Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Similar documents
Instruction Manual EMA 84 Digital Pressure Gauge

Instruction Manual BA90 Precision Barometer

Installation and Operation Manual

OPTIBAR P 1010 C Technical Datasheet

High-performance submersible pressure transmitter For level measurement Model LH-10

AMS 6916 Board mount pressure sensor with ratiometric analog output

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Instruction Manual Differential Pressure Transmitter

INSTALLATION & MAINTENANCE INSTRUCTIONS

Dual Solenoid Gas Valve Installation

Pressure Transmitters 36 F-27839

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

High-performance submersible pressure transmitter For level measurement Model LH-10

I/P Transducer Positioner Module

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

ASDX Series Silicon Pressure Sensors

Operating instructions Pitot Static Tube

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Sensoric 4-20 ma Transmitter Board Operation Manual

BGA158 Series CE Approved Class A Shutoff Gas Valve

Instruction Manual Contact Pressure Vacuum Gauge

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

SITRANS P measuring instruments for pressure

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Transmitter CS 21 Operation Manual

BGA158 Series CE Approved Class B Shutoff Gas Valve

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Peak Pressure Indicator MSI-3

P900. P900, Datenblatt Seite 1 DESCRIPTION

High-performance submersible pressure transmitter For level measurement Model LH-20

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Instruction Manual Differential Pressure Transmitter

Operating Instructions Melt Pressure Sensor

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

AMS 2710 PCB pressure sensor module with V output

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

MANUAL KPS Pressure Control Valve

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Magnetic level switch type MR783 Instruction Manual

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Climatic Independent Level Sensor LAR

Precision pressure sensor Basic version Model CPT6020

C-Flow Coriolis Mass Flow Meters

SPD310/SPD360 Air Differential

SX150A. Features. Typical Applications. Description

Pressure Switch for gas and air

Transmitter CS 21 Operation Manual

Installation and Operation Manual

Electronic relative and differential pressure switch type 616

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Pressure Switch for gas and air GGAO-A4

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

GEMS SENSORS & CONTROLS

Pressure Transmitter P41

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Operating Manual. PT303 Strain Gage Pressure Transmitter

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

DTG - LCD Digital Temperature Gauge USER MANUAL

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Differential Pressure Transmiter

STAGE, STADIUM & X-TREME SHOT.

Model PDT Dewpoint Transmitter

GasSense NDIR User Manual

GM-7000 Series CE Approved Gas Control Valve

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DPC-30 DPC-100. Reference Manual

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Electropneumatic Transducer (I/P) Installation, Operation and

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Proportional pressure regulators VPPE

In Vivo Scientific, LLC INSTRUCTION MANUAL

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Transcription:

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com Internet: www.halstrup-walcher.com Document 7100.003864 01/2018

Table of Contents 1 Safety precautions... 4 1.1 Appropriate use... 4 1.2 Shipping, assembly, electrical connections and start-up... 4 1.3 Troubleshooting, maintenance, repairs, disposal... 4 1.4 Symbols... 5 2 Instrument description... 6 3 Start-up... 6 3.1 Features... 6 3.2 Electrical instrument connections:... 6 4 Technical data... 7 5 Certificate of conformity... 9 2

Purpose of instruction manual This instruction manual describes the features of the AD 1000 absolute pressure sensor / BA 1000 barometer and provides guidelines for its use. Improper use of these instruments or failure to follow these instructions may cause injury or equipment damage. Every person who uses this device must therefore read the manual and understand the possible risks. The instruction manual, and in particular the safety precautions contained therein, must be followed carefully. Contact the manufacturer if you do not understand any part of this instruction manual. Handle this manual with care: It must be readily available throughout the lifecycle of the instrument. It must be provided to any individuals who assume responsibility for operating the instrument at a later date. It must include any supplementary materials provided by the manufacturer. The manufacturer reserves the right to continue developing this instrument model without documenting such development in each individual case. The manufacturer will be happy to determine whether this manual is up-to-date. Conformity This instrument corresponds to the state of the art and meets all legal requirements set forth in EC directives as evidenced by the CE label. 2018 The manufacturer owns the copyright to this instruction manual. This manual contains data, instructions and drawings pertaining to the features and usage of this instrument; copying this manual in part or in full or distributing it to third parties is prohibited. 3

