Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Similar documents
Instructions Manual. Variable Area Flow Meter SC-250. Series

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Level switches Series LD Vibrating fork level switch for liquids and solids

Glass tube flowmeters Series 2000

Level switches Series LD Vibrating fork level switch for liquids and solids

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Measurement of Low GAS & Liquid Flows

GA24 Technical Datasheet

Torque Tube TB300 Digital Transmitters

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Magnetic level switch type MR783 Instruction Manual

Ultrasonic level transmitter and indicator

C-Flow Coriolis Mass Flow Meters

SITRANS P measuring instruments for pressure

Orifice Plate Flow Meter

OFFICINE OROBICHE S.p.A. 1/9

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Level transmitter LT 100

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

GEMS SENSORS & CONTROLS

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Flow controller Type ED/CCB311 Instruction manual

Technical Data. Dimensions

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Instruction Manual Contact Pressure Vacuum Gauge

Technical Data. General specifications. Rated operating distance s n 5 mm

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Liquid level instruments BM 24 /BM 51

Monitoring device NTS 30

Pressure Measurement Single-range transmitters for general applications

OPTIBAR P 1010 C Technical Datasheet

Pressure Switches Application Guideline

Operating Manual VSA100A. tina29e1 ( )

INSTALLATION & MAINTENANCE INSTRUCTIONS

Dual Solenoid Gas Valve Installation

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

RMG Meßtechnik GmbH. Publication No E

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

VG5 Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. Dimensions

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Integral type Differential pressure flowmeter VNT Series

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

Installation and Operation Manual

Technical Data. Dimensions

WATER METERS.

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

High-performance submersible pressure transmitter For level measurement Model LH-20

FPD175 Compact orifice carrier assembly

DK48 - DK800. Quick Start. Variable area flowmeter

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Electronic Turbine Meter TERZ 94

9700 Transmitter Submersible hydrostatic level transmitter

Liquid level switch BM 34

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Coriolis Mass Flow Meter

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

INSTRUCTION MANUAL Pressure Relief Device LPT

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Instruction Manual Differential Pressure Transmitter

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Pressure relief valve

GI Series Diaphragm Pressure Gauge Guard

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

G92 Series BASOTROL Automatic Pilot Gas Valve

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Variable Area Flow Meters

T EK-COR 1100A Coriolis Mass Flowmeter

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Technical Data. General specifications. Rated operating distance s n 2 mm

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Temperature gauge Installation Guide

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Technical Data. Dimensions

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Bourdon tube pressure gauge for diaphragm seals

OPERATION MANUAL PNEUMATIC VALVES

Flowmeter. Original operating manual DFM

Materials : Stainless steel ASTM A351 CF8M

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

Transcription:

Target disk flowmeter Series DP Instructions manual DP65 DP500 R-MI-DP Rev.: 4 English version

PREFACE Thank you for choosing the flowmeter series DP from Tecfluid S.A. This instruction manual allows the installation and operation of the target disk flowmeter series DP. It is recommended to read it before using the equipment. WARNINGS This document shall not be copied or disclosed in whole or in any part by any means, without the written permission of Tecfluid S.A. Tecfluid S.A. reserves the right to make changes as deemed necessary at any time and without notice, in order to improve the quality and safety, with no obligation to update this manual. Make sure this manual goes to the end user. Keep this manual in a place where you can find it when you need it. In case of loss, ask for a new manual or download it directly from our website www.tecfluid.com Downloads section. Any deviation from the procedures described in this instruction manual, may cause user safety risks, damage of the unit or cause errors in the equipment performance. Do not modify the equipment without permission. Tecfluid S.A. is not responsible for any problems caused by a change not allowed. If you need to modify the equipment for any reason, please contact us in advance. 2

TABLE OF CONTENTS 1 WORKING PRINCIPLE... 4 2 RECEPTION... 4 2.1 Unpacking... 4 2.2 Storage temperature... 4 3 HANDLING... 4 4 INSTALLATION... 5 4.1 Straight pipe run... 5 4.2 Gaskets... 5 4.3 Internal diameter... 5 4.4 Flow direction... 6 5 MAINTENANCE... 7 5.1 Of the indicator housing... 7 5.2 Of the metering body... 8 6 CLEANING... 8 7 TECHNICAL CHARACTERISTICS... 8 8 DIMENSIONS... 10 3

