PRS6 Auxiliary Valves

Similar documents
Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Transair: Advanced pipe systems For Nitrogen Applications

VP04 Remote Control. Pneumatic Proportional Remote Control Valve

K220LS Mobile Directional Control Valve

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK September 2005

Directional Control Valves

K220LS Mobile Directional Control Valve

Directional Control Valves

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

HPRV Proportional Relief Valve. Catalog 4190-HPRV

M402LS Mobile Directional Control Valve

Parker Tube Fabricating Equipment. Catalog TFE

Update of trade weights data underlying the EERs and HCIs

Remote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004

High Precision Regulators R210 / R220 / R230 Series

Bladder Accumulators. EBV - ELG from 20 to 80 bar

Breathable Compressed Air

Summary Charts Scenario 3 - Low Change Scenario

Summary Charts Scenario 1 - Base Scenario

THE WORLD COMPETITIVENESS SCOREBOARD 2011

Shock Adsorbers. Series MC-SC

VGU. Charging Set Vérificateur Gonfleur

ASB Accumulator Safety Blocks

Air Preparation System P3L Lite Series. Fully Modular with 1/4 Body Ports

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Max Sort Sortation Option - Letters

damage due to improper handling, carelessness, or normal wear and tear damage due to tampering by persons lacking Porsche Design authorisation

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001

Piston Accumulators. A Series 250 and 350 bar

I. World trade in Overview

STATISTICS

MARIE SKŁODOWSKA-CURIE ACTIONS STATISTICS INDIVIDUAL FELLOWSHIPS

Oil and Gas Innovation: Upstream. Worldwide.

Global Construction Outlook: Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009

European Research Council

PIN Flash 18 - Background tables

Pneumatic Linear Drive OSP-P ATEX Operating Instructions ORIGA SYSTEM PLUS

2018 Hearthstone Wild Open. Official Competition Rules

Total points. Nation Men kayak Women kayak Men canoe Women canoe Total 600 BELARUS KAZAKHSTAN 54. Page 1 of 4. powered by memórias

Invitation to. The 36th World Amateur Go Championship in Bangkok. Outline

The 11th Korea Prime Minister Cup International Amateur Baduk Championship

Confidence through experience. Track record as of 30 June 2012

Pneumatic cylinders. Series P5T Short Stroke Thrusters

IBAN Mandatory Countries for International Payments

Welcome to KNX Scientific Conference 2012 Las Palmas Gran Canaria Watch how international KNX has become!

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Premium T-Shirt. Premium T-Shirt -KIDS. T-Shirt Lady Fashion. Price Public 29,00 Availability: 5 to 7 work days

January Deadline Analysis: Domicile

Desalination From theory to practice People, Papers, Publications. Miriam Balaban EDS Secretary General

Firearms & parts firearms & parts firearms & parts rocket launcher components

June Deadline Analysis: Domicile

Table 34 Production of heat by type Terajoules

TERMINAL BLOCK SUMMARY

Production, trade and supply of natural gas Terajoules

German Machine Tool Industry - Key Figures

Table I. NET CALORIFIC VALUES OF ENERGY PRODUCTS GJ/ton

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

European Values Study & World Values Study - Participating Countries ( )

The globalisation of sporting events: Myth or reality?

USTA Player Development 2017 Excellence Grant Criteria Jr Girls, Collegiate & Professional Players

New rules, new opportunities: a potential for growth

WHAT IS KING OF KINGS (KOK)?

Table I. NET CALORIFIC VALUES OF ENERGY PRODUCTS GJ/ton

IBSA Goalball World Rankings 31 December 2017 Men's Division

NITROGEN CHARGING KIT type PC 11.1 E 04-11

NITROGEN CHARGING KIT type PC 11.1 E 01-12

FIL Qualifying Event Proposal. Problem Statement. Proposal for voting at GA

INTERNATIONAL SKATING UNION

Student Nationality Mix for BAT Bath

I N T E R N A T I O N A L S K A T I N G U N I O N

Statistics th Four Days Marches. Barometer 2013 Number of walkers Registrations Signed in

Post Show Report April 2015, Moscow, Russia. #ipheb

I N T E R N A T I O N A L S K A T I N G U N I O N

UPA All fluids. Full flow All stainless steel

LOCAL BROADCASTER DUBAI DUBAI SPORTS CHANNEL 01-Nov-13 01:00 02:00 Hlts Day 1 01:00 EUROPE DURATION HH:MM

HydroCOM: High energy savings and excellent controllability

Stockholm s tourism industry. November 2016

Finance Domain Task Force

Stockholm s tourism industry. December 2016

UPA All fluids. Full flow All stainless steel

Portuguese, English, and. Bulgarian, English, French, or

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

INTERNATIONAL STUDENT STATISTICAL SUMMARY Spring 2017 (Final)

FACT Sheet. FIFA Competition winners at a glance. Men s Competitions. FIFA World Cup (staged every four years)

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

TV MEDIA ANALYSIS END SEASON Expertise by Nielsen Sports Your contact person(s): Marco Nazzari, Pamela Delmiglio

