HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Similar documents
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

BS Series Basket Strainer

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

Operating Manual. Model BAC-30RT30/BAC-30DC

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

ASDX Series Silicon Pressure Sensors

Accu-Tab Systems 1000 Series by Axiall Corporation

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Accu-Tab Systems 2000 P Series by Axiall Corporation

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

ACCU-MIX 1200 / / 26270

OPERATION AND INSTRUCTION MANUAL

RCD - Ultra-Rugged Differential Pressure Flowmeter

FloWash. Industrial Filter Cart

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Installation, operating and maintenance Instructions for Seemag bypass level indicator

TITAN FLOW CONTROL, INC.

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

Variable Area Flow Meters

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Deep Submersible Level Transducer Series 300DS

KOBOLD KSM FLOWMETER. User Instructions

Accu-Tab PowerBase 3070AT by Axiall Corporation

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

DTG - LCD Digital Temperature Gauge USER MANUAL

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

FLANGED TWO-PIECE BALL VALVES

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Level switches Series LD Vibrating fork level switch for liquids and solids

INSTALLATION AND OPERATION INSTRUCTIONS

AND OPERATION INSTRUCTIONS

J Air and Water Kit Instructions Part# 02584

Nitrogen Supply System

WEATHERIZING INSTRUCTIONS

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

Model Series 63DL Differential Type Flow Controller

T EK-SUB 4800C 19 mm Submersible Level Transmitter

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

THE INSIDE STORY OF THE F-SERIES:

Foreign language versions available online at:

GAS FUEL VALVE FORM AGV5 OM 8-03

Pressure Transmitters 36 F-27839

MODEL NUMBER: P PORTABLE COMPRESSOR

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Installation and Operation Manual Chargeable Dampener Models

D Series Air and Water Kit Part# 02550

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

Level switches Series LD Vibrating fork level switch for liquids and solids

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

CSA Sample Draw Aspirator Adapter Operator s Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

Color/Catalyst Dispense Valves

Installation, Operation & Maintenance Manual

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

DESCRIPTION FEATURES

IMPACT RING BIT SYSTEM Care & Maintenance Instructions

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

PENBERTHY MULTIVIEW MAGNETIC LIQUID LEVEL METERS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

FLANGED TWO-PIECE BALL VALVES

ROPV R40 E Series User Manual

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

SPECIFICATIONS ATTENTION

Model PDT Dewpoint Transmitter

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

ACCU-PULSE Installation and Operation Instructions

SPD310/SPD360 Air Differential

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m)

Introduction INDEX. INTRODUCTION HSE

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

DPC-30 DPC-100. Reference Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

INSTALLATION AND OPERATION INSTRUCTIONS

OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

Transcription:

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TFS SERIES FLOW METERS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY, OR EVEN DEATH. 1. Hayward Flow Control (Hayward), a division of Hayward Industries, guarantees its products against defective material and workmanship only. Hayward assumes no responsibility for property damage or personal injury resulting from improper installation, misapplication, or abuse of any product. 2. Hayward assumes no responsibility for property damage or personal injury resulting from chemical incompatibility between its products and the process fluids to which they are exposed. Determining whether a particular PVC, CPVC, or PP product is suitable for an application is the responsibility of the user. Chemical compatibility charts provided in Hayward literature are based on ambient temperatures of 70 F and are for reference only. 3. Hayward products are designed for use with non-compressible liquids. Hayward PVC and CPVC products should NEVER be used or tested with compressible fluids such as compressed air or nitrogen. Use of PVC and CPVC products in compressible fluid applications may result in product damage, property damage, personal injury, or even death. The Series TFS Flow Meter is intended for use in liquid service only. Do not attempt to use this meter for m e t e r i n g air or gases. Use of this product in air or gas service may result in product damage, property damage, personal injury, or even death. 4. The maximum recommended fluid velocity through any Hayward product is eight feet per second (8 ft/s). Higher fluid velocity can result in damage due to the water hammer effect. 5. Piping systems must be designed and supported to prevent excess mechanical loading on Hayward products due to system misalignment, weight, shock, vibration, and the effects of thermal expansion and contraction. 6. The effect of temperature on plastic piping systems must be considered when the systems are initially designed. The pressure rating of plastic systems must be reduced with increasing temperature. Maximum operating pressure is dependent upon material selection as well as operating temperature. Before installing any Hayward product, consult Hayward product literature for pressure vs. temperature curves to determine any operating pressure or temperature limitations. 7. PVC and CPVC plastic products become brittle below 40 F. Use caution in their installation and operation below this temperature. Hayward PVC and CPVC products should not be used in services with operating temperature below 34 F. 8. Due to differential thermal expansion rates between metal and plastic, transmittal of pipe vibration and pipe loading forces, DIRECT INSTALLATION OF FLOW METERS INTO METAL PIPING SYSTEMS IS NOT RECOMMENDED. Wherever installation of plastic flow meters into metal piping systems is necessary, it is recommended that at least 10 pipe diameters in length of plastic pipe be installed upstream and downstream of the plastic valve to compensate for the factors mentioned above. 9. Published operating requirements are based on testing of new vessels using clean water at 70 F. Vessel performance is affected by many factors including fluid chemistry, viscosity, specific gravity, flow rate, and temperature. These should be considered when sizing Hayward products. 10. Systems should always be depressurized and drained prior to installing or maintaining any Hayward product. Failure to depressurize and drain system prior to installing or maintaining flow meter may result in product damage, property damage, personal injury, or even death. Pg. 1 of 7

