OWNER S TECHNICAL MANUAL

Similar documents
AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Model 420-HY Pressure Regulating Hydrant Valve

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Unit 24: Applications of Pneumatics and Hydraulics

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

OPERATOR S MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

WW-730. Pressure Sustaining/Relief Control Valve

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Bermad Model:

Operating Instructions Model and Hydrostatic Test Pump

WW-720. Pressure Reducing Control Valve

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

2 I All-Flo Pump Co.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

3:1 High Ratio Oil Pump W. Extn. Kit

AIR OPERATED DOUBLE DIAPHRAGM PUMP

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic Series Inc. Lube Free Models. II 2 GD c.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

AIR STAPLER MODEL: CSG1C Part No

WW-720. Pressure Reducing Control Valve

TECHNICAL DATA. than the water inlet pressure to the concentrate

4 ANGLE GRINDER MODEL NO: CAT 52 PART

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

2 I All-Flo Pump Co.

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

B50 & X50 AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic B5002 B5005 Series Lube Free. II 2 GD c. Table of Contents

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

Operation Manual Air Saver Unit ASV5000 Series

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Operating Instructions Models and Hydrostatic Test Pumps

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Operating Instructions Models and Hydrostatic Test Pumps

Pneumatic Powered - Plunger Pumps

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Installation, Operation, and Maintenance Manual

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Hydraulic Punch Drivers

Model: 43T. Bermad Pressure Relief Valve

Code AWC20HP Air Compressor

OPERATING & MAINTENANCE INSTRUCTIONS

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

Product Sheet Spraymist Unit

Technical Data Sheet TI-F50 Locking Units series KFH

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

SERVICE & OPERATING MANUAL

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Precision Regulator. Series Model Regulating pressure range Port size Page

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

Suggested Installation & Operating Instructions for Sidewinder Pumps

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Operating Instructions Models and Hydrostatic Test Pumps

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Series IRV1000/2000/3000

DynaPak 2000L System Support Manual Version

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Pure Water Power Purification System 4-Stage RODI Operations Manual

Operating Instructions Models and Hydrostatic Test Pumps

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HIGH PRESSURE DRILLING FLUID PUMP

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Freedom8 ShoeBox Compressor Manual

BACK PRESSURE / SUSTAINING

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Pilot Check Valve: Metal Body Type

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Diaphragm Failures: Failure types and what they tell you.

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Booster Regulator/Air Tank

Easy Nest Kits. Installation Suggestions

Hydraulic Reliability & Preventive Maintenance Report

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Transcription:

EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids, industrial sludge and liquids containing a relatively high amount of grit and solid content. Manufactured with an aluminium body, UPE diaphragm and teflon ball valve, the DP7002 being a positive displacement pump is efficient and extremely reliable. Requiring no ongoing precision adjustments after installation and with no close fittings to be monitored, the DP7002 1 air operated diaphragm pump with its very simple operating principle is easily and inexpensively maintained. Specifications Liquid input method Temperature Range Max Flow Rate Air Pressure Range Max. Solid Diameter Noise level Atmospheric pressure or additional pressure + C ~ +60 C 180 L/min 1.0~8.3 kgf/cm² (Bar); 120psi 2.~3 mm < 80dB Disassembly of Pump 1. Check Ball Valves : For best priming and most efficient pumping performance, it is important to maintain check valves and valve seats in good condition for proper sealing. The inspection of valves is usually reduced performance caused or cycling without pumping for inspection and replacement of valves, remove the eight hexagon nuts before fixing the device and then change ball valves and valve seats. 2. Rubber Diaphragm : Do inspection and replacement of rubber diaphragm as long as air is discharged from liquid or through air exhaust port. Inspect to see whether the screws of manifold secure the chamber to the manifold assembly correctly or not. At disassembly, remove rubber diaphragm by turning a hexagon screw head fixed on transmission shaft with spanner then hold the transmission shaft in a clamping device from the other side, but make sure to protect the surface of transmission shaft so as not to scratch or mar it in any way. 3. Thimble Valve : To inspect thimble valve that it is frayed or not, do remove (P.4 3) 4 hexagons and use pliers to take it to inspect or change a new one. 4. Air valve: The function of this valve is to lead the operation of air valve. And it can be disassembled after removing the air valves body from the pump.

