KJL-205A. Operation Manual YOU MUST READ THIS MANUAL BEFORE USE

Similar documents
DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE

YOU MUST READ THIS MANUAL BEFORE USE

INSTRUCTION MANUAL. DIGIVAC Model 801 Series. Digital Vacuum Gauge. 801W Ranges to 760 Torr 1 to 9999 microns.001 to 999 millibar

INSTRUCTION MANUAL. Digivac Model 276. Digital Vacuum Gauge. Digivac Models Model Ranges.001 to 760 Torr.001 to 1013 millibar

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges

INSTRUCTION MANUAL. DIGIVAC Model 200 Pirani. Digital Vacuum Gauge Revsion K13A YOU MUST READ THIS MANUAL BEFORE USE. Readings from millitorr

105 B C h u r c h S t, M a t a w a n, N J s a l e d i g i v a c. c o m w w w. d i g i v a c. c o m Copyright 2015,

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

YOU MUST READ THIS MANUAL BEFORE USE

DPC-30 DPC-100. Reference Manual

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Instruction Manual BA90 Precision Barometer

Columbus Instruments

INSTALLATION & MAINTENANCE INSTRUCTIONS

Digital Vacuum Regulator

TELEDYNE HASTINGS INSTRUMENTS MODEL 40 POWER SUPPLY INSTRUCTION MANUAL

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

P900. P900, Datenblatt Seite 1 DESCRIPTION

Digital Vacuum Regulator

User s Guide Temperature Sensor Converter TSC-599

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

MODEL GT820 OXYGEN SENSOR

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Covered Task 409OP Training Guide Inspecting Interference Bonds

PM105 PRESSURE METER USER S MANUAL

92831 TEL: (714) FAX:

Model 106 DPI "Micro-switch" Installation and Operating Instructions

How to specify a product. Process Sensors and Mechanical Instruments

Installation, operating and maintenance Instructions for Seemag bypass level indicator

ASDX Series Silicon Pressure Sensors

Transmitter CS 21 Operation Manual

RAM 4021 Operation Manual

UNIVERSAL MASK TEST SYSTEM

Installation and Operation Manual

92831 TEL: (714) FAX:

Precision pressure sensor Basic version Model CPT6020

OEM Manual. MODEL ½ Digit DRUM SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

PS-425 Pitot-Static/Air Data Tester

Digital Vacuum Regulator

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

BAPI Pressure Line of Products - FAQs

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

RK-IR Sample Draw Aspirator Adapter Operator s Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

[Instruments for vacuum measurement, checking and adjustment] 3

Constant Pressure Inlet (CCN) Operator Manual

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Advanced Test Equipment Rentals ATEC (2832)

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

SPECIFICATIONS APCEPH1

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

AUTO PUMP STATUS CENTER

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Research Grade Blood Pressure Transducer User's Manual

I have to say that I had no idea about compressors. That means it s easy for everybody.

ENVIRONMENTAL INSTRUMENTS, LLC

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

O3 3E 1 F Gas Sensor Module

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Transmitter CS 21 Operation Manual

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Design Features. General Description

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

210 Series Transmitter with External Electrochemical Sensor

Ocean Technology Systems ComBox

High-performance submersible pressure transmitter For level measurement Model LH-10

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

KJ1000 Operating Instructions & Parts Manual NSN

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

In Vivo Scientific, LLC INSTRUCTION MANUAL

Accu-Tab PowerBase 3012AT by Axiall Corporation

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Best Practice Guide, Servomex 2700

780S Ultra High Purity Series

700 SERIES BMS II BUBBLER MONITORING SYSTEM

QBS Electronic Pressure Regulator

Instruction Manual for Intrinsically Safe - Reed Switches

HLM-2000-TX Gas Transmitter User Manual

Deep Submersible Level Transducer Series 300DS

Transcription:

KJL-205A Operation Manual YOU MUST READ THIS MANUAL BEFORE USE

2 Table of Contents 1. Section 1: Overview... 3 2. Section 2: Quick Start... 4 3. Section 3: Installation... 5 4. Section 4: Connections... 6 5. Section 5: Set Points... 6 6. Section 6: Analog Out... 7 7. Section 7: Field Calibration... 8 Calibration Procedure... 8 8. Section 8: Troubleshooting... 8 9. Section 9: Servicing and Maintenance... 9 Gauge tube servicing... 9 Maintenance... 9 Notes on calibration... 10 10. Section 10: Accuracy... 10 11. Section 11: Specifications... 10 12. Section 12: Understanding Torr... 12 13. Section 13: TERMS OF USE, LIMITED WARRANTY & LIABILITY WAIVER... 14

3 Section 1: Overview The Kurt J. Lesker KJL-205A, is a rugged, modern vacuum measurement instrument designed to make vacuum measurement easy through the use of a familiar meter movement. Electronically, it is a highly accurate digital vacuum gauge utilizing fieldproven thermocouple vacuum sensor technology. Portable Optional all metal case protects meter movement & electronics Field-proven thermocouple vacuum sensing technology Precise Excellent intra-tube accuracy when utilizing KJL-6000SS thermocouple gauge tube Field calibratable Reliable Very simple electronics Easy to understand Features: Movement scale with range focused on the most useful range of interest for industrial vacuum: below 500 millitorr International Power supply Designed to meet CE specifications 5 Volt Analog output 24 VDC 1 Amp Type C ( common, normally open, normally closed ) relay contact Field replaceable sensor Options: KJL-205A Panel mount gauge that includes KJL-6000SS sensor, sensor cable and power supply KJL-205ANT Panel mount gauge that includes sensor cable and power supply (no sensor/tube) KJL-205ABM Bench top gauge that includes KJL-6000SS sensor, sensor cable and power supply KJL-205ABM3X Bench top gauge that includes (1) KJL-6000SS sensor, (3) sensor cables and a power supply with the ability to switch between (3) KJL-6000SS sensors. Additional KJL-6000SS sensors should be purchased as necessary.

4 Section 2: Quick Start A simple and intuitive gauge, yet modern implementation. Unpack and Confirm: verify you ve received everything you ordered The vacuum instrument contains the following components: 1. Vacuum gauge with an international power supply, and 10 of sensor cable with Octal connector 2. Thermocouple Vacuum Gauge Tube if ordering anything but KJL-205ANT 3. Quick Start guide or (this) User Manual KJL-205ABM KJL-205A Easy to use steps: 1. Plumb the thermocouple sensor into the system to be measured, taking care to keep the stem down 2. Install the display into its table top or benchtop location 3. Connect the power and gauge tube 4. Read vacuum!

5 Section 3: Installation If the KJL-205A or KJL-205ANT is purchased, it needs to be mounted. Please use the graphic below for guidance.

6 Section 4: Connections The only required connections for operations are power and sensor. The connections are already made in the KJL-205ABM and KJL-205ABM3X units that come fully installed in a metal enclosure, and there is no need to disassemble the unit. The only reason you would disassemble a KJL-205ABM or KJL-205ABM3X enclosure would be to access the analog output and relay connections. Span Adjust Set Point Set Set Point Switch Sensor Connection 5V power Calibrate mv -10mv Zero Adjust (-) Analog +Analog +10mv N.O. Comm N.C. Analog Out Adjust Section 5: Set Points This gauge is equipped with a control option where a relay is activated when the gauge falls below the set point. To set the set point:

7 Step 1. Press the set point switch. This redirects the meter movement to be controlled by the potentiometer adjustment. Step 2. While pressing the set point switch, adjust the set point adjustment until the meter movement indicates the vacuum level at which that you d like the relay to activate. Step 3. Release the switch. The relay may turn on or off a device depending on how it is wired to the type C contacts. Below is a description of type C contacts: 1. Common The common connection of a switch or circuit. 2. N.C. Normally closed. This means that above the set point value there is a current path between the common and the N.C. terminal. Put another way the switch is ON between these 2 terminals. At the set point value and below (higher vacuum, lower pressure) the connection is open. Put another way, the switch is OFF between the common and the N.C. connection at higher vacuum (a lower vacuum reading). 3. N.O. Normally open. This means that above the set point value there is no current path between the common and N.O. connection. Put another way the switch is OFF between these 2 terminals. When the vacuum indication goes below the set point value (higher vacuum, lower pressure) the current path closes. Put another way the switch is ON between the N.C. and N.O. connections at absolute vacuum readings below the set point value. Section 6: Analog Out This gauge is equipped with an analog voltage output to indicate the pressure level. This analog output uses voltage to simply communicate with PLCs, PCs and other control systems. Below are some sample readings: Volts millitorr mbar Pa 0.10 2.003 0.3 0.50 10 0.13 1.3 2.20 50.067 6.7 3.30 100.133 13.3 4.05 200.267 26.7 4.40 300.400 40 4.55 400.533 53.3

8 Section 7: Field Calibration The KJL-205 family of products can be calibrated in the field provided that an accurate vacuum instrument standard exists. Typically, that instrument standard should be 4x as accurate, or at the very least much more accurate than the KJL-205A. Calibration Procedure 1. With instrument not plugged in (not powered up), turn screw in middle of meter face (with special tool) to center needle over DOT on far right side of scale face 2. Plug in 5 volt A/C adapter, connect cable to KJL-6000SS sensor. System must be < 1 millitorr. Connect voltmeter (set to DC millivolts) to bottom two test pads labeled 10mV+ and 10 mv-. SLOWLY adjust POT R2 CALIBRATE so meter reads 10.0 mv 3. Raise pressure to 200 millitorr. Adjust POT R1 SPAN so KJL-205A indicates 200 4. Pump system to 10 millitorr. Adjust POT R4 ZERO so the KJL-205A indicates 10. Caution needed that vacuum system is holding at 10 mtorr 5. Re-check at 200 millitorr and adjust if necessary Section 8: Troubleshooting Here are a few trouble shooting steps: Observation Possible Causes Meter stays at on the right This indicates the power off state. Verify the supply is plugged into board power receptacle, and the wall adapter is plugged in. Meter stays near ATM Verify the system pressure is indeed below 1000 millitorr Verify that the tube being used is a KJL- 6000SS or DV-6 equivalent Verify sensor cable connected to controller and to tube Verify KJL-6000SS tube is good

9 Is the KJL-6000SS Sensor good? 1. Verify 18-20ohm resistance between pins 3 and 5 7 8 2. Verify 18-20 ohm resistance between pins 3 and 7 If zero ohms or open circuit is read, the tube will need to be replaced 5 3 When I first turn the unit on, it starts near ATM, then slowly moves down When I switch between sensors in the KJL- 205ABM3X, the needle starts high, then settles in to vacuum reading. This is normal operation due to the initial heating of the filament This is normal operation due to the initial heating of the filament. Section 9: Servicing and Maintenance Gauge tube servicing In many cases, a gauge tube may become fouled with oil or other foreign matter. It is often possible to restore the functionality of contaminated probes with cleaning. If the contaminant is known, the tube should be filled with a fluid that is known to be a solvent to that contaminant. As an example, ether is often effective in removing residues of some oils. Commercial carburetor cleaners are very powerful solvents and are highly effective against some contaminants. After cleaning with solvents, the gauge tube should be completely dried or flushed with a volatile solvent to assure that it is dry prior to reinstalling it. If this is not done, contamination of the system may result. Maintenance Your vacuum instrument should give you many years of trouble-free service. There are no regularly scheduled maintenance intervals. If consistent accuracy is required, it is recommended that the gauge, tube, cable and power supply be returned for a yearly calibration check. For more information, please contact the Kurt J. Lesker Company.

