combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Similar documents
combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Model EXAxt AV550G. Averaging Oxygen Analyzer

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Autocalibration Systems For In Situ Oxygen Analyzers

PRODUCT CONFORMITY CERTIFICATE

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Zirconia Oxygen Analyzer Systems

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Autocalibration Systems for In Situ Oxygen Analyzers

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

FAS-W. Features. Applications. Automatic condensation hygrometer

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

BUBBLER CONTROL SYSTEM

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

SonoMeter 30 Energy Meters

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

FLAMMABLE GAS SENSOR/TRANSMITTER

BUBBLER CONTROL SYSTEM

Oxygen Flue Gas Analyzer BA 2000

Technical Data Sheet MF010-O-LC

HumiSys HF High Flow RH Generator

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Type2 Oxygen probe system for Nexus NX6100 and PPC6000

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pressure measurement is a family affair

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Operation & Maintenance Manual GDS-68XP

High-performance submersible pressure transmitter For level measurement Model LH-20

CONTENTS OVERVIEWS PRODUCT INFORMATION

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Pressure switch Type BCP

RAM Operation Manual

Your local gas generation partner. Precision series Modular gas generation solution for GC.

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Laser Gas Analyzer LG2000. The Laser Technologies

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

780S Ultra High Purity Series

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Royce Interface Level Analyzer and Sensors

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

ISM-3 User Manual PBI D 04/2013

RAM 4021-DPX Operation Manual

Oxygen & Binary Gas Measurement and Analysis

Protec P3000 (XL) Helium Sniffer Leak Detector

Mass Flowmeters. Mass Flowmeters for Gases

Instruction Manual. Biogas Analyzer InCa Bio 04

High-performance submersible pressure transmitter For level measurement Model LH-20

How to specify a product. Process Sensors and Mechanical Instruments

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

IN-SITU ZIRCONIA OXYGEN ANALYZER < ZIRCOMAT-C >

Precision pressure sensor Basic version Model CPT6020

Additel 761 Automated Pressure Calibrators Selection Guide

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Pneumatic high-pressure controller Model CPC7000

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Mass Flow Meter (MFM) for Gases

EasyLine Continuous Gas Analyzers. So smart, they re simple

Pneumatic high-pressure controller Model CPC7000

Series Environmental Chambers

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

EPP4 Pressure Regulator Basic G 1/4"

RAM 4021 Operation Manual

FTC130 Transmitter. Operating Manual

GAS FUEL VALVE FORM AGV5 OM 8-03

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

For the highest operational safety around the clock

We measure it. For gas and water installers. testo hpa. bar

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Instruction Manual. Analyser AMS for AMS ZrO 2 - Probes

Level transmitter LT 100

Flow Measurement SITRANS F C

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Features. Description

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

WITT-GASETECHNIK GMBH & CO KG

Installation and Operation Manual

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Transcription:

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen within boilers and furnaces. The wide range of products available have the measurement capability, performance and quality to meet most industrial applications. Features & Benefits Simple installation and operation - 4-key user interface controls all functions Outstanding sensor reliability - Robust design with large surface area and rigid bonding High product confidence - 24 month complete probe warranty Proven performance - TÜV approved Service and maintenance carried out on-site - All parts are field replaceable Straightforward integration in plant control system - Modbus communications capability Measurement systems for most applications - Wide range of product options available Simple User Interface Simple push-button operation combined with a clear LED display enable complete electronic control of the probe functions. Full setup and diagnostic information is also accessible through the user interface. Serial Communications Genesis probes can communicate using the RS485 modbus protocol, for straightforward integration into the plant DCS. There are also both 4-20 ma analog and relay outputs.

Analyzers the world s first fully-integrated stand-alone, flue gas oxygen analysis system Unique Flexibility Genesis uniquely mounts the user interface onto the probe itself. This enables complete local control at the measurement location and reduces installation costs. Alternatively, the user interface can be detached and located for remote operation. Rugged Sensor design The sensor is manufactured to the highest possible standards - allowing a minimum 2 year warranty. The sensor design gives a large surface area and an excellent bond between the zirconia and stainless steel holder. Probe filter assembly The probe filter simply fits in place with 4 retaining screws, and maintains the integrity of the probe. Flame arrestors are also available. Versatile probe and mounting Genesis oxygen probes are available in various lengths with a range of mounting flange options. Universal compatibility The universal control unit is fully compatible with all genesis oxygen probes. It provides remote control, operation and displays readings for the measurement probe. In addition, the universal control unit is fully compatible with existing zirconia sensor oxygen probes from most manufacturers.

