SM Models Manual Control

Similar documents
SM Models Manual Control

SP/ST/SA Models Pulse-input and Analog-input Control

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Operating Instructions Model and Hydrostatic Test Pump

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Operating Instructions Models and Hydrostatic Test Pumps

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

P/N: IND-DP Industrial Drum Pumps

ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

LIQUID PUMPS ACCESSORIES OVERVIEW

Proportional Pressure-Relief Cartridge Valve, Size 2...4

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Pressure Sensing Valve - Model 4023

ELADOS EDP L Diaphragm Metering Pump Type

Operating Instructions Model and Hydrostatic Test Pump

Inverse Prop. Pressure-Relief Cart., Size 2 4

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Pneumatic Powered - Plunger Pumps

EC-064.indd /12/21 16:16:52

VACUUM REGULATORS CONTENTS

Operating Instructions Models and Hydrostatic Test Pumps

Process Pump. PAF3000 Series/PAF5000 Series

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Models: C62/63/64-A/D

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

30T A/Manual Hydraulic Shop Press

Suggested Installation & Operating Instructions for Sidewinder Pumps

Operating Instructions

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

High-performance submersible pressure transmitter For level measurement Model LH-10

Tightness controls TC 1 3 and TC 4

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

2 I All-Flo Pump Co.

ABRASIVE REGULATOR II

OPERATING INSTRUCTIONS MANUAL FOR H SERIES DOSING PUMP

ABRASIVE REGULATOR II

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Low-pressure diaphragm pumps for product feeding Feeding

High-performance submersible pressure transmitter For level measurement Model LH-10

Glass tube flowmeters Series 2000

Operating Instructions

SIHI LPH-X - Liquid Ring Compressors

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Air Saving Valve. Pressure Valve Flow Valve

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

GRUNDFOS ALLDOS INSTRUCTIONS DMI 208. Dosing pump. Installation and operating instructions

Liquid ring vacuum pumps single-stage

Pressure Injection Cell Operator s Manual

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

LMU100/200 Series. Standard Specifications

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Model DE-1, VDE-1 and DE-2 Air Release Heads

Technical Information Conducal CLY421

Inverse Proportional Pressure-Relief Cart., Size 2 4

Process Pump. Series PAF3000/Series PAF5000

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Techcon Systems TS1254 Pressure Pot

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

ATS430 turbidity sensor Retractable insertion assembly

Dual position solenoid valve Type ICSH 25-80

ALF400 to 900, ALT-5/-9

Autocalibration Systems For In Situ Oxygen Analyzers

KEG PUMP. Range of Electric Keg Pumps

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

HumiSys HF High Flow RH Generator

ISOMEGA BLADDER PUMPS

Liquid ring vacuum pumps in compact design

Booster Regulator/Air Tank

ALF400 to 900, ALT-5/-9

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

4/2 way Pneumatic Solenoid Valve

Standard Specifications

Schroeder Check Test Point System

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

MINI DIAPHRAGM VACUUM PUMPS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Operation Manual Air Saver Unit ASV5000 Series

Power Valve: Precision Regulator. High precision, large capacity relief regulator

BERMAD Fire Protection Hydraulic Control Valves

Air Mortar User Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Series K Air service units G 1/8, G 1/4

CAPITAL CONTROLS SERIES NXT3000

Inverse Proportional Pressure-Relief Cart., Size 2 4

For Models M15, M25, M50 & D50. How to Install, Use, and Care for Your New Monkey MONKEY PUMPS LESS WORK MORE MONKEY TM

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

PVQ 13 A2 R SE 1 S 20 C-11 D

GRUNDFOS DOSING ALL PRODUCT

Nikuni KTM Series Pumps

Pressure Dump Valve Service Kit for Series 3000 Units

Transcription:

SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid) from 32 F to 104 F (0 C to 40 C). Light-weight models either 3.75 lbs. (1.7 kg) or 4.0 lbs. (1. kg). Low-noise, less than 5 db Stroke length fixed at 1.0 mm. 10 www.hydra-cell.eu

SM Models Manual Control Low in Cost and Easy to Operate SM models feature a simple hand-operated speed stroke dial. Each pump runs at a maximum of 300 strokes per minute and a minimum of 15 strokes per minute. Discharge volume can be set up to the maximum flow capacity in 0.1 ml/m units. SM Series Flow Capacities and Pressure Ratings Maximum Discharge Volume Maximum Discharge Pressure Model Number ml/min gph lph psi bar SM030 High Pressure 2 0.44 1. 217 15 SM030 30 0.4 1.0 145 10 SM00 0 0.95 3.0 11 SM100 100 1.59.00 5 4 SM03R* High Pressure 2 0.44 1. 217 15 SM03R* 30 0.4 1.0 102 7 SM0R* 0 0.95 3.0 102 7 SM10R* 100 1.59.00 5 4 *Models equipped with internal relief valve. www.hydra-cell.eu 11

