Digital Vacuum Regulator

Similar documents
Digital Vacuum Regulator

Digital Vacuum Regulator

KEM Scientific, Inc. Instruments for Science from Scientists

DPC-30 DPC-100. Reference Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

SPECIFICATIONS APCEPH1

UNIVERSAL MASK TEST SYSTEM

RAM 4021 Operation Manual

PS-425 Pitot-Static/Air Data Tester

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

MODEL 6600 Rev. B4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE. SUGAR LAND TX (281) FAX: (281)

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Instruction Manual Model Borehole Pressure Cell

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

R E D I C O N T R O L S

700 SERIES BMS II BUBBLER MONITORING SYSTEM

BUBBLER CONTROL SYSTEM

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Overview. Front Panel: Keypad and Display

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

PM105 PRESSURE METER USER S MANUAL

BUBBLER CONTROL SYSTEM

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

HAS2400 Hepa Air Scrubber

RAM Operation Manual

ACV-10 Automatic Control Valve

INSTALLATION & MAINTENANCE INSTRUCTIONS

Constant Pressure Inlet (CCN) Operator Manual

with O 2 Controller Instruction Manual

D10 Inflator Quick Start Manual

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

RAM 4021-DPX Operation Manual

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

VICI Metronics Dynacalibrator Model 150 Instruction Manual

MODEL 100 NITROGEN INFLATION CART

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

User Manual MFCS TM -EZ

Model 106 DPI "Micro-switch" Installation and Operating Instructions

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Installation Instructions Air Compressor Part # 2780, 2781

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

MODEL 6500 Rev. F4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE SUGAR LAND TX, (281) FAX: (281)

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

CSA Sample Draw Aspirator Adapter Operator s Manual

Reverse Osmosis System Installation Guide and Operation Manual.

ASDX Series Silicon Pressure Sensors

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

RC 195 Receiver-Controller

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Owner s Manual Humiport 10/20

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

RK-IR Sample Draw Aspirator Adapter Operator s Manual

WARRANTY, QUICK START GUIDE

Section 1: Overview... 6 Features... 6 Supported Software Part 1: Getting Started 7

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

MODEL 6500 Rev. E USER'S MANUAL

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

92831 TEL: (714) FAX:

628 Differential Pressure Decay Leak Tester

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

SCALE / SORTER OPERATORS MANUAL (DATED 2004 PRESENT)

Interface Devices, Inc. Hydraulic Mini Mule

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Marschalk Model # 94000

Do Not Print This Page.

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Electronic Control Pump Instruction Manual

RJE INTERNATIONAL, INC.

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Using the UltraRAE. Firmware 2.35

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Cover Page for Lab Report Group Portion. Pump Performance

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

ACCURA D80 User Manual

M104 Series: Digital Manometer: 0.1 % of Full Scale

MP15 Jockey Pump Controller

Operating Manual. Model BAC-30RT30/BAC-30DC

User s Guide. Pressure Controller for liquid delivery systems

Automatic Isokinetic Sampler. ST5 Evo

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

444C DUAL PERFORMANCE VALUE PACK

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

TR Electronic Pressure Regulator. User s Manual

LM6 LEATHER MOISTURE METER

Volt 8000 Series Heated Regulator

DeeterFlow Automatic Liquid Dispenser

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Transcription:

Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-280

INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS............................. 3 KEM-NET DATA LOGGING AND CONTROL SOFTWARE.......... 4 2. REGULATOR DESCRIPTION..................................... 4 3. OPERATIONS GUIDE............................................ 5 3.1 How the Controller Adjusts Pressure............................. 5 3.2 Adjusting the Vacuum Valve Delay Time......................... 6 3.3 Adjusting the Amount of Hysteresis............................. 7 3.4 Changing the Display Resolution............................... 7 3.5 Correcting Offset in the Displayed Pressure....................... 8 4. TROUBLE SHOOTING.......................................... 9 5. FACTORY DEFAULT PARAMETERS............................. 10 Warranty J-KEM Scientific, Inc. warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 6 months from date of purchase. If the unit should malfunction, it must be returned to the factory for evaluation. If the unit is found to be defective upon examination by J-KEM, it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive vibration, corrosive materials, or misuse. Components which wear or are damaged by misuse are not warranted. This includes valves and fuses. THERE ARE NO WARRANTIES EXCEPT AS STATED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL J-KEM SCIENTIFIC, INC. BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES. THE BUYER'S SOLE REMEDY FOR ANY BREACH OF THIS AGREEMENT BY J-KEM SCIENTIFIC, INC. OR ANY BREACH OF ANY WARRANTY BY J-KEM SCIENTIFIC, INC. SHALL NOT EXCEED THE PURCHASE PRICE PAID BY THE PURCHASER TO J-KEM SCIENTIFIC, INC. FOR THE UNIT OR UNITS OF EQUIPMENT DIRECTLY AFFECTED BY SUCH BREACH. Returns, requests for service and inquires should be directed to: J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax: (314) 863-6070 Internet Catalog: http:\\www.jkem.com E-mail: jkem911@jkem.com 2

