User Information Sheet 013

Similar documents
5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Summary of the MRA LPG Codes of Practice

User Information Sheet 024

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

LEAK SEALING SYSTEMS

RegO Adapters, Connector, & Fittings

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

Section 7 : Supplements

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

Using propane cylinders safely

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

CA10S, CA14 and CA14S Air and Gas Traps

Handling and Storage of Gases

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Instruction sheet for Hydraulic Cylinder

Dri-Line Mk3 Monnier Compressed Air Drain Trap

MANUAL GAS MANIFOLDS

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

User Instruction Manual

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

G7S Hand Pump Owner s Manual

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Hygienic Bubble Trap Installation and Operations Manual

PC3_ and PC4_ Pipeline Connectors

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

GUIDELINES. Systems. Pressure

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

Types 749B and R130 Changeover Manifolds

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

V-24 OXYGEN LANCE VALVE

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

APT14, APT14HC and APT14SHC Spares 2

WARNING: FOR OUTDOOR USE ONLY

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Safe Work Instructions For Oxygen Acetylene Equipment

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

1200B2 Series Service Regulators. Instruction Manual

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Pressure Regulators. Instructions for Use

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

OPERATING INSTRUCTIONS AND PARTS LIST HAND OPERATED LPG PISTON PUMP WITH SCALE 301-DH-SP

Rejuvenation Instructions

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

BCV31 DN20 - Blowdown Control Valve

Atmospheric relief valve type 1100 Installation and maintenance instructions

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Warning: NEVER ALTER TEST EQUIPMENT

Rubber Dock Hose care, Use & Maintenance

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

WHEATLEY Series 500 Swing Check Valve

INSTALLATION INSTRUCTIONS for Filling and Transfer Kits including 2nd cylinder Connection Hose

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

Training Program 1A Filling 1 lb. Refillable Propane Cylinders

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

INSTALLATION AND OPERATION INSTRUCTIONS

Model PSI Compressor with 3-Gallon Air Tank 12VDC

DBML-60/80 Squeeze Tool

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

User Information Sheet 028

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

ENERGY BLADE 3K4. Energy Blade Installation Instructions

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Hydraulic Piston Accumulators

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Air Tractor Preventative Maintenance Manual And Troubleshooting

Installation and Operation Instructions

MFP14-PPU (Vented) Automatic Packaged Pump Units

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

200 PSI COMPRESSORS - MODEL NUMBERS

Transcription:

User Information Sheet 013 Formerly LPGA Technical Memorandum NO.81 Issue 2 September 2007 ACME threaded couplings 1 INTRODUCTION ACME threaded couplings/end fittings are widely used for LPG transfer operations where hoses are used. 2 GENERAL 2.1 Design ACME threads should conform to class 2G of American Standards Association Specification B1.5. Coupling dimensions (including seals) are given in BS EN 14422. To maintain an Industry standard and minimise the use of adapters, couplings for liquid fill and vapour balance connections for commercial butane and commercial propane should be one of the types and sizes indicated below. Liquid 3¼ ACME (M) R.H. x 6 TPI 2¼ ACME (M) R.H. x 6 TPI 1¾ ACME (M) R.H. x 6 TPI Vapour 2¼ ACME (M) R.H. x 6 TPI 1¾ ACME (M) R.H. x 6 TPI 1¼ ACME (M) R.H. x 5 TPI 1¼ ACME x 5 TPI couplings are used for some liquid offtake cylinders. The dimensions are given in BS EN 15202. Vapour balance couplings should not be used on liquid connections. The fixed coupling should be a male coupling and the coupling on the hose female. The vent hole in the male coupling should point downwards. To prevent inadvertent connection of commercial LPG, couplings for un-odorised LPG should have left hand ACME threads conforming to one of the above sizes. Page 1 of 5

