Calibration Procedure

Similar documents
Calibration Procedure

Calibration Procedure

Calibration Procedure

Calibration Procedure

DeFelsko PosiTector CMM IS Probe

Calibration Procedure. PosiTest DFT Combo

PosiTector UTG, UTG-STD & UTG-ME

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

Standard Recommended Practice. Field Measurement of Surface Profile of Abrasive Blast-Cleaned Steel Surfaces Using a Replica Tape

Testex Tape Data Sheet / Instructions

Lab 1. Adiabatic and reversible compression of a gas

Installation and Operation Manual

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

BI-680 Online Dissolved Oxygen Controller Instruction Manual

March Madness Basketball Tournament

Cover Page for Lab Report Group Portion. Head Losses in Pipes

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Surface Texture Gage study in the qs-stat Measurement System Analysis Module

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

DX2/DXX Operating Instructions

CORESTA RECOMMENDED METHOD N 6

March Madness Basketball Tournament

IN-PLACE DENSITY OF BITUMINOUS MIXES USING THE NUCLEAR MOISTURE-DENSITY GAUGE FOP FOR WAQTC TM 8

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

SS32L Dissolved O 2 Probe

Stadium Project - DP-70 Atlanta, GA, 9/30/2014

One of the most important gauges on the panel is

Calcimeter Instruction Manual

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

Soil Water Characteristic Curve (SWCC) Using the WP4C

Lesson 14: Modeling Relationships with a Line

Gerald D. Anderson. Education Technical Specialist

CHECK LINE BY ELECTROMATIC DTMB & DTMX. Calibration Instructions

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Standard Operating Procedure

SECTION 1. READING AND WRITING NUMBERS PLACE VALUE

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

BAPI Pressure Line of Products - FAQs

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

INTRODUCTION Porosity, permeability, and pore size distribution are three closely related concepts important to filter design and filter performance.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Exercise 3. Power Versus Wind Speed EXERCISE OBJECTIVE DISCUSSION OUTLINE. Air density DISCUSSION

PRESSURE-TEMPERATURE RELATIONSHIP IN GASES

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

The Discussion of this exercise covers the following points:

Chapter 12 Practice Test

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

Cover Page for Lab Report Group Portion. Drag on Spheres

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Residual Stresses in Railway Axles

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

STANDARD SCORES AND THE NORMAL DISTRIBUTION

Technical Procedure for Instrument Calibration and Maintenance

DQM Annual Hopper QA Checks

SHIMADZU LC-10/20 PUMP

RAM 4021-DPX Operation Manual

Grade: 8. Author(s): Hope Phillips

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

A Performanced Based Angle of Attack Display

Thermal Profiling the Reflow Process

Wrinkle Containment and Pressure Uniformity Control for Dry Film Resist Lamination

Vapor Pressure of Liquids

Document Number: 302/34000/76 SV/sv Revision: (B) 2009/02/05

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

Transpiration. DataQuest OBJECTIVES MATERIALS

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

ali-q TM Gravimetric Verification Procedure

Gas Pressure and Distance The Force of the Fizz Within, By Donell Evans and Russell Peace

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Design of a Solid Wall Transonic Wind Tunnel

Chapter 7. SCIIB Pressure Sensor Performance Evaluations: Experiments, Results and Discussions

HEATEC TEC-NOTE Publication No Revised

FIG: 27.1 Tool String

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF SLURRY RHEOLOGY METHOD: T WP

Proficiency Testing for Surface Roughness Standard and Groove Depth Standard

Golf Team Challenge. Product: EA SPORTS PGA TOUR Software Version: Release Date: 10/18/06. Revised 4/21/2009

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Measuring Mass and Volume

Pneumatic high-pressure controller Model CPC7000

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Location of CC Number if not located with the identification:

State of Nevada Department of Transportation Materials Division

Nuclear Associates

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

BAUSCH & LOMB ENGINEERING ROCHESTER. Title: Membrane Press Procedure Page 1 of 14

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

σ = force / surface area force act upon In the image above, the surface area would be (Face height) * (Face width).

