CalCheck. Instrument User Manual V1.8

Similar documents
PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

30T A/Manual Hydraulic Shop Press

GasCheck G 1, 2 and 3 (Graphical) User Manual V1.7

Installation, Operation, and Maintenance Manual

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Dri-Line Mk3 Monnier Compressed Air Drain Trap

OPERATING INSTRUCTIONS

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Pressure Regulators. Instructions for Use

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

1805 Series Relief Valves

Flowmeter. Original operating manual DFM

AREA VALVE SERVICE UNITS

Dialflow Regulator. Instructions for Use

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Oxygen Dialflow Meter. Instructions for Use

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

776 Cryogenic Safety Valve

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

SB-E ISS.01. Operation Manual: KB-522 & KB-522-SS Pressure Feed Cup E P ITW Finishing Systems and Products

Installation, Operation, and Maintenance Manual

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

GasCheck G. Instrument User Manual V2.3R

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

ATS430 turbidity sensor Retractable insertion assembly

OPERATING INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Installation, Operation, and Maintenance Manual

Agilent 1220 Infinity II LC Mobile Upgrade Kit

GILMONT ACCUCAL FLOWMETERS

Techcon Systems TS1258 Pressure Pot

Pressure Regulator. Instructions for Use

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

CSA Sample Draw Aspirator Adapter Operator s Manual

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

RayPette Plus Autoclavable Pipette. User Manual

Peak Pressure Indicator MSI-3

Type BBS-03, BBS-05, BBS-06, BBS-25

Micro Dial-Flowmeter. Instructions for Use

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

HATFIELD. Continuing the Tradition SEMI-AUTOMATIC SHOTGUN INSTRUCTION MANUAL

Constant Pressure Crude Oil Container Model CPCCP

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

User Information Sheet 013

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

v. Size shall be specified on drawings.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

The pipettes cover a volume range from 0.1µl to 10ml.

GREIG FILTERS, INC. OPERATION MANUAL

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

12S 1st Stage. -Maintenance Procedure-

Installation, Operation, and Maintenance Manual

453 Series Steam Heated Vaporizing Regulator

Installation Instructions

Pressure relief valve

SIMPLAIR PIPING TOOL. JXT Company

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Pipettor. User Manual

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

AYLESBURY 'KB' TYPE FLOAT VALVES

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

PRECISION GAS MIXTURES

Techcon Systems TS1254 Pressure Pot

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

MODEL CALIBRATION GAS DELIVERY SYSTEM

SCA Series Inverted Bucket Steam Traps

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

RAM 4021 Operation Manual

Operating Instructions

System Pressure Manager Standard & System Pressure Manager Plus

TWIST-IN STEPPER SF-S0636 USER MANUAL

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Standard Operating Procedure Measuring & Testing Equipment

High Precision Gauge Pressure Indicators

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Mainsboost Installation, Operation & Maintenance Instructions

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

User manual. ZX trolley.

Installation, Operation, and Maintenance Manual

Transcription:

CalCheck Instrument User Manual V1.8 Unrivalled Part number: 21518 Detection.

Part number: 21518

Declaration of conformity Manufacturer:, The Way, Fowlmere, Cambridge, England. SG8 7UJ Product: CalCheck Product description: an easy to use reliable tool for the self calibration of gas and leak detection instruments, giving you peace of mind and confidence in the accuracy of the measurements you rely on. Directives: 97/23/EC Pressure equipment Standards: BS EN 61010-1:2001 Safety requirements for measurement, control & lab equipment BS EN ISO 9001:2008 Quality management systems BS EN ISO 11118 Pressure vessel I the undersigned herby declare that the equipment specified above conforms to the stated Directives and Standards. Signed By: Name: Mark Stockdale, Position: Technical Director Date: 23 rd April 2007 Product Safety: The pressurised cylinder used has been tested by our supplier in accordance to ISO 1118 and tested by them to their procedure number TPED B 8001. Page 1 of 12

Contents Declaration of conformity... 1 Statement... 3 Principals of operation... 3 Quality assurance... 3 Disposal... 3 Calibration facility... 3 Responsibility for use... 3 Packing list... 4 CalCheck features... 5 Introduction... 6 Getting started... 7 Changing gases and standard calibrated leaks... 8 Troubleshooting... 9 Spares... 10 Technical specification... 11 Construction... 11 Gases available... 11 Leak rates available... 11 Calibration... 11 Extras... 11 Weight & dimensions... 11 Service... 12 Page 2 of 12