3 USE 2.2 Fittings associated with bulk LPG transfer Fixed couplings should be protected by a manually operated shut-off valve or by an automatic valve linked to a site shut down system. Where a storage vessel is to be filled on a regular basis by a single supplier then the fill coupling should be the same size as the coupling on the tanker delivery hose. Where the use of an adapter is unavoidable only one single adapter should be used. 2.3 Fittings associated with the filling of cylinders for Mechanical Handling and Maintenance Equipment The fill coupling should be positioned so that it can be connected easily from ground level. The filling coupling on the vehicle should incorporate a non-return valve. (LPGA Code of Practice 30 Gas Installations for Motive Power on Mechanical Handling and Maintenance Equipment gives further guidance.) Suitable hand and eye protection should be worn when connecting and/or disconnecting couplings. ACME threaded couplings are rugged but they can be damaged through misuse. Both male and female couplings will eventually wear and require replacement. Dropping or dragging hose couplings should be avoided. This may damage them or introduce dirt which may cause wear on threads or prevent the functioning of safety devices. Female couplings should never be tightened by hitting the lugs (e.g. with a hammer or the coupling cap) as this can cause excessive thread wear, stretching of the threads or even fracture the coupling. Before connecting a visual check of both parts of the connection should be carried out. If threads appear to be damaged or worn, the coupling should not be used until it has been inspected in accordance with 4. Page 2 of 5

The seal is made by compressing a seal or O ring between the two parts of the coupling. The seal should be checked prior to each connection and replaced as necessary. It is good practice to keep spare seals readily available. More than one seal should never be used in a coupling. The hose coupling should be held in line with the male coupling so the female threaded ring will turn easily onto the male thread. Misalignment and stress on the connection when tightening increases thread wear. Particular care should be taken for larger sizes and heavier hoses, The two halves of the coupling should make a leak free connection without the use of excessive force. This should be achieved by hand tightening although an appropriate wrench may be used for 2¼ and 3¼ couplings. After connection the hose end valve should be opened slowly and the connection checked to confirm it does not leak. If the connection leaks when tightened in the proper manner then the associated isolation valves should be closed, the coupling depressurised and disconnected for further examination of the seal and the metal sealing surfaces for dents. Damaged or leaking couplings should never be used. On completion of the LPG transfer, the associated isolation valves should be closed and the pressure released from the coupling before disconnection. The preferred method of relieving the trapped pressure is to use a bleed valve or self venting hose end fitting. On some couplings pressure release can only be achieved by undoing the female coupling half a turn. Covers, dust caps or plugs should be used to protect the couplings when they are not in use. 4 INSPECTION 4.1 General To detect damage, thread wear beyond acceptable limits and the need for replacement seals, regular inspection of couplings and adaptors should be carried out. This should be a visual inspection of the coupling for wear and damage together with a thread dimensional check. It is not sufficient to use only a No Go gauge to check the threads as this may not identify worn or distorted threads. The results should be recorded in accordance with a schedule drawn up by a competent person. Page 3 of 5

Pressure testing is not a suitable method of inspection. The nature and frequency of the inspection should be appropriate to the design, materials of construction and duty of the couplings involved but should not, in general, be less than once a year for plant, hose and tanker couplings. A greater frequency should be considered where couplings: are subject to a high frequency of connection/disconnection ( e.g. mechanical handling and maintenance equipment); are subject to dropping or dragging or other mishandling which may cause damage; are associated with the filling of cylinders. A lesser frequency may be considered where couplings are fitted to bulk storage tanks at consumer premises which are filled less than five times a year. In this case a visual inspection at the time of filling with a gauge and/or measurement inspection every ten years may be considered. UKLPG Code of Practice 14 (Hoses for the transfer of LPG in bulk Installation, Inspection, Testing and Maintenance) gives guidance on hose assemblies. 4.2 Visual Examination Visual examination should be carried out with particular emphasis on: Narrowing or distortion of the thread form; Cracks, dents, bulges cracked or broken threads (any of which may weaken the fitting); Worn threads with a stepped appearance (see below); Other uneven wear of the threads; Debris in the threads; Excessive corrosion or pitting; particularly of steel threads; Damage or distortion of the internal cone on a female vapour balance coupling; Damage to or absence of the pin on male vapour balance coupling; Damage to the lugs of female couplings (if the lugs of female coupling have been damaged this may prevent the use of the correct wrench and may indicate a stretched thread); Damage to the elastomeric seal of male couplings; Damage to the sealing face of the female couplings. Page 4 of 5

4.3 Mechanical Examination Visual surveys of ACME threads may not always show potentially dangerous conditions. The majority of thread wear occurs above the thread pitch diameter, standard GO/NO GO gauges may not identify this. Special ACME thread wear gauges are designed with a thread wear allowance. If these gauges can be threaded more than one turn onto (or into) an ACME coupling, this indicates unacceptable thread wear of the coupling. ACME thread gauges may not start on couplings where the thread is distorted (e.g. not circular). A coupling failing an inspection should not be used and should be replaced. Page 5 of 5