SM Models Special Features Minimal Parts for Easy Maintenance Solenoid Discharge Joint Pump Shaft Pump Head Diaphragm Suction Joint Stroke-speed Adjustment Dial Spare Parts Kits to Extend Pump Service Life Two kits are available to cover spare parts needs for SM models. Individual sets are also available as spare parts: Diaphragm Sets Relief Valve Sets Air Release Knob Sets Air Release Nozzle Sets Head Bolt Sets 12 www.hydra-cell.eu

SM Models Special Features Safety Mechanisms to Prevent Air Lock Outgassing results when the fluid pressure drops below the saturation pressure of a gas dissolved in a liquid. If this occurs, gas comes out of the solution and builds up inside the pump. When air enters the pump head, it prevents the chemicals from being discharged. SM model pumps for outgassing fluids (e.g. Sodium Hypochlorite) feature an innovative design to minimise dead space and prevent air entry and build-up in the pump. If gas air does enter the pump or if outgassing occurs, the CL and CA (Acrylic pump head) versions each feature mechanisms to combat air lock and outgassing. All CL and CA pump head models feature a transparent liquid end that enables the operator to see whether air is present in the pump head. Air Release Knob Air Release Port SM CL models 030, 00, and 100 have a manual air release knob that functions in the same manner as other SM 030, 00, and 100 models. Switch off the pump; attach the supplied tubing to the air release port and tank or container; switch the pump on to the maximum flow rate; and turn the knob counterclockwise 1 to 1-1/2 rotations. After the air is fully purged, turn the knob clockwise until tight, and then switch off the pump. CL Acrylic pump head with manual air release knob and air release port Air Release Knob with Integral Air Relief Valve Air Release Port SM CL models 03R, 0R, and 10R have a manual air release knob that functions in the same manner as other SM 03R, 0R, and 10R models. Switch off the pump; attach the supplied tubing to the air release port and tank or container; switch the pump on to the maximum flow rate; and turn the knob clockwise approximately 90 degrees. After the air is fully purged, turn the knob clockwise again until a click is heard. Then switch off the pump. CL Acrylic pump head with integral air release valve Air Release Port Chemical Discharge Port Air release with the CA version of SM model pumps is simple and automatic. Entrapped gas is discharged from the air release port on top, and the chemical is discharged through a center port. Bubbles or gas in the chemical tank or container are sucked into the pump head. They pass through the air release joint and are fed back to the chemical tank or container along the air release pump. After all of the bubbles or gas are discharged from the pump head, the chemical is discharged from the discharge side. CA Acrylic pump head with automatic degassing www.hydra-cell.eu 13

SM Models Manual Control Specifications Chemical Injection Including High-pressure Boiler Feed 030 & 03R Models 00 & 0R Models 100 & 10R Models PVC Liquid End PVC or PVDF 31SS (High-pressure Boiler) PVC or PVDF 31SS PVC or PVDF 31SS Order Codes PE/PF/KE/KF/KP ST BH PE/PF/KE/KF/KP ST PE/PF/KE/KF/KP ST Maximum Discharge 30 ml/min 27 ml/min 2 ml/min 0 ml/min 55 ml/min 100 ml/min 95 ml/min Volume 0.4 gph 0.43 gph 0.44 gph 0.95 gph 0. gph 1.59 gph 1.51 gph 1. lph 1. lph 1. lph 3. lph 3.3 lph.0 lph 5.7 lph Maximum Discharge Pressure 145 psi (10 bar) 73 psi (5 bar) 217 psi (15 bar) 145 psi (10 bar) 73 psi (5 bar) 145 psi (10 bar) 73 psi (5 bar) Connection (Hose/Tube) Discharge Side 4 x 9 x (PTFE) 4 x x 11 x (PTFE) x 11 x (PTFE) (PVC braided hose) (nylon tube) (PVC braided hose) (PVC braided hose) Suction Side x (PE)* x (PTFE) 4 x 9 x (PE)* x (PTFE) x (PE)* x (PTFE) (PVC braided hose) I.D. x O.D. 1/4 x 3/ (PE)* 1/4 x 3/ (PE) 1/4 x 3/ (PE) 1/4 x 3/ (PE)* 1/4 x 3/ (PE) 1/4 x 3/ (PE)* 1/4 x 3/ (PE) *(FEP) for KP pump heads Outgassing Fluids Including Sodium Hypochlorite Injection 030 Models 03R Models 00 Models 0R Models 100 & 10R Models Liquid End Acrylic Acrylic Acrylic Acrylic Acrylic Order Codes CL/CA CL/CA CL/CA CL/CA CL/CA Maximum Discharge Volume 30 ml/min 30 ml/min 0 ml/min 0 ml/min 100 ml/min 0.4 gph 0.4 gph 0.95 gph 0.95 gph 1.59 gph 1. lph 1. lph 3. lph 3. lph.0 lph Maximum Discharge Pressure 145 psi (10 bar) 102 psi (7 bar) 11 psi ( bar) 102 psi (7 bar) 3 psi (4 bar) Connection (Hose/Tube) Discharge Side 4 x 9 (PVC braided hose) x 11 (PVC braided hose) x 11 (PVC braided hose) Suction Side x (PE) x (PE) x (PE) I.D. x O.D. 1/4 x 3/ (PE) 1/4 x 3/ (PE) 1/4 x 3/ (PE) Note: All R models include a 4 x soft PVC hose for the integral relief valve air release. 14 www.hydra-cell.eu

