Model GP-1000 Series PRESSURE REDUCING VALVE. Installation & Operation Manual

Similar documents
Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Model GPR Primary Pressure Regulating Valve. Instruction Manual

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

S-COS-16 / S-COSR-16

Pressure Reducing Valve for Air A-COS-10

A-DR20-2/A-DR20-6/A-DR20-10

PN-DR. Pneumatic Direct-acting Pressure Reducing Valve for Steam and Air. Copyright 2018 by TLV CO., LTD. All rights reserved

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Direct Operated Precision Regulator Modular Style. Standard Specifications

Model 141-A Regulators

Automatic Non-freeze Valve NF6

V43 Pressure Actuated Water Regulating Valve

RS(H)20, 25 USER MANUAL

Pilot Check Valve: Metal Body Type

TITAN FLOW CONTROL, INC.

Bermad Pressure Reducing. Model: 42T

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

JAH5RG-R / JAH5RG-M JAH7RG-R / JAH7RG-M

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

3-1. Safety Relief Valve

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Model: 43T. Bermad Pressure Relief Valve

Installation Troubleshooting Maintenance Instructions Installation / Start-up

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

BUTTERFLY VALVES Series 800

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

DS05C,D,G Dial Set Pressure Regulating Valves

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Atmospheric relief valve type 1100 Installation and maintenance instructions

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

KTM 50 (DN ) Installation, maintenance and operating instructions

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Operation Manual Air Saver Unit ASV5000 Series

RD(H)20/25 Pressure-Reducing Regulator User Manual

Self Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)

TECHNICAL DATA. Page 1 of 12

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Installation & Operation Manual Proven Quality since 1892

SINGER MODEL 106/206-RPS-L&H

Pilot Operated Pressure Reducing Valve

Installation, operation & maintenance manual - original version

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Power Valve: Precision Regulator. High precision, large capacity relief regulator

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

LRS(H)4 Pressure-Reducing Regulator User Manual

Types PT and ETP Dome-Loaded Pressure Regulator Valves

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Industrial Filter. FGD series

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

D05 Pressure Regulating Valves

Pneumatic Control Valve for Steam COSPECT PN-COS-16. Manufacturer

Series V47 Temperature Actuated Modulating Valves

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Push-In Fitting Type Silencer

Installation Instructions, Pressure Regulator Series

TITAN FLOW CONTROL, INC.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Eaton Filtration, LLC

Pressure Reducing Valve for Steam Type 2333 A

Related Products: Auto Drain Valve. Model/Specifications. Model

TECHNICAL DATA CAUTION

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Coiling Tube with Twist-Proof Fitting

Hydraulic Punch Drivers

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

CA10S, CA14 and CA14S Air and Gas Traps

Eaton Filtration, LLC

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

WW-730. Pressure Sustaining/Relief Control Valve

Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Installation, Operation, and Maintenance Manual

Manual Actuated Boiler Blowdown Valves

Transcription:

Model GP-1000 Series PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully store this bulletin in a handy place. The following safety symbols are used in this manual. Warning This symbol indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. Caution This symbol indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. ( Caution may also be used to indicate other unsafe practices or risks of property damage.) Contents 1. Features 1 2. Specifications 1 3. Dimensions and Weights 2 4. Operation 3 5. Nominal Size Selection Method 5.1 Specifications selection chart 4 5.2 Safety valve setting pressure 4 5.3 Characteristics chart 4 5.4 Nominal size selection chart 5 5.5 Nominal size selection calculation formula 6 6. Installation 6.1 Example of piping 6 6.2 Precautions during installation 7 7. Operating Procedure 7.1 Precautions during operation 8 7.2 Adjustment procedures 8 8. Maintenance Procedure 8.1 Troubleshooting 9 8.2 Precautions during maintenance and inspection 10 8.3 Disassembly 10 8.4 Precautions during reassembly 11 8.5 Exploded drawing 12 After Sale Service