10 Notes on calibration The instrument is calibrated in nitrogen, which has thermal properties virtually identical to air. Other gasses will affect the readings by an amount proportional to the thermal conductivity of the gases. In most cases, the gases present in a vacuum system will be air, nitrogen, or oxygen, and no appreciable errors will occur. Certain other gases, however, have thermal conductivity significantly greater than air and will cause the instrument to read higher than the actual amount of pressure. Examples of such gases are water vapor, fluorocarbon refrigerants, and acetone. Conversely, other gasses have thermal conductivity significantly lower than air and will cause the instrument to read lower than actual pressure. Examples of such gases include helium, oxygen and to a lesser extent, CO2. When interpreting readings using gasses other than air, it should be borne in mind that the Vacuum Gauge reads absolute pressure that is the opposite of vacuum. Thus, a lower numerical reading actually is a higher level of vacuum. Section 10: Accuracy Instrument Repeatable Accuracy Range Accuracy 1~99 millitorr +/- 2 millitorr or 20% 100~1000 millitorr +/- 15% Section 11: Specifications Time to resolve 2 seconds to decade, 20 seconds to full accuracy

11 Input Voltage 5.0 Volts DC external power, 110/220VAC 50-60 Hz using supplied power adapter Maintenance Interval 1-10 years depending on use Overall Dimensions, front panel 2.75 in high, 3.6 in wide, 2.3 inches deep Ambient Operating range 32 F to 100 F Relay Contacts Type C (Normally Open, Common and Normally Closed) 24VDC, 1 Amp Measurement Media Clean Dry Air or Nitrogen Certifications: RoHS; CE Certified, third party with KJL-6000SS tube: EMC Emissions: CFR 47 FCC Part 15 Subpart B Class B emissions requirements (USA) EN 55011:2009:/A1:2010 Group 1 Class B ISM emissions requirements (EU) EN 61000-3-2:2006/A1:2009/A2:2009 limits for harmonic current emissions (equipment input current up to and including 16A per phase) EN 61000-3-3:2008: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current p to and including 16A EMC Emissions and Immunity: EN 61326-1:2013 EMC requirements for Electrical equipment for measurement, control and laboratory use General Use Face 2.87 high x 3.7 wide

12 Depth 0.42" Face Thickness 3.5" Face to Rear + cable bend 3.08 surface to rear + bend 3.1" Face to rear of boot 2.68" surface to rear 2.95" Face to rear + cable bend without boot 2.53" Sfc to rear + cable bend, no boot Spare Parts Sensor: KJL-6000SS Power Supply: PS-TCGAU-1 10 Sensor Cable: KJL615TC-RCH10 30 Sensor Cable: KJL615TC-RCH30 50 Sensor Cable: KJL615TC-RCH50 (requires calibration adjustment) Section 12: Understanding Torr This instrument and many similar instruments are calibrated in microns or "millitorr." It is appropriate to discuss what microns are and to relate microns to other measures of pressure and vacuum. Microns are not really a measure of vacuum at all, but rather of absolute pressure. The pressure of the atmosphere is 14.696 or approximately 14.7 pounds per square inch at sea level. One TORR is an absolute pressure of one millimeter of mercury. A millitorr is equal to one thousandth of a TORR. A MICRON is the same as a millitorr.

13 This pressure is due to the weight of all of the air in the earth's atmosphere above any particular square inch. This 14.696 PSI is equivalent to the pressure produced by a mercury column of approximately 29.92 inches high or.76 meters (~ 3/4 of a yard) or 760 millimeters of mercury. Atmospheric pressure varies greatly with altitude. It decreases approximately 1 inch of mercury per thousand feet of altitude. It also varies widely with local weather conditions. (Variations of one half inch in a single day are common.) The word vacuum means pressure lower than atmosphere or "suction." However, in describing negative pressure, the atmosphere is only a satisfactory reference if we are dealing with values of vacuum down to about 27 inches of mercury. Below that, it is much more useful to talk in terms of absolute pressure, starting from absolute zero. The Vacuum Gauge does just this.

