Size 6 up to 31.5MPa 1) up to 25 L/min

Similar documents
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Double throttle/check valve, Type Z2FS Series 30 Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

2-way flow control valve Model 2FRM 6

Meter-in pressure compensator, direct operatedtype ZDC

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated, Model 3DR

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Pressure reducing valve, direct operated

PRESSURE SEQUENCE VALVE TYPE UZK

Pressure reducing/relief valve, pilot operated type UZCP10

Pressure reducing valve, direct operated

Pressure relief valve, direct operated Type DBD

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Check valve hydraulically pilot operated

Pressure relief valve, direct operated

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Leak free Pipe Rupture Valve for Excavators

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure relief valve, direct operated

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Axial piston pumps type PVC

Axial piston pumps type PVC

Pressure relief valves

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

3-Way Pressure-Reducing Cartridge, Size 2 4

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Hand & mechanical directional valves

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Air preparation units

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Precision pressure regulators LRP/LRPS

Series MX pressure regulators 3/

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Monoblock directional control valves ML - Directional control valve

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Digital directional & flow control valves D-DF(R)G

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

EXH. Specifications. Descriptions. Min. working pressure MPa

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Change-Over Pressure Filter DFDK

Fixed Displacement Plug-In Motor A2FE

Full Range Pressure Compensating Variable Flow Control

3-Way Safety Block DSV

BACK PRESSURE / SUSTAINING

Safety and Shut-off Block SAF/DSV

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

DNS. Monoblock directional control valves DNS - Directional control valve

BACK PRESSURE / SUSTAINING

Flow control valves Series RFU - RFO 2/

Cooler-Bypass Thermostat Valve, Size 16

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

SystemStak Valves. ISO4401 Size 02

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Directional Controls

Hand lever valves VHER

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Directional Control Valves Technical Information Model 1500

Safety and Shut-off Block SAF/DSV

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

PLD 03 T A CASAPPA S.p.A.

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Pressure-controlled shut-off valve type CNE

Flow and check valves Logic valves series 551. Brochure

Pressure-Relief Cartridge Valve, Size 4

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

CASH VALVE TYPE KP BACK PRESSURE VALVES

Proportional Throttle Cartridges, Size 16

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Nikuni KTM Series Pumps

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Rate of Flow Valve Series 120

Chapter 10: Bidirectional Flow Controls

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Directional Controls

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Pilot Operated Check Valves

directional control valve series cv691

Nikuni KTM Series Pumps

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Transcription:

BEIJING HUADE HYDRAULICS INDUSTRIAL GROUP CO.,LTD. 2-way flow control valve Type 2FRM 6 Size 6 up to 31.5MPa 1) up to 25 L/min RC:28160/12.2004 Replaces RC28160/05.2001 Features: - External closing of the pressure compensator, optional - Check valve, optional - Rotary knob with scale - Lockable, optional 1) When used in conjunction with a rectifier plate up to 21 MPa Function, section: General: The flow control valve type 2 FRM is a 2-way flow control valve. It is used for maintaining a contant flow, independent of pressure and temperature.the valve basically comprises of housing (1), rotary knob (2), orifice (3),pressure compensator (4) and an optional check valve. Flow control valve type 2FRM 6 B..-20B/M (without external closing, without check valve) Flow from port A to B is throttled at throttle position (5). The throttle cross-section is varied by turning rotary knob (2).In order to keep the flow constant, independent of pressure, a pressure compensator (4) is fitted in port B downstream of the throttle position(5).the compression spring (6) presses orifice (3) and pressure compensator (4) outwards against their respective stops and thus keeps pressure compensator (4) in the open position when there is no flow through the valve. When fluid flows through the valve, the pressure acting in port A applies a force to pressure compensator (4)via orifice (7).The pressure compensator (4) moves into the compensating position until the forces balance. If the pressure in port A rises, pressure compensator (4) moves in the closing direction, until a balance of forces is once more attained. Due to this continuous compensating action of the pressure compensator, a constant flow is obtained.in order to control a flow through the valve in both directions, a rectifier sandwich plate type Z4S 6 may be fitted below this flow control valve. Type 2FRM6B36-20B/...M... PT

