Natural Ventilation Solutions for Urban Designs to incorporate Acoustic Considerations

Similar documents
TATTVAM ENVIRONMENTAL AND ENGINEERING SOLUTIONS, LLC. Indoor Air Quality Report for Weston Public Schools Weston, CT.

The Classroom Environment

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

VAV SYSTEM INDOOR AIR QUALITY CONSIDERATIONS FOR OFFICE SPACES

Techniques to achieve wind comfort & wind loads on buildings and appurtenances

AN IMPROVED CROSS VENTILATION MODEL IN WINDY REGIONS

Heat Stress Policy UFEHS-SAFE-04/04/01 Environmental Health and Safety Finance and Administration University of Florida

Results of Field Measurements and CONTAM Simulation. Building Science

CROSS CONTAMINATION OF IN-SUITE MURB VENTILATION SYSTEMS

Pressure Systems Safety Regulation

This is an author produced version of Determining the optimum spacing and arrangement for commercial wind towers for ventilation performance.

Lecture 11 Natural Ventilation (Passive Cooling)

Understanding Swimming Pool Ventilation. Presented by Tom Sands Mobile: CPD003/v03tcs2016

IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring

Thermal notation as a design tool evaluating the thermal comfort of pedestrians moving in spatial sequences

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

ANALYSES OF THERMAL COMFORT AND INDOOR AIR QUALITY UNDER STRATUM, DISPLACEMENT, AND MIXING VENTILATION SYSTEMS

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

ICE and European prestandard on health and cabin environment Dr. Christian Wolff (EADS Innovation Works)

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood

sorting solutions osx separator series

THERMAL COMFORT GUIDELINES

Proposal for amendments to Regulation No. 79 to include ACSF > 10 km/h

Assembly Committee Document 7.5

GUIDE. Feeling the Heat

HEAT, COLD, SOLAR ULTRAVIOLET & INCLEMENT WEATHER

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

Planning and Design of Proposed ByPass Road connecting Kalawad Road to Gondal Road, Rajkot - Using Autodesk Civil 3D Software.

ASPHALT PAVING LEVEL 1

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

STAR European Conference 2011

Evaluation of thermal comfort in naturally ventilated school classrooms using CFD

Arch 463 ECS Fall Midterm I. 30 Multiple Choice Questions

The Art of Natural Ventilation Balancing Heat and Air Flows?

PEDESTRIAN ACCOMMODATIONS DPS 201 AT ROUNDABOUTS

Building-related Sickness

CONCENTRATION CARBON DIOXIDE

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Your spa and the water

A Study on the Effects of Wind on the Drift Loss of a Cooling Tower

Technical Data Sheet MF010-O-LC

ACTU GUIDELINES FOR WORKING IN SEASONAL HEAT

This objective implies that all population groups should find walking appealing, and that it is made easier for them to walk more on a daily basis.

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

FABI Ventilation and Thermal Details Coral Springs, FL. Joseph Lstiburek, Ph.D, P.Eng, ASHRAE Fellow. Adventures In Building Science

ON INVESTIGATING INSTANTANEOUS WIND- DRIVEN INFILTRATION RATES USING CO 2 DECAY METHOD

Yakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting

McKinney Boyd High School Color Guard

NEWS: 20% discount on service agreements signed before 1st March 2010

Demand Control Ventilation Using CO 2

Uncertainties in Environmental Noise Assessments ISO 1996, Effects of Instrument Class and Residual Sound

Session 6 OPTIMISING PERFORMANCE IN A CHALLENGING CLIMATE

Plastics 4.0. Engineering Passion Seite 1

Airtightness Testing in Large Buildings: NESEA 2016

OptiCare. Optimising patient care

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Sports Grant Planned Budget Spending 2018/ 2019

6. Transport gases in blood

Ozone. Sensoric O3 3E 1

SILICONES UNLIMITED, INC. MATERIAL SAFETY DATA SHEET

OCCUPANT EVALUATION OF 7-HOUR EXPOSURES IN A SIMULATED AIRCRAFT CABIN PART 1: OPTIMUM BALANCE BETWEEN FRESH AIR SUPPLY AND HUMIDITY

