Nikuni KTM Series Pumps

Similar documents
Nikuni KTM Series Pumps

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

T Y P E V S A B M S E W A G E P U M P

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

STAINLESS STEEL GRAND SERIES

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

RP series Rotor Pumps

Operating Instructions Models and Hydrostatic Test Pumps

50Hz. water solutions. O SerieS DGO DRO

Operating Instructions Model and Hydrostatic Test Pump

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Operating Instructions Models and Hydrostatic Test Pumps

Size 6 up to 31.5MPa 1) up to 25 L/min

Proper Pump Installation Practices

Operating Instructions Models and Hydrostatic Test Pumps

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

2 I All-Flo Pump Co.

SIHI LPH-X - Liquid Ring Compressors

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Dean Pump Self-Priming Chemical Process Pumps

VACUUM REGULATORS CONTENTS

Industrial TE-5.5-MD-CK. Applications. Features. Construction

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Direct Operated Precision Regulator Modular Style. Standard Specifications

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

IFS NUVENT SERIES IWF FOR POTABLE WATER ANTI SLAM AIR RELEASE AND VACUUM BREAK AIR VALVES

Iwaki magnetic drive pumps CAT -E

Fixed Displacement Pump KFA for commercial vehicles in open circuits

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

Accessories. Valves. Adjustable Pressure Relief Valves

Turbo Blowers. Combustion Excellence Since Features. Benefits

Spare parts list ( ) Spare parts list HD 2.3/15 C Ed/ 3.0/20

Industrial Filter. FGD series

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food

ELADOS EDP L Diaphragm Metering Pump Type

Operating Instructions

Air Operated Hydraulic Pumping Systems to 50,000 psi

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

OWNER S TECHNICAL MANUAL

Corken, a tradition of excellence

GROUTEC SCOTT VICKERS. Grouting Equipment

PVQ 13 A2 R SE 1 S 20 C-11 D

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Power Valve: Precision Regulator. High precision, large capacity relief regulator

SM Models Manual Control

60HZ XIANDAI PUMP. CDL/CDLF Vertical Multistage Pump ZHEJIANG XIANDAI PUMP CO.,LTD. ZHEJIANG XIANDAI PUMP CO.,LTD.

Deep Well Submersible Pump Model MSU/MSUS

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Installation and commissioning instructions 255 series and 256 series

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Liquid ring compressor

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Series IRV1000/2000/3000

PK-2D Service Manual

ALF400 to 900, ALT-5/-9

HPB25 Hydraulic Paving Breaker

EXH. Specifications. Descriptions. Min. working pressure MPa

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

UCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SM Models Manual Control

LMU100/200 Series. Standard Specifications

Nitrogen Tyre Inflator Owner s Manual

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

FIREFIGHTING EQUIPMENT

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

2 I All-Flo Pump Co.

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

SELECTION & APPLICATION

Operating Instructions Model and Hydrostatic Test Pump

INSTALLATION AND OPERATION INSTRUCTIONS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

PULSAR4 Pressure regulating valve (Unloader)

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

USER MANUAL. MACMAG magnetic separator MHK MHF

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

INSTALLATION INSTRUCTIONS

Liquid ring compressors

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Transcription:

Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM5S3- (SS34 material) Date : Doc. No. : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi, Kanagawa, Japan Post-code 213-32 URL : http://www.nikuni.co.jp Phone: +81-44-833-65 (English) +81-44-833-1121 (Japanese) Fax : +81-44-833-6482

MAIN OFFICE : 843-5 KUJI, TAKATU-KU, KAWASAKI, KANAGAWA, JAPAN 21332 TEL : +81()-44-833-65 FAX: +81()44-833-6482 NIKUNI BUBBLE GENERATOR FOR DAF SYSTEM NIKUNI KTM (DAF) PUMP DATA SHEET Company Date -Jan-19 Project Data sheet No. Service Rev. Item No PID No. No.Operating No.Spare Total Required Pump Model KTM5S3- (SS34 material) Pump Type Coupling Type (Base plate, Coupling set & Coupling guard only) PROCESS AND PERFORMANCE DATA Conditions of Service, Each Pump Fluid Treated Water Design Capacity (L/min / gpm) / Normal Capacity (L/min / m3/hr) 25 / 15. Suction Press. (MPa / bar) -.3 / -.3 Temperature ( ) Disch. Press. (MPa / bar) / Specific Gravity (at P.T.) Differential Press. (MPa / bar) / Viscosity (at P.T. MPa s) Total Head (m / bar) 3 or 4 / 3 or 4 Air Flow rate (NL/min / Nm3/Hr) 2 / 1.2 Differential Head (m / bar) NPSH Ava. (m) NPSH Req. (m) Motor Driver *Electric motor should be prepared by purchaser Phase Output (kw / HP) 11kW / 15 HP Frequency 5 Hz Voltage Pole 4 Speed 15 min-1 Type * Original base plate will be fixed to IEC Motor frame size 16M. Connection (Suction.) Size 5 A Rating JIS 1K (Discharge.) Size 5 A Rating JIS 1K Materials (Wetted parts) Casing SCS13 Shaft SUS34 Cover O-ring PTFE Impeller SUS34 Side plate N/A Slinger NBR Cover SCS13 Mechanical Seal Sic - Sic, PTFE Painting MUNSELL N3 Remarks Accessory : Air In-take nozzle. Please refer to attached recommendation of the air-parameter & gauges ranges and other accessories. REV. DATE COMMENT DESCRIPTION DRAWN BY CHECK BY APPROVED BY