PROGRAMMING RELAY SET POINT & TIME DELAY: Pg. 2 of 7

PROGRAMMING RELAY SET POINT WITH HYSTERESIS: ALARM FUNCTION: MODE OF NPN OUTPUT: Pg. 3 of 7

GENERAL TERMS: WIRING DIAGRAM: Pg. 4 of 7

INSTALLATION: Pipe must be filled with the fluid under normal operation. Flow meter can be installed in a horizontal or vertical direction. Minimum 10x pipe diameter upstream and 3x pipe diameter downstream. It is recommended that a filter be installed upstream of the flow meter to prevent the paddle wheel from being damaged. Maximum 10% particulate Maximum particle size should not exceed.020 in cross section or length Do not flush the flow meter is installed with compressed air as this may damage the ceramic shaft. Pg. 5 of 7

PRODUCT SPECIFICATIONS: Materials: Body: PVC or PP Paddle: Tefzel Shaft: Zirconium Ceramic Seals: FPM or EPDM Max. Pressure: 150 psi @ 70ºF (see Chart 1 for operating pressures at elevated temperatures) Max. Temperature: PP: 180ºF (see Chart 1) PVC: 140ºF (see Chart 1) Electronics: 122ºF Min. Flow Velocity: Max. Flow Velocity: Viscosity Range: Accuracy: Repeatability: Voltage: Protection Class:.98 ft/sec. 32.8 ft/sec. NOTE: Meter is rated to 32.8 ft/sec. However, maximum recommended fluid velocity through any plastic piping system is eight feet per second (8 ft/s)..5 20 centistokes ± 1.0% of full scale ± 0.5% of full scale 10 30 VDC IP66, NEMA 4X The maximum recommended fluid velocity through any plastic piping system is eight feet per second (8 ft/s). Higher fluid velocity can create excess water hammer effect, resulting in property damage, personal injury, or even death. CAUTION Published operating requirements are based on testing of new meters using clean water at 70 F. Meter performance is affected by many factors including fluid chemistry, viscosity, specific gravity, flow rate, and temperature. These should be considered when sizing Hayward products. Chart 1: Operating pressures at elevated temperatures Pg. 6 of 7

PARTS: WARRANTY TERMS AND CONDITIONS: TWO YEAR WARRANTY: All products manufactured by Hayward are warranted against defects in material or workmanship for a period of two years from date of shipment. Our sole obligation under this warranty is to repair or replace, at our option, any product or any part or parts thereof found to be defective. HAYWARD MAKES NO OTHER REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The warranty set forth above is the only warranty applicable to Hayward products and in no event shall Hayward be liable for any delay, work stoppage, cartage, shipping, loss of use of equipment, loss of time, inconvenience, loss of profits of any direct or indirect incidental resulting from or attributable to a breach of warranty. The remedies under this warranty shall be the only remedies available. OUR MAXIMUM LIABILITY SHALL NOT IN ANY EVENT EXCEED THE CONTRACT PRICE FOR THE PRODUCT. TFSIOM Rev. 1 8/24/14 Pg. 7 of 7