Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Similar documents
Usage Policies Notebook for Thermco Atmospheric Diffusion Furnace system

Usage Policies Notebook for Trion RIE / ICP Dry Etch

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Usage Policies Notebook for BMR HIDEP Low Temperature Plasma Enhanced CVD (LTPECVD)

Usage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100

Usage Policies Notebook for Parylene Coating System

Usage Policies Notebook for STS DRIE System

Usage Policies Notebook for HITACHI S Field Emission Scanning Electron Microscope System

Usage Policies Notebook for Quintel 2001 Mask Aligner

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

Usage Policies Notebook for Karl Suss MA6 Mid / Deep UV Mask Aligner

Birck Nanotechnology Center

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

University of Minnesota Nano Center Standard Operating Procedure

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Birck Nanotechnology Center

Standard Operating Manual

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

Basic ICP Operating Procedures

OXFORD PLASMALAB 80PLUS (CLOEY)

Nanofabrication Facility: PECVD SOP Rev. 00, April 24

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

Arizona State University Center for Solid State Electronics Research Issue: E Title: Heat Pulse 610 Operating Procedure Page 1 of 7

Thermcraft Tube Furnace General Use

Standard Operating Manual

University of MN, Minnesota Nano Center Standard Operating Procedure

Discovery HP-TGA 75/750. Site Preparation Guide

The MRL Furnaces USED FOR THIS MANUAL COVERS

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

RAPID THERMAL PROCESSOR (Annealsys AS-ONE 150) Lab Manual

Standard Operating Manual

Equipment Operating Procedure Glove Box

School of Chemistry SOP For Operation Of Glove Boxes

NORDSON MARCH PX-1000 PLASMA ASHER STANDARD OPERATING PROCEDURE Version: 1.0 July 2016

Standard Operating Manual

Unaxis PECVD. SiH4 (5% in He)

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Plasma Asher: March PX-500 User guide (May-30, 2017)

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

Approved by Principal Investigator Date: Approved by Super User: Date:

March CS-1701F Reactive Ion Etcher

1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

University of Minnesota, MN Nano Center Standard Operating Procedure

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

Operating Procedures for Metal Evaporator I

Plasma II (AXIC) Standard Operating Procedure. Revision: 1.0 Last Updated: Feb.6/2013, Revised by Grace Li

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Standard Operating Manual

University of Minnesota Nano Fabrication Center Standard Operating Procedure

Operating Procedures for the. SAMCO ICP RIE System

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

Nordiko Metal Sputtering System Standard Operating Procedure

CLEANLINESS STANDARD NCPRE tool contamination classification

USER S INFORMATION MANUAL

PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100

Rejuvenation Instructions

Savannah S100 ALD at SCIF, UC Merced Standard operating Procedure

Inert Air (N2) Systems Manual

Notes-PECVD: Chamber 1

Standard Operating Manual

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

University of MN, Minnesota Nano Center Standard Operating Procedure

Standard Operating Manual

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Oerlikon Sputtering Evaporator SOP

Arizona State University NanoFab XACTIX ETCHER. Rev A

Xactix XeF2 OPERATION MANUAL

Unifilm Technology PVD-300 Sputter Deposition Operation Instructions

Eco Snow CO2 Clean System Operation

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Arizona State University NanoFab PLASMATHERM 790 RIE. Version A

UCSC Laboratory Standard Operating Procedure (SOP) Compressed Gas Cylinder Change for MOCVD and CVD Systems

Cambridge NanoTech: Savannah S100. Table of Contents

Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM

Standard Operating Manual

Ammonia Treatment Instructions Page 1 of 5

Standard Operating Procedure

Flammability Chart. Gas Formula Ignition

Standard Operating Procedure. For. PVD E-Beam

Portable Oil Lube Air Compressors

Safety Manual Section 6 Confined Space

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Hazards associated with the gas system and how to mitigate them

SPUTTER STATION STANDARD OPERATING PROCEDURE

Describe Flammable Gas Measurement

LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY)