Section 1 Quick Operating Instructions NOTICE: When making a connection to the vacuum inlet or outlet fitting on the back of the controller, it is critically important that the vacuum tube does not rotate or damage to the controller will result. When making a connection, use a pair of pliers to prevent the tube from rotating while making any connection to the tubing. 1. Connect the Regulator to the Equipment Connect the vacuum pump (or the vacuum source) to the tube marked Inlet. Connect the instrument in which the vacuum is to be regulated (i.e., rotary evaporator, distillation setup, etc.) to the tube marked Outlet. There should be no restrictions (i.e. valves, stopcocks) between the Outlet port and the equipment you re regulating. Best results are obtained when large diameter tubing is used to make this connection. 2. Set up the Regulator 1. Plug the vacuum pump into the 120VAC receptacle on the back of the DVR-280. Turn the power switch to the vacuum pump On. 2. Set the regulator selection switch on the front of the DVR-280 to the Off position. 3. Turn power to the DVR-280 On. Regulator Selection Switch 3. Enter the Setpoint Pressure. The default display of the meter is the pressure inside the piece of equipment the DVR is attached to. The desired pressure (or setpoint) is entered by holding in the * button on the front of the meter and simultaneously pressing either the t button to decrease or the s button to increase the setpoint. The setpoint, which appears as a blinking number, can be seen at any time by holding in the * button. 4. Move the Regulator Selection Switch to the METER Position. When set to the Meter position, the regulator maintains the attached equipment at the setpoint pressure entered in step 3. 5. For Controllers Equipped with Needle Valves, open the valve until the equipment is evacuated at a reasonable rate. When at the setpoint, adjust the valve for stable pressure regulation. Leave the needle valve in this position for future use. Once the valve is set for a reasonable evacuation rate it doesn t require further adjustment. 3

KEM-Net Data Logging and Control Software The USB port on the back panel of the controller is an interface to J-KEM s KEM-Net Software. KEM-Net is free and can be downloaded from J-KEM s web site at www.jkem.com. KEM-Net provides remote control of up to 8 controllers, graphical presentations of each digital meter and time & temperature plots. Highlights of KEM-Net include: * GLP and GMP compliant data logging * Runs a 12 step temperature ramp * Logging of Time and Temperature * Logging of % Power for Exo and Endotherm detection * Program KEM-IO Actions (Section 3.10) * Over- & Under-temperature alarm functions. KEM-Net also includes a virtual comm port driver that provides a simple ASCII interface to operate and data log the controller from LabView or other software packages. New Features: GMP compliant data logging Exo and Enotherm monitoring KEM-IO Remote Control of Laboratory Equipment based on Time and Temperature KEM-IO is an optional feature that allows the controller to respond to inputs from instruments, like a vacuum sensor or a hood door switch, and also to control instruments, like stirrers and chillers based on reaction temperature. KEM-IO automates programs as simple as: Heat my reaction to 80 o C, then turn on my peristaltic pump to add reagents. or as sophisticated as: Turn on my stirrer, then ramp my reaction from 25 o C to 100 o C if 45 minutes, hold for 2 hours, then turn off heating. When the reaction cools to 50 o C, turn off the stirrer. If at any point the reaction exotherms and heats above 110 o C, turn on my chiller and keep it on until I manually reset the system. Contact J-KEM for additional information. 4

