermates; ensure the top of the device is carried as close as possible to the same level as your catheter/port (where the Luer Lock Connector is taped to your skin). For Coil Tube Infusors, ensure the top of the Coil Tube Infusor is 15 cm 20 cm below where the device connects to your catheter/port (where the Luer Lock Connector is taped to your skin). 8

FAQ: Bathing The Infusor/Intermate device should not be submerged or exposed to a direct stream of water. Place the Infusor/Intermate in a plastic bag OR on a flat surface outside the shower/bath. Sleeping Place the Infusor/Intermate at approximately the same level to where the device connects to your catheter/port. The device can be placed on its side under your pillow. Exercise It is acceptable to exercise with the Infusor/Intermate as long as the product remains close to room temperature and is not exposed to water. Follow your healthcare provider guidelines. Pets The device is safe to use around pets, but ensure that it is protected from chewing and playing. Environment The Infusor/Intermate can be utilized during everyday activities (e.g. cooking) as long as the device is in a location where it can remain at room temperature and is not exposed to extreme heat/cold. Keep device out of direct sunlight. Travel It is safe to travel on planes that have pressurized cabins. If you have any questions about what you ve read here, please contact us at 1-888-719-9955. 9

Who will answer my questions? Health Care Provider: Telephone: Special instructions: 10

What I experienced at home with my Infusor/ Intermate: Infusion start date: Infusion expected end date: Infusion actual end date: Time: Time: Time: Date: Important notes: Date: Important notes: Date: Important notes: Please remember to share your experience at home with your Healthcare Provider. 11

Making a Meaningful Difference in Patients Lives. Baxter Corporation, 7125 Mississauga Rd., Mississauga, Ontario L5N 0C2, Canada. Baxter is a trademark of Baxter International Inc. Baxter is registered in the U.S. Patent and Trademark Office. Copyright 2014, Baxter Corporation. All rights reserved. MDELA.1006E.V2. 07/14