1. Features GP-1000 Series pressure reducing valves for steam are pilot-operated valves which can be used with confidence for small to large flow rate, in a host of applications ranging from building utilities systems, air-conditioning systems, and factory systems, etc. 2. Specifications Model GP-1000 GP-1010 GP-1000SS GP-1000H GP-1002 GP-1012 Connection Flanged Flanged Flanged Flanged JIS Rc Screw JIS Rc Screw (JIS 10K FF) (JIS 10K FF) (JIS 16K FF) (JIS 10K FF) Nominal size 15~100A 15~50A 15~100A 15~100A 15~100A 15~50A Application Steam Inlet pressure 0.1~1.0 MPa 0.1~1.6 MPa 0.1~0.5 MPa 0.05~0.9 MPa 0.05~0.9 MPa Reduced pressure 0.9~1.4 MPa 0.03~0.15 MPa 90% or less of inlet pressure (gauge pressure) Min. differential pressure 0.05 MPa Max. pressure reducing ratio 20:1 Max. temperature 220 Valve seat leakage 0.01% or less of rated flow Body Ductile cast iron Stainless steel Ductile cast iron Valve Stainless steel Valve seat Stainless steel Piston/Cylinder Brass or Bronze Stainless steel Brass or Bronze Gasket Non asbestos Body hydraulic test 2.0 MPa 3.2 MPa 1.0 MPa Stainless steel main components (piston & cylinder) are also available.(gp-1 S) All stainless steel types are also available for GP-1000. Adjusting handle types are also available for GP-1000 and GP-1010.(GP-1001,1011) Material Caution (1) Please collate with attached nameplate and specification of ordered model. Please consult factory in case they do not match each other. -1-

3. Dimensions and Weights GP-1000,1000H,1002 ( mm ) Size L H H 1 Weight(kg) 15A 150 285 64 8.0 20A 155 285 64 8.5 25A 160 300 67 10.0 32A 190 323 82 14.0 40A 190 323 82 14.5 50A 220 347 93 20.0 65A 245 357 100 30.0 80A 290 404 122 35.0 100A 330 450 144 52.5 GP-1010,1012 ( mm ) Size d L H H 1 Weight(kg) 15A Rc 1/2 150 285 64 7.0 20A Rc 3/4 155 285 64 7.0 25A Rc 1 160 300 67 8.5 32A Rc 1-1/4 190 323 82 12.0 40A Rc 1-1/2 190 323 82 12.5 50A Rc 2 220 347 93 18.0-2-

4. Operation No. Parts name 1 Body 5 Diaphragm 8 Adjusting spring 9 Adjusting screw 11 Main valve 12 Main valve seat 13 Main valve spring 14 Piston 15 Cylinder 19 Pilot valve 20 Pilot valve seat 28 Strainer 42 Inlet press. passage 43 Reduced press. Sensing port 44 Diaphragm chamber The pressure-reducing valve reduces pressure by the throttling the valve. The valve is composed of the main valve and main valve seat for throttling, and adjusting spring, diaphragm, pilot valve, and piston for pressure sensing and activation. (1) When the pressure-reducing valve is mounted correctly, releasing the compression of adjusting spring [8] allows the spring to close main valve [11] and pilot valve [19]. Slowly open the gate valve and allow the high-pressure fluid to flow in. Inlet pressure is applied to the downside of the main valve. High-pressure fluid passes through strainer [28] via inlet pressure passage [42] to also apply inlet pressure to the downside of the pilot valve. (2) Turing adjusting screw [9] clockwise compresses the spring, which flexes diaphragm [5] to open the pilot valve. (3) Inlet pressure via inlet pressure passage and pilot valve enters the upside of the piston. The pressure overrides the pressure on the downside of the main valve and the load of main valve spring[13], to open the main valve. The fluid then begins to flow from the inlet side. (4) Reduced pressure is led to diaphragm chamber [44] via reduced pressure sensing port [43]. The diaphragm receives the reduced pressure to be balanced with the adjusting spring load, and control the pilot valve travel. (5) The change of pilot valve travel changes the flow rate of fluid to the upside of the piston, and controls the main valve travel to obtain appropriate reduced pressure. -3-

