D e s c r i p t i o n

Similar documents
MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

Spin-On Filters SSF 24,25

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Change-Over Pressure Filter DFDK

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Flow rates to 200 l/min

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

PLD 03 T A CASAPPA S.p.A.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure reducing valve, pilot operated, Model 3DR

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Tank-Mounted Suction Filter

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Proportional Throttle Cartridges, Size 16

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

VALVES ISO 5599/1, SERIES IPV-ISV

FILTRATION TECHNOLOGY STAUFF. Spin On Filters. Quality and Service Worldwide

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

3-Way Safety Block DSV

Inverse Proportional Pressure-Relief Cartridge, Size 10

3-Way Pressure-Reducing Cartridge, Size 2 4

Schroeder Check Test Point System

PRESSURE COMPENSATORS TECNORD

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

SOLENOID VALVES AND PNEUMATIC VALVES

[Instruments for vacuum measurement, checking and adjustment] 3

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Quality filter cartridges and customized housings.

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

SUCTION FILTERS. BYPASS VALVE Setting: 30 kpa (0,30 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

Pneumatic valve islands

Diaphragm pressure switches, 42 V

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

Pressure-Relief Cartridge Valve, Size 4

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Pneumatic spool valve islands

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Bladder Accumulators High pressure

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Intrinsically safe solenoid valves on/off controls - ATEX certification

OFFICINE OROBICHE S.p.A. 1/9

Series BLK Oil - air cooler

Electrically Operated Pressure-Relief Cartridge, Size 10

Safety and Shut-off Block SAF/DSV

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Diaphragm Accumulators

D62 - D63 Directional Control Valve l/min

Cover headline. Cover subheadline. Check Valves

ALF400 to 900, ALT-5/-9

4/2 way Pneumatic Solenoid Valve

directional control valve series cv691

PVQ 13 A2 R SE 1 S 20 C-11 D

hyprofiltration.com/fsw

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

SDM to 8 sections monoblock valve D1WWDA02A

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Diaphragm Accumulators

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Level transmitter LT 100

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Safety and Shut-off Block SAF/DSV

Solenoid valves VZWF, force pilot operated

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Pilot valves for pilot operated servo valves

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Monoblock Directional Control Valve RMB 202

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Compressed Air Cleaning Filter Series

BS ml Bottle Sampling Unit

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Transcription:

MPS Series

D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and easy to service and provide a clean solution when changing elements. The filter elements are either resin-impregnated paper (ßx>), glass fibre (ßx³ ) or square wire mesh. The unique filter head is designed for both European CS and American CG standard canister series. One head design series accomodates both styles of elements. Also available is a new design utilizing a pressure differential visual and electrical indicators - ideal for lubrication applications. MPS filters are specifically designed for contamination control in hydraulic and lubrication circuits for mobile applications, agricultural and machine tool systems. The CW series of canister removes water from oil while filtering the oil at the same time. Water absorbent polymers up to 8 times their own weight, provide this major feature. Water holding capacities: - CW - 4 ml. CW 1-788 ml. DIFFERENTIAL INDICATORS For Use with series 1 filter heads. New absolute filter elements independently tested in the following Institutes: For Use with series filter head. SUCTION INDICATORS ELECTRICAL VISUAL RETURN LINE INDICATORS VISUAL UNI EN ISO 91 N 37/98 ELECTRICAL MPS /3./UK

