Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

Similar documents
Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Skin and Vein Replacement Kit LF01122U (Light Skin) LF01123U (Dark Skin) LF01124U (Vein) Instruction Manual

Peripheral Venous Catheter Placement Simulator

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

The Butterfly. Steep Trendelenburg Gel Bean Bag Positioner USE & CARE GUIDELINES DAVID SCOTT COMPANY

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

Nita Newborn Model 1800 User Manual

Skin and Vein Replacement Kit LF01122 (White Skin) LF01123 (Black Skin) LF01124 (Vein)

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL

Chester Chest Model 2400 User s Manual

Chester Chest Model 2400 User s Manual

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Patients Guide for Self Administering Intravenous Antibiotics General points

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Information for patients and nurses. Rocket Ambulatory Chest Drain

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Infant IV Leg LF03636U Instruction Manual

INSTRUCTION MANUAL Elisa Baby-PICC

Advanced IV Hand LF01139U & LF01146U Instruction Manual

Child CRiSis Injectable Training Arm LF03612U Instruction Manual

Parts identification:

Veterinary Science Handling and Restraining Practicum. Restraint of the Cat for Cephalic IV Catheter Placement

Ultrasound Guided Thoracentesis Simulator

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

AT Kelly Torso. Directions for Use

Installation Instructions

INSTALLATION INSTRUCTIONS

Training Device Instructions

MAINTENANCE PROCEDURE FOR X 650

CamRT Sun Top Bimini Installation Instructions

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Drive Belt Instructions

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Installation Instructions

REDMAN SUIT ASSEMBLING AND PACKING INSTRUCTIONS

THE AMBROISE DYNAMIC WRIST ORTHOSIS

AT Kelly Torso. Directions for Use

Venous Blood Collection Passport

Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual

Read through all the steps first before working on the camera. Make sure you know what to do.

Patient Sleep Test Hookup

Underwater Housing for Canon EOS M

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Date Effective: Date Reviewed: Nebraska Biocontainment Unit. Doffing Biological Protective Suit and PAPR

Airway Larry Airway Management Trainer Head LF03667U Instruction Manual

RS Important Notes. Contact. Bicycle Maintenance Stand instructions manual. Warranty Period : 1 year (from the date of your purchase)

CVC Insertion Simulator

Techcon Systems TS1258 Pressure Pot

Alfred ECMO Circuit Priming and Storage Guide

A designated area will have been assigned for all blood specimens to be taken. All blood should then be taken in that area only.

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

LABORATORY TECHNIQUES. Pouring Liquids

MMR Air Mask With. with Quick-Connect Hose

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Port - Body in a Box User s Manual

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Grow to Pro Basketball

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Instructions For Use. Elastomeric Infusion Device

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

SANTANA STOWAWAY TANDEM WITH AIRLINER SAFECASE AND FTS FOAM TRAY SYSTEM ASSEMBLY AND DISASSEMBLY

UltRo Dual Flow Reverse Osmosis Water System

INTERMEDIATE INFANT MANIKIN LF03700U INSTRUCTION MANUAL

Instructions for Use (IFU) Electrical Leg- & Arm lift, model , ver. 2012

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Vacuum Bagging Wings Instruction Manual Purdue University

Infant ECG/Umbilical Cannulation Skin LF03710U Instruction Manual

INFANT INJECTABLE TRAINING LEG LF03636U INSTRUCTION MANUAL

Table of Contents. Introduction 2. Airway Management Trainer 3. IV Arm 4. IV Leg 9. Intraosseous Infusion Leg 14

CHILD DEFIBRILLATION CHEST SKIN LF03611U INSTRUCTION MANUAL

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

RG1200 Service and Repair Manual

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

Venepuncture. Clinical Skills. Venepuncture. Dr Brian Jenkins (Clinical Skills Lead) Sian Williams (Clinical Skills Manager)

Ebola Virus Disease PPE Checklist/Sign In-Out Sheet Higher Transmission Risk Option 2: PAPRS

Santa Fe Cycles Assembly Guide Introduction

FireHawk M7 and FireHawk M7XT Control Modules

AIRWAY MANAGEMENT TRAINER LF03601U INSTRUCTION MANUAL

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

OWNER S MANUAL ALWAYS WEAR A GOVERNMENT APPROVED FLOATATION DEVICE WHEN FISHING. Know the limits of your ability and the limits of your equipment.