MODEL:KTM5S1,S2,S3 5Hz Dimension *3 (125) *2 (4) *1 (4-M1) Note: 1. For KTM5S3 *1 : M12 *2 : 4mm *3 : 15mm *4 : 38mm *4 (31) Coupling Dimension for KTM5S(F)1, S2(F2) & S3(F) Coupling Dimension (unit:mm) kw A B C D E F SS 5.5,7.5 45 45 9 38 41.3 1 24 11,15 55 55 12 42 45.3 12 4 Applicable motor frame size for Original base-plate. kw IEC Frame 5.5 132S 7.5 132M 11 16M Demension & net weight 15 16L Unit:mm Model Kw HP S D PR PY FA FB FS FC MH L MA MR SS VE VF VM VN VS VT VZ KL Weight KTM5S1 5.5 7. 5A 5A 285 16 13 55 15 23 24 836 21.5 239 24 324 448 352 69 121 2 12 189 9 KTM5S2 7.5 1 5A 5A 285 17 13 55 16 24 24 874 229.5 258 24 324 448 352 69 121 2 12 189 11 KTM5S3 11 15 5A 5A 285 17 13 55 169 24 245 127.5 32 323 4 368 614 44 878 132 2 15 257.5 125 *Approx. Packing weight (Motor weight not included) Sectional Drawing Material No. NAME OF PARTS SET MATERIALS 21 Ball Bearing 1 SUJ 22 Ball Bearing 1 SUJ 25 Bracket 1 FC2 27 Bearing Gland 1 51 Mechanical Seal 1 SiC - SiC 74 Key 1 S45C 81 Slinger 1 NBR 12 Casing 1 13 Cover 1 17 Impeller 1 SUS34 18 Shaft 1 SUS34 113, 114 Key, washer & nut 1 SUS34 116 Impeller Key 1 123 Cover O-Ring 1 Copyright 212 All Right Reserved Nikuni Co., Ltd.

PC-KTM5S352 PUMP SUPPOSITION CURVE 5Hz Model KTM5S3 NPSHreq.(m) 7 6 5 4 3 2 1 12 NPSH 5 1 15 2 25 3 35 4 45 5 6 11 55 1 9 Total Head 5 45 8 4 Total Head(m) 7 6 5 Effect 35 3 25 Effect(%) 4 2 3 15 2 1 1 5 Output(kW) 5 1 15 2 25 3 35 4 45 5 16. 14. 12. Output 1. 8. 6. 4. 2.. 5 1 15 2 25 3 35 4 45 5 Capacity(L/min) NIKUNI Co.,Ltd.