Fluid Outlet<1"> Air Inlet<3/8"> 348.0 281.0 164 117.0 204 260 Fluid Inlet<1"> 170 228 Install Indication Always connect the liquid outlet hose first, then connect the pump to air pressure source. The unit is pressurized internally with air pressure during operation. So always disconnect air pressure supply before disassembling. Maintenance After Use ATTENTION: before disassemble and maintain the pump, be sure that there isn t any pressure inside the machine body. This procedure is important to insure complete draining in freezing weather. 1. In order to prevent the materials from hardening during idle periods, these materials should be flushed from the pump. Always keep the pump interior and the pipe filter in clean status. Don t leave the liquid fuel in the pipe for a long time to avoid flow jam. 2. To change the liquid fuel, raise the inlet fuel pipe, open the fuel circulation switch and wait until the liquid fuel inside the machine body to come out fully. Put the pipe head into the cleanse solvent tank (solvent about 10L) to absorb solvent. Once the interior is fully cleaned, put the inlet fuel pipe head into the prepared liquid fuel tank to absorb the liquid fuel. Close the fuel circulation switch to continue operation. 3. To use with the outlet fuel adjuster, the inlet gas pressure must be higher than the outlet fuel pressure. The adjuster should be adjusted according to the fuel s concentration and outlet quantity. 4. Circulation fuel switch shall be open only when cleaning the pump or changing the fuel. It should not be open at normal operation. Installation 1. Install and use it respectively as much possible. 2. Reduce the service capacity of piping accessories. 3. Keep the prescribed bore of suction pipe. 4. If fitting up a Rigid piping, it should be assembled with a short flexible hose.. While installation, note the packing piece to see whether there is leakage or not. 6. While installing pipe, be sure that suction pipe and air pipe should contain clearly. 7. Inlet pipe must install filter to prevent that big solid entering in to result breakdown. Operation 1. The operation altitude for priming is below 20 feet (6.09 meters). If deliver high viscosity liquid, the distance between suction inlet and liquid surface should be diminished. 2. The output flow can be controlled by air switch. 3. To star or stop the pump can be controlled by the discharge controller. 2

Air Supply 1. Do not connect the unit to air supply in excess of 8. kgf/cm². 2. Do use the prescribed compressed air pressure. 3. The air inlet can t be smaller than the air inlet valve, otherwise, the air pressure might be insufficient and work volume will be influence. 4. It is better for air supply pipe to install air filter and surge suppressor. Air Exhaust 1. This equipment can be submerged if the exhaust pipe is above the liquid level. 2. Piping used for the exhaust should not be smaller than the 1 (2.4cm) pipe size. Reduced pipe size can restrict the exhaust air and cause reduced pump performance. 3. When the material being pumped is a hazardous or toxic material, the exhaust should be piped to an appropriate area for safe disposition. 4. When the material being pumped is at a level above the pump, the exhaust should be piped to a higher level than I/O equipments. Importance This unit is pressurised internally with air pressure during operation. So always disconnect air pressure supply before disassembling. Trouble Shooting Trouble Pump can run but not have suction or have improper suction Pump can t drive Possible Causes 1. Throttle or leak caused by rupture in piping before suction inlet of pump. 2. Front side of suction pipe not having strainer net and abstracting bigger solid to choke between valve and valve seat. 3. Diaphragm rupture. 4. Pipe throttled after outlet from pump.. Improper running of sequence valve. 6. Failure of check valve or valve seat. 7. Suction line of pump too long or too high from liquid level beyond of suction range of pump. 8. Outlet pipe too far or too high. Beyond and exceeding pump pressure. 9. Air pressure or air flow insufficient that can t generate normal suction. 10. Outlet liquid intermittent gravely due to diaphragm ruptured or check valve choked by solid. 11. Muffler spurting mortar due to diaphragm ruptured or anchor plate of diaphragm loosened. 12. Pump can t run or have improper. Suction caused by idle period too long or mortar inside hardening. 1. Plugged in piping after outlet from pump. 2. Mortar precipitating and hardening. 3. Diaphragm ruptured. 4. Failure of Actuator.. Switch of pilot valve ruined. 6. Sequence Valve not moving due to improper lubrication. 7. Sequence not moving due to freeze caused by excessive low temperature. 8. Air pressure too small or air quantity insufficient. 9. It can t move due to the hard solid abstracted with top against diaphragm. 10. Air hold of pilot valve blocked or O-ring failed. 11. Muffler not exhausting air, caused by throttle. 12. Air supply polluted. If not cleaning it after piped, sequence valve will be polluted and can t move. 3

