4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS

Similar documents
4SCU13 PRODUCT SPECIFICATIONS

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14 SERIES

MAINLINE MLA14 AIR CONDITIONERS

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

VARIABLE SPEED AIR CONDITIONERS

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

Evaporator (DX) Freon Applications 1 12 Tons MHF

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

FMU4X, FMC4X FMU4P, FMC4P

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

MAINLINE MLP14**A HEAT PUMPS

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

This parts list is current as of the above revision date. See for the current revision.

Rheem Classic Series Heat Pump

Ruud Achiever Series Heat Pump

Uniflair LE TDAR-TUAR

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

Ruud Achiever Series Heat Pump

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

RPLA. Heat Pumps. Parts List 19-July-2011

This parts list is current as of the above revision date. See for the current revision.

Rheem Classic Series Two Stage Heat Pump

AE R1 February 2015

This parts list is current as of the above revision date. See for the current revision.

RPKA. Heat Pumps. Parts List 07-May-2014

RPNK. Heat Pumps. Parts List 25-July-2011

NLE10CN V/50Hz 1~

DLE5.7CN V/60Hz 1~

Ducted Reverse Cycle Air Conditioning of Distinction

LENNOX SLP98UHV DIAGNOSTIC CODES

DLE6.5CN V/60Hz 1~

Part 1 General Information Part 2 Outdoor Units... 8

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

DLE7.5CN V/50Hz 1~

NLE11CNL V/60Hz 1~

FA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest

TECHNICAL SPECIFICATIONS

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Product Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

This parts list is current as of the above revision date. See for the current revision.

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

The CWE / HWE-R Series: Overview. Frame and cabinet covering

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

/ /

Aquavar SOLO 2 Frequently Asked Questions

TECHNICAL DESCRIPTION

MODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A

Commercial Standard and High-Efficiency Condensing Units

KCS-Line. Air Cooled Condensers NEW CONTENTS PRODUCT DATA & INSTALLATION. Refrigerant: R404A, R507, R22

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Product Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Refrigeration and Air Conditioning Technical leaflet

Installation Instructions

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

System Pressure Manager Standard & System Pressure Manager Plus

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

200 PSI COMPRESSORS - MODEL NUMBERS

Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors

Limburghaven PL Nieuwegein The Netherlands. compressors. (t) +31 (0) (f) +31 (0) (e)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

AIR COOLED SCREW WATER CHILLERS

KKT Training Series: ECO Series, Preventative Maintenance

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Refrigeration Scroll For Parallel Applications

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

Quick Start SunPump Install

Installation Instructions

TM420SDL - Air Compressor 100 Litre Tank / 3hp 14.6cfm / 416lpm Displacement

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

BUBBLER CONTROL SYSTEM

Recirculating Coolers

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Hazardous Duty Division 1 Explosion Proof Class I Only, Groups C (as noted), D

Marschalk Model # 94000

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Transcription:

PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy service High and low pressure switches factory installed Trade available components Factory installed crank case heater Charged for 15 ft. of line set Thermostat flexibility: works with the Comfort Sync T-Stat (when matched with communicating indoor unit) or a conventional 24V T-Stat Self diagnostics saves last 10 fault codes regardless of power interruption WARRANTY 10 year limited warranty on compressor, 10 year limited warranty on all parts, extended warranty available* COMMUNICATING THERMOSTAT ENABLED COMPRESSOR High-efficiency 2 stage Copeland UltraTechTM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected against high temperature motor overload conditions Heavy-duty compressor sound blanket for quiet operation *Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. Lifetime limited heat exchanger warranty applies to registered equipment only (Standard 20 years with no online registration). See full warranty at www.alliedair. com for terms, conditions and exclusions. CABINET Full metal louvered panels remove with just two screws per panel for easy coil cleaning and service Controls located in corner post for easy installation and service Rounded corners for safety and attractive, clean appearance Baked polyester paint finish over galvanized steel for maximum durability PVC-coated wire fan discharge grille External gauge ports for easy service COILS Enhanced aluminum fins and copper tubing for higher efficency and capacity Raised coil prevents debris from collecting in bottom of coil and causing loss of airflow Page 1