Type 2FRM 6 A..-20B/..R The function of this valve is basically the same as that of valve type 2FRM 6 B..-20B/..M. However, this type of flow control valve is provided with an external port permitting the pressure compensator (4) to be connected to via port P(11). The external pressure acting in port P(11) via orifice (10)holds pressure compensator (4) closed against the force of compression spring (6). When the connected directional valve (9) is actuated to permit flow from P to B,closed loop control is achieved as with type 2 FRM 6 B. Thus a jump on start-up is avoided. This version with external closing of the compensator may only be used for meter-in control. Free return flow from port B to A is via check valve (8). Actuator Actuator Symbols: 2-way flow control valves (simplified, detailed) Type 2FRM6B..-20B/..M Type 2FRM6B..-20B/..R Type 2FRM6B..-20B/..M Type 2FRM6A..-20B/..R Type 2FRM6B J20B/ M Type 2FRM6A J20B/ M Type 2FRM6B J20B/ M Type 2FRM6A J20B/ M PU

Ordering details: 2-way flow control valve 2FRM6-20 B / * With external closing of the pressure compensator (repression of jump at start) = A Without external closing of the pressure compensator = B Lockable rotary knob with scale = 3 Rotary knob with scale = 7 Zero position labels at port P=6 Zero position labels at port A=7 Zero position labels at port T=8 Zero position labels at port B=9 Series 20 to 29(20 to 29: unchanged installation and connection dimensions) = 20 Technology of Beijing Huade Hydraulic =B Further details in clear text No code = Mineral oil V = Phospate ester (other seals on request) R = with check valve M = without check valve Flow (A to B) 0.2 Q = up to 0.2 L/min 0.6 Q = up to 0.6 L/min 1.5 Q = up to 1.5 L/min 3 Q = up to 3.0 L/min 6 Q = up to 6.0 L/min 10 Q = up to 10.0 L/min 16 Q = up to 16.0 L/min 25 Q = up to 25.0 L/min Technical data: 2-way flow control valve (for applications outside these parameters, please consult us!) Pressure fluid Mineral oil(for NBR seal) or Phospate ester (for FPM seal) Pressure fluid temperature range -30 to +80 Viscosity range mm 2 /s 10 to 800 Flow q V max L/min 1.5 3.0 6.0 10.0 16.0 25.0 Flow q V min to10mpa L/min 0.015 0.015 0.025 0.05 0.07 0.1 Flow q V min to 31.5MPa L/min 0.025 0.025 0.025 0.05 0.07 0.1 Pressure difference p for free return flow B A MPa 0.1 0.12 0.17 0.25 0.38 0.66 Minimum pressure difference MPa 0.6 to 1.2 Pressure stability up to p = 31.5 MPa % 2 Qmax Maximum operating pressure at port A MPa to 31.5 Contamination m 25 Q 5L/min 10 Q 0.5L/min Weight Kg approx 1.3 Attention! The pressure loss from P (at the inlet of the directional valve) to A (at the inlet of the flow control valve) is noticeable at low flows. PV

Characteristic curves:(measured at v = 41 mm 2 /s and t = 50 ) Flow in relationship to the scale setting (flow control from A to B) Flow in L/ min Scale divisions p-q v - characteristic curve B to A; Pressure difference in MPa qml/min closed orifice Flow in L/min Temperature relationship at p = 2 MPa Temperature in ` qml/min Pressure difference in MPa Flow - pressure relationship Input pressure in MPa Temperature in Temperature in QM

Unit dimensions: (Dimensions in mm) View"Y" Type 2FRM6B 1 Lockable rotary knob with scale 2 Nameplate 3 Inlet "A" 4 Outlet "B" 5 O-ring 9.25 x 1.78 for ports A, B, P and T 6 Space required to remove key 7 Rotary knob with scale (adjustment element "7") View"Y" Type 2FRM6A Subplates: see page 68 G341/01 G1/4" G342/01 G3/8" G502/01 G1/2" G341/02 M14x1.5 G342/02 M18x1.5 G502/02 M22x1.5 QN

Notice 1. The fluid must be filtered. Minimum filter fineness is 20 µm. 2. The tank must be sealing up and an air filter must be installed on air entrance. 3. Products without subplate when leaving factory, if need them, please ordering specially. 4. Valve fixing screws must be high intensity level (class 10.9). Please select and use them according to the parameter listed in the sample book. 5. Roughness of surface linked with the valve is required to. 6. Surface finish of mating piece is required to 0.01/100mm. QO All rights reserved-subject to revision