OPERATION MANUAL NTF-15

Approved by Principal Investigator Date: Approved by Super User: Date:

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

OPERATION MANUAL NTF-60 Plus

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

SAFE WORK PROCEDURE:

Transcription:

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System) Revision date October 2014

2 Emergency Plan for Nano Furnace Standard Operating Procedures for Emergencies Contact information Person Lab Manager Director Staff Super User Phone number Jake Hes, 949-824-8239 (day), 562-522-8328 (alternate) G.P. Li: 949-824-4194 (day), 949-824-2047 (alternate) Mo Kebaili: 949-824-8239 (day), 949-494-5892 (alternate) Phi Pham (720) 939-4500 Hazardous chemicals, gases, and conditions Hazard name Description of hazard High voltage CH 4 (Methane) H 2 (Hydrogen) N 2 (nitrogen) gas Ar (Argon) Electrical shock, ignition source Flammable, Non-corrosive Flammable, Non-corrosive Asphyxiant Non-flammable, Non-flammable, non-toxic

3 Alarms or indications of danger Alarm type Gas Detector (Enmet) H2 and CH4 O2 flow Alarm Pungent or foul smell Condition and response Problem with process state. Halt process and correct problem or notify the staff or the lab manager before continuing. Problem with process state. Halt process and correct problem or notify the staff or the lab manager before continuing. Gas leak. Shutdown the tool at once and evacuate the area. Contact the staff and the lab manager. Emergency shutdown plan #1 In the event of an emergency, when there is very little time, press the large red emergency shut-off button at the entrance of the room l, this will shutdown the gas system, and will stop the gas flow. Leave the facility at once, and then contact the lab manager or the staff. Emergency shutdown plan #2 In the event of an emergency, when there are a few minutes available, turn off the gas switches on the gas panel, the control power and the main power. This will stop gas flow into the system. If there is no fire, and no smell of gases, enter the room and close off all gas cylinders by turning them fully clockwise. Check the oxygen tank in room w2349, feel the door for possible fire, and if safe, close the oxygen tank by turning fully clockwise. Leave the facility at once, then, contact the staff and the lab manager.

4 IMPORTANT INFORMATION Hydrogen and methane combustible gases are used at atmospheric pressure and low pressure in the 5 EasyTube3000 Furnace to grow carbon nanotubes, graphene, and annealing. To avoid any potential fire or explosion, it is important to understand the lower and upper explosive limits of these combustible gases. A combustible gas will ignite only if the three following conditions are met: There is enough combustible gas to start a fire There is enough oxygen to oxidize the combustible gas There is a source of energy to ignite the combustible gas If all of the above three conditions are not present at the same time, then the combustible gas will not ignite and burn.!to have enough combustible gas to start a fire means that the concentration of the combustible gas present has to be between its lower explosive limit (LEL), or lower flammable limit (LFL) and upper explosive limit (UEL), or upper flammable limit (UFL). For hydrogen: 100% LEL is equal to 4% hydrogen by volume in air The UEL is equal to 75% hydrogen by volume in air For methane: 100% LEL is equal to 5% hydrogen by volume in air The UEL is equal to 16% hydrogen by volume in air Hydrogen and methane will auto ignite in the presence of oxygen at a temperature around 500 C!When the 5 EasyTube3000 is used to grow carbon nanotubes, and graphene, we already meet two of the three conditions to have a fire or an explosion:!inside the quartz tube: We have enough combustible gas (hydrogen and methane) We have the energy source (900 C furnace temperature) The missing condition is the presence of oxygen

5 Outside the quartz tube: We have enough oxygen We have the energy source (900 C furnace temperature) The missing condition is the presence of combustible gas! To prevent a fire or an explosion, we need to keep the oxygen from getting inside the quartz tube, and we need to keep the combustible gases from getting outside the quart tube.