Accessories Air Intake Nozzle (Included in every package ) How to connect the nozzle to Air Flow Meter (Air Intake Nozzle will be attached to every pump) L1 L1 Applicalbe Model (Standard) Dia. (E) Length (L1) Length (L2) Length (L) Dia. (D) KTM15 (F)(N)(D) R 3/8 B 121 73 157 R 1/4 B KTM2 (F)(N)(D) R 3/8 B 121 88 162 R 1/4 B KTM25 (F)(N)(D) R 3/8 B 121 97 167 R 1/4 B KTM32 (F)(N)(D) R 3/8 B 121 114 172 R 1/4 B KTM4 (F)(N)(D) R 3/8 B 121 12 177 R 1/4 B KTM5 (F)(S)1,2,3 R 3/8 B 129 21 268 R 1/4 B L2 Standard Type L2 Large-scaled Tpye Applicable Model (Large-scaled Type) Dia. (E) Length (L1) Length (L2) Length (L) Dia. (D) KTM65S2 / F2 Rc 3/8 183 24 34 Rc 3/8 KTM8S / F Rc 3/8 193 24 319 Rc 3/8 * In case of KTM8S / F model, connect E part with Bushing (3/4 x 3/8) 1) Loosen the nuts of the lower pipe joint to allow a nipple to freely move. 2) Mark the pipe bending direction on the pipe surface between the upper and lower pipe joints. 3) Wind a sealing tape around the lower pipe joint s nipple of the suction nozzle, insert it into the nozzle junction of the pump, and turn the nipple to firmly fix it. 4) Turn the pipe to align the mark on the pipe surface so that the bend nose (gas discharge port) of the pipe will be directed to the center of the impeller. 5) Tighten the nuts of the lower pipe joint firmly. Make sure that the suction nozzle is not manually rotated. 6) Rotate the motor manually (rotate the shaft end of the motor with a screwdriver) to make sure that the pipe nose of the nozzle is not interfering with the impeller. Noted : Fitting connections & Air Flow meter should be prepared by purchaser Air In-iake Nozzle will be attached to every pump Recommended Accessories (To be prepared by Purchaser) Air Parameter Guages Compound Guage Minus.1 MPa to +.25MPa Minus 1. Bar to + 2.5 Bar Minus 15psi to + 35 psi Pressure Guage MPa to + 1.MPa Bar to + 1 Bar psi to + 15 psi Operation air flow rate & Air Parameter ranges 5Hz Frequency 6Hz Frequency Applicalbe Model (Standard) Water Flow Rate m 3 /Hr x 4Bar Operation Air flow rate (NL/min) Air Flow Meter Range (NL/min) Water Flow Rate m 3 /Hr x 4Bar Operation Air flow rate (NL/min) Air Flow Meter Range (NL/min) KTM2 (F)(N)(D) 1. 1.3 to 5 1.3 1.7 to 5 KTM25 (F)(N)(D) 1.5 2. to 5 2.5 3.3 to 5 KTM32 (F)(N)(D) 3. 4. to 1 4. 5.3 to 1 KTM4 (F)(N)(D) 4.8 6.4 to 1 7. 9.3 to 2 KTM5S1 / F1 8. 1.6 to 2 11.5 15. to 3 KTM5S2 / F2 12. 16. to 2 15. 2. to 4 KTM5S3 / F3 15. 2. to 3 18. 24. to 4 KTM65S2 / F2 2. 26.6 to 4 28. 38. to 6 KTM8S / F 42. 56. to 8 58. 78. to 1 Copyright 212 All Right Reserved Nikuni Co., Ltd.

Excess Air Device / Separation Tank The KTM Series pump user manual must be fully read and understood before operating the pump. Failure to do so may result in death, serious injury, or property damage. This page is intended for a basic understanding of the KTM startup operation and is not a substitute for the user manual. PRE-OPERATION CHECK (POWER OFF) 1) Prime KTM with effluent or water 2) Fully open Suction valve and Discharge valve. Do not run KTM with these valves closed. STARTING THE KTM 1) Discharge side adjustments: Slowly tighten the Discharge valve until the discharge pressure falls within the desired range of.3mpa to.4mpa (approximately 3 bar to 4 bar) with reference to the Pressure gauge. In the case where the Discharge valve (or KTM) is located far from the flotation tank, bubbles will tend to grow larger. In order to maintain microbubble size, an additional control valve should be installed on the flotation tank side to control the discharge pressure. 2) Suction side adjustments: Check to see if the Compound gauge indicates a negative suction pressure between the range of -.2MPa to -.3MPa (approximately -.2 bar to -.3 bar). If the pressure is higher than this range, slightly tighten the Suction valve to bring the pressure into the range stated above. 3) Air injection adjustments: Open the knob of Air-Parameter (Air flow meter) and adjust to an air flow rate that is 8% of the water flow rate. AIR FLOW METER AIR IN-TAKE NOZZLE ( ATTACHED WITH EVERY PUMP) COMPOUND GUAGE FROM FLOTATION TANK (TREATED WATER) SUCTION CONTORL VALVE KTM PRESSURE GUAGE TO FLOATATION TANK DISCHARGE CONTORL VALVE KTM (KARYU TURBO MIXER) NOTES : KTM & AIR IN-TAKE NOZZLE WILL BE SUPPLIED BY NIKUNI OTHERS ACCESSORIES CAN SUPPLY AS OPTIONAL CASE. In case of mini bubbles occur and effect to flotation process, please consider installing Excess Air Device / Separation Tank as shown in next page. Copyright 212 All Right Reserved Nikuni Co., Ltd.

Excess Air Device / Separation Tank Reference P&ID for DAF System Wastewater Influent Treated Water Excess air release Excess Air Device / Air Separation tank Air Pressurized Water To Flotation Tank KTM To KTM Recommended Separation Tank Capacity (B) Excess Air Release (Install a contorl valve as to adjust the release of air amount) ( A) Model A (mm) B (mm) Capacity (Liter) KTM2N(F)(D) 1 26 2 KTM25N(F)(D) 12 35 4 KTM32N(F)(D) 26 4 2 KTM4N(F)(D) 26 4 2 KTM5S(F)1,S(F)2,S(F)3 3 85 6 KTM65S(F)2 45 9 14 KTM8S(F) 45 9 14 Pressurized Water Outlet Pressurized Water Inlet Copyright 212 All Right Reserved Nikuni Co., Ltd.