DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Similar documents
DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Best Practice Guide, Servomex 2700

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

SERVOTOUGH Oxy (1900)

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Oxygen Analyzer DF-310E OPERATOR MANUAL

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

User and Installation Manual

Columbus Instruments

Model PDT Dewpoint Transmitter

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

High Pressure Breathing Air Compressors

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

NanoTrace Moisture Analyzer

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Pressure Automated Calibration Equipment

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

TECHNICAL INFORMATION

NanoTrace Moisture Analyzer

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Technical Information

Tightness control TC. Product brochure GB 3 Edition AGA

UNDERSTANDING, ACCELERATED

INSTALLATION & MAINTENANCE INSTRUCTIONS

PERFORM Operating Document

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Nitrogen Generation Systems

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

BUBBLER CONTROL SYSTEM

1 General information Device description Scope Task definition Explosion protection, Device variants...

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

GasSense NDIR User Manual

SERVOPRO MultiExact Gas Analyser. Operator Manual. Part Number: A Revision: 9 Language: UK English

TECHNICAL INFORMATION

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Calibration and Switching Module

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Heavy Duty Dissolved Oxygen Meter

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Autocalibration Systems For In Situ Oxygen Analyzers

Gas density monitor With integrated transmitter Model GDM-100-TI

PERFORM Operating Document

780S Ultra High Purity Series

EPP4 Pressure Regulator Basic G 1/4"

with O 2 Controller Instruction Manual

Inert Air (N2) Systems Manual

Valve Proving System VDK 200 A S06*

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

AMT-Ex Dewpoint Transmitter

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2223) Oxygen Transmitter. Installation Manual. Revision:

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Pneumatic high-pressure controller Model CPC7000

FTC130 Transmitter. Operating Manual

Tightness controls TC 1 3 and TC 4

Mass Flow Controllers

This test shall be carried out on all vehicles equipped with open type traction batteries.

Instruction and Maintenance Manual

WITT-GASETECHNIK GMBH & CO KG

BI-680 Online Dissolved Oxygen Controller Instruction Manual

NGP-250/500 Nitrogen Generator Quick Start Guide

The Air Liquide Gas System Equipment Brochure

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

xendos 1800 Oxygen Analyser The xendos 1800 is a stable, accurate and highly specific oxygen analyser for safe areas.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

GPR-1900 MS PPB Oxygen Analyzer

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

EasyLine Continuous Gas Analyzers. So smart, they re simple

Valve Proving System VDK 200 A S02

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

High-performance submersible pressure transmitter For level measurement Model LH-10

GPR-1900 PPM Oxygen Analyzer

GAS FUEL VALVE FORM AGV5 OM 8-03

Operating Instructions Part No

Operating Instructions

TECHNICAL INFORMATION

Instruction and Maintenance Manual

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

ACV-10 Automatic Control Valve

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Additel 761 Automated Pressure Calibrators Selection Guide

RAM Operation Manual


GPR-1500 GB Glove Box PPM Oxygen Transmitter

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

Application Note AN-107

DPC-30 DPC-100. Reference Manual

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Additel 761 Automated Pressure Calibrators Selection Guide

Highest Quality. Gas Chlorination Systems

Transcription:

PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic grade gas for quality control. FEATURES Non-depleting sensor with 5 year sensor warranty Factory calibrated Minimum maintenance Fast response time and recovery from upset condition Suitable for multiple background gases with a single unit 200ppt Lower Detection Limit Optional calibration systems APPLICATIONS Quality control Leak detection