6 Usage Policies for Nano Furnace Standard policies for usage The 5 nano furnace can accept up to 5 substrate to grow carbon nanotubes. Mass flow controllers digitally control H2, CH4, N2, and Ar gas flows. The programmable temperature range is up to 1000 C. Contact information The INRF staff or the lab manager can be reached at (949) 824-8239 or (949) 824-9831. Authorized users Only INRF registered users who have completed the training and passed the certification can use this equipment. Users can only use the portion of the system for which they have been trained. Training Users must have received direct training from the staff in order to use this equipment. Users are expected to understand the nature of the system, as well as the proper control and use of the gases. Training varies slightly, depending on the process to be performed. Contact the staff for details and to arrange for a training session. Usage log sheets Users are required to log all activities in the log sheets provided. All users must log in when they used the furnace (date and time), which gases they used, and when they completed their process in the user log sheets. If users notice anything unusual, they should record it in the user log sheets, and add details in the main comments area on the log sheet. Any maintenance to the tool will be logged in the maintenance log sheet (maintenance staff only). Safety equipment As safety equipment for use on this equipment, cleanroom gloves and tweezers should be used when handling pieces in the tube. Care should be taken to avoid burns when working near the furnace tube. The users need to use the gas leak detector to make sure that no gas is leaking from the furnace tube end cap. Standard equipment and materials The laboratory provides the following gases: N 2, H 2, CH 4, and Ar. Other gases must be cleared with the lab manager.

7 User maintenance * To keep the furnace contaminant free, keep the end cap on the tube when it is not in use to keep a positive pressure within the furnace tube under N 2 flow. Waste disposal Dispose of alcohol soaked wipes in a waste container marked for flammable solid waste. Scheduling Reservation can be done online, and the system can be used on a first come, first served usage if no reservation was made. Other issues Users should remain physically present in the cleanroom facility during the entire use of the nano furnace. At no time should a user adjust a pressure regulator on a gas line. Gas control should be on or off only, using only the appropriate valves. For most gases, this is usually the valve at the cylinder head. Non-standard use Users may not modify any hardware on this equipment. For use of non-standard processes, gases or materials, contact the staff or the lab manager.

8 Usage Notes for EasyTube3000 Guide for using the EasyTube3000 All gas cylinders should be turned on or off at the cylinder valves. At no time should a user adjust a pressure regulator. Clockwise for all valves, means CLOSED. The standard off configuration for the system is to close the cylinders valves, but leave all other valves alone. System Setup The 6 nano furnace can accept up to 4 substrate to grow carbon nanotubes, graphene, and perform vacuum anneals. Mass flow controllers digitally control H2, CH4, N2, and Ar gas flows. The programmable temperature range is up to 1000 C. When the 6 nano furnace is in the idle mode, 1 L/min of nitrogen gas flows in the quartz tube. This nitrogen flow maintains a positive pressure in the quartz tube to keep it clean from particulates contamination. There are six mass flow controllers dedicated for H2, CH4, N2, and Ar, C2H2 used by the 6 nano furnace. Each mass flow controller can be digitally set to maintain a preset gas flow. Safety Check The 6 nano furnace is monitored by a set of combustible gas leak detectors. There is a combustible detector installed in the back of the furnace where the mass flow controllers are located. There is a second combustible gas detector installed above the wafer loading area of the furnace front. The users should verify that the exhaust scavenger has a negative flow. The users should check for any potential leak of combustible gases with the handheld leak detector, at the front-loading area of the 6 nano furnace. In case of a potential combustible gas leak, the users should abort their process, they should stop flowing combustible gases inside the 6 nano furnace, by setting the hydrogen and methane mass flow controllers to zero. The users should immediately contact the INRF staff or the lab manager.