MODEL NUMBER GUIDE 4 SCU 16 LS 1 24 P - 1 A REFRIGERANT - 4 = R410A SCU SPLIT CONDENSING UNIT 16 16 S NOMINAL (HIGHEST ACHIEVABLE) LS LOUVERED TWO-STAGE COMMUNICATING ENABLED MINOR REVISION CODE MAJOR REVISION CODE VOLTAGE P - 208-230V/60HZ/1PH NOMINAL CAPACITY 24-24,000 SERIES PHYSICAL AND ELECTRICAL Model Voltage/Hz/ Phase Voltage Range Min. Circuit Amp. Max. Over current (amps) Compressor Load (amps) Locked Rotor (amps) Load (amps) Fan Motor HP Nom. RPM Refrig. Charge (oz.) Weight (lbs.) 124P-1 230/60/1 197-253 13.9 20 11.4 52.0 1.1 1/5 1075 117 200 136P-1 230/60/1 197-253 21.9 35 19.0 82.0 1.1 1/6 825 137 230 148P-1 230/60/1 197-253 28.1 45 24.0 96.0 1.1 1/6 825 180 262 160p-1 230/60/1 197-253 33.8 55 26.0 118.0 1.7 1/4 825 214 310 For applications below 230V, use of a Hard Start Kit is recommended. SOUND RATINGS Model No. Sound Rating dba 124P-1 74 136P-1 74 148P-1 76 160P-1 76 DIMENSIONS (IN.) Model No. A B C 124P-1 24-3/4 26-3/4 29-3/4 136P-1 29-3/8 31-1/4 29-3/4 148P-1 29-3/8 31-1/4 37-3/4 160P-1 29-3/8 31-1/4 43-3/4 Page 2

COOLING PERFORMANCE WITH EVAPORATOR COILS Model Expansion Model Evaporator Coil or S 1 Piston2 124P-1* E(U,C,M,H)1P36A,B,C 14.00 11.50 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36A,B,C 13.50 11.00 34,400 25,800 1200 3/4 3/8 3/4 3/8 7/8 3/8 NA A401 136P-1* E(U,C,M,H)1P43B,C 13.50 10.50 34,400 26,300 1200 3/4 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C)1P62C 13.50 10.50 46,000 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 148P-1* E(U,C)1P62D 13.00 10.50 46,000 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 EH1P62C,D 14.00 11.00 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 160P-1* E(U,C)1P62C 13.50 11.00 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 * All matches must be with variable speed air systems - The furnace must be able to provide first and second stage air flows, (or only run at high speed) 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 3

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 24 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 BCS2M24@00NA1P 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 BCS2M36@00NA1P 15.5 12.5 24,000 18,000 800 3/4 3/8 7/8 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B EFV08BC 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B EFV08BC 15.5 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29A A80DF1E045A12 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36A A80DF1E045A12 15.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A80DF1E070B12 14.5 11.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A80DF1E070B12 14.5 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29A A80+2V070A12 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36A A80+2V070A12 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A80+2V090B16 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B A80+2V090B16 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 124P-1 E(U,C,M,H)1P29A A80UH1E045A12* 15.5 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36A A80UH1E045A12* 15.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A80UH1E070B12* 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A80UH1E070B12* 14.5 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29A A80#2V070A12 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36A A80#2V070A12 15.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A80#2V090B12 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B A80#2V090B12 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A80#2V090B16 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B A80#2V090B16 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A95DF1E045B12S 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95DF1E045B12S 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A95DF2V045B12S 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95DF2V045B12S 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A95UH1E045B12S 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95UH1E045B12S 15.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 4

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 24, 36 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 E(U,C,M,H)1P29B A95UH1E070B12S 14.5 11.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95UH1E070B12S 14.5 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A95UH2V045B12S 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95UH2V045B12S 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P29B A95UH2V070B12S 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A95UH2V070B12S 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 124P-1 A95UH2V090C12S 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A96DFMV070B12 A97DSMV070B12 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B A96DFMV070B12 A97DSMV070B12 16.0 12.0 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B A96UHMV070B12 A97USMV070B12 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,M,H)1P29B A96UHMV070B12 A97USMV070B12 A96UHMV090C12 A97USMV090C12 16.0 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B LBR,LUF*****V14 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B LHF,LHR,LUF*****V12 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 E(U,C,M,H)1P36B LUF,LBF,LBR*****V14 15.5 12.5 24,000 18,000 800 3/4 3/8 3/4 3/8 3/4 3/8 NA A401 BCS2M36@00NA1P 16.0 12.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B EFV12BC 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B EFV12BC 16.0 11.5 34,400 26,200 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36A A80DF1E045A12 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 136P-1 E(U,C,M,H)1P36B A80DF1E070B12 16.0 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80DF1E070B12 15.0 11.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A80DF1E090B16 15.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80DF1E090B16 15.0 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A80+2V090B16 15.5 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80+2V090B16 A80+2V110C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A80+2V110C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36A A80UH1E045A12* 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 5