5. Nominal Size Selection Method 5.1 Pressure reducing valve specification selection chart Find the intersection point of the inlet and reduced pressures. The GP-1000 series valves are suitable within range (A), (B), (C), and (D). Range(A) : GP-1000H Range(B) : GP-1000H GP-1000(1010) Range(C) : GP-1000H GP-1000(1010) GP-1002(1012) Range(D) : GP-1002(1012) 5.2 Safety valve setting pressure Reduced pressures (MPa) Safety valve setting pressure (MPa) 0.03~0.1 Reduced pressures+more than 0.05 0.1~0.4 Reduced pressures+more than 0.08 0.4~0.6 Reduced pressures+more than 0.1 0.6~0.8 Reduced pressures+more than 0.12 0.8~1.4 Reduced pressures+15% 5.3 Characteristics chart (1) Flow rate characteristics chart Shut-off pressure raise Setting pressure Reduced pressure Offset Shut-off pressure raise : 0.02 MPa or less Offset : 0.03 MPa or less (Setting pressure: 0.03~0.1 MPa) : 0.05 MPa or less (Setting pressure: 0.1~1.4 MPa) 0 5 50 Flow rate Min.adjustable flow rate 100 (%) Rated flow (2) Pressure characteristics chart Reduced pressure is set to 0.1 MPa when inlet pressure is 1.0 MPa. The chart indicates a variation in reduced pressure when the inlet pressure is changed from 1.6 to 0.3 MPa. -4-

5.4 Nominal size selection chart [Ex.1] For example, take a pressure reducing valve whose inlet pressure (P 1 ) is 0.6 MPa, reduced pressure (P 2 ) is 0.4 MPa, flow rate 800 kg/h. First, find the point of intersection (A) of inlet pressure 0.6 MPa and reduced pressure 0.4 MPa. Vertically proceed from point (A) to come across the flow rate 800 kg/h, and regard this point as (B). Point (B) is between nominal sizes 40A and 50A. Select the larger nominal size 50A. [Ex.2] For example, take a pressure reducing valve whose inlet pressure (P 1 ) is 0.8 MPa, reduced pressure (P 2 ) is 0.05 MPa, flow rate 600 kg/h. First, find the point of intersection (C) of inlet pressure 0.8 MPa and the diagonal line. Move leftward down the diagonal line to intersection point (D) where the diagonals line intersect with the reduced pressure 0.05 MPa. Vertically proceed from point (D) to come across the flow rate 600 kg/h, and regard this point as (E). Point (E) is between nominal sizes 32A and 40A. Select the larger nominal size 40A. -5-

5.5 Nominal size selection calculation formula The appropriate nominal size can be calculated by obtaining the Cv value for the operating conditions in question, as shown below. Cv value calculation formula P 2 > P 2 1 Cv = 138 Wk ΔP(P 1 + P2) W: Max. steam flow rate [kg/h] P 1 : Inlet pressure [MPa A] P 2 : Reduced pressure [MPa A] ΔP: P 1 -P 2 [MPa] P P2< 2 1 Wk Cv = 120P1 k: 1+0.0013 {super-heated steam temp.[ ]-saturated steam temp.[ ]} Rated Cv value table (When Cv correction coefficient is C=1) Nominal size 15A 20A 25A 32A 40A 50A 65A 80A 100A Rated Cv value 1 2.3 4 6.5 9 16 25 36 64 Correction of rated Cv value If the inlet pressure exceeds 0.7 MPa, and the pressure reducing is 0.4 MPa or less, find the appropriate correction coefficient C using chart below, and multiply the rated Cv value, and obtain the corrected Cv value. C :Correction coefficient 1.0 0.9 ( ロ ) 0.8 0.7 0.6 0.5 0.4 0.7 ( イ ) 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 P 1 :Inlet pressure MPa 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 P2 :Reduced pressure MPa 1.6 [Ex.] Take a pressure reducing valve whose inlet pressure is 0.8 MPa, reduced pressure is 0.05 MPa. Find the inlet and reduced pressure intersection point (A) at the left chart, then draw a horizontal line in the leftward direction to point (B) which indicates a correction coefficient of 0.85. For a nominal size of 25A, the corrected Cv value would be calculated as follows: 4(rated Cv value) 0.85(correction coefficient) = 3.4 6. Installation 6.1 Example of piping -6-