Product Range General Purpose Flue Gas Temperature Reading Probe Type Control Unit Type Display Low Temperature 0-600 C/ 32-1112 F Integrated Genesis g1200 Integral with probe Low Temperature 0-600 C/ 32-1112 F Remote Genesis g1210 Genesis g1220 High Temperature 600-1400 C/ 1112-2552 F Remote Genesis g1230 Genesis g1220 g1200 Stand-alone, Low Temperature Fully-integrated Probe The g1200 is the world s first fully-integrated oxygen analysis probe. The g1200 combines the measurement probe with the control unit into a single, fully integrated system. For applications where probe access is straightforward, the g1200 is the ideal choice as it reduces both installation time and costs. g1210 Low Temperature Probe The g1210 measurement probe is capable of direct, in-situ measurement in all combustion processes up to 600 C/1112 F. Display of measurement readings and probe diagnostics is made remotely from the Universal Control Unit (g1220). The g1210 is ideally suited where normal access to the probe is restricted or environmentally hostile. g1230 High Temperature Probe The g1230 measurement probe is capable of in-situ oxygen measurement in higher temperature combustion processes (such as furnaces and process heaters) up to 1400 C/2552 F. The probes come in varying lengths, with a choice of protection sheaths for specific temperature ranges. Display of measurement readings is made remotely using the Universal Control Unit (g1220). g1220 Universal Control Unit The universal control unit has identical functionality to the control module of the g1200, but is mounted in the plant control room or other accessible location for easy access. Control, display and diagnostics information Simple user interface with LED display User programmable for maximum flexibility Automatic fault detection Modbus communications Small and compact IP65/NEMA 4 protection

Applications Combustion Efficiency Combustion Control Excess Air Measurement Pollution Control Specifications g1200 and g1210 Low Temperature Probes Measuring Range: 0 to 5, 0 to 25 % Vol O 2 selectable Accuracy: ±1 % of full scale Repeatability: ±0.5 % of full scale on analog outputs Response Time: 90 % of full scale within 5 seconds Measuring Method: Zirconia oxide sensor Flue Gas Temp Range: 0 to 600 C/32 to 1112 F Probe Lengths Options: 0.4/1.0/1.5/2.0 m/1.3/3.3/4.9/6.6 ft Weight: (g1200) 8.8 to 15.1 kg/19.4 to 33.3 lb Weight: (g1210) 6.8 to 13.1 kg/15 to 28.9 lb g1230 High Temperature Probe Measuring Range: 0 to 5, 0 to 25 % Vol. O 2 selectable Accuracy: ±1 % of full scale Repeatability: ±0.5 % of full scale on analog outputs Response Time: 90 % of full scale within 5 seconds Measuring Method: Zirconia oxide sensor Flue Gas Temp. Range: Type R - 600 to 1400 C* / 1112 to 2552 F* Type K - 600 to 900 C /1112 to 1652 F Probe Lengths Options: 0.6 or 1.0 m/ 24 or 40 inch Weight: 2.5 kg (600 mm probe) - 5.51 lb (23.6 " probe) 2.8 kg (1000 mm probe) - 6.2 lb (39.4 " probe) *Reduced probe life may result if operated above 1250 C / 2282 F g1200 Probe Control Unit/g1220 Universal Control Unit Display Type: Parameters: Single-line 4 digit LED O 2 concentration; Calibration Gas Concentration; Cell Temperature; Fault Messages; Cell/Thermocouple Information Analog Outputs: Single channel isolated 0 to 10; 0 to 20; 2 to 20; 4 to 20mA menu selectable Ranges: Selectable range 0 to 5; 0 to 25% v/v O 2 Serial Output: RS485 Modbus protocol (2-wire, half-duplex) Alarm Relays: Single pole changeover 2 A at 30 V a.c./d.c. Alarms: High/Low customer selectable; System Fault; Maintenance/Cal. in Progress Fault Indication: LED indication and error codes Calibration: Option to track or hold Calibration Types: Manual; *Automatic; *Remote Trig. Power Supply: 85 to 264 V a.c.; 48 to 62 Hz Power Rating: 250 W *Requires optional Automatic Calibration Gas Control Unit Compatibility: All Genesis type probes Other zirconia type oxygen probes Max. Distance to Probe: 300 m/ 985 ft EMC: Conforms to EN 50 081, EN 50 082 Safety: Conforms to EN61010-1 Dimensions: 130(l) x152(w) x153(h) mm/ 5.12(l) x6(w) x2(h) in Weight: (g1220) 2.7 kg/5.95 lb Continuous product development may make it necessary to change these details without notice 115/4.53 Industries Bio-fuel Boilers Package Boilers Power Generation CCGT Petrochemicals Process Industries Pharmaceuticals Incineration Furnaces g1200 Probe g1230 Probe 125.5/4.94 150/ 5.9 115/4.53 150/ 5.9 125/4.92 410/16 243/ 9.6 115/4.53 463/18.23 g1210 Probe 190/ 7.5 62/2.5 g1220 Control Unit 122/4.80 556 or 953/ 5/0.2 21.9 or 37.5 0.4 m/1.3 ft 1.0/1.5/2.0 m 3.3/4.9/6.6 ft 0.4 m/1.3 ft 1.0/1.5/2.0 m 3.3/4.9/6.6 ft 7/0.28 130/5.12 All dimensions are given in mm/inches except where stated 27.5/1.08