Posting of workers in the European Union and EFTA countries : Report on A1 portable documents issued in 2010 and 2011

2015/16 UEFA European Women s Under-17 and Women s Under-19 Championships Elite round draws

UPB All fluids. Full flow All stainless steel

2014/15 UEFA European Under-17 and Under-19 Championships Elite round draws. 3 December 2014, Nyon, Switzerland

IR-Pay Go Rates. There are three pricing groups for Pay Go rates for International Roaming as follows:

Value Exported (CDN$) Support Systems ,165 firearms ,389 firearms ,465 firearms ,500 rocket launchers

TABLE 1: NET OFFICIAL DEVELOPMENT ASSISTANCE FROM DAC AND OTHER DONORS IN 2012 Preliminary data for 2012

CMMI Maturity Profile Report. 30 June 2017

OVERALL STANDING WORLD ROWING CUP 2013

EU-Labour Force Survey November 2015 release. Setup for Importing the Anonymised Yearly Data Sets for

Demography Series: China

OECD employment rate increases to 68.4% in the third quarter of 2018

SPEEDY SERVICES WALES SENIOR OPEN June 2013 TELEVISION DISTRIBUTION LIST (as at 13th June 2013)

Transcription:

Pressure Reducing Valves

General Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue are updated continuously, the validity of the information given should always be confirmed. For more detailed information, please contact Parker. WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale Please contact your Parker representation for a detailed Offer of Sale. 2 Parker Hannifin

General Information Applications The is a three-way pressure reducing valve that has been developed to give reduced pressure in a particular part of a hydraulic system. The valve maintains the secondary pressure setting constantly, regardless of pressure variations on the primary side. A common application is in pilot circuits in hydraulic and electrohydraulic servo systems, where the pressure is taken from the main system and reduced by the to a level that is suitable for the pilot circuit. Construction and function The valve housing is manufactured from continuously-cast grey iron and contains a precision-ground spool. To keep oil consumption at a low level, the spool has positive overlapping. This gives a certain difference in secondary pressure at different flow take-off rates. For this reason, the valve setting should be made with the desired flow rate passing through the valve. When a high primary pressure is reduced to a low secondary pressure (pressure differential over 150 bar), pressure reduction should be effected in two stages using two valves connected in series. Advantages Compact and easy to install. Easy to adjust within respective pressure range. Can be factory-set and sealed to prevent unauthorized pressure changing. Highly suited for use as a reducing valve in pilot circuits where the pilot pressure is taken from the main circuit. Withstands high pressure shocks in the tank connection. Optional equipment Numerous other options are available for the. For further information, please contact your Parker representative. Spool for two-way function. Hand wheel for easy changing of pressure setting. Flanged version of for flanging directly to, e.g. a valve block. Adjuster device for external control of secondary pressure by means of a pilot pressure. 3 Parker Hannifin

Technical Data Possible pressure setting ranges (applicable range will depend on pressure setting you specify) Secondary pressure 4-10 bar 11-20 bar 21-30 bar 31-45 bar 46-150 bar 150 bar to any value below 250 bar. Primary pressure Max. 250 bar Tank pressure Max. 250 bar in pressure shocks. Recommended reduction (differential between primary and secondary pressure) Max. 150 bar Pressure-setting flow rate Pressure should be set with desired flow rate (l/min) flowing through the valve. Recommended flow rate Max. 30 l/min depending on secondary pressure. See diagram. Connections All connections are available in two versions: - G1/4 (BSP pipe thread) for flat seal (type Tredo) according to ISO 228/1. - 9/16-18 UNF-2B for O-ring seal according to SAE J1926/1. Leakage Connection P to connection T max. 0.15 l/min at pressure differential of 100 bar and oil viscosity of 30 mm/s 2. Weight Approx. 1.0 kg Hydraulic fluids Best performance is obtained using mineral-base oil of high quality and cleanness in the hydraulic system. HLP hydraulic fluids (DIN 51524), automatic-gearbox oil type A and API CD engine oils can be used. If in doubt, please contact Parker for further information. For best function, oil viscosity should be between 15 and 45 mm/s 2 (cst). p (bar) 200 180 160 140 120 100 80 60 40 20 200 180 160 140 120 100 0 0 5 10 15 20 25 30 35 Pressure limiting characteristic for p (bar) 80 60 40 20 0 0 5 10 15 20 25 30 35 Pressure reducing characteristic for S q (l/min) q (l/min) Filtration Filtration should be arranged so that Target Contamination Class 18/16/13 according to ISO 4406 is not exceeded. Temperature Temperature range, fluid: -20 C to + 70 C Temperature range, ambient: -40 C to +70 C Temperature-shock resistance: max. 100 C/second General Technical data in this catalogue is applicable using mineral base oil according to DIN 51524 at a viscosity of 30 mm 2 /s and temperature of 50 C. P T Functional symbol for 4 Parker Hannifin