6.2 Precautions during installation Warning (1) Because of heavy weight, hold the valve with lifting equipment while piping. Refer to 3. Dimensions and weights table for the valve weight. Failure to do so may result in injury due to dropping the valve. (2) In case installing safety valve as safety device at outlet side, joint relief pipe at outlet of safety valve and guide it to safety place where steam can relief out. Failure to do so may result in burns. Caution (1) Do not disassemble the valve unreasonably. Disassembling the valve at your discretion may affect the original performance. (2) Remove foreign matter and scales from the lines before connecting the valve. Failure to do so may prevent the valve from functioning correctly. (3) Install a strainer (Recommendation: 100-mesh or close) at the valve inlet side. Failure to do so may hamper correct pressure control, which affects the original performance. (4) Install a safety valve at the valve outlet sides as safety device for equipment. Failure to do so prevents problem identification, resulting in equipment damage. (5) Install a pressure gauge at both the inlet and outlet sides of the valve. Failure to do so may hamper correct pressure adjustment. (6) Install a steam trap to the inlet sides of the valve to prevent drainage problems. Failure to do so may result in drainage problem, affecting the original performance. (7) When installing quick open and close valves, such as a solenoid valve, install it at inlet side as much as possible, and secure at least 3 m from the valve. Failure to do so may result in malfunction or drastically shortened service life. (8) When pressure reducing in two stages, secure at least 3 m between the valves. Failure to do so may result in malfunction, affecting the original performance. (9) Install the valve in proper direction of the fluid flow. Failure to do so may affect the original performance. (10) Do not apply excessive load, torque or vibration to the valve. Doing so may result in malfunction or drastically shortened service life. (1) Install the valve perpendicularly to horizontal lines. (2) Provide the by-pass line. (See 6.1 Example of piping) (3) When the pressure-reducing ratio is large, install a reducer to keep the flow velocity in the pipe below 30 m/s or less. (4) Provide space on the top and bottom of the valve so that the valve can be easily disassembled and inspected. (See Fig.1) Fig.1 (mm) Nominal size A B 15A 20A 315 125 25A 135 32A 40A 335 155 50A 345 175 65A 355 190 80A 375 225 100A 395 265-7-

7. Operating Procedure 7.1 Precautions during operation Warning (1) Do not touch the valve directly with bare hands. Doing so may result in burns. (2) Before flow the steam in pipe line, make sure steam can flow without any dangerous at the end of pipe line and pipe line is connected tightly. In case steam blow off, it may result in burns. Caution (1)Close the stop valves before and after the pressure reducing valve, and remove all foreign matter and scales via the by-pass line before operation. And, open each stop valve slowly. Failure to do so may prevent the valve from functioning correctly. And, It may cause hunting, water hammer, etc., resulting in damage to the valve and other equipment when the stop valve is opened quickly. (2)Secondary pressure at by-pass line must be lower than set pressure. Safety valve blows in case secondary pressure at by-pass line becomes higher than set pressure. (3)When adjusting pressure, slowly turn the adjusting screw Incorrect adjustment may cause hunting, water hammer, etc., resulting in damage to the valve and other equipment. (4)Remove condensate completely from the line, and close the stop valves before and after the valve when not using it for long periods of times. Rust generated in the valves and lines may cause malfunction. (5)For the model with handle, be sure to operate the handle manually and turn it while pushing down. At this time, do not turn with too much torque or do not turn excessively. Rust generated in the valves and lines may cause malfunction. 7.2 Adjustment procedures Follow the steps below, and slowly turn the adjusting screw to set pressure. Incorrect adjustment may cause hunting, water hammer, etc., resulting in damage to the valve and other equipment. (1) Close the stop valve at inlet and outlet side of the pressure reducing valve, and taking sufficient time not to blow the safety valve, blow off the fluid to remove foreign matter via the by-pass line. After blowing, close the by-pass line stop valve. (2) Slowly open the stop valve at the inlet side of the pressure reducing valve, and adjust the travel of the stop valve at the outlet side of the pressure reducing valve so that a little fluid flows. (3) Loosen the lock nut, and slowly turn the adjusting screw to achieve the desired pressure (clockwise to increase, counterclockwise to reduce) while observing the pressure gauge on the outlet side. While adjusting the pressure, push down and turn the handle slowly because the handle is locked in normal position and look at the secondary side of pressure gauge closely. (Secondary pressure rises by turning the handle in clockwise and descends in counterclockwise). (4) Slowly open the stop valve at the outlet of the pressure reducing valve, and readjust the desired pressure. (5) After adjustment, tighten the lock nut. For the model with handle, handle is pulled up and locked by releasing hold. If it is not locked, turn the handle to left and right then release it. -8-