KEY FEATURES ELECTRICAL SAFETY Low Cost of Ownership Sensor is highly stable and requires annual SPAN calibration only. No programmed cell replacement required. Sensor warranty of 5 years as standard. Highly Sensitive Lower detection limit (LDL) of 200ppt. Sensitivity of 100ppt. Multiple Options Calibration system options, supplemental battery power. EC DIRECTIVE COMPLIANCE UTILITIES REQUIRED Electrical safety to IEC 61010-1: Ed 2. The product is rated for Installation Category II in accordance with IEC 60664-1. The product is rated for Pollution Degree 2 in accordance with IEC 60664-1. The DF-550E is in compliance with: Low Voltage Directive (2002/73/23EEC). EMC Directive (2001/89/336/EEC). Power ZERO Gas SPAN Gas SPECIFICATIONS 110V ac or 220V ac 50/60 Hz Not required Any blend of O 2 in N 2 within the operating range of the sensor Gas Type: O 2 TECHNOLOGY PERFORMANCE Operating ranges: Smallest recommended output range: Intrinsic error (accuracy): Response time (T 90 ) at sample flow rate: Zero drift/month: Span drift/month: Lower detection limit (LDL): Upset recovery time: Coulometric non-depleting electrochemical sensor 0-20ppb up to 0-10ppm * Any range between the above ranges ** Can handle excursions up to 100 ppm for up to 15 minutes at which time the sensor shuts down to prevent damage 0-20ppb +/- 3% of reading or +/- 0.1ppb <15 seconds at 0.7litres/min Negligible Negligible 200ppt <5 minutes to return to within 10ppb of previous stable reading OUTPUTS/INPUTS Ouput: Output range: Alarms: Dual scale range: Gas scale factor: Non- Isolated 4-20mA dc, 0-1, 0-2, 0-5, or 0-10V dc (Analogue output can be configured to freeze during calibration) Any range between 0-20ppb to 0-10ppm Electrolyte condition and temperature Two user selectable secondary analogue output ranges for rescaling the output once the primary range is exceeded Background gas compensation for gases other than N 2 or Ar Page 2

SPECIFICATIONS CONT. OPTIONS Stab-El sensor system: Concentration alarms: Low flow alarm: Relay contacts: Analogue output: Serial communication: Mounting: High purity pressure regulator: High purity flow control valve: Downstream isolation valve: Enables operation with trace levels of acid gases or ionic contamination.samples containing trace samples of acidic components must use the Stab-el option Up to 4 non-latching, independently assignable to alarms or calibration-in-process indicator. SPDT contacts rated for 5amps at 30V dc 1 audible/visual flow alarm Up to 4 independently assignable contacts rated at 0.3Amps at 30V dc Isolated 4-20mA dc, 0-1, 0-2, 0-5, or 0-10V dc RS232 or RS 485 Two-Way Serial Communications Panel mount or 19 rack mount 3000psig inlet capacity; 0-15psig adjustable outlet pressure; requires 5psig minimum inlet pressure (1/4 inch VCR compatible fittings), supplied mounted or loose Ultra high purity bellows valve for upstream isolation shutoff and flow control (1/4 VCR compatible fittings) Isolates analyser from atmosphere when disconnected from process Stainless steel outlet: Recommended for flammable samples such as H 2 Automated calibration system: Auto control of user-cal components: Manual calibration system: High capacity purifier: Provides menu driven automatic zero and span valve switching, pneumatic diaphragm valves and zero purifier in a small on-board package, only 12.5 depth behind location of optional panel (requires 70-100psig pneumatic supply.) Software with switched 6V dc power for control of external, span/zero solenoids and valves. Provides manual quarter-turn springless diaphragm valves and zero purifier in an orbital butt welded assembly that is compactly integrated on the rear panel of the analyzer to optimize portability Recommended for applications where source gas purity can be >10 ppb or sample sources are frequently switched, such as all portable applications. Provides 30 times higher capacity than the standard purifier N 2 case purge: Interlocked purged enclosure recommended for flammable samples such as H 2 Supplemental battery input power: SAMPLE GAS Permits portable operation independent of AC power Temperature: 0 C to 50 C (32 F to 122 F) Dewpoint: 5 C (9 F) below minimum ambient Condition: Oil free, non-corrosive, non-condensing, non-flammable Particulates: Filtered to 2µm Vent: Vent to atmosphere Sample flow: 0.24 to 0.7l/min Sample pressure: 15 to 25psig (2.03 to 2.72 BarA) AMBIENT CONDITIONS Temperature: Relative humidity: Altitude: +0 C to +45 C (stable) 0 to 95% RH non-condensing 2000 meters above sea level NOTE: For samples containing above trace levels of acidic components contact Servomex for sample preconditioning options Page 3

DESCRIPTION Options Power lead: There are 3 options for the Power lead: 22-28V dc, 1Amp (max) 100/120V ac 220-240V ac Outputs: Analyser supplied with a non-isolated 4-20mA & 0-1, 0-2, 0-5, or 0-10V dc as standard American Analogue and voltage output Mounting: The DF-550E comes standard with a benchtop cabinet but can be panel and rack mounted Benchtop User manual: English SERVICE & SUPPORT For new installations and replacement of older Servomex and competitor products, we will work with you to develop a bespoke service and support package, ensuring full measurement availability and plant operation within your timescales and budget. SAMPLE WETTED MATERIALS Analyser fitted with: Stainless steel G10 Epoxy Polypropylene Tygon DIMENSIONS All dimensions shown in inches (mm)

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.