Section 2 Regulator Description The DVR-280 is optimized for use with diaphragm vacuum pumps. The lifetime of the diaphragm of a diaphragm pump is significantly reduced when the pump is turned on while the pump is under vacuum. To prolong the lifetime of the diaphragm, the DVR-280 turns on the pump while it s at atmospheric pressure, then once the pump has started it opens a valve connecting the pump to the reaction system. When the reaction system is evacuated to the setpoint pressure, the controller closes the vacuum valve and then turns off the vacuum pump. This sequence of events can continue indefinitely. 7- Serial Comm Port (on back) 8-Vacuum Pump Power Outlet (on back) 4 6 1 2 5 3 1. Pressure Display. The default display is the pressure inside the attached piece of equipment in units of mm of Hg (torr). The setpoint pressure can be seen any time by holding in the * button. 2. Control Key. Pressing (and holding) this button causes the regulator to display the setpoint pressure as a blinking number in the display. The setpoint is changed by holding in the control key and simultaneously pressing the s key to increase or the t key to decrease the displayed value. 3. Decreases (t) or increases (s) the setpoint pressure when the * button is simultaneously held in. 4. Regulator s Power Switch. 5. Indicates the position of the regulator selection switch (#6). 6. Regulator Selection Switch. A three position switch that determines the pressure in the attached equipment. The different switch positions have the following effects: Meter: Off: Evacuates the attached equipment to the setpoint pressure entered in the controller. Isolates the vacuum pump from the attached equipment and turns the vacuum pump off. Full Vacuum: Turns on the vacuum pump and evacuates the attached piece of equipment to the limit of the vacuum pump, independent of setpoint pressure entered into the meter. 7. Optional serial port for remote PC control and data acquisition. 8. Power connection for diaphragm vacuum pump. Plug the power cord from the vacuum pump into the 120vac outlet. Maximum current is 10 amps @ 120vac. 5

Section 3 Operations Guide 3.1 How the Controller Adjusts Pressure For the controller to regulate pressure, enter a setpoint into the meter, for example 200mmHg, and set the regulation selection switch to the Meter position. If the setpoint pressure is below the current pressure the controller turns the vacuum pump on and then pauses for a user set period of time to allow the pump to generate a vacuum. After this delay, the controller opens a vacuum valve that normally isolates the vacuum pump from the reaction setup. The delay time between starting the pump and opening the vacuum valve can be set by the user (see below), the default value is 2 seconds. The system continues to evacuate until the system pressure equals the setpoint pressure. At this point, the controller closes the vacuum valve, isolating the system, and turns off the vacuum pump. Vacuum pump turns on Vacuum Vacuum valve opens Vacuum Profile 202mm Hg 200mm Hg Point 2 Pressure offset (hysteresis) Point 1 Time Setpoint To prolong the life of the pump, it s desirable to limit how frequently it s turned on and off to adjust the system pressure. This is done by entering an allowable pressure band for the system as opposed to a discrete pressure point. The wider the allowable band, the less frequently the pump is turned on, but in most applications it s desirable to limit the pressure band to a fairly narrow range. The pressure band is know as hysteresis, and the user can program the amount of hysteresis the controller allows (see below). By default, the DVR-280 is set for 2mmHg of hysteresis. Hysteresis always tracks the setpoint. For example if hysteresis is set for 2mmHg then when a setpoint of 200mmHg is set, the upper limit of the pressure band is automatically set to 202mmHg. If the setpoint is changed to 50mmHg, then the upper limit of the pressure band is automatically set to 52mmHg. Every time the setpoint is changed the upper limit of the band is automatically set to the pressure which is the amount of hysteresis above the new setpoint. 6

3.2 Adjusting the Vacuum Valve Delay Time The user can set the delay time between when the vacuum pump is turned on and the vacuum valve opens to connect the pump to the vacuum system. The delay allows the pump time to evacuate the tubing connecting the pump to the controller before opening the vacuum valve. By default the delay time is set to 2 seconds, but the time can be adjusted to any value in the range of 0 to 15 seconds. To change the delay time: 1) Take off the black cover of the DVR-280 from the white base by removing the screws holding the cover to the base. 2) Under the digital meter is a circuit board that has 4 in-line toggle switches. The time specified by the position of these toggle switches as shown in the table below. When the meter is pointed to your right, switch 1 is on the left and switch 4 is on the right. A switch is ON when it s down and OFF when it s up. Delay Time (seconds) Switch 1 Position Switch 2 Position Switch 3 Position Switch 4 Position 0 ON ON ON ON 1 OFF ON ON ON 2 ON OFF ON ON 3 OFF OFF ON ON 4 ON ON OFF ON 5 OFF ON OFF ON 6 ON OFF OFF ON 7 OFF OFF OFF ON 8 ON ON ON OFF 9 OFF ON ON OFF 10 ON OFF ON OFF 11 OFF OFF ON OFF 12 ON ON OFF OFF 13 OFF ON OFF OFF 14 ON OFF OFF OFF 15 OFF OFF OFF OFF 7