9 Usage Notes for Nano Furnace Guide for using the Nano Furnace Gas Cylinders All gas cylinders should be turned on or off at the cylinder valves. At no time should a user adjust a pressure regulator. Clockwise for all valves, means CLOSED. The standard off configuration for the system is to close the cylinders valves, but leave all other valves alone. System Setup The 6 nano furnace can accept up to 4 substrate to grow carbon nanotubes, graphene, and perform vacuum anneals. Mass flow controllers digitally control H2, CH4, N2, and Ar gas flows. The programmable temperature range is up to 1000 C. When the 6 nano furnace is in the idle mode, 1 L/min of nitrogen gas flows in the quartz tube. This nitrogen flow maintains a positive pressure in the quartz tube to keep it clean from particulates contamination. There are six mass flow controllers dedicated for H2, CH4, N2, and Ar, C2H2 used by the 6 nano furnace. Each mass flow controller can be digitally set to maintain a preset gas flow. Safety Check The 6 nano furnace is monitored by a set of combustible gas leak detectors. There is a combustible detector installed in the back of the furnace where the mass flow controllers are located. There is a second combustible gas detector installed above the wafer loading area of the furnace front. The users should verify that the exhaust scavenger has a negative flow. The users should check for any potential leak of combustible gases with the handheld leak detector, at the front-loading area of the 6 nano furnace. In case of a potential combustible gas leak, the users should abort their process, they should stop flowing combustible gases inside the 6 nano furnace, by setting the hydrogen and methane mass flow controllers to zero. The users should immediately contact the INRF staff or the lab manager.

10 The Easy Tube 3000 Nano Furnace can be used to do carbon nanotube growth, graphene growth, and annealing at both ambient and low pressures. It is important to know the dangers of each recipe you are running including gas flow and pressure gauges. Generally, when you walk in, the furnace will be in standby mode which means the loading chamber and the growth chamber are at ambient pressure, and under N2 gas purge. Verify that the sample loader is in the unloaded position, and the pressure inside both chambers are ~760 Torr. 1. Turn on the computer monitor, and open the WinCVD program and select your recipe. You will need to turn on the burn box to begin (recipes will not run unless burn box is over 700 C). Set Burn Box Temp to 800, and Burn Box Power to 90%. Let this warm up before you run any recipe. 2. Open the door to the loading chamber to load your samples. Gently remove the quartz boat, and load your samples on the boat. Be careful to gently place the quartz boat back onto the loading arm. Lock the loading chamber door. 3. Using the key, open the bottom panel (under the loading chamber), and make sure to pull out the white alarm knob. Turn on the vacuum and verify that the pressure gauge reads ~ 23. 4. When your sample is ready to be loaded, press the load sample button on the CVD panel. At this point, make sure to hold the chamber door closed, and verify that the system is pumping down on the loading chamber. After the chamber reaches 5 x 10-2 Torr, the system will purge back to atmosphere with N2. Then, the sample should automatically be loaded into the growth chamber. 5. After the sample is fully loaded, turn off the vacuum pump, and close and lock the panel door. 6. Go into service chase and verify that all necessary gas cylinders are open, and that the chiller is running. (Call Phi before you run the furnace so he can turn on the gases and adjust any of the pressure regulators. If any of the gases still need to be turned on, contact Phi). 7. After the burn box reaches a temperature above 700 degrees, you can begin the recipe. To start the recipe, in the CVD program click Reset!. This should start the recipe and an alarm will sound. Silence the alarm, and reset the alarm. 8. The system will begin to pump down the growth chamber in order to check for leaks. Verify that the system pumps down to 500 mtorr after it cycles through the pump-down leak-back sequence. If the system passes this criterion, the recipe will start.

11 9. While the recipe is running monitor and verify pressures, flow rates, and temperature. 10. After the recipe is fully complete (furnace cooled down to 200 C, and pressure back to ambient), unload sample by pressing Unload Sample button. 11. When sample holder is fully moved back to the loading chamber, open chamber door and remove samples (again remember to use care when moving quartz boat). 12. Close chamber door. 13. Go into manual mode and set Burn Box Temp and Burn Box Power back to 0. After burn box drops below 700 C, silence alarm. 14. Contact Phi to close all gas valves. 15. Verify that both chamber pressures are around ambient pressures, flow rates for reaction gases are 0, and temperatures are near room temperature. 16. Close program and shut off monitor.