MODEL CALIBRATION GAS DELIVERY SYSTEM

Similar documents
RK-IR Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RGC-IR Remote Gas Calibrator for IR400

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

PERSONAL AIR BREATHING UNIT

Model ASSEMBLY and OPERATING INSTRUCTIONS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

RAM 4021 Operation Manual

User s Guide. CO2 Controller for miniature incubators

Yoke Block Instruction Manual

User s Guide. CO2 & O2 Controller for miniature incubators

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Please Do Not Return This Product To The Store!

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Yoke Block Instruction Manual

Nitrogen Supply System

453 Series Steam Heated Vaporizing Regulator

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

GAS FRYER Instruction Manual Model #5099NS

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Airtester HP for compressed air according to EN 12021

Pressure Relief Valve Instruction Manual

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

G7S Hand Pump Owner s Manual

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

AND OPERATION INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

D Series Air and Water Kit Part# 02550

TactAir PCP Fill Kit/Adapter. Operation Manual

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

CF-SERIES HIGH FLOW REGULATORS

10% OFF HHPROMO. Havahart Spray Away Animal Repellent Sprinkler Owner s Manual Model #5266. Caught a critter in the act?

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

J Air and Water Kit Instructions Part# 02584

4-in-1 Professional Inflator Kit

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Installation Instructions Air Compressor Part # 2780, 2781

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Advanced Test Equipment Rentals ATEC (2832)

PBT1100 POWER BANDING TOOL

User Instruction Manual

! Warning, refer to accompanying documents.

AUTO PUMP STATUS CENTER

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

RAM Operation Manual

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

UNIVERSAL TUBE HOLDER SYSTEM

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Techcon Systems TS1254 Pressure Pot

Portable Compressed CO 2 Regulator

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Cylinder Tilt Saddle Instruction Manual

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

BS Series Basket Strainer

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Model No Product Name Handpiece Only Complete System

Birdie Ball Game Instruction Manual Model #7756- Birdie Ball Insert Model #7757-Alley and Tub

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

RAM 4021-DPX Operation Manual

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

UNIVERSAL MASK TEST SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS

NTO-200 Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

Pressure Injection Cell Operator s Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Model 6202 Reduced Oxygen Breathing Device 2

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Installation Instructions JATCO Environmental Protection Tank Model J-7000

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

MODEL RP050BMST RESPIRATORY PROTECTOR MANUAL

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Installation & Instruction Manual For Portable Series R.O. units:

Transcription:

MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM

Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 1200-26 Model 26 Calibration Gas Delivery System The instructions are effective for the above models as of October 16, 1996 Instruction Manual Part Number: T15001 IM22/1096

1. FRMC APPROVAL The Model 26 (1200-26) Calibration Gas Delivery System and Methane calibration gas cylinders are approved for calibration of Factory Mutual Research Corporation (FRMC) Approved Sierra Monitor Combustible Gas sensors. 2. PRODUCT DESCRIPTION The Calibration Gas Delivery System consists of a disposible pressure vessel containing calibration gas and a non-disposable pressure and flow regulating system. The hardware is designed to maintain a low flow of gas to increase the life of the disposable cylinder. Calibration gas cylinders can be ordered from Sierra Monitor Corporation in any concentration of combustible gas, carbon monoxide gas or oxygen mixed in air. Each cylinder is labelled with the gas content. A plastic carrying case is also available. 3. OPERATION INSTRUCTIONS 3.1. CYLINDER INSTALLATION AND FLOW ADJUSTMENT - Turn the regulator adjust (brass knob on top of calibrator) counter clock-wise two turns to be sure valve is off before gas cylinder is installed. - Turn flow meter off clock-wise. - Press the connector release tab on the cylinder valve to position it to receive the connector to the calibrator unit. Press the male connector on the blue gas tube firmly into the cylinder valve until the click indicates that the fitting has seated. (Moistening the O-ring may facilitate insertion). MODEL 1200-26 GAS CALIB SYSTEM 9.0 INCHES DISPOSABLE CYLINDER, (2 SUPPLIED) CONNECTOR RELEASE TAB CONNECTOR HOSE PRESSURE GUAGE DELIVERY TUBE REGULATOR ADJUST FLOW METER WITH FINE ADJUST FIGURE 1: OUTLINE DRAWING Model 1200-26 Calibration Gas Delivery System (10/96) Page: 1