1 WORKING PRINCIPLE A target disk flowmeter is based on the indirect measurement of the force which is exerted on a disk suspended in the trajectory where a fluid flows at a certain speed. The disk is held by a shaft which is perpendicular to the fluid direction, so that the force applied by it affects the shaft rotation. At the same time, a spring attached to the shaft is opposed to its turn. When the force applied on the spring is equal to the force exerted by the fluid, an equilibrium point of the turn angle of the disk, which is equivalent to a flow rate, is achieved. The flow reading is made by means of magnetic coupling with the housing indication system, thus avoiding fluid leakage to it. 2 RECEPTION The target flowmeters Series DP are supplied already calibrated, ready to be mounted and put into operation. The meters are conveniently packaged for transportation together with their instruction manual for installation and operation. The target disk securing elements used for transport should be removed before mounting 2.1 Unpacking Unpack the instrument carefully, removing any remains of the packing from the inside of the sensor. The target disk must be checked manually to see if the spring shows an even resistance and that the indicator needle moves freely over the graduated scale and returns to 0. 2.2 Storage temperatures -20ºC... +60ºC 3 HANDLING It should always be done with care and without knocks. 4

4 INSTALLATION For the model DP65, until DN300, the installation is between flanges (wafer). the model DP500, from DN250 to DN500 includes flanges. 4.1 Straight pipe run The minimum requirement of straight pipe, free of disturbing elements before and after the flowmeter must be kept. For liquids these distances are equivalent to 3 times the DN and for gases 8 times the DN. 4.2 Gaskets The gaskets should be suitable for the product and they must be carefully centered. It is recommended that the gaskets have an internal diameter of about 5 to 10 mm bigger than the nominal flowmeter diameter. This will avoid reducing the free area when tightening the flange screws, squeezing the seal. Any non-suitable gasket can cause reading errors or interfere with the target disk movement. 4.3 Internal diameter The internal diameter of the pipe and the flowmeter should match. Otherwise, deviations in the flow measurement may occur. 5

4.4 Flow direction The flow direction should be the same as indicated on the scale plate. The following four flow directions are available: ED DAB DES BD Mounting positions or flow directions different from those indicated on the scale plate can cause important reading errors or there will be no reading if the flow direction is in the opposite direction. 6

5 MAINTENANCE 5.1 Of the indicator housing In order to open the housing, remove the four Allen screws M5 (1) and the plastic washers (2), at the back of the indicator housing. If operating anomalies are detected on meter reception, the following points should be checked: a) The indicator needle (4) is rubbing on the scale plate (3). This normally happens if the meter is hit or dropped. Simply straighten it out by bending it slightly until it is separated by between 2 to 3 mm from the scale plate surface (3). b) The indicator needle (4) does not point 0 on the scale. Place the flowmeter on a non-magnetic surface in its normal working position. If when the target disk is moved the needle moves but does not return to 0, check that the bushing (6) is well fixed to the shaft (5). If this is not so, proceed to fix the bushing (6) to the conical end of the shaft using a careful and gentle blow. Then match the indicating needle with the zero of the scale using the indicating needle s adjusting front screw (7), turning left or right as required. Attention, hold the shaft (5) so that it can not be bent or damaged. Check that there is no contact between the mobile system of the needle and connecting cables for limit switches or transmitters. Close the housing with the four washers and screws. 7

5.2 Of the metering body The following faults may be appear: Magnetic coupling deterioration, Deterioration of the torsion or reading spring, Wearing out of torsion shaft bearings, Wearing out or deterioration of the lever and target disk. If any of these breakdowns occurs, it is preferable to repair it in TECFLUID S.A. workshops, as a new calibration will be normally necessary. 6 CLEANING In line Pass the normal cleaning agent through the installation. In the workshop It should be done with soft brushes. Never use sharp objects or metal brushes. 7 TECHNICAL CHARACTERISTICS Accuracy: DP65: ± 2.5% full scale DP500: ± 4% full scale Rangeability: 10:1 Scale length: ~100 mm. Scales: Direct according to fluid to be measured or in %. Operation: Vertical with upwards flow (BD) Vertical with downwards flow (DAB) Horizontal with right to left flow (DES) Horizontal with left to right flow (ED) Connections: DP65 Between flanges. DP500 EN 1092-1, ANSI, JIS flanges. Other flange standards on request. Materials: Body: Plastic coated steel, EN 1.4404 (AISI 316L) Indicator housing: IP65 in coated aluminium (standard) EN 1.4404, PP, others on demand Working pressure: PN40 DN40 DN80 PN16 DN100 DN300 PN10 DN250 DN500 (DP500) Other pressure ratings available on request. Process temperature: - Body in plastic coated steel: -20ºC +130ºC. - Body in EN 1.4404 (AISI 316L), PTFE bearings: -20ºC +150ºC. - Body in EN 1.4404 (AISI 316L): bronze bearings: -20ºC +300ºC. 8