8. Maintenance Procedure 8.1 Troubleshooting Problem Cause Solution Pressure does not reach the desired value. Reduced pressure raises above than the specified value. Abnormal noise is heard. 1. Incorrect pressure is being used. 2. Strainer [28] is clogged. 3. Foreign matter exists between piston [14] and cylinder [15]. 4. Piston ring [16] is damaged. 5. Nominal size is too small for the specifications. 6. Pressure is not adjusted correctly. 7. Strainer installed before pressure reducing valve is clogged. 8. Pressure gauge is faulty. 1. Foreign matter exists between main valve [11] and main valve seat [12], or scratches exist. 2. Foreign matter exists between pilot valve [19] and pilot valve seat [20], or scratches exist. 3. Foreign matter exists between piston [14] and cylinder [15]. 4. Trap is not provided for dead-end line. 5. By-pass valve is leaking. 6. Diaphragm [5] is damaged. 1. Nominal size is too large for the specifications. 2. Pressure reducing ratio is too large. 3. Drainage problem is caused. 4. An abrupt OPEN/CLOSE valve is located too close to the pressure reducing valve. 5. Outlet pipe is too small. 1. Correct the pressure. 2. Disassemble and clean the strainer. 3. Disassemble and remove the foreign matter. When any scratches are identified, polish them away using a paper. Change the parts if scratches still exist after polishing. 4. Replace the piston ring. 5. Change the nominal size appro-priately. 6. Observe the adjustment procedures and readjust pressure. 7. Disassemble and clean it. 8. Replace it. 1. Disassemble and remove the foreign matter. When any scratches are identified, lap the main valve and main valve seat. Change the parts if scratches still exist after lapping. 2. Disassemble the pilot valve as-sembly, and clean or replace it. 3. Disassemble and remove the foreign matter. When any scratches are identified, polish them away using a paper. Change the parts if scratches still exist after polishing. 4. Install a trap. 5. Repair or replace it. 6. Replace the diaphragm. 1. Change the nominal size appro-priately. 2. Reduce pressure in two stages. 3. Install a trap. 4. Allow as much as possible between the valves. 5. Select a pipe size that will produce a flow velocity of 30m/s or less. Foreign matter and scales in a pipe may cause most of problems of pressure reducing valve. Be careful sufficiently to foreign matter in a pipe. Phenomenon alike valve trouble may happen by fault of pressure gauge, fluid leakage from by-pass valve, forgetting to close the by-pass valve, clogging strainer, and etc. First, check the said particulars before above troubleshooting. Consult factory when cannot make a judgement whether parts need replacement or not. -9-

8.2 Precautions during maintenance and inspection Warning (1)Completely discharge internal pressure from the valves, lines, and equipment, and cool the valve down to a level where you can touch it with bare hands before disassembly and inspection. Failure to do so may result in injury or burns due to residual pressure or spillage around the valve. Caution (1)In order to maintain original performance and function, examine daily and personal inspection. And, periodical inspection must be examined according to the regulations of every kind. For general users, request to specialized dealer or manufacture. (2)Pressure reducing valve shall be disassembled and inspected by qualified person or manufacture. Request the treatment to specialized dealer or manufacture in case of any problems. (3)While disassembly, drain flow out from the valve, so catch it by container. And release steam completely before disassembling. In case of no container for drain, it makes dirty surrounding the valve. (4)Close the stop valves before and after the pressure reducing valve, and remove all foreign matter and scales via the by-pass line before operation. Failure to do so may prevent the valve from functioning correctly. (5)When adjusting pressure, slowly turn the adjusting screw. Incorrect adjustment may cause hunting, water hammer, etc., resulting in damage to the valve and other equipment. (6)Remove condensate completely from the line, and close the stop valves before and after the valve when not using it for long periods of times. Rust generated in the valves and lines may cause malfunction. (7)In case of no operation for a long period of time, perform operating exam before start operation again. Request the treatment to specialized dealer or manufacture in case of any problems. 8.3 Disassembly Be sure that the stop valves at inlet and outlet side of pressure reducing valve is closed and all internal pressure and condensate have discharged before disassembling the valve. (1) Pilot valve 1. Loosen the lock nut [10] and turn the adjusting screw [9] to release the spring [8] (no compression). For the model with handle, turn the handle in counterclockwise while pushing down in order to change the adjusting spring into free position. 2. Remove the bolt [33] of the spring chamber [4]. Remove the spring chamber, spring, top spring plate [6], bottom spring plate [7], and diaphragm [5]. For the model with handle, remove the handle and spring chamber by one since they cannot disassemble. 3. Remove the pilot valve assembly [19], [20] using a ring spanner or socket wrench (nominal size 22) (2) Piston 1. Remove the bolt [34] of the top cover [2] and the top cover. Pick up the spindle [18], and remove the piston ring [16] and the inner ring [17]. (3) Main valve 1. Remove the bolt [35] of the bottom cover [3]. Remove the bottom cover, main valve spring [13], and main valve [11]. -10-

