Pressure Reducing Valve

Body Material: PVC, PP, PVDF Bonnet Material: Glass Filled PP Size: ½ - 2 Pressure Rating: 150 psi Set Pressure: 4 to 150psi Seals:

pressure reducing valves

Diaphragm pressure gauge guard MDM 902

Instruction presentation Special valves

Pressure relief valve

Pressure relief valve

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Diaphragm Pressure Keeping Valve

Type overview. R B2 en-gb subject to changes 1

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Armatures for analytical probes

Diaphragm relief valve

Installation, operation & maintenance manual - original version

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Pressure Reducing Valve for Steam Type 2333 A

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

ITT RICHTER CHEMIE-TECHNIK

Installation and Operating Instructions Bypass Flow Meter DST

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Flowmeter. Original operating manual DFM

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Glass tube flowmeters Series 2000

AVP-F. p setting range (bar) Code No. 003H6200

Precision pressure regulators LRP/LRPS

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2-Port Seat Valves with Flange, PN 16

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

2-Port Seat Valves with Flange, PN 16

Products no longer available

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Pressure regulating valves Types OFV, OFV-SS

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Pressure and Flow Control Valves DBGM, German and European Patents

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Gas Pressure Regulator HON 300

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Overview of types. Technical data. Safety notes

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Measurement of Low GAS & Liquid Flows

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Self Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Engineering Data Sheet

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Pressure independent control valve (PICV) FLOWMATIC

Solenoid valves VZWF, force pilot operated

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Pressure reducing valves Index

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overview of types. Technical data

Flanged pressure reducer/stabilizer VRCD

SEries 29 Hydrant valves installation, operation & maintenance manual

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Diaphragm Valve, Metal

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

HYDRAULIC CONTROL VALVES

Pure-Flo Handwheel Operated Valves (970) Instruction Manual

3-port seat valves with externally threaded connection, PN 16

2-port and 3-port valves PN 16

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Diaphragm Valve, Metal

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Regulating valves REG-SA and REG-SB

RS(H)20, 25 USER MANUAL

Transcription:

Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long service life reliable diaphragm fastening with standard stainless steel screws pressure reduction by throttling at the valve seat as standard with two lateral threaded connections for pressure gauges or diaphragm pressure gauge guards Application chemical plants industrial plants water treatment Intended Use for reduction of system pressures to virtually constant working pressures Valve Function The opened valve is in equilibrium between the inlet pressure (primary side) and the lower working pressure (secondary side). If the working pressure goes above or below the desired value, the large area membrane is lifted against the spring force or pressed down by the spring force. The valve starts closing or opening until the equilibrium condition is reached again, i.e. the working pressure remains constant independent of an increasing or decreasing inlet pressure (as long as the inlet pressure > working pressure). The valve piston is designed to match the plastic characteristics and is generously dimensioned for reliably withstanding high closing forces at the valve seat. The diaphragm separates the medium in the valve body from the bonnet and the atmosphere. The principle ensures that the secondary pressure acting on the diaphragm is compensated by the spring force which is held in equilibrium by the pressure setting. Flow Media Technically pure, neutral and aggressive fluids, provided that the selected valve materials coming into contact with the media are resistant at the operating temperature according to the ASV-resistance guide. For nitric acid or sulfuric acid please specify the precise operating conditions of the application. Valve Setting Set or adjust the working pressure to be kept constant at the adjustment screw with the aid of pressure gauges (ASV diaphragm pressure gauge guard with pressure gauge, type MDM 90) in the pipe system after removing the protection cap. The adjustment screw is secured by a counter nut and can be sealed against unauthorized adjustment, if necessary. There are two types of application: secondary pressure - system closed or secondary pressure - system dynamically flowing Fluid Temperature see pressure-/temperature diagram Operating Pressure see pressure-/temperature diagram Set Range.0-6.0 bar Nominal Pressure (H O, 0 C) PN 0 Working Pressure set pressure minus flow dependent pressure reduction:,0-6,0 bar Constant Working Pressure approx. ± 0. bar Hysteresis Difference between opening and closing pressure approx. 0. - 0.4 bar Valve Body PVC-U PP PVDF Bonnet PVC-U PP PVDF Diaphragm PTFE (EPDM diaphragm with PTFE coating on the surfaces coming into contact with the medium) Sealing EPDM

Screws stainless steel (.40) Actuation medium controlled Connection spigot end for solvent welding DIN ISO (PVC-U) fusion spigot end DIN ISO (PP) fusion spigot end DIN ISO (PVDF) backing flange DIN 50, PN 0/6, on request Flow Direction always in the direction of the arrow Mounting Position as required Colour PVC-U: grey, RAL 70 PP: grey, RAL 70 PVDF: opaque, yellowish-white Pressure Gauge Connection The pressure reducing valves can be factory fitted with a pressure gauge for neutral media. The resistance of the pressure gauge material has to be taken into consideration for other media.