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 36 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 E(U,C,M,H)1P36B A80UH1E070B12* 15.0 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80UH1E070B12* 15.5 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A80UH1E090B16* 15.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80UH1E090B16* 15.0 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36A A80#2V070A12 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A80#2V090B12 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80#2V090B12 15.5 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A80#2V090B16 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A80#2V090B16 A80#2V090C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A80#2V090C20 15.5 11.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A80#2V110C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 136P-1 E(U,C,M,H)1P36B A95DF1E070B16S 15.5 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95DF1E070B16S A95DF1E090C16S 15.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95DF1E090C16S 15.5 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B A95DF2V045B12S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95DF2V045B12S E(U,C,M,H)1P36B A95DF2V070B16S 15.0 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95DF2V070B16S A95DF2V090C20S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95DF2V090C20S A95DF2V110C20S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95DF2V110C20S E(U,C,M,H)1P36B A95UH1E070B12S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95UH1E070B12S 15.5 11.0 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 A95UH1E090C16S 15.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95UH1E090C16S 15.5 11.5 34,400 25,800 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 6

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 36 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 E(U,C,M,H)1P36B A95UH2V045B12S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95UH2V045B12S E(U,C,M,H)1P36B A95UH2V070B12S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A95UH2V070B12S A95UH2V090C12S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95UH2V090C12S A95UH2V090C16S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95UH2V090C16S A95UH2V090C20S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95UH2V090C20S A95UH2V110C16S 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A95UH2V110C16S 136P-1 E(U,C,M,H)1P36B E(U,C,M,H)1P43B E(U,C,M,H)1P43C A96DFMV070B12 A97DSMV070B12 A96DFMV070B12 A97DSMV070B12 A96DFMV090C16 A97DSMV090C16 A96DFMV090C16 A97DSMV090C16 15.5 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 A96DFMV090C20 A97DSMV090C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A96DFMV090C20 A97DSMV090C20 A96DFMV110C20 A97DSMV110C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A96DFMV110C20 A97DSMV110C20 E(U,C,M,H)1P36B A96UHMV070B12 A97USMV070B12 16.0 11.5 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B A96UHMV070B12 A97USMV070B12 A96UHMV090C12 A97USMV090C12 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A96UHMV090C12 A97USMV090C12 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 7

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 36, 48 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 E(U,C,M,H)1P43C A96UHMV090C16 A97USMV090C16 A96UHMV090C16 A97USMV090C16 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 136P-1 A96UHMV110C20 A97USMV110C20 16.0 12.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43C A96UHMV110C20 A97USMV110C20 E(U,C,M,H)1P36B LBR,LUF*****V14 15.0 11.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B LBR,LUF*****V14 15.0 11.5 34,400 26,200 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B LHF,LHR,LUF*****V12 15.0 11.0 34,400 25,800 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B LHF,LHR,LUF*****V12 15.0 11.5 34,400 26,200 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P36B LUF,LBF,LBR*****V14 15.0 11.5 35,000 26,200 1200 7/8 3/8 3/4 3/8 7/8 3/8 NA A401 E(U,C,M,H)1P43B LUF,LBF,LBR*****V14 15.0 11.0 34,400 26,200 1200 7/8 3/8 7/8 3/8 7/8 3/8 NA A401 BCS2M48@00NA1P 15.0 12.0 46,000 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 EFV16CC 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 E(U,C)1P62D EFV20DC 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A80DF1E110C20 14.5 11.5 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A80+2V110C20 15.5 11.5 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 148P-1 A80UH1E090C20* 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A80UH1E110C20* 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A80#2V090C20 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A80#2V110C20 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 E(U,C)1P62D A80#2V135D20 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A95DF2V090C20S 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A95DF2V110C20S 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A95UH1E110C20S 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 A95UH2V090C16S 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 8