Further Information U.K. Dronfield, Derbyshire S18 1DJ Telephone: +44 (0) 1246 417691 Facsimile: +44 (0) 1246 290274 E-Mail: combustion.info@landinst.com U.S.A. 10 Friends Lane Newtown, PA 18940-1804 Telephone: +1 215 504 8000 Toll Free: (in USA) 800 523 8989 Facsimile: +1 215 504 0879 E-Mail: combsales@landinstruments.net Web: www.landinstruments.net Italy Land Instruments Srl Via dell Industria, 2 20037 Paderno Dugnano, Milano Telephone: +39 02 91 08 0020 Facsimile: +39 02 99 04 0418 E-Mail: info@landinst.it Web: www.landinst.it France 7 Parc des Fontenelles 78870 Bailly Telephone: +33 (0)1 30 80 89 20 Facsimile: +33 (0)1 30 80 89 21 E-Mail: combustion@landinst.fr Poland ul. Michalowskiego 5/2 31-126 Krakow Telephone: +48(0) 12 632 82 62 Facsimile: +48(0) 12 632 24 74 E-Mail: land@land.com.pl Web: www.land.com.pl Mexico Av. Horacio 1132 Planta Baja B Col. Polanco, D.F. 11550 Telephone: +52 (0) 55 5281 1165 Facsimile: +52 (0) 55 5281 5364 E-Mail: ventas@landinstruments.net Accessories g1270 Automatic Calibration Unit To help with compliance, as well as reducing maintenance and increasing accuracy, this unit automatically controls the calibration gas (both zero and span) to the Genesis probe at programmed intervals. The g1270 functions are controlled (as with the probe) by the control unit. Specifications Genesis g1270 Automatic Calibration Unit Dimensions: 300x200x155 mm/11.8x7.9x6.1 in (HxWxD) Weight: 6 kg/13.2 lb Operating Temp: 0 to 50 C/32 to 122 F Enclosure Rating: IP65/NEMA4 Power Supply: 110 V or 240 V a.c. 50-60 Hz 10 VA Supply Tolerance: -10 % +20 % Gas Inlet Pressure: 1.7 to 2.0 bar/25-30 psi Gas Outlet Flow: 3.0 litres/min. for g1200 & g1210 0.8 to 1.0 litres/min. for g1230 Pressure Switch: 1 bar/15 psi trip pressure Slave Relays: 2- galvanically isolated changeover contacts Continuous product development may make it necessary to change these details without notice Reference Air Supply Units To achieve the best measurement performance it is essential that reference air with 20.9 % Oxygen is present at the measurement cell. Land have two options for providing reference air: an air regulator system or an electric air pump. Hazardous Area Applications The Genesis range of hazardous area measurement systems are designed for flue gas temperatures ranging between 20 C and 1250 C/68 F and 2282 F. Genesis systems capably meet the unique measurement conditions demanded by explosive environments. For complete details request the dedicated information genesis hazardous area flue gas oxygen analysis systems (ref. PDS 193) has a comprehensive range of Combustion and Environmental Monitoring Instrumentation. www.landinst.com/comb/ TÜV approved Copyright 2000-2004 Approval applies to products designed and manufactured in the UK Approval applies in the USA PDS181/10/04