Dimensions T S P 39 (1.54) 9 (0.35) 27 24 (1.06) (0.94) 92 A 30 max (3.62) (1.18 max) 32 (1.26) 9 (0.35) 15 (0.59) 15 (0.59) 25 (0.98) 30 (1.18) 50 (1.97) Fixing holes Ø6,5 (2x) (Ø0,26 2x) A = 15 at 4-45 bar A = 44 at 46-250 bar 5 Parker Hannifin

Ordering Please use ordering-code system in chart below to specify your valve. The ordering numbers in the table below apply to certain standard settings (please cross-reference with ordering-code system chart) and can be used directly when ordering. Ordering number G-10-01-O 8234 8906 35 G-20-01-O 8234 8906 25 G-30-01-O 8234 8906 33 G-40-01-O 8234 8906 34 G-100-01-O 8234 8907 08 Ordering code Connection Secondary pressure Pressure setting Sealing O P Sealing Not sealed Valve sealed with sealing wire and seal Pressure-setting flow rate Secondary pressure is set while desired flow rate (l/min) is passing through valve. Flow range: 0-30 l/min Secondary pressure Valve is delivered preset at specified secondary pressure (pressure range 4 bar to marginally below 250 bar) G U Connection G1/4 (BSP pipe) thread 9/16-18 UNF-2B thread 6 Parker Hannifin

7 Parker Hannifin

Parker Worldwide Europe, Middle East, Africa AE United Arab Emirates, Dubai Tel: +971 4 8127100 parker.me@parker.com AT Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 parker.austria@parker.com AT Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 parker.easteurope@parker.com AZ Azerbaijan, Baku Tel: +994 50 22 33 458 parker.azerbaijan@parker.com BE/LU Belgium, Nivelles Tel: +32 (0)67 280 900 parker.belgium@parker.com BY Belarus, Minsk Tel: +375 17 209 9399 parker.belarus@parker.com CH Switzerland, Etoy Tel: +41 (0)21 821 87 00 parker.switzerland@parker.com CZ Czech Republic, Klecany Tel: +420 284 083 111 parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0)2131 4016 0 parker.germany@parker.com DK Denmark, Ballerup Tel: +45 43 56 04 00 parker.denmark@parker.com ES Spain, Madrid Tel: +34 902 330 001 parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0)20 753 2500 parker.finland@parker.com FR France, Contamine s/arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com GR Greece, Athens Tel: +30 210 933 6450 parker.greece@parker.com HU Hungary, Budaoers Tel: +36 23 885 470 parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0)1 466 6370 parker.ireland@parker.com IT Italy, Corsico (MI) Tel: +39 02 45 19 21 parker.italy@parker.com KZ Kazakhstan, Almaty Tel: +7 7273 561 000 parker.easteurope@parker.com NL The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 parker.nl@parker.com NO Norway, Asker Tel: +47 66 75 34 00 parker.norway@parker.com PL Poland, Warsaw Tel: +48 (0)22 573 24 00 parker.poland@parker.com PT Portugal, Leca da Palmeira Tel: +351 22 999 7360 parker.portugal@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com RU Russia, Moscow Tel: +7 495 645-2156 parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0)8 59 79 50 00 parker.sweden@parker.com SK Slovakia, Banská Bystrica Tel: +421 484 162 252 parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: +386 7 337 6650 parker.slovenia@parker.com TR Turkey, Istanbul Tel: +90 216 4997081 parker.turkey@parker.com UA Ukraine, Kiev Tel +380 44 494 2731 parker.ukraine@parker.com UK United Kingdom, Warwick Tel: +44 (0)1926 317 878 parker.uk@parker.com ZA South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com North America CA Canada, Milton, Ontario Tel: +1 905 693 3000 US USA, Cleveland (industrial) Tel: +1 216 896 3000 US USA, Elk Grove Village (mobile) Tel: +1 847 258 6200 Asia Pacific AU Australia, Castle Hill Tel: +61 (0)2-9634 7777 CN China, Shanghai Tel: +86 21 2899 5000 HK Hong Kong Tel: +852 2428 8008 IN India, Mumbai Tel: +91 22 6513 7081-85 JP Japan, Fujisawa Tel: +81 (0)4 6635 3050 KR South Korea, Seoul Tel: +82 2 559 0400 MY Malaysia, Shah Alam Tel: +60 3 7849 0800 NZ New Zealand, Mt Wellington Tel: +64 9 574 1744 SG Singapore Tel: +65 6887 6300 TH Thailand, Bangkok Tel: +662 717 8140 TW Taiwan, New Taipei City Tel: +886 2 2298 8987 South America AR Argentina, Buenos Aires Tel: +54 3327 44 4129 BR Brazil, Cachoeirinha RS Tel: +55 51 3470 9144 CL Chile, Santiago Tel: +56 2 623 1216 MX Mexico, Apodaca Tel: +52 81 8156 6000 Ed. 2012-11-01 2012 Parker Hannifin Corporation. All rights reserved. Catalogue HY17-8541/UK, POD, 11/2012, ZZ EMEA Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) US Product Information Centre Toll-free number: 1-800-27 27 537 www.parker.com Your local authorized Parker distributor