F i l t r a t i o n t e c h n o l og y element: Materials End caps: Galvanized steel Support tube: Galvanized steel Support frames: Galvanized steel with an epoxy coating A Series Inorganic microfibre Pre-filtration and External support media External wire mesh Inner support tube Internal wire mesh Microfibre filtration media Internal support media MP elements - Conform to the following ISO standards ISO 941 - Verification of collapse/burst resistance. ISO 94 - Verification of fabrication integrity and determination of the first bubble point. ISO 943 - Verification of material compatibility with fluids. ISO 373 - Method for end load test. ISO 374 - Verification of flow fatigue characteristics. ISO 3968 - Evaluation of pressure drop versus flow characteristics. ISO 16889 - Multi-pass method for evaluating filtration performance. Element material Absolute filtration A Series Inorganic microfibre with acrilic support Contamination retention as per ISO 16889: Multi-pass test. New improved ß ³ filter elements with greater efficiency and increased dirt holding capacity elements A3 A6 A1 Dimensions for ß (µm) values ß ³ ß ³ ß ³ 7 ß ³ (%) (9%) (98,7%) (99,%),4 3 3 4,6 6 3 6 7,8 1 13 19 N.B. Other materials giving different degrees of filtration are available on request. ß 8 1, Filtration ratios ß 1 ß > 1. > 1. >. > 1. ³ > 1. > 1, > 3 D P (bar) 7 7 7 7 ing area elements CS-CG-CT A3/A6 A1/ 7 1 19 316 39 19 316 39 1 39 39 Values in cm Element material Nominal filtration P Series Resin - impregnated paper M Series Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size) ing area elements CS-CG-CT P1/P M 7 1 1 44 414 43 76 1 17 199 4 CWSeries Resin - impregnated paper M6 M9 1 17 199 4 1 17 199 4 Values in cm CW 1 P1/P 3

S p e c i f i c a t i o n Materials Head Aluminium Bypass valve Nylon Working temperature Pressure filter body Collapse pressure filter elements Seals A Series: Nitrile (Buna-N) V Series: Viton Maximum working pressure up to Indicator Brass From - to +11 C For temperatures outside this range, please consult our Sales Network Organization 1 bar 4 bar Bypass valve Calibration pressure s of indicators for MPS series (MPS -7-1 ) and MST series Visual indicator Electrical indicator Bypass valve, differential opening pressure: S series:,3 bar ± 1% (MPS series only) R series: 1,7 bar ± 1% Description: MPS series filters are fitted with indicators 1 Kpa =.1 bar switching: Suction filters at a pressure of: kpa ± 1% Line filters at a pressure of: 1,3 bar ± 1% (MPS series only) Return filter at a pressure of: 1,3 bar ± 1% (MPS-MST series only) Suction filter: (MPS series only) VS vacuum switch Return and line filter VA Pressure gauge VR colour coded pressure gauge Suction filter (MPS series only) E Vacuum switch with change over contact Return filter ER Pressure switch with N.O. contacts EC Pressure switch with N.C. contacts s of indicators for MPS series 1 (MPS 1-71-11-11-31-31) MPS filter series 1 (1-71-11 and so on) are fitted with, differential style indicators. Visual indicator Electrical indicator Visual-electrical indicator scale - 76 cm Hg scale - 1 bar scale - 6 bar Operational information: 1V - Z1 Series for with bypass set switching at 1, bar ± 1% to 1,7 bar V6 - Z6 Series for without bypass switching at bar ± 1% N1 Series for with bypass set switching at 1, bar ± 1% to 1,7 bar N6 Series for without bypass switching at bar ± 1% 1E - K1* Series for with bypass set switching at 1, bar ± 1% to 1,7 bar E6 - K6* Series for without bypass switching at bar ± 1% *For K visual-electrical indicator, specify the voltage (il. K61 = LED: 4 volt) Switching at kpa ± 1% Max voltage: V 6 Hz Max current: A resistive, A inductive Protection degree IP6 Switching at 1,3 bar ± 1% Max voltage: 48V 6 Hz Max current:,a resistive,a inductive * 1-4 Volt { - 11 Volt 3-3 Volt

S p e c i f i c a t i o n Pressure differential indicator option K - E - N Series Supply voltage (/6 Hz) (V) Vca 1 Vca Vcc 3 Vcc 1 Vcc Resistive load (A),, Inductive load (A) 3,3,3 CONNECTOR DIN 436 ELECTRICAL CONNECTION E - N SERIES N.C. N.O. ELECTRICAL CONNECTION K SERIES N.C. N.O. Visual V series Visual Z series Ø16 G1/ Ø16 G1/ Electrical N series Visual led - Electrical K series Led Visual - Electrical E series, Ø16 G1/ Ø16 G1/ Ø16 G1/