Pressure/temperature diagram Operating behaviour pe = set pressure pa = working pressure pö = opening pressure ps = closing pressure pö - ps = hysteresis pa - pe = flow dependent pressure reduction Q = flow P = operating pressure T = temperature The pressure/temperature limits are applicable for the stated nominal pressures and a computed operating life factor of 5 years. These are standard values for harmless media (DIN 40), to which the valve material is resistant. For other media please refer to the ASV resistance guide. The durability of wear parts depends on the operating conditions of the application. For temperatures below 0 C (PP < +0 C) please specify the precise operating conditions of the application. The rated pressure depends on the valve size and material. For the corresponding rated pressure value of the valve, please refer to the»order table«.

Sectional drawing DMV 750 A = primary side B = secondary side = protection cap = adjustment screw = counter nut 4 = piston 5= diaphragm 6 = flat sealing ring 7 = valve seat 8 = control bore hole Applications Secondary pressure - System dynamically flowing Applications Secondary pressure - System closed pp = pump pressure pa = working pressure = Pressure Reducing Valve = stop valve = Pressure Relief Valve If the stop valve is closed, the working pressure pa rises by the amount of the closing pressure ps. pp = pump pressure pa = working pressure = Pressure Reducing Valve = stop valve = Pressure Relief Valve If the stop valve is opened, the working pressure pa drops by the amount of the opening pressure pö.

Malfunctions, possible causes, rectification Maintenance note Screw tightening torque (Nm) The specified values apply to lubricated screws. Check the tightening torque of the body screws at certain intervals in case of setting of the diaphragms and/or temperature fluctuations. Operating note Safe operation of the valve can only be ensured if it is properly installed, operated, serviced or repaired by qualified personnel according to its intended use while observing the accident prevention regulations, safety regulations, relevant standards, directives/technical regulations or codes of practice such as e.g. DIN, DIN EN, DIN ISO and DVS*. *DVS = German Welding Society The intended use includes adhering to specified limit values for pressure and temperature, as well as checking the resistance. This requires all components coming into contact with the medium to be "resistant" in accordance with the ASV resistance guide. Pressure gauge version If the valve body is equipped with a pressure gauge, do not tighten the pressure gauge with more than max. Nm. If the secondary pressure is additionally increased by the counterpressure, the pressure reducing valve DMV acts as a non-return valve. This force can lead to destruction of the valve piston. Please take into account that the material PTFE is classified as resistant against many media, however, PTFE is not diffusion tight when used as a film, e.g. for the ASV membranes. Please contact us for limit cases (nitric acid or sulfuric acid).

body PVC-U size d(mm) 75 90 pressure range DN(mm) 65 80 DN(inch) / PN(bar) 0 0 Connection sealing ident No. PVC-U spigot end DIN ISO EPDM weight 7.50 kg 74 5.00 kg body PP size d(mm) 75 90 pressure range DN(mm) 65 80 DN(inch) / PN(bar) 0 0 Connection sealing ident No. PP spigot end DIN ISO EPDM weight 76.90 kg 77.50 kg body PVDF size d(mm) 75 90 pressure range DN(mm) 65 80 DN(inch) / PN(bar) 0 0 Connection sealing ident No. PVDF spigot end DIN ISO EPDM weight 79 4.0 kg 80 7.0 kg

dimensions d(mm) DN(mm) DN(inch) 75 65 / 90 80 dimensions(mm) d h L t H N 75 84 44 65 95 90 4 60 55 40 50

Item Overview DMV 750 DN 65 position 4 5 6 7 8 9 0 4 5 7 9 0 quantity 8 designation valve body bonnet pressure spring diaphragm piston, complete spring plate pressure plate adjustment screw counter nut cap screw hexagon nut O-ring Flange O-ring screw threaded bolt pressure gauge flat sealing ring pressure spring

DMV 750, DN 80 position 4 5 6 7 9 0 4 5 6 7 8 9 0 4 5 quantity 0 8 6 designation valve body bonnet diaphragm spring plate pressure piece steel ball piston, complete O-ring O-ring protection cap adjustment screw counter nut screw screw disc threaded bolt hexagon nut Plug pressure gauge

Characteristic curves DN 65 pa = working pressure Q = flow DN 80 pa = working pressure Q = flow Configuration example The valve is set tight at 4 bar. Desired flow rate 0000 l/h, Medium H²O According to the curve, this results in the following values: set pressure pe: 4 bar; Pressure reduction: p =,8 bar; Working pressure pa = ca., bar