1 Safety precautions 1.1 Appropriate use The AD 1000 absolute pressure transducer / BA 1000 barometer is designed for displaying atmospheric pressure and absolute pressure in such areas as weather stations and airports. Always observe the operating requirements particularly the permissible supply voltage indicated on the rating plate and in the Technical data section of this manual. The instrument may only be handled as indicated in this manual. Modifications to the instrument are prohibited. The manufacturer is not liable for damages caused by improper use or failure to follow these instructions. Violations of this type render all warranty claims null and void. 1.2 Shipping, assembly, electrical connections and start-up Do not close the pressure input ports when shipping, as changes in barometric pressure could damage instruments with low measuring ranges. Only technical personnel who are appropriately trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections. The instrument may only be operated by appropriately trained individuals who have been authorized by the operator of the facility. Pressurized air or breath is not to be used for performance tests, as this could damage instruments with low measurement ranges. Measurement errors may occur if the instrument is not kept protected from sunlight. Specific safety precautions are given in individual sections of this manual. 1.3 Troubleshooting, maintenance, repairs, disposal The individual responsible for the electrical connections must be notified immediately if the instrument is damaged or if errors occur. This individual must take the instrument out of service until the error has been corrected and ensure that it cannot be used unintentionally. Always unplug the power cord before opening the instrument! This instrument requires no maintenance. Only the manufacturer may perform repairs that require the housing to be opened. 4

The electronic components of the instrument contain environmentally hazardous materials and materials that can be reused. For this reason the instrument must be recycled in accordance with the environmental guidelines of the jurisdiction in question once it has been taken permanently out of service. 1.4 Symbols The symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards: WARNING! This warns you of a potential hazard that could lead to bodily injury up to and including death if the corresponding instructions are not followed. WARNING: This warns you of a potential hazard that could lead to significant property damage if corresponding instructions are not followed. INFORMATION: This indicates that the corresponding information is important for operating the instrument properly. 5

2 Instrument description The AD 1000 absolute pressure transducer / BA 1000 barometer is designed for displaying atmospheric pressure and absolute pressure in such areas as weather stations and airports. At the heart of the unit is an evacuated CuBe chamber that contracts in proportion to barometric pressure. An inductive displacement transducer measures the movement of the chamber without making contact. The pressure port is led through in the AD 1000. 3 Start-up 3.1 Features Although the AD 1000 absolute pressure transducer / BA 1000 barometer is highly robust, it is nevertheless a precision instrument and should be handled with care. Avoid mounting the AD 1000 / BA 1000 in the direct vicinity of any sources of heat or radiation. Ideally, the instrument should be mounted vertically (pressure and vacuum ports should be pointing down) and on a wall not subject to vibration. 3.2 Electrical instrument connections: 0V U/I Observe the required supply voltage (see rating plate). The pressure transducer is protected against reverse polarity of the supply voltage. The signal output is protected against short circuits for a short period. 6

4 Technical data Measurement data measurement ranges AD 1000: 0 50 kpa 0 100 kpa 80 120 kpa 90 110 kpa 100 0 kpa BA1000: 80 120 kpa 85 115 kpa 90 110 kpa 95 115 kpa Margin of error ±1 % (setting limiting value) reference ± 0.5 hpa with respect to sea level temperature-dependent drift in zero 0.04%/ K (within the +10 C...+60 C range) point temperature-dependent drift in 0.04%/ K (within the +10 C...+60 C range) measurement range calibration temperature +22 C long-term drift 0.3 hpa / year Ambient conditions medium air, all non-aggressive gases operating temperature +10 C to +60 C storage temperature -10 C to +70 C relative humidity 0 80 % EMC standards conformity Electrical data power consumption max. 3 VA supply voltage 230 VAC +6 % -15 % 115 VAC +6 % -15 % 24 VDC +20 % -15 % 24 VAC ±10 %, 50/60 Hz CE certificate of conformity on last page of this document output signal 0 to 10 V, 0 to 20 ma or 4 to 20 ma minimum load resistance R L R L 2 k for an output voltage of 0...10 V maximum effect of load resistance = 0.3% maximum output load R B R B 500 for current output output load dependence: < 0.3 % reduction 0 850 m above sea level acc. to DIN ISO 2533:1979-12 p = p b exp[ g n R -1 T -1 (H H b) ] 7

Physical data pressure port Ø 6.5 mm for NW6 tubing electrical connection screw terminals for cables up to 2.5 mm 2 2x PG 7 or 2x PG 11 mounting orientation vertical (if horizontal, use potentiometer 0 to reset) dimensions (w x h x d) 151 x 80 x 73 mm 122 x 120 x 75 mm (option with display) protection class IP54 weight 0.6 kg options ISO factory calibration certificate DAkkS calibration certificate 3½ place LCD Appendix A: Parts in contact with measurement medium Beryllium bronze CuBe2 Araldite CY236 / HY988 Brass CuZn39Pb3 Carbonyl iron KEL (FPM: fluorinated rubber) Viton (tubing) Crastin (PTBP) UHU-Plus endfest 300 binder Loctite 242e For additional specifications and dimension drawings, please visit our website at http://www.halstrup-walcher.de/en/products/measurement-technology/index.php 7100.003864C_AD1000.doc 01/2018 Me 8

5 Certificate of conformity Instruction Manual AD1000/BA1000 9