Parts And Drawing Breakdown DP7002 8 6 10 7 4 9 9 43 42 46 3 40 4 29 31 44 0 32 33 47 2 6 41 36 43 42 39 38 37 3 22 13 17 16 4 1* 7 34 2 14 26 2 30 28 24 1 23 27 20 19 46 21 18 13 12 11 1 3 47 "*"Some model don't include this parts. 20120101 4

Parts And Drawing Breakdown DP7002 Ordering Spare Parts Parts List Part No. DP7002 Item Description Qty Item Description Qty DP7002-1 Hexagon Screw 16 DP7002-28 O Ring 3 DP7002-2 O Ring 2 DP7002-29 O Ring 1 DP7002-3 Hexagon Screw 8 DP7002-30 Thimble 1 DP7002-4 Down Ball Seat 2 DP7002-31 Thimble Cap 1 DP7002- O Ring 4 DP7002-32 Hexagon Screw 4 DP7002-6 Up Ball Seat 2 DP7002-33 Abnormal O Ring 1 DP7002-7 Up Ball Cover 2 DP7002-34 Abnormal O Ring 1 DP7002-8 Down Ball Cover 2 DP7002-3 Body Of Sequential 1 DP7002-9 Ball 4 DP7002-36 Piston Of Air Valve 1 DP7002-10 Teflon Pad 2 DP7002-37 U-Type O Ring 1 DP7002-11 Housing Of Pump 2 DP7002-38 U-Type O Ring 2 DP7002-12 Steel Hexagon Screw 2 DP7002-39 Starting Copper Latch 2 DP7002-13 Steel Washer 2 DP7002-40 Cover Of Sequential 1 DP7002-14 Pad Of Diaphragm 2 DP7002-41 Cover Of Sequential 1 DP7002-1 Outside Diaphragm (PE) 2 DP7002-42 O Ring 2 - Outside Diaphragm (Teflon) 2 DP7002-43 Housing Of Sequential 2 DP7002-16 Inside Diaphragm 2 DP7002-44 Body Of Cylinder Base 1 - Diaphragm 2 DP7002-4 Hexagon Screw 4 DP7002-17 Pad Of Diaphragm 2 DP7002-46 Pipe 2 DP7002-18 O Ring 2 DP7002-47 Hexagon Screw 8 DP7002-19 Shaft Cover 2 DP7002-0 Silencer 1 DP7002-20 O Ring 2 DP7002-1 Air Pressure Room Of Pump 2 DP7002-21 O Ring 2 DP7002-2 Hexagon Bung 6 DP7002-22 Shaft Of Diaphragm 1 DP7002-3 Silthery Mass Valve 1 DP7002-23 Body of Thimble Valve 1 DP7002-4 Include Ply 1 DP7002-24 O Ring 1 DP7002- O Ring 2 DP7002-2 O Ring 1 DP7002-6 O Ring 1 DP7002-26 O Ring 1 DP7002-7 O Ring 1 DP7002-27 O Ring 3