Hydraulic Damper (HB) 07/2011

Similar documents
DICTATOR "DIREKT" Gate Closer

DICTATOR "DIREKT" Gate Closer

Splitting cylinder C20

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Wide opening parallel grippers Series CGLN

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Cylinder Controls. Operating information. For ATEX specific products contact Sales Office. 2/2 Blockers. PDE2600PNUK Parker Pneumatic

Technical Data Sheet TI-F50 Locking Units series KFH

Pressure regulator for water

Proportional pressure regulators VPPE

K0709 Quick-fit couplings

Pressure regulators Manually operated Fine setting valves. Brochure

TANDEM plus BLUMOTION 563H/563. installation instructions

Leak-Free Load-Control Valve SAE ½ psi flange

Fixed Displacement Plug-In Motor A2FE

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

PRO1030 Bi-Directional Assembly Replacement

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

09 - Choosing /sizing a cylinder and valve

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

Pressure Dump Valve Service Kit for Series 2300 Units

Bores: ø 10, 16, 20, 25, 32 mm

GENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

Fixed Displacement Motor A4FM

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

Controllers DR, DP, FR and DFR

Leak free Pipe Rupture Valve for Excavators

Pressure Dump Valve Service Kit for Series 3000 Units

Compact Pressure Switch

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Expansion Thermometers Stainless Steel Series, Model 70

Nautique Triton Clamping Board Rack V2

Accessories for Progressive Systems

Chuck Size. Chuck Model. Chuck Dia. 5 N N N N N

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Micro grippers HGPM/HGWM

Operating instruction for the quick-change tap holders type:

Bladder Accumulators High pressure

Model A Sleeve Valve Cement Retainer

Flow control valves Series RFU - RFO 2/

Inverse Proportional Pressure-Relief Cartridge, Size 10

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Direct Operated Precision Regulator Modular Style. Standard Specifications

SECTION 2 RING MOUNT

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Operating manual for the pressure transducer unit CCS 1000

Series MX pressure regulators 3/

Bladder Accumulators Standard model

Installation, operation & maintenance manual - original version

Push-in fittings NPQH

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Technical Information TI-S10 Safety Locks. 2 Function. Contents

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

DI-DRO ADVANCED FORMING SYSTEMS

Pressure relief valve, direct operated

Double Pilot Operated Cartridge Check Valve, Size 8

HEAVY DUTY PNEUMATIC

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Fixed Displacement Motor A4FM

Leak-Free Load-Control Valve, Size 20

SAFETY FIRST. Inspection Proper Set Up Proper Climbing & Use Proper Storage & Carrying Operating Instructions

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

TANDEM plus BLUMOTION 563F installation instructions

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Materials : Stainless steel ASTM A351 CF8M

Pressure Reducing Valve DMV 755

STIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank

WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

Nerf N-Strike Elite Strongarm Spring Piston Chamber Replacement

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

Heavy-duty three-point grippers HGDT

Diaphragm pressure switches, 42 V

[Instruments for vacuum measurement, checking and adjustment] 3

Piloted Non-Return Valves

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Solid Roller stud mount

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

1000/13.02 KOBSERT. Thread inserts for metals

DWR6-205, DWR16-205, DWR6-206 Safety Pressure Limiters

pipe connectors. General description of pipe connectors Development/Design Purpose Versions

Compact pressure switches for gas and air

zkratka označení: PAL* technický list výrobku vytvořeno :13 1/6 pneumatický pohon série RE > tvrdý anodizovaný hliník NBR

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

C 0G 00 N/US

Transcription:

e l b a t adjus Hydraulic Damper (HB)

EL2 = 2x + 40 M5x5 Ø15 Ø6 M5x5 Size 6/15 : (Extension and compression force 20N to 800N) size EL1 V0 V0 A 6 100 240* V0 = Thread V0 = Thread 6 = 6/15 25 90* S2 = S2 = 50 140* B3 = B3 = 75 190* G5 = G5 = 100 240* 350 N R7 = R7 = 340* 300 N J3 = Ball socket J3 = Ball socket S2 Technical advices: * the length of chosen s has to be added EL1 = EL2 + s B3 G5 R7 Ball socket J3 force = 50N. Please indicate in case of an order. EL2 = 2.45 x + 47 Chosen s have to be secured

EL2 = 2x + 50 M8x8 Ø22 Ø8 M8x9 Size 8/22 : (Extension and compression force 30N to 1.800N) B0 N0 A 1 100 250* size EL1 B0 = Thread N0 = Thread 1 = 8/22 50 * 1. 1. S3 = S3 = 100 250* 1. 1. A3 = A3 = 350* 1. 1. C5 = C5 = 200 450* 1.000 N 1. A7 = A7 = 250 550* 1.000 N 1. S3 Technical advices: * the length of chosen connecting parts has to be added EL1 = EL2 + s A3 C5 A7 Ball socket P3 force = 100N. Please indicate in case of an order. EL2 = 2.38 x + 55 Chosen s have to be secured

EL2 = 2x + 60 M8x8 Ø28 Ø10 M8x9 Size 10/28 : (Extension and compression force 30N to 3.000N) H0 N0 A 3 300 660* size EL1 H0 = Thread S3 = A3 = C5 = A7 = N0 = Thread S3 = A3 = C5 = A7 = 3 = 10/28 100 200 250 300 350 400 500 260* 360* 460* 560* 660* 760* 860* 1060* 2.500 N 2.000 N 1.500 N 1.000 N S3 Technical advices: * the length of chosen s has to be added EL1 = EL2 + s A3 C5 A7 Ball socket P3 force = 100N. Please indicate in case of an order. EL2 = 2.35 x + 60 Chosen s have to be secured

EL2 = 2x + 75 MF14x15 Ø40 Ø14 MF14x15 Size 14/40 : (Extension and compression force 30N to 10.000N) Z0 Z0 A B 400 875* size EL1 Z0 = Thread S5 = B4 = L5 = C8 = Z0 = Thread S5 = B4 = L5 = C8 = B = 14/40 100 200 300 400 500 600 700 800 275* 375* 475* 675* 875* 1.075* 1.275* 1.475* 1.675* 8.000 N 6.000 N 4.000 N * the length of chosen s has to be added EL1 = EL2 + s S5 B4 L5 C8 Technische Hinweise: force = 200N. Please indicate in case of an order. EL2 = 2.32 x + 82 Chosen s have to be secured

Hydraulic damper (HB) Technical advices / installation recommendations To consider: The maximum loads and pull direction may not be exceeded. There must be a mechanical limit stop approx. 1-2 mm before end of. Mounting of the dampers is in any position possible. The s should be secured against rotation. Due to constructional reasons, Type has a free travel of approx. 20 % For a function without free travel, Type has to be chosen. Adjustment of the dampers: - An adjustment is only possible in completely inserted or extended position - The force can be adjusted by turning the piston as described below. Thereby, the length EL2 will be extended by max. 6 mm. Please take care during the adjustment that you don't damage the adjustment segment by turning it too strong against the limit stop. In case of considerable resistance, please stop the adjustment. The dampers of Type can be adjusted either in completely inserted or extended position. The dampers of Type can be adjusted in completely extended position. 1. Hold the. 2. Adjust the damper by turning the. In case of adjustment with extended, please pull the slightly during the turning process until the piston locks. In case of adjustment with inserted, the has to be pushed slightly until it locks. Turning to the right: Damping will be increased, speed will be reduced Turning to the left: Damping will be reduced, speed will be increased