8.4 Precautions during disassembly Caution (1) Check that there is no damage and scratches on the main valve, main valve seat, pilot valve, and pilot valve seat. Any scratches at sealing surface lead to increase in secondary pressure. When any scratches are identified at main valve and seat, polish them away. And, change the parts if scratches still exist after polishing. Also, in case any scratches are identified at pilot valve and pilot valve seat, change into pilot valve assembly. (2) Move the sliding section (pilot valve, piston, etc.) two to three times and confirm they move smoothly. If the sliding parts do not move correctly, it may cause failure problems. (Working not correctly). (3) Replace gaskets with new ones when reassembling. If the gasket is used for a long time, it may cause steam leakage problem. (4) Assemble in the reverse order of Disassembly. And tighten the bolts evenly. Assemble the valve due to the order. Failure to do so may lead to not assemble correctly. And if the hexagon bolts are not screwed correctly, it may cause steam leakage problem. -11-

8.5 Exploded drawing The parts from spring plate to top become as shown in the following figure for the model with Parts with in the flame are consumable. Please contact us for purchase of these consumable parts. Name of parts Replace period 5 Diaphragm 2 years 16 Piston ring 3 years 17 Inner ring 3 years 19 20 Pilot valve assembly 5 years 24 Gasket 5 years 26 27 Gasket 2 years 28 Strainer 5 years 30 Gasket 2 years Diaphragm [5] and piston ring [16] are used two pieces for GP-1002 and GP-1012. Note (*): Apply a liquid sealant for heat and steam resistant (Recommendation: SOLVEST 110) to the sealing surface of the diaphragm bottom and the top cover. -12-

Warranty Information 1. Limited warranty This product has been manufactured using highly-advanced techniques and subjected to strict quality control. Please be sure to use the product in accordance with instructions on the manual and the label attached to it. Yoshitake warrants the product to be free from any defects in material and workmanship under normal usage for a period of one year from the date of receipt by the original user, but no longer than 24 months from the date of shipment from Yoshitake s factory. 2. Parts supply after product discontinuation This product may be subject to discontinuation or change for improvement without any prior notice. After the discontinuation of the product, Yoshitake supplies the repair parts for 5 years otherwise individually agreed. 3. This warranty does not cover the damage due to any of below: (1) Valve seat leakage or malfunction caused by foreign substances inside piping. (2) Improper handling or misuse. (3) Improper supply conditions such as abnormal water pressure/quality. (4) Water scale or freezing. (5) Trouble with power/air supply. (6) Any alteration made by other than Yoshitake. (7) Use under severe conditions deviating from the design specifications. (8) Fire, flood, earthquake, thunder and other natural disasters. (9) Consumable parts such as O-ring, gasket, diaphragm and etc. Yoshitake is not liable for any damage or loss caused by malfunction or defect of the product. INTERNATIONAL DEPT. 7-3, Futanocho, Mizuho, Nagoya, Aichi, 467-0861, Japan Phone: +81-52-881-7199 Fax: +81-52-881-7201 E-mail: Intntl@yoshitake.co.jp 2009.9 PDD-046c