PERFORM Operating Document

Similar documents
PERFORM Operating Document

Operating Instructions CO2 Incubator symphony 6.5 W

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

NEW: CO2 incubator with sterilizable sensor

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

AUTOVENT 4000 VENTILATOR

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

CSA Sample Draw Aspirator Adapter Operator s Manual

Operation and Maintenance of the EPV200 Portable Ventilator

Propane Conversion Kit Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

STANDARD OPERATING PROCEDURES

Instructions for High Altitude Conversion

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Series Environmental Chambers

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

TECHNICAL DATA CAUTION

Inert Air (N2) Systems Manual

WATER - JACKETED CO 2 INCUBATORS

NGP-250/500 Nitrogen Generator Quick Start Guide

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

RAM 4021-DPX Operation Manual

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Rejuvenation Instructions

Model 4100 Series. Forma Series 3 Water Jacket CO2 Incubator. Visit us online to register your warranty

MEDICAL EQUIPMENT CATALOG

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Customer Responsibilities

300 Held Drive Northampton Pa

MP15 Jockey Pump Controller

CPR MEDICAL DEVICES INC. OPERATING MANUAL

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

STANDARD OPERATING PROCEDURES

STANDARDS FOR COMPRESSED GAS TESTING

Overview. Front Panel: Keypad and Display

USER S INFORMATION MANUAL

CAPITAL CONTROLS SERIES NXT3000

Pressure Automated Calibration Equipment

CO2 incubator with additional process controls

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

/2004 US/CA

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

UNIVERSITY OF ROCHESTER MEDICAL CENTER

Pressure Regulators. Operating Instructions. Instrumentation

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

ACV-10 Automatic Control Valve

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

CO2 incubator with additional process controls

Water jacket CO Incubators 3503/3517/3524

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

RD(H)20/25 Pressure-Reducing Regulator User Manual

CO2 incubator with additional process controls

Oxygen Concentrator Instruction

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

CO2 INCUBATOR CO2 INCUBATORS

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

The 527 Series Automatic Switchover System with Inlet Pressure Transducers

Technical Information

INSTRUMENT INSTRUMENT YL INSTRUMENT

COSMO INSTRUMENTS CO., LTD.

The 527 Series Automatic Switchover System

RAM Operation Manual

CO2 incubator with additional process controls

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

STERILIZABLE DISSOLVED OXYGEN SENSORS

MF2M Monnier Miniature Compressed Air Filter

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

NTF-515. Operation Manual

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

SIP Fermentation System. (Pilot Scale) 10L / 30L / 50L System. Motor Manual or automatic control of constant agitation speed

OPERATION MANUAL ID900

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

TSS21 Sealed Thermostatic Steam Tracer Trap

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

SILENTAIRE TECHNOLOGY

PTG100 Precision Test Gauge

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Power Valve: Precision Regulator. High precision, large capacity relief regulator

NTF-230 OPERATION MANUAL

Transcription:

PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v02 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16 Summary The content of this PERFORM Operating Document (POD) provides guidelines for the use and maintenance of the CO 2 incubator. PC-POD-CA-007-v02 Printed copies are not controlled. Page 1 of 7

Table of Contents SUMMARY... 1 1. DEFINITION OF TERMS AND ABBREVIATIONS... 3 2. INTRODUCTION... 3 2.1 Overview of CO2 Incubator... 3 2.2 Training requirements... 4 2.3 General precautions... 4 2.4 Relevant documents... 4 3. PROCEDURE... 4 3.1 Control Panel Operation... 4 3. 2 Filling Humidity Pan... 5 3. 3 Filling Water Jacket... 5 3.4 Preventive maintenance... 5 3.4.1 Cleaning Humidity Pan... 5 3.4.2 Cleaning Cabinet Exterior... 6 3.4.3 Cleaning the Interior... 6 3.4.4 HEPA Filter maintenance... 6 3.4.5 Replacing Air Sample Filter... 6 3.4.6 Replacing Access Port Filter... 6 3.4.7. Draining the Water Jacket... 6 4. GAS CHANGEOVER SYSTEM... 7 4.1 Basic operation... 7 4.2 Gas Cylinder/Tank replacement... 7 APPENDIX I: POD Training Record Form PC-POD-CA-007-v02 Printed copies are not controlled. Page 2 of 7