Series Environmental Chambers

Mercury Flooring Testing and Mitigation: Guidance for Environmental Professionals

Table of contents. I Drawings 33. A1 Design criteria 1 A1.1 Local thermal discomfort indices... 1

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

EventLambeth - Post Event Report

International Journal of Advance Research in Engineering, Science & Technology

ESSENTIAL SAFETY RESOURCES

RECOMMENDED PERMIT CONDITIONS

Automatic extractor outlet

Standard: Knows the general structure and functions of cells in organisms

LABORATORY SAFETY SERIES: Laboratory Hoods

CHEM 3351 Physical Chemistry I, Fall 2017

Presented By: Kary S. Amin Nova Environmental, Inc. Nova Environmental, Inc.

Safety Data Sheet according to 1907/2006/EC, Article 31

Exponential Decay In 1989, the oil tanker Exxon Valdez ran aground in waters near

al qadisiya, kuwait city sustainable urban retrofit and design + ali irani, andré pina, katie gertz, nathaniel jones, nelson soares

S P A C A R E G U I D E

1 Exam Prep NSF/ANSI Tabs and Highlights

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Increase in Evaporation Caused by Running Spa Jets swhim.com

HAZARD RECOGNITION EVALUATION and CONTROL

"LABORATORY SAFETY SERIES"

VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM

Westminster s Joint Health and Wellbeing Strategy

Hands-on As a naturalistic data collection method

RED RTV SILICONE GASKET MAKER HI-TEMP PART NOS , 49292

Material Safety Data Sheet acc. to ISO/DIS 11014

Health & Safety Risk Assessment Form

Amherst School. Sport Premium Funding Report Autumn 2018

Natural Ventilation Applications in Hot-humid Climate: A Preliminary Design for the College of Design at NTUST

Q1.Four students tested their reaction times using a computer program. When a green light appeared on the screen the students had to press a key.

The Relationship between Speech and Peak flow values at various levels of work

PAPER 12. CONTINUOUS MEASUREMENTS OF AIR INFILTRATION IN OCCUPlED DWELLINGS P.F. COLLET. Technological institute Denmark

RTG 25. Introduction

Miami Retail Dehumidification Load peak )

Transcription:

Natural Ventilation Solutions for Urban Designs to incorporate Acoustic Considerations CIBSE NATURAL VENTILATION GROUP 22th May 2008 Natural History Museum Cromwell Road, London, SW7 5BD

Ventilation Rates in Primary Schools Professor Derek Clements Croome Principal Investigator Professor Hazim Awbi Co-Investigator Dr Marylin Williams Co-Investigator Dr Zsolt Bakó-Biró Research Fellow Dr Neena Kochhar Research Fellow

Approach Schools: 9 Primary Schools (Reading area < 30 miles) (3 weeks / school) Targeted age group: 10-11 years old children Measurements (9 schools): objective & subjective evaluations (repeated design) in 2 classrooms / school Performance tests (8 schools): Computer Pen & Paper

Physical t air (1.5m) measurements Spot Continuous Air temperature & RH Globe temperature Air velocity Carbon dioxide (CO 2 ) Lighting Noise level (during tests) Airborne particles (PM 2.5 ) Air change rate (SF 6 decay) t globe (1.1m) v air (1.1m) Light (0.7m) CO 2 (0.5m) t air (0.1m)

Performance tests PC 9 tests (20 min) Attention / vigilance Perceptual speed, Mental arithmetic Working memory Words recognition

CO 2 weekly pattern - during school hours (8 school building) Time dependent average across 16 classrooms 2500 Re-Circulated Air supply Average Re-Circulated Air Supply Fresh Air Supply Average Fresh Air Supply CO 2 concentration (ppm) 2000 1500 1000 Guideline 500 00:00 12:00 00:00 12:00 00:00 12:00 00:00 12:00 00:00 12:00 00:00 Monday Tuesday Wednesday Thursday Friday

