Air Mortar User Manual

Similar documents
Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Operating Instructions Model and Hydrostatic Test Pump

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Regulators. Instructions for Use

WW-720. Pressure Reducing Control Valve

Hydraulic Punch Drivers

Operating Procedure TITON SUBSEA BOLT TENSIONER

WW-720. Pressure Reducing Control Valve

AUTOMATIC GAS MANIFOLDS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

BCV31 DN20 - Blowdown Control Valve

Manual Actuated Boiler Blowdown Valves

30T A/Manual Hydraulic Shop Press

NGP-250/500 Nitrogen Generator Quick Start Guide

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Model PDT Dewpoint Transmitter

CS150 CAP STAPLER OWNER S MANUAL

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Code AWC20HP Air Compressor

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

MoveRoll Conveyor Operating and Maintenance Manual

Copyright, 2005 GPM Hydraulic Consulting, Inc.

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

MANUAL GAS MANIFOLDS

OWNER S TECHNICAL MANUAL

DK ton, Double-acting, Die-type Crimping Tool

BCV31 DN40 - Blowdown Control Valve

Operating Instructions Model and Hydrostatic Test Pump

2 in. 18 Gauge Brad Nailer. User manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

SC6H OIL-LESS AIR COMPRESSOR

Operating Instructions Models and Hydrostatic Test Pumps

K Page 1 of 48 Air Intake - Pg. 17

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

SERVICE MANUAL No. I-0043

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Operation & Service Manual


FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Installation, Operation, and Maintenance Manual

FIRESTORM. Assembly Instructions. Electric Upgrade Kit for the Autococker. Designed & Manufactured by PGI

Dialflow Regulator. Instructions for Use

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Operating Instructions Models and Hydrostatic Test Pumps

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

WW-730. Pressure Sustaining/Relief Control Valve

Model PSI Compressor with 3-Gallon Air Tank 12VDC

DynaPak 2000L System Support Manual Version

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

PDY TON HYDRAULIC CRIMPING TOOL WARNING

35 TON HYDRAULIC PUNCH WARNING

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Operating Manual. --N5021 Wide Crown Stapler--

Pressure Dump Valve Service Kit for Series 2300 Units

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Type CT88 Backpressure Regulator

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Unit 24: Applications of Pneumatics and Hydraulics

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

ATS430 turbidity sensor Retractable insertion assembly

User Information Sheet 013

Budget Range Operators Handbook

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Installation, Operation, and Maintenance Manual

Installation and Service Manual

IP16 HYDRAULIC INTENSIFIER

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Related Products: Auto Drain Valve. Model/Specifications. Model

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR MKIII CONSTANT PRESSURE CYLINDER

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

RhinoPro Cartridge Gun Manual

Pressure Dump Valve Service Kit for Series 3000 Units

Operating Instructions Models and Hydrostatic Test Pumps

24 Litre Air Compressor

JARVIS. Model CPE Hock and Neck Cutter EQUIPMENT... TABLE OF

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Oxygen Dialflow Meter. Instructions for Use

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

SPCH/ Blowing block

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

Instruction Manual Updated 7/26/2011 Ver. 2.2

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Transcription:

Page 1/5 1 Introduction The Air Mortar is a fast-acting pneumatic system, designed to provide a rapid discharge of inert gas when triggered by 12VDC input signal. The standard system vessel has a volume of 17.7 litres but can be supplied in other volumes, it can be operated at any pressure from 40 to 580psi (2.75 to 40bar). 2 Safety Figure 1 Air Mortar and Section through Air Chamber Compressed gas equipment is dangerous when operated incorrectly. This System should only be used by competent persons, operated in accordance with local regulations for air equipment and with appropriate safety assessments. It is essential that the operator fully reads and understands these notes prior to operating the System. Once the System has been charged with Air it should be treated with the same caution as a Pyrotechnic Mortar Pot. The integrated Pressure Relief Valve is set during assembly by the supplier and must be used to prevent the system exceeding its rated pressure. 3 Operation Figure 1 shows the section through the System identifying the direction of operation; the three stages of operation are illustrated in Figure 2. Figure 2 Cross section of the System in three phases of operation - illustrating the Operation Commercial in Confidence Page 1/5

Page 2/5 The System may be operated with a gas such as Nitrogen, CO2 or Air. Exposure to very low temperatures, such as when used with CO2, may cause the piston seal to harden. This may prevent complete sealing until the valve warms up. The System is supplied with a ½ Female Flat Face Quick Release Connector on the Air Inlet side; the User should choose an appropriate Air Supply and Regulator. Dependent on the effect, the Operator may set up a snoot which can be bolted directly to the output flange, an example is shown in Figure 3. The standard bolting pattern on the Output flange is also shown in Figure 3. Figure 3 Output Interface and example of assembled with Snoot The following guidelines should be used when operating the System: 1. Care should be taken to prevent debris or contamination from entering the system past the Main & Trigger Pistons when it is loaded as this may prevent the System from sealing properly or may cause it to jam. Before loading the snoot, the System may be pre-charged with a low pressure (less than 1 bar) which is sufficient to seal the main piston and prevent debris passing into the vessel past the main piston. Only when the snoot is loaded and prepared for the effect should the System be charged to an appropriate pressure; 2. Once charged the System is operated by triggering the Solenoid releasing the Trigger Piston, the Wallbanger is supplied fitted with a 12VDC solenoid valve for this purpose. To operate at different voltages, the solenoid coil can be changed. Even though the System is fitted with one-way valves it is good practice to leave pressure connected to the Input to prevent loss of pressure on the Trigger Piston. If it is necessary to release the pressure from the System without firing, the correct process must be followed to allow for the safe isolation of the System, the method is listed below. The Pressure Gauge, Manual Bleed Tap and Pressure Relief Valve are shown in Figure 6 (Appendix), the User should make themselves familiar with these parts and their operation prior to using the System. 1. Isolate the Air Supply; 2. Manually release the Bleed Tap on the bleed down circuit, allowing air to be bled down from the Vessel. The discharge can be monitored by noting the reducing vessel pressure on the Pressure Gauge and also with the noise generated by the escaping air; 3. The danger area should only be entered once the discharge is complete and the Air Supply isolated. Commercial in Confidence Page 2/5

