PRad Target. Chris Keith JLab Target Group

Similar documents
D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Experiment Safety Assessment Document (ESAD) for The Proton Charge Radius Experiment

Review of the Hall B Gas System Hardware. George Jacobs

Baffles and Traps Cryotrap

Hazards associated with the gas system and how to mitigate them

Bubble Chamber Detector System

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Oxford Instruments Austin, Inc.

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Cryogenics of SRF Spoke Cavity Development at SMTF

RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM

Standard Operating Manual

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

SNS BL-13B NPDGamma Experiment

Operating Procedures for the. SAMCO ICP RIE System

Pump out insert (condenser and still lines) overnight with turbo pump

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Cryogenics The Basics. Lesson 2 D. Kashy

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

MEDICAL EQUIPMENT CATALOG

PIP PNE00012 Piping Examination and Leak Test Guide

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

The Gas Attenuator of FLASH

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

High Performance Mass Spectrometers

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Oxford Instruments Austin, Inc.

Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

1)! DO NOT PROCEED BEYOND THIS MARK

Performance of the Liquid Hydrogen Target

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Digester Processes. 1. Raw Sludge Pumping System

SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN

Standard Operating Manual

OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Central Gas System Inquiry. Check List - Detailed Form

NORMAL OPERATING PROCEDURES Operating Parameter Information

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

776 Cryogenic Safety Valve

PERMA-CYL 230/450/1000/1500/2000. Installation Manual Manual # Revision B

Emergency Mobile Unit Medicinal gases everywhere, always on time

Oxygen Contamination

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Basic & Controlled Atmosphere Glove Boxes

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

EXERCISE 2: THE VACUUM SYSTEM

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Procedure of Xenon Transfer

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

/ /

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Cryo-Torr Pump Installation, Operation and Maintenance Instructions

INSTALLATION OPERATION MAINTENANCE

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Introductory Lab: Vacuum Methods

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM

Standard Operating Manual

Cryogenic Materials Operating Procedure and Safety Requirements

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

Notes-PECVD: Chamber 1

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

BASIC OXYGEN FURNACES

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Compressors. Basic Classification and design overview

MANUAL GAS MANIFOLDS

HEALTH AND SAFETY PROGRAM 201 HOT TAP PERMIT/FILLET WELD REPAIRS

Vacuum Pumps. Turbomolecular Pumps F31 F32 F33 F34 F35 F36 F37 F38 F39 F40

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

FPG8601 Force Balanced Piston Gauge

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

TECHNICAL INFORMATION

Dilution Refrigerator manual

Oxygen Dialflow Meter. Instructions for Use

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Models 106-RF / 206-RF Rate of Flow Control Valve

Standard Pneumatic Test Procedure Requirements for Piping Systems

FOAM TANK (1/2) DATA SHEET

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Transcription:

PRad Target Chris Keith JLab Target Group Target Overview & Components Target Software Hazard Analysis and Mitigation Target Status, Performance& Remaining Work Installation Schedule Nov. 12, 2015 PRad Readiness Review 1

PRad Target: Description A windowless, hydrogen gas-flow target Cold hydrogen gas flows (~1 slpm) through a cooled copper cell with beam-entrance and exit orifices Cell has thermometry and pressure tap to estimate gas density Large turbo pumps maintain target chamber vacuum ~ 5 x 10-3 torr Additional turbos up- & downstream maintain beamline vacuum ~10-6 torr 5-axis Motion Mechanism Pumping orifice Cryocooler Pumping orifice Proposal Specs Cell length, 4 cm Cell Pressure, 0.6 torr Temperature, 25 K è 10 18 H/cm 2 Beam Beamline turbo Chamber turbo (1 of 2) Beamline turbo Nov. 12, 2015 PRad Readiness Review 2

PRad Target: Definition OUTSIDE HALL B INSIDE HALL B Gas Panel The PRad Target H2 supply Gate Valve Target Chamber BEAM Cell Detector N2 supply Pumps Vent Nov. 12, 2015 PRad Readiness Review 3

PRad Target: Components The original design from the PRad proposal (a kapton straw ) has been replaced by a large copper cell with kapton windows (orifices for beam) 4 cm of kapton in beam halo Highly non-uniform density profile Non-adjustable dimensions 2 x 25 um of kapton in beam halo More uniform density profile Easy to adjust orifice dimensions Gas IN Gas IN Gas OUT Gas OUT Gas OUT Gas OUT DENSITY PROFILE DENSITY PROFILE Nov. 12, 2015 PRad Readiness Review 4

PRad Target: Components The original design from the PRad proposal (a kapton straw ) has been replaced by a large copper cell with kapton windows (orifices for beam) 2 x 25 um of kapton in beam halo More uniform density profile Easy to adjust orifice dimensions Gas IN Gas OUT Gas OUT DENSITY PROFILE Nov. 12, 2015 PRad Readiness Review 5

PRad Target: Components The cell is suspended in the vacuum chamber from a carbon fiber tube, and positioned on the beam line by a modified, 5-axis motion mechanism. Spares? No. The hydrogen gas is metered into the cell (or directly to the chamber) by a precision mass flow controller, attached to the gas panel. Spares? Yes. Nov. 12, 2015 PRad Readiness Review 6

PRad Target: Components The hydrogen gas is cooled to 25 K by a temperature-controlled pulse tube cryocooler CryoMech PT810 LakeShore Model 336 100 W + 50 W 80 W @ 80 K 18 W @ 20 K Spares? Yes. Spares? Sort of Nov. 12, 2015 PRad Readiness Review 7