S p e c i f i c a t i o n Fluid Compatibility head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water-based emulsions (types HFAE-HFAS as per ISO 6743/4) synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) water-glycol (types HFC as per ISO 6743/4) Seals A Series Nitrile (Buna-N) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water-based emulsions (types HFAE-HFAS as per ISO 6743/4) water - glycol (types HFC as per ISO 6743/4) V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) elements As per ISO 943; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) and synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) For water-based emulsions (types HFAE-HFAS as per ISO 6743/4) and fluids other than those mentioned, please consult our Sales Network Organization. International standards for contamination fluid control A general (no direct) comparison between ISO 446 and NAS 16 is given in table below. Contamination Correspondent Recommended Typical applications codes codes filtration ISO 446 NAS 16 degree 4µm(c) 6µm(c) 14µm(c) B x ³ 14 1 9 3 3 High precision and laboratory servo-systems 17 1 1 6 3-6 Robotic and servo-systems 18 16 13 7 1-1 Very sensitive - high reliability systems 18 1 9 1-1 Sensitive - reliable systems 1 19 16 1 1- General equipment of limited reliability 3 1 18 1-4 Low - pressure equipment not in continuous service

S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n elements types Pl eas e r e fe r t o A Series P Series M Series Absolute inorganic microfibre Nominal cellulose impregnated Metal mesh media, available in filtration media, available in paper media, available in 1, 6, and 9 micron. 3, 6, 1 and micron and micron. Example - M, M6 or M9. Example - A3, A6, A1 or Example - P1 or P in div i d ual pr e ss ur e dr o p cu r ve s t o ob t ai n f ilt er a ss emb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. Indicator port for return line filter IN MPS -7 Series C - No. Threaded holes Ø 96 OUT Indicator port for suction line filter Lengths MPS 1-71 Series Indicator for suction filter MPS -7 (only for option G1-G) ø 4 B 14 3 9 VS 9 9 EO 4 1/8 BSP Revolving PG 11 ø Cable 8/1 H H1-1 18 7-71 48 68 Indicator port Indicator for return filter MPS -7 (only for option G1-G) VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7 MPS -71 Thread connections MPS SERIES -1 SIZES A3 A6 A1 P1 M6-M9 Flow rates with 3 mm /s fluid viscosity including filter element A B C G1 3/4 BSP 1/8 BSP M6 G 3/4 NPT 1/8 NPT 1/4 UNC G3 SAE 1-1 1/16-1 UN 1/8 NPT 1/4 UNC G4 SAE 8-3/4-16 UNF 1/8 NPT 1/4 UNC G 1 BSP 1/8 BSP M6 G6 1 NPT 1/8 NPT 1/4 UNC 1 7, MPS SERIES 7-71 SIZES A3 A6 A1 P1 M6-M9 4 44 48 8 4 49 3 63 8 9 11 14 18 16 4 11 13 1 18 6 SEE TABLE BELOW SEE TABLE BELOW 1, 1,3 Suction filter - Housing pressure drop ø 4, Indicator for line filter MPS 1-71 Led.,4 1 1 3 Return line filter - Housing pressure drop,3, Z V N K E,1 1 3 4 6 7 9

S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n Pl eas e r e fe r t o in div id ual pr e ss ur e dr o p cu r ve s t o o b t ai n f ilt er a ss e mb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. Indicator por t for return line filter C - No. Threaded holes MPS SERIES 1-11 SIZES IN OUT Indicator por t for suction line filter Lengths MPS 1-11 H H1 1-11 41 66 1-11 86 311 A3 A6 A1 P1 M6-M9 7 8 11 14 13 16 19 4 3 6 1 1/4 MPS SERIES 1-11 SIZES, Ø 19 MPS 1-1 Series 16 3 B MPS 11-11 Series 8 Indicator port A3 A6 A1 8 18 1 11 3 16 4 1 1/4,3 P1 M6-M9 1 4 68 9 1/8 BSP Indicator for return filter MPS 1-1 (only for option G1) ø 4 133 Indicator for suction filter MPS 1-1 (only for option G1) ø 4 VS VR - VA A/F.14 Indicator for line filter MPS 11-11 EO ER - EC 6 43 A/F.4 133 Thread connections Led Revolving PG 11 ø Cable 8/1 Pg 7. Flow rates with 3 mm /s fluid viscosity including filter element A B C G1 1 1/4 BSP 1/8 BSP M8 G 1 1/4 NPT 1/8 NPT /16 UNC G3 SAE - 1 /8-1 UN 1/8 NPT /16 UNC Suction filter - Housing pressure drop 1 7,, 1 3 4 6 7 9 Return line filter - Housing pressure drop,4,3,,1 3 7 1 14 17 1 Z V N K E