Statement Principals of operation CalCheck is an easy to use reliable tool for the checking of calibration on gas and leak detectors, giving the user peace of mind and confidence in the accuracy of the measurements they rely on. Quality assurance CalCheck has been manufactured in compliance with ISO9001:2008, which ensures that the equipment supplied to our customers has been designed and assembled reproducibly, and from traceable components. Disposal Dispose of CalCheck and its components in accordance with all local and national safety and environmental requirements. Calibration facility offer a calibration service including the issue of certification using equipment which are themselves traceable to UK national standards. Ion Science recommends that the standard calibrated leak fitted to a CalCheck is returned to Ion Science on an annual basis to ensure continued accuracy. Responsibility for use NB: Gas canisters are pressurised and should be treated as such. Do not puncture or incinerate dispose of safely. Store equipment in a cool dry environment. Do NOT use with oxygen gas (cylinders). Only use authentic factory supplied spares for proper, validated and safe operation. Never remove or alter circlips, O-rings or gas delivery pipework. Page 3 of 12

Packing list Please take a little time to check the contents in the CalCheck case before removal. Item Description Qty 1. CalCheck base with handle 1 2. Gas can with protective cap 1 3. Standard calibrated leak (pre fitted) in a transit box 1 Total weight of a packed CalCheck is 2.4 kg for all varieties. If the carton appears damaged in any way please contact the carrier. If any goods appear to be damaged or missing please contact Ion Science and arrange for the return of the whole CalCheck carton including documentation within 3 days. The CalCheck is warranted against manufacturer defects. Page 4 of 12

CalCheck features Gas Can Handle Label Gauge Adjust button Test port Base GasCheck / Gas Check R2pc Hydrosteel GasCheck / LeakCheckSF 6 Page 5 of 12

Introduction CalCheck is an easy to use and convenient means of traceably checking the normal response of gas leak detecting instruments such as 's Gas Check, GasCheck R2pc, GasCheck SF 6 and Hydrosteel as well as helium mass spectrometer leak detectors. CalCheck incorporates a Standard Calibrated Leak, which has a specified flow rate at 1 bar gauge pressure, through which the gas from the can leaks enabling the user to present their instrument a known leak testing its accuracy. CalCheck users benefit from its versatility as the same base unit can be used for calibration with many different gases and at many different leak rates. Both the gas and the standard calibrated leak can be easily changed in the field. Ion Science can supply any non-corrosive gas at a variety of concentrations and a wide variety of standard calibrated leaks are available, the smallest being 1 x 10-4 ml/sec. Page 6 of 12

Getting started Within 5 minutes of unpacking a CalCheck the user can be making reliable self calibration checks. 1. Remove the protective cap from the gas can. Make sure that the spigot is in place, if not see troubleshooting. 2. Gently hand screw the gas cylinder into the brass receptive plate, do not over tighten as the screw may strip 3. Check that the standard calibrated leak is in position, attached to and behind the test port and is finger tight. 4. Push down on the top of the gas cylinder. The needle in the gauge should quickly rise into the white section, if not see troubleshooting 5. Press the adjust button until the needle moves into the green area of the gauge or 1 bar. 6. CalCheck is now ready for use. Present your detection instrument to the test port for checking. NB: If using a CalCheck to calibrate an Ion Science Hydrosteel instrument the process is the same as above except the test port in this case contains a thread. At step 6, handscrew the free end of conduit connected to the Hydrosteel to the test port and check the response is within limits presented in the Hydrosteel manual. CalCheck is designed for use in normal indoor environmental conditions, avoid condensation and dust ingress. It is NOT designed for use with oxygen. Page 7 of 12