% of time spent when CO 2 > 1500 ppm % of time when CO 2 exeeds 1500 ppm 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Uncontrolled Re-Circulated Air Supply Outdoor Air Supply Curve fit - Gompertz R2=0.971 0 500 1000 1500 2000 2500 3000 3500 Mean CO 2 concentration during school hours

% of time spent at hot/cold conditions % of time when Tglobe exeeds the range 20-24 C 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Uncontrolled Re-Circulated Air Supply Outdoor Air Supply Curve fit - Gauss R2=0.896 16 17 18 19 20 21 22 23 24 25 26 Mean globe temperature during school hours ( C)

CO 2 weekly pattern unvented classroom Effect of closed windows (uncontrolled condition) CO 2 (ppm) 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 Indoors Week1 Indoors Week2 Outdoors School Guideline 00:00 12:00 00:00 12:00 00:00 12:00 00:00 12:00 00:00 12:00 00:00 Monday Tuesday Wednesday Thursday Friday

Daily CO 2 patterns in classrooms School Guideline testin g

CO 2 during testing 5000 Fresh Air Supply Re circulated Air * CO 2 (ppm) 4500 4000 3500 3000 2500 2000 1500 1000 500 0 School Guideline S1 A S1 B S2 A S2 B S3 A S3 B S4 A S4 B S5 A S5 B S6 A S6 B S7 A S7 B S8 A S8 B Ventilation rates: 1-8 L/s per person

Effect of ventilation Relative performance 1.10 Re circulated Air Fresh Air Supply Relative Performance 1.05 1.00 0.95 0.90 Simple RT Choice RT Col Word Vig. Picture memory Word recognition 6 schools, 215 pupils

Effect of temperature 1 School, 30pupils 1200 1000 CO 2 (ppm) 800 600 400 200 0 Tg=23.1±0.8 C Tg=25.3±0.4 C

Conclusions The provision of fresh air supply reduced the concentration of classrooms pollutants (?) below recommended levels. Temperatures were easier to control at high ventilation rates. Without intervention and adequate window opening routines the existing ventilation rates in naturally ventilated school buildings remain below the minimum recommended levels. Increased ventilation significantly improved pupils performance by ~3% in attention and vigilance tasks and by 8-14% in tasks that require more complex skills such as spatial working memory and long term memory. Uncomfortable high temperatures significantly slowed down pupils reaction time even though good ventilation was provided.

Recommendations to the school pers. Equip classrooms with a monitoring device for: CO 2, temperature & relative humidity Take immediate actions for additional ventilation if CO 2 concentration exceeds 1000 ppm. Keep temperatures within comfortable range: 20-22 C Winter 22-24 C Summer Avoid moisture build up in classrooms and keep humidity levels below 60% during winter time. Create daily windows opening routines for the school: Morning, before children arrive During breaks After school hours during cleaning, vacuum cleaning Use odourless cleaning agents. Remember that dirty carpets can pollute the indoor environment.

Recommendation to school building designers, facilities managers and other stake holders: Ventilation should be provided to limit the concentration of carbon dioxide in all teaching and learning spaces to an average of 1000 parts per million (ppm) between the start and finish of teaching on any day. This is lower than the 1500 ppm recommended by Building Bulletin 101. Provide a minimum fresh air supply rate in all teaching and learning spaces of at least 8 L/s per person. It is worth noting that this fresh air supply rate falls within the recommendations of ASHRAE and other international standards. It is acknowledged that dedicated ventilation systems may be necessary to achieve the above targets. Provide means of controlling classroom temperatures to the limits specified earlier.

Recommendations (contd.) To avoid excessive overheating, it may be necessary to limit solar gain by utilising passive means such as thermal mass, orientation, fenestration and external/internal shading devices. Based on observations during this study and related research it is recommended that wall-to-wall carpets are avoided. The choice of opening windows and their location is important in the design of effective natural ventilation.