Basic Install Guide. Parts: 1 P a g e

MAGNETIC INDOOR CYCLING BIKE

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

Ultrasound Guided Thoracentesis / Pericardiocentesis Simulator Full set

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

CHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U

Usage and Care Instructions

NASG APPLICATION. Applying the NASG

Transcription:

Setup Guide Bag & Stand Advanced Standard Light. Part No: 00440 Brown. Part No: 0044 Black. Part No: 0044 Part No: 065-0 Issue, May 0 0 Limbs & Things For more skills training products visit limbsandthings.com Limbs & Things Ltd. Sussex Street, St Philips Bristol, BS 0RA, UK sales@limbsandthings.com +44 (0) 7 0500

Bag & Stand Advanced - Light Part No: 00440 This product provides the ideal platform for all healthcare trainees needing to practise the skills related to venepuncture and IV cannulation. Designed with durability, realism and ease of use in mind, this product addresses the fundamental needs of clinical skills tutors, trainees and technicians alike. 4 Improvements Skins are more durable Veins last longer (up to 500 insertions of g needle) Blood has been reformulated to improve leak resistance of veins Arm allows for digital pressure to stem blood flow Infusion Tube allows for volume IV fluids to be administered Skills Venepuncture IV Cannulation IV Infusion Features Veins are long lasting and are easy to replace Can be used with vacuum blood collection systems Realistic blood flashback Realistic, soft, flexible skin and underlying palpable veins Easy to clean, service and maintain Accessible veins: dorsal metacarpal, cephalic, basilic, and median cubital are easy to replace Can be adapted for professional-to-patient communication (role play) using Harness Part No: 0000 Package supplied Skin - Light Part No: 009 AV Arm Vein Part No: 009 AV Vein Module Part No: 0095 Bag & Stand Mock Blood Supply Part No: 006 Concentrated Venous Blood - Starter Pack Part No: 0000 Infusion Tube Part No: 005 Rest Part No: 000 sachets of water-based lubricant arm shell Get an assistant to support the Arm whilst the Harness is placed over the right shoulder and the chest strap is clipped together and then loosely tightened. Raise the right arm and securely fix the velcro strap around it. Hold the Arm and comfortably tighten the chest strap so that the Harness cannot move. Set up your training scenario. 0

Using the AV Arm Harness (Optional extra) Bag & Stand Advanced - Brown Part No: 0044 As per the Bag & Stand Advanced - Light. Package supplied (where different) Skin - Brown Part No: 0099 Bag & Stand Advanced - Black Part No: 0044 As per the Bag & Stand Advanced - Light. Package supplied (where different) Skin - Black Part No: 0097 Important: handling & hygiene The AV Arm Harness allows for role playing to be carried out. It is available as an optional accessory. Order Part No: 0000 The AV Arm Harness is designed to fit over the right shoulder and upper arm. The Harness has a mounting point to which the Arm is attached. Insert the mounting point into the end of the Arm...... and rotate the Arm until it is screwed fully onto the mounting point. Venepuncture training is a potentially messy process so always set the product up on a wipe clean surface. The instructions supplied in this User Guide are designed to minimise the risk of any spillage. Even so, it is a good idea to keep paper towelling close to hand just in case. Do not wear good clothes when training with this product. If concentrate or Mock Blood gets onto clothing it should be immediately flushed with water to avoid permanent staining. Any remaining marks will come out using a biological detergent. If concentrate or Mock Blood gets into the eyes flush with plenty of cold water. Observe normal hygiene procedures after handling the product. 0

Components 4 5 6 Skin - Light Part No: 009 Skin - Brown Part No: 0099 Skin - Black Part No: 0097 Rest Part No: 000 095 AV Arm Veins Part No: 009 (With adhesive fastening strips) Concentrated Venous Blood - Starter Pack Part No: 0000 Attach the top veins and push the transparent tubes back into the arm so that the connectors fit snugly. Fit the veins into the grooves and wrap the supplied tape around the upper ACF area to hold them in place. Get another person to help you if necessary. Attach the palm connector and push the transparent tube back into the arm so that the connector fits snugly. Fit the veins into the grooves of the forearm and tape them in place. Ensure that the veins around the hand fit in the grooves correctly. Tape the vein into the thumb area. Settle the veins into the grooves correctly. The arm is now ready to have the skin fitted. Bag & Stand Mock Blood Supply Part No: 006 Infusion Tube Part No: 005 0 9

