911A Summa Canister Sampler

Similar documents
AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

EAS Basic Soil Gas Sampler

STANDARD OPERATING PROCEDURES

FAULT CODE TROUBLESHOOTING INDEX

STANDARD OPERATING PROCEDURES

Rejuvenation Instructions

Sedan Range. Evaporative Loss System Check Clarified Procedure

Operating Instructions

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Inert Air (N2) Systems Manual

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Setup Guide for your HVO Naked Drone

STANDARD OPERATING PROCEDURES

4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL

Piped Air SCBA Refilling System Standard

IMPORTANT SAFETY NOTICE

Gas Diluter Portable Gas Dilution System User s Manual

BioPak 240 Revolution

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Thermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities

Cover.qxd 1/10/05 10:30 AM Page 2. user manual. diablopaintball.com

TECHNICAL DATA. Q = C v P S

Universal Valve Company Inc

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

KJ4000 Operating Instructions & Parts Manual NSN

Universal Valve Company Inc

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Touch Screen Guide. OG-1500 and OG Part # T011

User Manual for the Mars Calibration Bench

User Instruction Manual

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Installation of Your SprayMaster System

Equipment Operating Procedure Glove Box

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

Pressure is our Business

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

VMC - Hydraulic Counterbalance - Pressure Switch - Replacement

Product Information News

HYDRAULIC CYLINDER TEST

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Budget Range Operators Handbook

TECHNICAL DATA. Q = C v P S

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

MEDICAL AIR Effective date: 02/80 MAINTENANCE Revision date : 08/12

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

TABLE OF CONTENT IMPORTANT HPA AIR TANK SAFETY INSTRUCTIONS AND GUIDELINES RYSE ON/OFF ASA GETTING STARTED O-RING LIST SCREW LIST MICRO SQ BOARD

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Training. Testor Training Manual

Standard Operating Procedure

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

The Discussion of this exercise covers the following points:

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

user manual .68 CALIBER ELECTRONIC PAINTBALL MARKER Meets or exceeds ASTM standards.

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Inverse Proportional Pressure-Relief Cart., Size 2 4

VERTICAL AIR COMPRESSORS

BUBBLER CONTROL SYSTEM

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Residential Pressure Booster Systems

Instruction Manual VCG-6

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Winter Shut Down Procedure

TOOL BOX 031- SERVICE OF CARTRIDGE EXTINGUISHERS

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Time-Delay Electropneumatic Applications

36H SERIES Combination Gas Valve

Inverse Prop. Pressure-Relief Cart., Size 2 4

BioPak 240 Revolution

ANALOX O2 PORTABLE OPERATORS MANUAL

APPS-160 Gen 2 User Manual

Operating Procedure TITON SUBSEA BOLT TENSIONER

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

PERFORM Operating Document

Glove Box Installation Manual

Operator: Save these instructions for future use!

SCS Field Revision No. 1.0 June 2001 STANDARD OPERATING PROCEDURE (SOP) FOR FIELD OPERATION OF THE SEQUENTIAL CYCLONE SAMPLER (SCS)

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Lesson 6: Flow Control Valves

Operation and Maintenance of the EPV200 Portable Ventilator

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Auto EVAP Quick Start Guide

O2 Portable. User Manual

Transcription:

North Carolina Department of Environment & Natural Resources Division of Air Quality 911A Canister Sampler Page 1 of 7 Standard Operating Procedure for 911A Summa Canister Sampler 1.0 General Information Name: 911 Canister Sampler Manufacturer: Xonteck Inc., 187 Tank Farm Road, Suite 140, San Luis Obispo, CA 93401 Users: Monitoring site operators and Electronics Technician Karen Clevenger, Environmental Technician Pernell Judd, Electronics Technician Jim Bowyer, LAB Supervisor Donald D. Redmond, Jr., Ambient Monitoring Section Chief

Standard Operating Procedure 911A Summa Canister Sampler 911A Canister Sampler Page 2 of 7 2. Specifications: Provides a constant flow of sample gas into a Summa canister Has programmable timer for scheduling sample collection times. Runs on 12V DC power source. 3. General Operation: a) Set-up and Leak Check. 1. No flow check is needed. The sampler flow is set when the instrument is cleaned and certified. 2. Attach the Summa canister to bulkhead Outlet fitting. (Do not open the canister valve at this time.) 3. With the power switch on and the valve switch in the closed position (oncc these switches are in these positions they should never be moved), turn on the pump by pushing the button on the timer (hand symbol). The pump will start immediately followed by a loud click from the valve opening. 4. Allow the pressure to increase to 10-15 psi. (Be careful not exceed the top range of the gauge as this may damage the gauge and cause the solenoid valve to stick.) Turn the pump off. Note the exact pressure and time. 5. Verify that the pressure does not drop by more than 1 psi over 15 minutes. 6. If the leak test fails, try to fix the leak by tightening fittings and retest. 7. If the leak test passes, slowly open the summa canister valve. Opening quickly may damage the gauge and cause the solenoid to stick. 8. The canister is ready for sampling. b) Set Timer 1. Push the "Reset" button using a pointed object. Do not push too hard or the button will be damaged. ' 2. Push and hold the "Clock" button, push the "Day" button as required to advance to the current day of the week. 3. Push and hold the "Clock" button, push the "h+" button as required to advance to the current hour. Time is set and displayed in Military Time format (0:00 to 23:59 hours). The hour should be set to the correct local time either Standard Time or Daylight Saving Time depending on the time of year. 4. Push and hold the "Clock" button, push the "m+" button as required to advance to the current minute. c) Program sample timer: 1. Verify that the displayed time and day are correct, adjust per above if required. 2. Push the "Timer" button, TIMER 1 ON is displayed. Use the "h+" and "m+"