1. Definition of Terms and abbreviations PERFORM operating document (POD) CO2 O2 IR DI Operating documents that are specific to an instrument or technique that require approval by area managers. Carbon dioxide Oxygen Infrared Distilled water 2. Introduction Thermo Scientific Forma Series II Water-Jacketed 3120 CO 2 Incubators combine precise CO 2 control with an IR sensor. These Thermo Scientific Forma incubators feature precise CO 2 control, unsurpassed temperature stability, and superior parameter recovery characteristics, with innovative continuous contamination control technology. 2.1 Overview of CO 2 Incubator Performance Certified in-chamber HEPA air filtration system maintains Class 100 air quality Enviro-Scan microprocessor control Set points and calibration: Temperature, over temperature, CO 2, O 2 Audio/visual alarms with alarm silence Configure Audible On/Off, Access Code, HEPA Filter Change Reminder, RS-485 Interface, Automatic Tank Selector, Audible/Visual Alarms, Display Temp/RH (selectable), Display CO 2 /O 2 (selectable) Construction Durable triple-wall cabinet construction ensures optimal temperature uniformity Exclusive, heated dual pane inner glass door minimizes condensation, enables faster temperature recovery CFC-free foam insulated outer door (field-reversible) Magnetic outer door gasket Accessory outlet Alarm contacts PC-POD-CA-007-v02 Printed copies are not controlled. Page 3 of 7

2.2 Training requirements Prior to using the incubator individuals should: Read and sign this POD. Undergo appropriate incubator training and/or provide a proof of an external training to the clinical analysis supervisor prior to use. 2.3 General precautions The incubator must be installed in a well-ventilated area. The changeover system is connected with two CO 2 tanks for constant supply of CO 2. Make sure both tanks are open. Change the direction of the arrow towards the CO 2 tank in use. The pressure settings on the regulator should be less than 15 psig +/- 5 psig. Do not change the settings on the changeover system. The CO2 gas should have a purity of 99.5% (industrial grade). Gaz cylinder have UN1013 labeled and should be secured to the wall. If higher purity CO 2 is desires inside the incubator, the pressure regulator should be constructed wih a stainless steel diaphragm along with specifying the purity of the CO 2 from the gas supplier. The calibration is performed automatically using an Auto Zero system. Auto Zero occurs every 24 hours. If during the Auto Zero cycle, a CO 2 correction of more than 0.45% is detected, the IR AUTOZ ERR alarm will occur. Refer to user manual for possible problems and inform Clinical Analysis Supervisor. Protective equipment and clothes and other safety instructions should be used at all times. Verify the temperature and CO 2 concentration before use. Verify the water level in the humidity pan inside the incubator. Do not overload the incubator and leave enough space between the items for proper airflow. Gas other than CO 2 or N 2 should not be connected to this equipment. 2.4 Relevant documents Model 3100 series Forma II Water Jacket CO 2 Incubator Operating and Maintenance Manual 3. Procedure 3. 1 Control Panel Operation There are 4 basic modes which allow incubator set up. The modes are as follows: Run, Set points, Calibration and System Configuration. Run is the default mode that the incubator will normally be in during operations. Set is used to enter system set points for incubator operation. PC-POD-CA-007-v02 Printed copies are not controlled. Page 4 of 7