Changing the Veins Storing the Arm (Depending on version bought) Cardboard box Case: top layer Case: bottom layer IMPORTANT Before changing the veins follow the procedures Emptying the Veins (page 5) and Removing the Skin (page 6). Remove and discard the strips of tape running around the thumb, wrist, and the upper ACF area. (New tape is supplied with the replacement veins). Disconnect the upper connectors first. Gently pull the lower connector out of the palm. Hold the transparent tube and pull the vein out from it. Remove the vein and discard it. Avoid spilling any residual blood left in the veins. Lay the new vein on the work surface in the correct position ( veins at the top, small hand veins at the bottom and the slant of the median cubital matches the groove in the vein module). The Bag & Stand is stored underneath the cardboard insert. The Carry Case is an optional extra. Bottom layer has additional storage for accessories. 8

Setting up the Fitting the Skin Place the base on the work surface. Screw together the two parts of the Stand. Push the Stand through the collar and into the hole in the base. Tighten the red knob. Hang the Bag on the hook. Push the pressure tube attached to the Bag lid into the black plastic clips. Avoid any kinks in the pressure tube by making sure that there is large u-bend at the top. To make the Skin easier to attach, lubricate the arm with the supplied waterbased lubricant. Ensure that the hand, forearm and upper arm are well lubricated. Align the Skin with the underlying anatomy of the arm. Gently work the Skin up the arm. Pull the fingers onto the hand. Slide the Skin up to the top of the arm. Ensure that the ridge around the inside engages with groove at the top. If necessary, slide the Skin around slightly so that it fits the arm anatomy properly. 7

Removing the Skin 4 5 6 Using both hands, roll the upper part of the Skin down over onto itself as far as it will go. Do not force the Skin. Fold the Skin down over onto itself again. Gently pull the Skin down onto the wrist. Gently pull the Skin off the wrist and onto the hand. The hand should gradually go floppy as the Skin is worked off the arm. Once most of the Skin is off the arm, hold the Skin by the upper part...... and remove it. Place the Arm in position on the Arm Rest. Fill the Concentrated Venous Blood - Starter Pack with water up to the level indicated on the label. Tightly screw on the cap and gently invert the Starter Pack 5 or 6 times to thoroughly mix the contents. Do not shake. The Mock Blood is ready to use. When properly mixed there should be no dark streaks of concentrate visible on the sides or bottom of the Starter Pack. You may want to use a funnel or to decant the blood into a jug when pouring it into the Bag. Hold the Bag lid down with your thumb and carefully pour the blood in. For safety, leave the Bag hooked onto the Stand whilst doing this. Close the top of the Bag and make sure the lid is sealed. 6

Emptying the Blood Bag and Veins 7 8 9 Connect the black sleeved tube on the Arm to the black sleeved fluid feed on the bottom of the Bag. Connect the other tube on the Arm to the pressure tube attached to the Bag lid. The veins will start to fill. The process takes about a minute. Ensure that the connectors are level...... by gently raising or lowering the pressure tube. When the blood in the pressure tube has settled, check that the level of it matches that of the blood in the Bag. If the levels do not match there may be air bubbles in the veins or tubes. Raise the shoulder end of the Arm to allow any trapped bubbles to rise up and into the pressure tube. Tapping the Arm and tubes with your finger will help to dislodge air bubbles. Place the Starter Pack on the floor near the Arm. Check that the Infusion Tube will easily reach from the Starter Pack to the Arm. Insert the end of the Infusion Tube and push it down to the bottom of the Starter Pack. Leave the tube on the floor. Note: the Infusion Tube may be cut down to a more suitable length if required Disconnect the Arm tube from the pressure tube attached to the Bag lid. Carefully pick up the loose end of Infusion Tube and connect it to the Arm. Make sure that the other end of the Tube is still inside the Starter Pack. The blood will now drain out into the Starter Pack. This will take several minutes depending upon how much blood is in the Bag. When all of the blood has drained, carefully remove the Infusion Tube from the Starter Pack and wipe the remaining blood from it. Tap the end of the Tube to dislodge any blood remaining in it. If the Arm is not to be used for a long period of time, flush the system through by filling the Bag with water and repeating Stages to. Replace the Starter Pack with another container big enough to hold the water. 4 5