Changing gases and standard calibrated leaks Gas canisters simply unscrew from the CalCheck vertically. The gas cans provided have a standard thread and integral valve. There is no need to remove the carrying handle, which acts as additional protection for the can if CalCheck is dropped, as there will be enough clearance to withdraw and replace a gas can. First check that the standard calibrated leak assembly is properly fitted and the gas can is not held (pressed) down as excessive or unexpected venting will occur during changeover. Press the adjust button to relieve CalCheck s dial pressure. With the CalCheck dial safely in the red on the dial, unscrew the gas can. Remove the plastic storage cap form the new gas can and check that the spigot is in place. Hand screw the can into the CalCheck base. Depress the gas can in order to flush the new gas through the internal volume to the calibrated leak, press the adjust button to flush the venting lines. If CalCheck has been recently used with a different gas type allow an extra half minute for the new gas type to leak through the test port, to avoid the possibility that the gas mixture delivered is altered or incorrect. Changing standard calibrated leaks is simple. For safety reasons it is recommended to remove the gas can first. Then lay CalCheck down to show the standard calibrated leak assembly in the bottom of the base. Unscrew and remove the leak assembly including the test port, leaving a hole where the test port was. Unscrew the standard calibrated leak from the test port and replace it with the new certified calibrated leak. Then screw the assembly back into the CalCheck base through the hole. If the old standard calibrated leak was faulty or in need of re-calibration pack it in its box and return it to Ion Science for traceable recertification. Refer to troubleshooting for further details. Page 8 of 12

Troubleshooting Most CalCheck problems are field fixable and tools are not necessary. When changing gas canisters or calibrated leaks tools are unnecessary and should only be tightened with fingers. Use the FAULT & ACTION matrix below for feasible adjustments, otherwise return complete CalCheck to your supplier or to Ion Science representative offices. FAULT/SYMPTOM ACTION Dial stays in red when gas can pushed down Check gas can is screwed in finger tight but not too tightly. When it is correct, a slight unscrewing action vents the gauge after the can has been pushed down. Check the leak assembly is screwed in finger tight but not too tightly. When it is correct, a slight unscrewing action vents the gauge after the can has been pushed. Gas can is empty and needs replacement. Follow procedure with approved spares. Spigot is missing from the gas canister, fit spigot or return to supplier. Dial stays up at high pressure when adjust button is pushed down The gas can has not released after being pushed down so that it s valve is open. Ease the gas can slightly upwards with fingers and repeat the adjust button push. The vent line is blocked. Inspect the nylon tube underneath the CalCheck. Removal vents gas nearer the instrument, so only alter this if the tube can be re-fixed. Dial collapses rapidly without the adjust button being depressed Check that the correct 'O' ring is presesnt behind the standard calibrated leak. CalCheck carrying handle is loose Re-tighten the grub screws at the back of the CalCheck base with an Allen key. Do not remove the carry handle as this provides a gas can with drop protection. Standard calibrated leak is blocked Replace with another traceably certified standard calibrated leak using just finger tightness only. Return the old SCL in it s box to factory. Page 9 of 12

Spares Description Gas canister 2% Hydrogen (for CalCheck Hydrogen) Gas canister 100% Helium Gas canister 0.1% SF6 Gas canister 1% SF6 Gas canister 5% R134a Part No 5/BA-03 5/BA-09 5/BA-10 5/BA-11 5/BA-12 Other gases on request Standard calibrated leak with traceable calibration certificate A-21045 Complete Cal Check package (specify gas) A-21500 Complete CalCheck Hydrosteel package A-21500/H Re-calibration of calibrated leak or replacement CALSCL NB When placing an order please specify leak rate in ml/sec, ml/min or ml/hr; the inlet pressure in mb, bar or psig and gas eg Helium. Page 10 of 12

Technical specification Construction Stainless steel and alloys with ancillary components Gases available Helium, Hydrogen, Isobutylene, SF6, R134a, R22, R1301, R600a, and any other non-corrosive gas. Leak rates available As low as 5 g/yr for refrigerants, or 5 x 10-4 mm/sec 100% helium depending on the gas concentration used. Calibration Each standard calibrated leak is supplied with a traceable certificate valid for 12 months. Ion Science advises that each standard leak is returned for calibration every 12 months. Extras Additional gas/leak kits can be purchased and used with the same base assembly. Weight & dimensions CalCheck base with handle 1.45 kg 340 x 95 x 135 mm Gas can with protective cap <0.25 kg 260 x 80 mm Standard calibrated leak in box 0.12 kg 45 x 145 x 110 mm Packed in case 2.4 kg 450 x 190 x 140 mm Page 11 of 12

Service At Ion Science we recommend that all of our gas detection instruments be returned for service and factory calibration once every 12 months to ensure effective on-going operation. The CalCheck instrument does not need to be returned, but the calibrated leak must be sent direct to Ion Science for calibration. Contact Ion Science or your local distributor for further information. Find your local distributor by visiting: Page 12 of 12