PRad Target: Components The hydrogen gas is pumped from the vacuum chamber using TWO large turbomolecular pumps. Pressure goal is 5 x 10-3 torr. Pfeiffer HiPace 3400 Pumping speed N 2 He H 2 Ar CF 4 Pumping speed [l/s] 3200 3400 2400 1600 800 H2: 1700 L/S @ 5 mtorr 0 10-5 10-4 10-3 10-2 10-1 10 0 Pressure [mbar] HiPace TM 3400 MC Slightly smaller turbos are used up- and downstream of the target chamber to keep the beamline vacuum ~10-5 torr. Spares? Sort of Nov. 12, 2015 PRad Readiness Review 8

PRad Target: Control Software CONTROL H2 flow H2 temperature Pulse tube on/off READ Temperatures Pressures Error statuses Nov. 12, 2015 PRad Readiness Review 9

PRad Target: Hazard Analysis Magnetic Fields Oxygen Deficiency Vacuum/Thin Windows Cryogenic Materials Flammable Gas Pressure System Safety (Dave Meekins) Loss of Power Nov. 12, 2015 PRad Readiness Review 10

PRad Target: Hazard Analysis Magnetic Fields The target does not generate any high magnetic fields There are no high fields in the vicinity of the target to affect field-sensitive components such as the turbo pumps for or the rotary valve motor for Pulse Tube Refrigerator All components inside vacuum chamber are non-magnetic Consequence Level: Extremely Low Probability Level: Extremely Low Risk Code before Mitigation: Negligible Mitigation: none required Nov. 12, 2015 PRad Readiness Review 11

PRad Target: Hazard Analysis Oxygen Deficiency The target uses hydrogen gas as its operating fluid, ~ 1 liter. The pulse tube cryocooler contains about 81 liters of helium. Release into Hall B would decrease oxygen levels by less than 0.01%. Consequence Level: Low Probability Level: Low Risk Code before Mitigation: 1 Mitigation: none required Nov. 12, 2015 PRad Readiness Review 12

PRad Target: Hazard Analysis Vacuum/Thin Windows Volume of target chamber is less than 1 m 3 (stored energy < 1000 ft lbf) No thin windows on chamber Consequence Level: Low Probability Level: Low Risk Code before Mitigation: 1 Mitigation: none required Nov. 12, 2015 PRad Readiness Review 13

PRad Target: Hazard Analysis Cryogens No cold components accessible by personnel (no PPE) No condensed gases in system Consequence Level: Low Probability Level: Low Risk Code before Mitigation: 1 Mitigation: none required Risk Code after Mitigation: 1 Nov. 12, 2015 PRad Readiness Review 14

PRad Target: Hazard Analysis Flammable Gas Target system contains about 0.09 g of hydrogen Qualifies as a CLASS 0 installation (< 600 g) Hall B flammable gas monitoring Hydrogen vented out of hall via a dedicated, purged vent line Hydrogen service cylinder will be installed on the Hall B gas pad Inert system prior to any maintenance or repair Consequence Level: High Probability Level: Low Risk Code before Mitigation: 3 Mitigation: NFPA code, ASME 31.12, minimization of ignition sources, VESDA, dedicated vent Risk Code after Mitigation: 1 Nov. 12, 2015 PRad Readiness Review 15

PRad Target: Hazard Analysis Pressure systems Gas panel is only pressure system in the target Constructed according to ASME B31.3 (2012) Pressure relief handled at the gas cylinder, outside the experimental hall Consequence Level: Medium Probability Level: Low Risk Code before Mitigation: 2 Mitigation: Compliance with ASME 31.3 (2012). Routine inspection, testing, and replacement of pressure system components. Risk Code after Mitigation: 1 Nov. 12, 2015 PRad Readiness Review 16

PRad Target: Hazard Analysis Loss of Power The hydrogen supply valves to the target CLOSE Turbopumps stop, gate valves close The pulse tube cryocooler warms up, heater turns off Less than 30 milligrams of H2 gas is trapped inside chamber, with no ignition sources energized. Consequence Level: Medium Probability Level: Medium Risk Code before Mitigation: 3 Mitigation: Cryocooler shuts off, Hydrogen valves close, heater turns off. Risk Code after Mitigation: 1 Nov. 12, 2015 PRad Readiness Review 17

PRad Target: Status & Remaining Work Target system has been assembled and tested with helium gas in the EEL. No major problems to fix. Remaining Work Fiducialize the target cell to survey markers on the target chamber. Develop an EPICS database for the target data Create a GUI and alarm handler for the Hall B counting house. Fabricate extension piping between H2 supply line and gas panel, and vent lines to Hall B vent header. Nov. 12, 2015 PRad Readiness Review 18

PRad Target: Performance 1.2 Helium Data, Nov. 2015 0.02 1 Thickness (10 18 cm -2 ) 0.8 0.6 0.4 Thickness Chamber 0.015 0.01 0.005 Chamber pressure (torr) 0.2 0 0 0 500 1000 1500 2000 2500 3000 3500 Flow (sccm) Goal thickness of 10 18 atoms/cm 2 (1 torr, 40 K) was achieved with 2600 sccm. Chamber vacuum was a bit high, ~ 10 mtorr Beamline vacuum also a bit high, ~10-4 torr. Need to optimize pumping orifices between the chamber and beamline, and possibly add additional ones. Nov. 12, 2015 PRad Readiness Review 19

PRad Target: Installation schedule A detailed installation schedule will require coordination with the Hall B work coordinator, Doug Tilles. Estimated time required is ~ two weeks. May not be contiguous. Transport components to hall (1 day) Install chamber on beam line (1 day) Install gas panel, chillers, etc in Hall B (2 days) Reconnect system components(1 day) New electrical & piping work (5 days) Cool down and check out (1 day) PARK target during HPS Survey and align (2 days) Cool down (1 day) Nov. 12, 2015 PRad Readiness Review 20