- Install the cylinder into the bracket on the side of the monitor. - At this time the cylinder pressure can be read on the gauge on the top of the calibrator. New cylinders are shipped packed at a maximum of 150 psi. - Turn the pressure regulator adjust clockwise to provide pressure to the flow meter. - Adjust the flow meter flow fine adjust to provide a flow rate as specified below and in the specific gas sensor module instruction manual. (If the float is not stable, turn the regulator adjust clockwise to provide more back pressure to the flow meter. SAFETY NOTE: Removal of the blue tube from the cylinder while the cylinder is pressurized will cause the tube to pop out with a loud noise. Point the cylinder away from personnel prior to pressing the release tab. 3.2. CALIBRATION - The fitting on the end of the delivery tube is different for each sensor package. Follow the calibration instruction for the specific device as outlined in the respective monitor instruction manual. - Remember to turn the flow meter off to save gas at any time calibration is interrupted. - When calibration is complete, disconnect the cylinder from the blue tube by pressing the quick release tab. Recommended Recommended Flow Model/Product Calib. Filter Rate Time 20X/200X 22048 50 0.5 min. 2400 22048 50 0.5 min. 4101-02 5358-00/01 100 2-3 min. 4101-04 5358-00/01 150 2-3 min. 4101-07 5358-00/01 300 2-3 min. 4101-16 5358-00/01 300 2-3 min. 5100-02 5358-00 100 2-3 min. 5100-04 5358-00 150 2-3 min. 5100-07 5358-00 300 2-3 min. TABLE 1: CALIBRATION ADAPTERS Page: 2 Model 1200-26 Calibration Gas Delivery System (10/96)

3. SPECIFICATIONS CALIBRATOR DIMENSIONS: WEIGHT: STORAGE TEMPERATURE: 4 X 7 X 3 Inches (10.2 x 17.8 x 7.6 cm) (excluding cylinder) 2.0 pounds (1.2 Kg) (excluding cylinder) -40 o F to +131 o F (-40 o C to +55 o C OPERATION TEMPERATURE: +37 o F to +110 o F (+3 o C to +44 o C) CYLINDER MATERIAL: USE: BURST: TEST: PRESSURE: REGULATIONS: Aluminum Non-Refillable Minimum burst 600 psi Leak Test 225 psi Shipping Pressure: Max 150 psi Cylinders prepared and labeled in accordance with Federal (DOT) Regulation 39, and Title 49 CFR (DOT Registration No. M-1083) Model 1200-26 Calibration Gas Delivery System (10/96) Page: 3

SPARE PARTS Calibration Gas Cylinders 1290-01 Gas Cylinder - Air (20.9% Oxygen) 1290-02 Gas Cylinder - Methane 50% L.E.L. 1290-03 Gas Cylinder - Methane 5,000 PPM 1290-04 Gas Cylinder - Methane 1,000 PPM 1290-05 Gas Cylinder - Carbon Monoxide 100 PPM 1290-06 Gas Cylinder - Hydrogen 50% L.E.L. 1290-07 Gas Cylinder - Hydrogen 500 PPM 1290-08 Gas Cylinder - Carbon Monoxide 25 PPM 1290-98 Gas Cylinder - Non Standard Mixture 1290-99 Gas Cylinder - Non Standard Gas Type Calibration Options & Accessories 5358-00 Calibration Adapter - Direct, Magnetic 5358-01 Calibration Adapter - Direct, Standard 5360-00 Calibration Gas Delivery Fitting - Fixed SPB32064 Plastic Carry Case for 1200-26 SPB33048 Delivery Tube/Fitting for 1200-26 SPB64011 Delivery Tube, 3 foot SPB69036 O-Ring for 1200-26 (5 pack) Note: Only 1290-02 (Methane 50% L.E.L.) is FMRC Approved LIMITED WARRANTY SIERRA MONITOR CORPORATION warrants its products to be free from defects in workmanship or material under normal use and service for one year after date of shipment. SMC will repair or replace without charge any equipment found to be defective during the warranty period. Final determination of the nature and responsibility for defective or damaged equipment will be made by SMC personnel. All warranties hereunder are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without SMC approval or which have been subjected to accident, improper maintenance, installation or application, or on which original identification marks have been removed or altered. This Limited Warranty also will not apply to interconnecting cables or wires, consumables (ie. calibration gases, batteries), nor to any damage resulting from battery leakage. In all cases SMC s responsibility and liability under this warranty shall be limited to the cost of the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty provision and compliance with such instruction shall be a condition of this warranty. Except for the express warranty stated above, SMC disclaims all warranties with regard to the products sold hereunder including all implied warranties of merchantability and fitness and the express warranties stated herein are in lieu of all obligations or liabilities on the part of SMC for damages including but not limited to consequential damages arising out of/or in connection with the use or performance of the product. Page: 4 Model 1200-26 Calibration Gas Delivery System (10/96)