SM Models Manual Control Specifications General Specifications Stroke Speed Stroke Length Maximum Allowable Viscosity Temperature Ranges Ambient Humidity Environmental Protection Altitude of Installation Location Noise Level 15 to 300 strokes/minute (manual dial setting) Fixed at 1.0 mm 50 mpa (50 cps) Ambient: 32 F to 104 F (0 C to 40 C); Transfering Liquid: 32 F to 104 F (0 C to 40 C); no freezing allowed 35% to 5% RH IEC standard; IP5 or equivalent (waterproof & dust-resistant) Less than 3,20 ft. (1,000 m) Less than 5 db Weight PVC/PDVF/31SS Models 3.75 lbs. (1.7 kg) Acrylic 030 & 03R Models 3.75 lbs. (1.7 kg) Acrylic 00/100 & 0R/10R Models 4.0 lbs. (1. kg) Power Supply Rated Voltage AC 100 to 240 V (±10%) Phase/Frequency 1-phase/50 or 0 Hz Maximum Current 2.0 A Maximum Power Consumption 200 VA Average Power Consumption 15 W (A) B D C E G (F) 14 Dimensions All dimensions in millimetres (mm). PVC, PVDF & 31SS Pump Heads (A) B The shape and dimensions differ slightly depending on the liquid-end material and connection type. 3 72 D C E G (F) Liquid End (A) B C D E (F) G PVC 20 152 7 7 1.5 150.5 PVDF 227.5 195 97.5 97.5 17.5 142 9.5 31SS 193 139 7 3 1.5 150.5 The mounting pitch allows mounting from to mm. Acrylic Pump Heads 72 7 (120) (57) (190) (20) 152 7 7 1.5 3 (202) (150.5) PVC (High-pressure) Pump Heads 14 72 7 (57) (190) 3 (202) 14 7 (57) (190) (202) The mounting pitch allows mounting from to mm. www.hydra-cell.eu 15

SM Models How to Order SM03RPES SM03RKPS SM03RCLS SM030CAS SM030STB SM030KPE How to Order A complete pump order number contains digits based on the specified pump materials listed below. 1 S 2 M 3 4 5 7 Order Digits Code SM Series Solenoid Pump 1-2 SM Manual control with stroke speed dial 3-5 Flow Rate 030 30 ml/min 00 0 ml/min 100 100 ml/min 03R 30 ml/min with relief valve 0R 0 ml/min with relief valve 10R 100 ml/min with relief valve - 7 Materials of Construction: Head/O-ring/Valve Seat/Joint/Valve or Ball Stop (All contain PTFE diaphragms and ceramic check valve balls) Application PE PVC/EPDM/EPDM/PVC/PVC General chemicals PF PVC/FKM/FKM/PVC/PVC General chemicals KE PVDF/EPDM/EPDM/PVDF/PVDF General chemicals KF PVDF/FKM/FKM/PVDF/PVDF General chemicals KP PVDF/FKM/PTFE/PVDF/PTFE General chemicals ST 31SS/PTFE/-/Ceramic/PTFE General chemicals CL Acrylic/FKM/FKM/PVC/PVC Outgassing fluids without automatic air release CA Acrylic/FKM/FKM/PVC/PVC (Hastelloy Spring) 030, 00, and 100 models only Outgassing fluids with automatic air release BH PVC/EPDM/PTFE/PVC/PVC 030 and 03R models only High-pressure boiler Power Plug S North American Plug Standard B UK Plug CE UK E European Plug CE Europe L Asia Lead wire only 1 www.hydra-cell.eu