Cal is used to calibrate various system parameters to the customer s satisfaction (temperature, CO 2 system and sensor, relative humidity) Config is the system configuration mode that allows for custom set up of various options (HEPA filter replace reminder, temperature alarm limit, gas limit, water level) Scroll for various parameter keys. The right arrow goes to the next parameter, the left arrow returns to the previous parameter. For the operation details contact Clinical Analysis Supervisor or delegate. Refer to user manual for specific operation procedure. 3. 2 Filling Humidity Pan For best operation, sterilized, distilled, demineralized or deionized water should be used in the humidity pan. Fill the humidity pan to within ½ inch of the top with sterile, distilled water. Place the pan directly on the incubator floor to ensure optimum humidity and temperature response. Check the level and change the water frequently to avoid contamination. Do not allow the water level to fluctuate significantly. Dry-outs will have an adverse effect on the humidity level as well as CO 2 calibration. 3. 3 Filling Water Jacket Water jacket has been filled with DI water (43.5 Liters) at the time of installation. The rust inhibitor is added to the water inside the unit at the time of shipping. The rust inhibitor must be replenished every two years. Refer to user manual for complete instructions. 3.4 Preventive maintenance 3.4.1 Cleaning Humidity Pan Clean the humidity pan with soap and water and a general use laboratory disinfectant (Ex. mild detergent). Rinse with distilled water and spray with 70% alcohol. The pan may be autoclaved. PC-POD-CA-007-v02 Printed copies are not controlled. Page 5 of 7

. 3.4.2 Cleaning Cabinet Exterior Clean the incubator exterior with a damp sponge or soft cloth and mild detergent dissolved in water. Dry with a soft cloth. 3.4.3 Cleaning the Interior Disconnect the power cord connector before cleaning. Use an appropriate disinfectant. Do not use bleach to clean as it may cause pitting and rusting. Remove the shelves. All surfaces must be thoroughly cleaned, rinsed and rough-dried. Use 70% alcohol in a wellventilated area that is free from open flame. Allow the alcohol to fully dry before running power on. Refer to section 5 of the user manual for detailed procedure. Clean door gasket with a mild detergent, water and a soft cloth or sponge. The gasket should be clean and smooth. 3.4.4 HEPA Filter maintenance Replace the HEPA filter when the REPLACE HEPA reminder is displayed. It can be set to alarm after a specified time from 1 to 12 months or more. Refer to user manual for detailed procedure. 3.4.5 Replacing Air Sample Filter The air sample filter should be replaced whenever the HEPA filter is replaced. Refer to user manual for detailed procedure. 3.4.6 Replacing Access Port Filter The access port filter should be replaced whenever the HEPA filter is replaced. Refer to user manual for detailed procedure. 3.4.7. Draining the Water Jacket Turn off the unit and remove the plug from the power source. Remove the front cover plate below the door. Refer to user manual for detailed procedure. To fill the Jacket always use distilled water and add rust inhibitor to the water when filling. PC-POD-CA-007-v02 Printed copies are not controlled. Page 6 of 7

4. Gas Changeover System The changeover system is designed to provide continuous gas flow for applications requiring stored gas supplies. This combines a changeover regulator, three gauges, bracket and a line regulator. 4.1 Basic operation When the primary supplies to the changeover system (supply A) are consumed, the secondary supply (supply B) feeds the line regulator. By turning the changeover regulator hand knob counterclockwise 180, supply A can then be replenished. When Supply B is depleted, supply A will then began to feed the line regulator. Diagram showing the set-up of changeover system In service Supply A 180 Supply B Inspect the regulator, valve and accessories for physical damage and contamination. Do not connect the device if you detect oil, grease or damaged parts. Do not operate a gas handling system under any circumstances if it is leaking or otherwise malfunctioning. Do not attempt to fix any leaks while the line is pressured. Damage to equipment and/or personal injury may result. 4.2 Gas Cylinder/Tank replacement Close the shutoff valve for the side of the exhausted cylinder. On that side close all the cylinder valves. Disconnect exhausted cylinder and replace with a full cylinder. Close vent valve if equipped and open the cylinder valve. PC-POD-CA-007-v02 Printed copies are not controlled. Page 7 of 7

APPENDIX I POD Training Record Form PC-POD-CA-007-v02 Printed copies are not controlled. APPENDIX 1

POD Title Use and Maintenance of CO2 Incubator Ownership Document type Area SOP Number Version PC POD CA 007 V02 Training Record Full Name Institution/PI Contact (e-mail or phone number) Signature Sign here Date