Page 3/5 The System must be charged to remain within the operating pressure range using the selected Air Supply and Regulator. In the undesired event that the System is set to be charged beyond the maximum operating pressure the Vessel will discharge automatically through the pre-set Pressure Relief Valve. The Pressure Relief Valve is not a control valve and must not be relied upon to regulate the operating pressure. 4 Inspection, Maintenance and Spare Parts This System should only be operated by persons competent in the use of Compressed gas equipment and inspected in accordance with local regulations necessary for Air Equipment. The CE plate, showing the build and test details, must not be removed from the System. At all times it is important to ensure that that the System is discharged and isolated from an Air Supply before any maintenance or servicing. The seals on the Main and Trigger Pistons must be kept clean to ensure the system does not leak and care should be taken to prevent debris or contamination from entering the system. Prior to use it is recommended that the system is charged to a low pressure and checked for air leakage past the pistons. The Main Piston seal can be cleaned without dismantling the System whilst the Piston is in the return position (Stage 3 in Figure 2). To gain access to the Trigger Piston for cleaning the Trigger Plug must be removed. It is important that the Trigger Piston does not leak as when the System is charged with air, any leakage past this piston may trigger the System. If either piston is found to leak following cleaning of the System, they should be replaced by manufacturer original parts (Table 1). The System is designed to be durable when handled and stored in an appropriate manner. The System should always be cleaned and dried after use and stored in a dry environment to ensure water does not condense in the System. If the System suffers from leakage it can be partly dis-assembled and serviced; once dis-assembled the O-rings, Piston Seals and mating faces should be cleaned before being lightly oiled and re-assembled. If any of the parts show signs of damage these should be replaced using the parts identified in Table 1 (shown in the Appendix), these parts can be ordered direct. Table 1 Spare Parts List ITEM QTY DESCRIPTION PART NUMBER 1 1 Exhaust Flange. EH17001D001 2 2 Main Piston and Exhaust Flange O-Rings. Polymax 210x2.5N70 4 1 Main Piston. EH17001D007 5 1 Guide Pin. EH17001D002-1 Guide Pin O-Ring Polymax 19.8 x 2.4N70 6 1 PTFE Coated bush, 20mmID, 23mm OD, 10mm high. DU2010 7 1 Vessel Weldment with Cylinder (EH17001D008). Welded Vessel Assembly 8 1 Weldment of Trigger Exhaust (EH17001D0005) & Trigger Tube (EH17001D004) Trigger Weldment Assembly onto Welded Vessel Assembly. 10 1 Trigger Piston. EH17001D006 11 2 Trigger Piston and Plug O Rings. Polymax 40x2.5N70 12 1 Trigger Plug. EH17001D003 13 1 ¼ m/m (t/p) adaptor, 500mm braided PTFE Hose with ¼ female, ¼ m/m with Custom Hose Wall-Banger kit - 1x ¼ dowty Seal, ¼ 3way Bleed Block, ¼ 40 bar Pressure Relief Valve with Pressure Gauge & Bleed Down Tail ¼ dowty seal. ¼ 0-1000psi Pressure Gauge. 14 1 3/8"x ½" m/m adaptor with ½ and 3/8 dowty seals, 40bar 12VDC Co-Ax Solenoid, ½" x ½" m/m adaptor with 2x ½ dowty seals, ½ 100bar pneumatic Check Valve, ½" m/m adaptor with 2x ½ dowty seals, ½ Flat Face Female Connector. Custom Hose Wall-Banger kit - Air Inlet and Trigger Commercial in Confidence Page 3/5

Page 4/5 15 1 Vessel and Trigger Piston one-way valves VU1120 14X. 5 Further information 5.1 Updates to the User Manual Custom Hose Wall-Banger kit - One Way Valves Prior to operation the User should check the Event Horizon website for any updates to the User Manual and any product changes: http://www.precisionenergetics.co.uk/docs/eh17001r001_user_manual.pdf 5.2 Contact Details For additional information or replacement parts please contact: 1. Event Horizon on +44 (0)1458 210 280; info@precisionenergetics.co.uk; or by post to The Old Brewery, Stagman Lane, Ashcott, Somerset, TA7 9QW. UK. http://www.precisionenergetics.co.uk/ 2. Custom Hose & Fittings on +44 (0)1923 225534; enquiries@customhose.co.uk; or by post Custom Hose, 194 Queens Road, Watford, Hertfordshire, WD17 2NT. UK. http://www.customhose-catalogue.co.uk/ 6 Appendix Figure 4 Section through Wallbanger - Table 1 Parts identified Figure 5 Overview of Wallbanger Commercial in Confidence Page 4/5

Page 5/5 Check valve Flat Face connector Pressure Relief (type may vary) Manual Bleed Tap Figure 6 Detail showing: Flat Face, Check Valve & Pressure Gauge, Pressure Relief Valve and Bleed Tap Commercial in Confidence Page 5/5