& S e l e c t i o n i n s t a l l a t i o n i n f o r m a t i o n Pl e as e r e fe r t o in div i d ual pr e ss ur e dr o p cu r ve s t o o b t ai n f ilt e r a ss emb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. MPS SERIES SIZES MPS - A3 13 3 A6 17 4 A1 6 1 1/ 4, 9 11 46 7 7 P1 M6-M9 7 1 1 IN OUT MPS SERIES SIZES indicator (return) indicator (suction) A3 A6 Line Flow rate l/min * 18 1 Suction Flow rate l/min * 6 A1 31 8 1 1 1/ 4, P1 M6-M9 8 118 13 Flow rates with 3 mm /s fluid viscosity including filter element Ø 19 Lengths H 16 61 H1 41 86 14 Thread connections G1 G G3 1 A 1 1/ BSP 1/8 BSP 1 1/ NPT 1/8 NPT SAE 4-1 7/8-1 UN B 1/8 NPT Suction filter - Housing pressure drop C M1 3/8 UNC 3/8 UNC Indicator for suction filter (only for option G1) VS 9 EO Revolving 7,, ø 4 PG 11 ø Cable 8/1 1/8 BSP 7 1 1 1 Return line filter - Housing pressure drop,4,3 Indicator for return filter (only for option G1) ø 4 VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7,,1 6 1 18 4 3 36

S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n Please r e fe r t o in di v id ua l pr e ss ur e d r o p c ur ves t o o bt ai n f i l t e r a ss e m bl y p re ss ur e d r o p i n f or ma t io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. indicator (suction) indicator (return line) D indicator (suction) Indicator port for MPS 31-31 indicator (return line) indicator (return line) Lengths 3-31 3-31 Indicator for suction filter MPS 3-3 (only for option G1-G-F1) ø 4 VS Ø 19 83 1 A OUT IN A 186 F - No. 4 Threaded holes 9 EO Revolving PG 11 ø Cable 8/1 MPS 3-31 H H1 6 9 31 33 Thread connections Flange MPS SERIES 3-31 SIZES A3 A6 A1 P1 M6-M9 Flow rates with 3 mm /s fluid viscosity A B C D E F connections F1 1 1/ SAE 3 PSI/M 1/8 BSP M1 69,8 3,71 M1 F 1 1/ SAE 3 PSI/UNC 1/8 NPT 1/ UNC 69,8 1 MPS SERIES 3-31 SIZES A3 A6 A1 P1 M6-M9 13 17 9 7 Line Flow rate l/min * 18 1 31 8 3 4 6 11 1 1 Suction Flow rate l/min * 6 8 1 118 13 including filter element 1 1/ 1 1/ A B G1 1 1/ BSP 1/8 BSP G 1 1/ NPT 1/8 NPT G3 SAE 4-1 7/8-1 UN 1/8 NPT,4,6 Suction filter - Housing pressure drop C M1 3/8 UNC 3/8 UNC 3,71 1/ UNC 1/8 BSP Indicator for return filter MPS 3-3 (only for option G1-G-F1) VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7 7,, 7 1 1 1 ø 4 Indicator for line filter MPS 31-31 Led.,4,3, Return line filter - Housing pressure drop,1 6 1 18 4 3 36 Z V N K E Datasheet Reference: HM-19