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES 48, 60 Model Evaporator Coil or Model Variable Speed Furnace S 1 Expansion Piston 2 A96DFMV110C20 A97DSMV110C20 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 148P-1 E(U,C)1P62D A96UHMV090C16 A97USMV090C16 A96UHMV090C20 A97USMV090C20 A96UHMV110C20 A97USMV110C20 A96UHMV135D20 A97USMV135D20 15.0 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 15.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 15.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 15.0 11.0 46,000 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 E(U,C)1P62C LUF*****V20 14.5 11.0 46,500 34,900 1600 7/8 3/8 7/8 3/8 7/8 3/8 NA A402 BCS2M60@00NA1P 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 E(U,C)1P60D EFV20DC 14.6 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 E(U,C)1P62D EFV20DC 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80DF1E110C20 15.0 11.5 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80+2V110C20 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80UH1E090C20* 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80UH1E110C20* 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80#2V090C20 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A80#2V110C20 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 160P-1 E(U,C)1P62D A80#2V135D20 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95DF1E110C20S 14.5 10.5 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95DF2V090C20S 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95DF2V110C20S 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95UH1E110C20S 14.5 10.5 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95UH2V090C20S 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 A95UH2V110C20S 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 E(U,C,H)1P62D A95UH2V135D20S 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 E(U,C)1P62D A96DFMV090C20 A97DSMV090C20 A96DFMV110C20 A97DSMV110C20 A96UHMV090C20 A97USMV090C20 A96UHMV110C20 A97USMV110C20 A96UHMV135D20 A97USMV135D20 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 14.5 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 15.0 11.0 57,000 42,800 1800 7/8 3/8 7/8 3/8 1 1/8 3/8 NA A402 + DF or DS # UH or US @ V or S 2 Required to achieve rating. If NA (Not Applicable) is in the piston column, then is required Page 9

COOLING PERFORMANCE EXTENDED RATINGS Model Model Temp DB/WB ºF Temp - DBºF 65 82 95 105 115 Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 124P-1 E(U,C,M,H)1P36B/EFV08B 85/72 27,000.67 1.43 26,500.68 1.70 25,000.72 1.93 23,600.73 2.38 22,200.76 2.59 80/67 26,000.70 1.40 25,500.71 1.67 24,000.75 1.90 22,600.76 2.35 21,200.79 2.56 75/63 25,000.73 1.37 24,500.74 1.64 23,000.78 1.87 21,600.79 2.32 20,200.82 2.53 136P-1 E(U,C,M,H)1P43B/EFV12B 85/72 40,200.66 1.76 38,200.68 2.31 36,400.69 2.98 35,000.71 3.28 33,000.74 3.69 80/67 39,200.69 1.73 37,200.71 2.28 35,400.72 2.95 34,000.74 3.25 32,000.77 3.66 75/63 38,200.72 1.70 36,200.74 2.25 34,400.75 2.92 33,000.77 3.22 31,000.80 3.63 148P-1 E(U,C)1P62C/EFV16C 85/72 55,400.68 2.93 52,000.71 3.43 49,500.72 3.89 48,000.73 4.23 45,800.75 5.53 80/67 53,400.71 2.90 50,000.74 3.40 47,500.75 3.86 46,000.76 4.20 43,800.78 5.50 75/63 51,400.74 2.87 48,000.77 3.37 45,500.78 3.83 44,000.79 4.17 41,800.81 5.47 160P-1 E(U,C)1P62D/EFV20D 85/72 61,000.64 3.82 60,000.65 4.49 59,000.68 5.11 55,000.69 5.66 52,000.72 6.30 80/67 59,000.67 3.79 58,000.68 4.46 57,000.71 5.08 53,000.72 5.63 50,000.75 6.27 75/63 57,000.70 3.76 56,000.71 4.43 55,000.74 5.05 51,000.75 5.60 48,000.78 6.24 * All ratings are with required indoor variable speed matches. Extended data shown is actual for models listed and typical for all matches. Page 10

ACCESSORIES KIT NUMBER DESCRIPTION USED WITH 45F08 Compressor Low Ambient Cut-off All s 93G35 Freezestats (3/8") All s 39H29 Freezestats (1/2") All s 50A93 Freezestats (5/8") All s 47J27 Time Off Control All s 67K90 Crank Case Heater All s 63W22 124 Hard Start Kit 2-3 ton 63W23 136 10J42 148 Hard Start Kit 4-5 ton 63W24 160 34M72 Low Ambient All s 85W66 Relay Kit- Constant Torque All Constant Torque Furnaces Page 11

1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring obligations. FORM NO. -100 (06/2014) 2014 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page 12