14 Section 13: TERMS OF USE, LIMITED WARRANTY & LIABILITY WAIVER Kurt J. Lesker Company offers all of its products with the following terms and conditions and notices as follows. By accepting and/or using a Kurt J. Lesker Company product, you hereby acknowledge and agree to the following terms and conditions, and acceptance of these terms and conditions are a condition precedent to any purchase/sale agreement between you and Kurt J. Lesker Company. Exclusive Obligation: The Kurt J. Lesker Company product you are purchasing has been designed for a specific use within a set of suitable operating conditions, as set forth in its User Manual, or as indicated otherwise by Kurt J. Lesker Company. Any use of the Kurt J. Lesker Company Product for any purpose or under any conditions, other than those specified, shall render any limited warranty void, and shall expressly invalidate any liability of Kurt J. Lesker Company for damages as a result of such misuse. User limitation: You may not modify, copy, distribute, transmit, display, perform, reproduce, publish, license, create derivative works from, transfer, or sell, any information, software, products or services obtained from or created by Kurt J. Lesker Company to any third party, without the express written consent of Kurt J. Lesker Company to do otherwise. Any violation of this provision shall give rise to an indemnification of Kurt J. Lesker Company by you, for any third party claims arising out of such violation. 1 Year LIMITED Warranty: All Kurt J. Lesker Company products are warranted against any manufactured defect for a period of (365) days from date of purchase, unless such product is a custom-work for you and not a standard Kurt J. Lesker Company product. Any product qualifying as a custom-work shall not be warranted against any defects for any purpose, and your acceptance of such custom-work shall relieve Kurt J. Lesker Company of any liability for any purpose. WITH THE EXCEPTION OF THE LIMITED WARRRANTY ABOVE, YOU AGREE ANY Kurt J. Lesker Company PRODUCT IS PROVIDED AS IS, EXCLUSIVE OF ANY WARRANTY, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED. Limitation Of Liability: You agree and acknowledge, Kurt J. Lesker Company shall have no liability to you whatsoever for any direct, indirect, punitive, incidental, special consequential damages arising out of or connected with the use or misuse of its products. In particular, given the nature of Kurt J. Lesker Company products, you agree and acknowledge, under no circumstances whatsoever shall Kurt J. Lesker Company be liable to you for any consequential damages for damage to any non- Kurt J. Lesker Company product or service, arising from the failure, use or misuse of a Kurt J. Lesker Company product, including, but not limited to, any vacuum system, engine, vehicle, factory, or the like. In the event, a court of law with proper jurisdiction finds Kurt J. Lesker Company liable to you for any purpose, you agree and acknowledge Kurt J. Lesker Company s maximum liability shall not exceed the purchase price of one unit of product giving rise to such liability, or $250.00, whichever is greater. Entire Obligation: These terms and conditions express the entire obligation of Kurt J. Lesker Company with respect to its products. If any part of these terms and conditions are deemed void, invalid, unenforceable or illegal, including, but not limited to, the warranty disclaimers, liability disclaimers and liability limitations set forth above, then the unenforceable clause or sentence may be disregarded with the remainder of these terms and conditions valid and enforced. In the event the unenforceable clause or sentence leaves a void in these terms and conditions, a provision closely matching the intent of the unenforceable provision should be deemed inherent within these terms and conditions, slightly modified to render such provision valid and enforceable. General: These terms and conditions are governed by the laws of the State of Pennsylvania, USA. You hereby consent to the exclusive jurisdiction and venue of the Courts of Pennsylvania, in all disputes arising out of or relating to the use of this product. Use of this product is unauthorized in any jurisdiction that does not give effect to all provisions of these terms and conditions. Modification of Terms and Conditions: Kurt J. Lesker Company reserves the right to change the terms, conditions, and notices under which their products are offered.