911A Canister Sampler Page 3 of 7 buttons to set the time when sampling will begin. Use the "Day" button to set the day of the week when sampling will begin. Four sampling day modes are available: any single day of the week; weekdays (Monday thru Friday); weekends (Saturday and Sunday); days Monday thu Saturday. Push the "Day" button repeatedly to view the different modes. 3. Push the "Timer" button, TIMER 1 Off is displayed. Use the "h+" and "m+" buttons to set the time when sampling will end. Use the "Day" button to set the day of the week when sampling will end. 4. Push the "Clock" button to save the program and return to the day and time display. 5. Repeat steps 2 thru 4 to set additional sampling times if required. Six on/off programs. 6. Programs can be viewed by pressing the "Timer" button repeatedly to advance through the six programs. Return to the day and time display by pressing the "Clock" button. 7. The "Timer button can also be used to select a program for editing. Unwanted programs can be removed by advancing the hour past 23 and minute past 59. 8. When in the programming mode the timer will revert to the day and time display after one minute of inactivity. d) Removing the sample 1. Close the canister valve (two finger tight only). 2. Remove the canister from the 911 sampler. Addenda: Addendum to SOP for 911A Summa Canister Sampler for RMESI 911A Timer Set-up and programming Addendum to SOP for 911A Summa Canister Sampler for using it with a COC form..

911A Canister Sampler Page 4 of 7 Addendum to SOP for 911A Summa Canister Sampler for RMESI 911A Timer Set-up and programming Set time and day 1. Push the "Reset" button using a pointed object. Do not push too hard or the button will be damaged. ' 2. Push and hold the "Clock" button, push the "Day" button as required to advance to the current day of the week. 3. Push and hold the "Clock" button, push the "h+" button as required to advance to the current hour. Time is set and displayed in Military Time format (0 to 23:59 hours). The hour should be set to the correct local time either Standard Time or Daylight Saving Time depending on the time of year. 4. Push and hold the "Clock" button, push the "m+" button as required to advance to the current minute. Program sampling time(s) 1. Verify that the displayed time and day are correct, adjust per above if required. 2. Push the "Timer" button, TIMER 1 ON is displayed. Use the "h+" and "m+" buttons to set the time when sampling will begin. Use the "Day" button to set the day of the week when sampling will begin. Four sampling day modes are available: any single day of the week; weekdays (Monday thru Friday); weekends (Saturday and Sunday); days Monday thru Saturday. Push the "Day" button repeatedly to view the different modes. 3. Push the "Timer" button, TIMER 1 Off is displayed. Use the "h+" and "m+" buttons to set the time when sampling will end. Use the "Day" button to set the day of the week when sampling will end. 4. Push the "Clock" button to save the program and return to the day and time display. 5. Repeat steps 2 thru 4 to set additional sampling times if required. Six on/off programs are available. Programs can be viewed by pressing the "Timer" button repeatedly to advance through the six programs. Return to the day and time display by pressing the "Clock" button. The "Timer button can also be used to select a program for editing. Unwanted programs can be removed by advancing the hour past 23 and minute past 59. When in the programming mode the timer will revert to the day and time display after one minute of inactivity.

911 SOP Revision 5 3/21/14 Page 5 of 7 Operation 1. Set clock time and day. 2. Program sampling time(s). The "Hand" button is used to manually start and stop sampling. Push for on and push again for off. Sampling status is displayed as "ON" or "OFF". ' Inspect the battery terminals for corrosion periodically, replace as required. An alkaline "AAA" battery is used and should last for several years.

911 SOP Revision 5 3/21/14 Page 6 of 7

911 SOP Revision 5 3/21/14 Page 7 of 7 Addendum to SOP for 911A Summa Canister Sampler for using it with a COC form. Section numbers refer to sections in SOP for 911A Summa Canister Sampler where directions below replace those sections when using a COC form. 3. General Operation: a) Set-up and Leak Check. 9. Break the tamper-proof seal on the canister and record your initials, date and time in the Pre-Sample COC Broken By/ &Time (Field) box on the COC form. 10. Attach the Summa canister to bulkhead Outlet fitting. (Do not open the canister valve at this time.) 11. With the power switch on and the valve switch in the closed position (oncc these switches are in these positions they should never be moved), turn on the pump by pushing the button on the timer (hand symbol). The pump will start immediately followed by a loud click from the valve opening. 12. Allow the pressure to increase to 10-15 psi. (Be careful not exceed the top range of the gauge as this may damage the gauge and cause the solenoid valve to stick.) Turn the pump off. Note the exact pressure and time. 13. Record the Sampling Information on the COC form and the canister tag. 14. Verify that the pressure does not drop by more than 1 psi over 15 minutes. 15. If the leak test fails, try to fix the leak by tightening fittings and retest. 16. If the leak test passes, check the leak check box on the COC form and slowly open the summa canister valve. Opening quickly may damage the gauge and cause the solenoid to stick. 17. Record the vacuum/pressure on the COC form in the Field Verif. box. It should be close to the Lab Reading : -29 to -28 inches Hg. If not, the can has leaked, use another can if available. 18. The canister is ready for sampling. c) No changes d) Removing the sample 3. Record the pressure on the COC form in the Canister pressure Field Reading box and on the cylinder tag. If the pressure reading is significantly lower or higher than usual, inform the LAB Electronics Technician who may advise checking and adjusting the flow. 4. Close the canister valve (two finger tight only). 5. Seal the valve with a tamper-proof seal and on the COC form record its number in the Post-Sample COC No. box. Record your initials date and time in the COC Sealed By/ & Time (Field) box. 6. Place COC form in top of canister and place in shipping box.