3.3 Adjusting the Amount of Hysteresis Whenever a setpoint pressure is entered by the user, a pressure offset that is 2mm Hg (factory default) above the setpoint is automatically entered into the meter. The purpose of the offset is to limit how often the vacuum pump is turned On and Off to maintain system pressure. The amount of offset, or hysteresis, can be set by the user by following the procedure below. The allowable range for hysteresis is 0.0 to 760mmHg. 1 Press and hold in both the and keys on the front of the digital meter until the word tune appears in the display, then release both keys. 2 Press the key once and the word band will appear in the display. Next, hold in the * key, then while holding in the * key press the or keys until the amount of desired hysteresis appears in the display. For example, if you want 10mm of hysteresis, hold the or keys until 10 shows in the display. Let go of all the keys. 3 Press the key 5 times until the word ofst appears in the display. Next, hold in the * key, then while holding in the * key press the or keys until the amount of desired hysteresis appears in the display. For example, if you want 10mm of hysteresis, hold the or keys until 10 shows in the display. Let go of all the keys. NOTE: The value entered in Step 3 must be the same value that was entered in Step 2. 4 Press and hold in both the and keys until the system pressure appears in the display, then release both keys. 3.4 Changing the Display Resolution. The procedure below allows you to select the pressure display resolution of your J-KEM vacuum controller. This procedure allows you to specify 0.1 or 1 torr resolution. 1. Press and hold in both the and keys on the front of the digital meter until the word tune appears in the display, then release both keys. 2. Press the key until LEVL appears in the display. Next, hold in the * key, then while holding in the * key press the key until 3 appears in the display. Let go of all the keys. 3. Press the key 11 times until ver appears in the display. Next, hold in both the and keys for about 10 seconds until the display changes (what the display changes to can be variable, so just hold in the button until ver goes away). Press the or key until LoCk appears in the display. While holding in the * key, press the or key until NonE appears in the display. Let go of all the keys. 4. Press the key until LEVL appears in the display. Next, hold in the * key, then while holding in the * key press the key until 2 appears in the display. Let go of all the keys. 5. Press the key 7 times until disp appears in the display. Next, hold in the * key, then while holding in the * key press the or keys until 1, to select 1 torr resolution, or 0.1, to select 0.1 torr resolution, appears in the display. Let go of all the keys. 6. Press and hold in both the and keys until the temperature appears in the display, then release both keys. Temperature is now displayed in the selected units. 8

3.4 Correcting Offset in the Displayed Pressure. A small amount of error can develop in the displayed pressure ( 2 torr) of the vacuum regulator. This is due to the wide pressure range of the transducer used and accuracy better than this is usually not possible. For display errors greater than 2mm, the controller can be calibrated using the procedure below (For users experienced with J-KEM s meter, do not correct pressure using the ZEro function. This introduces an error, not a correction). Before beginning this procedure you will need to know the correct barometric pressure inside your lab. This procedure should only be performed by a qualified electrician. 1. Remove the controller s cover. 2. Plug the OUTLET port of the regulator and set the regulator selection switch to the FULL VACUUM position. 3. Let the controller warm up for 10 minutes. 4. Connect a vacuum pump to the INLET port, turn it on and let it evacuate the controller to as close to 0 torr as possible. Measure the pressure in the system using a manometer. The regulator must be evacuated to as close to 0 torr as possible before the adjustment in step 5 is performed. 5. Adjust the Zero pot until the reading on the meter matches the actual pressure. 6. Turn the vacuum pump off and unplug the OUTLET port. Adjust the Span pot until the meter reads the actual barometric pressure in the lab. 7. Turn the controller off and replace the cover. 9

Section 4 Trouble Shooting Symptom The pump does not start The pump does not start at all The pump starts when the system is first turned on, but not when the system is evacuated Corrective Action Verify that the circuit breaker protecting the pump has not tripped. Reset the circuit breaker. Diaphragm pumps are designed to start when the diaphragm is at or close to atmospheric pressure, but will not start reliably when the diaphragm is under a vacuum pressure. The line or hose that connects the vacuum pump to the DVR-280 must have a small leak so that this portion of the system can return to atmospheric pressure when the pump is not running. Usually, normal leaks in the system that connect the DVR-280 to the vacuum pump are sufficient for this purpose, but if this part of the system is plumbed leak-proof, the user may have to intentionally introduce a small leak to allow the pump to return to atmospheric pressure. 10

Section 5 Factory Default Parameters. DVR-280 Parameter Value Tune Off Band 2 Int Off Der Off DAC 1.5 Cycle time On/Off Offset 2.0 SP.LK Off Sprr 0 Sprn Off Soak -- Set2 0 Bnd2 2 Cyc2 On/Off SP1P hand off PL1 100 PL2 100 SP2A none SP2b none disp 0.1 hi.sp 800.0 lo.sp 0.0 inpt Lin3 unit set sp1.d Rly sp2.d SSd burn Up.Sc Reu.d 1d.2d Reu.l 1i.2i span 0 Lock Level 2 11