Mounting length: DP65: 65 mm DN40 DN300 DP500: 500 mm DN250 DN300 600 mm DN350 DN400 700 mm DN500 Optional limit switches in the indicator housing: DP-AMM 1 or 2 micro-switches with potential free contacts Maximum current: 3A Máximum voltage: 250 VAC DP-AMD 1 or 2 slot inductive sensors, acording to EN60947 5-6 (NAMUR) Power supply: 8.2 VDC Optional transmitters: TH5 Position transducer, with analog output. 2-wire connection. Power supply: 12... 36 VDC Output signal: 4-20 ma TH5T Position transducer, with totalizer and analog output. 2-wire connection. Power supply: 12... 36 VDC Output signal: 4-20 ma TH5H Position transducer, with analog output. 2-wire connection. Power supply: 18... 36 VDC Output signal: 4-20 ma HART protocol TH5TH Position transducer, with totalizer and analog output. 2-wire connection Power supply: 18... 36 VDC Output signal: 4-20 ma HART protocol Conforms with the Pressure Equipment Directive 97/23/EC This equipment is considered as being a pressure accessory and NOT a safety accessory as defined in the 97/23/CE directive, Article 1, paragraph 2.1.3. Conforms with Directive 2006/95/EC (Low Voltage) Conforms with Directive 2004/108/EC (Electromagnetic compatibility) Conforms with Directive 2002/96/EC (Waste electrical and electronic equipment) All the limit switches and transmitters can be optionally supplied for use in potentially explosive atmospheres. ATEX certification II 1 GD Ex ia IIC T4 or T6 9

8 DIMENSIONS Dimensions DP65 (DN40 to DN300) DN g B A Weight (kg) 40 88 28 250 5 50 102 33 250 6 65 122 40 250 7 80 138 50 250 8 100 158 60 250 10 125 188 70 280 12 150 212 78 280 14 200 268 90 320 20 250 320 102 350 29 300 370 115 370 35 Dimensions in mm 10

DN L 40 325 50 325 65 325 80 325 100 325 125 355 150 355 200 395 250 425 300 443 Dimensions DP500 (DN250 to DN500) DN L A B ØD k g b l x n Weight (kg) 250 500 330 90 395 350 320 26 23 x 12 70 300 500 330 115 445 400 370 26 23 x 12 78 350 600 350 124 505 460 430 26 23 x 16 86 400 600 350 142 565 515 482 26 27 x 16 97 500 700 430 160 670 620 585 28 27 x 20 115 Dimensions in mm 11

WARRANTY Tecfluid S.A. guarantees all the products for a period of 24 months from their sale, against all faulty materials, manufacturing or performance. This warranty does not cover failures which might be imputed to misuse, use in an application different to that specified in the order, the result of service or modification carried out by personnel not authorized by Tecfluid S.A., wrong handling or accident. This warranty is limited to cover the replacement or repair of the defective parts which have not damaged due to misuse, being excluded all responsibility due to any other damage or the effects of wear caused by the normal use of the devices. Any consignment of devices for repair must observe a procedure which can be consulted in the website www.tecfluid.com, After-Sales section. All materials sent to our factory must be correctly packaged, clean and completely exempt of any liquid, grease or toxic substances. The devices sent for repair must enclose the corresponding form, which can be filled in via website from the same After-Sales section. Warranty for repaired or replaced components applies 6 months from repair or replacement date. Anyway, the warranty period will last at least until the initial supply warranty period is over. TRANSPORTATION All consignments from the Buyer to the Seller s installations for their credit, repair or replacement must always be done at freight cost paid unless previous agreement. The Seller will not accept any responsibility for possible damages caused on the devices during transportation. Tecfluid S.A. Narcís Monturiol 33 08960 Sant Just Desvern Barcelona Tel: +34 93 372 45 11 Fax: +34 93 473 44 49 tecfluid@tecfluid.com www.tecfluid.com Quality Management System ISO 9001 cer fied by Pressure Equipment Direc ve 97/23/CE cer fied by ATEX European Direc ve 94/9/CE cer fied by HART is a registered trademark of HART Communica on Founda on The technical data described in this manual is subject to modifica on without no fica on if the technical innova ons in the manufacturing processes so require. 12