MM LITE Puck Wear Surfaces Replacement Rev.: B Page 1 of 5

Subpart E. Pressure Testing

ANALOG PRESSURE GAUGE

Transcription:

Management Procedure 2565 Revision: A Date Issued: October 30, 2017 Date Revised: Calibration Procedure DeFelsko Corporation PosiTector RTR-3D Replica Tape Reader Probe Table of Contents 1 Introduction and UUC Performance Requirements... 2 Table 1-1 Measurement Ranges... 2 2 Measurement Standards and Support Equipment Performance Requirements... 2 Table 2-1 UUC Accuracy Requirements and Description... 2 Table 2-2 Minimum use specification... 3 Table 2-3 Actual Equipment Specification... 3 Table 2-4 Calibration Environmental and Warm-Up Requirements... 3 3 Discussion on the Linearization of Profile Height Readings... 3 4 Preliminary Operations... 4 5 Height Calibration Process... 5 6 Profile Calibration R a & R t... 6 Figure 6-1... 6 Figure 6-2... 6 Figure 6-3... 7 Figure 6-4... 7 7 Performance Requirements... 8 Table 7-1 Performance Requirements and Calibration Data for PosiTector RTR-3D... 8 Management Procedure Change Notice... 9 Management Procedure 2565 Rev. A Page 1 of 9

1 Introduction and UUC Performance Requirements 1.1 This procedure describes the calibration of the DeFelsko Corporation PosiTector RTR- 3D tape reader probe with the following specification: Table 1-1 Measurement Ranges Unit Measurement Range 20-115 microns H & H L * (0.8 4.5 mils) 10-115 microns R t R a 2 microns minimum * Note the PosiTector RTR-3D measures the average maximum peak-to-valley profile height of Press-O-Film TM replica tape. Values are reported as either H or H L. H readings represent the average maximum peak-to-valley profile height. H L readings represent the linearized peak-tovalley profile height measurement that has been adjusted for the non-linearity of replica tape. 1.2 Peak density of the DeFelsko Corporation PosiTector RTRP replica tape reader is not calibrated. 1.3 The unit being calibrated will be referred to as the UUC (Unit-Under-Calibration). 2 Measurement Standards and Support Equipment Performance Requirements 2.1 The UUC accuracy requirements are based upon the published UUC performance specifications. 2.2 The test uncertainty ratio applied in this Calibration Procedure is 4:1 unless otherwise stated. 2.3 The Minimum-Use-Specifications are the minimum test equipment specifications required to meet all the UUC accuracy requirements and the test uncertainty ratio applied. Table 2-1 UUC Accuracy Requirements and Description Parameter Performance Specifications Test Method H 20 115 um ± 5 um (0.8 4.5 mils) (± 0.2 mils) Height Gage H L 20 115 um ± 10 um (0.8 4.5 mils) (± 0.4 mils) Derived, see section 3 R t 10 115 um ± (5 um + 5% of reading) Reference Standards R a 2 um min. ± (0.25 um + 5% of reading) Reference Standards Management Procedure 2565 Rev. A Page 2 of 9

Table 2-2 Minimum use specification Parameter Range Accuracy H 20 115 um (0.8 4.5 mils) ± 1.25 um (± 0.05 mils) R t 10 115 um (0.4 4.5 mils) ± 1.37 um (± 0.05 mils) R a 2 um minimum (0.08 mils min.) ± 0.09 um (± 0.004 mils) Table 2-3 Actual Equipment Specification Parameter Equipment Generic Name Range Accuracy Manufacturer / Model # s Applicable H Height Gage 25 mm (0.984 ) ± 0.10 um * (± 0.04 mils) Heidenhain CT2501 with ND287 display Drag Stylus 350 um ± 0.27 um Mitutoyo SJ-201 H L (13 mils) (± 0.01 mils) Spring Micrometer 1 mm ± 5 um Testex metric analog (0.393 ) (± 0.0002 ) micrometer R t Roughness Specimen 9.9 20.08 um (0.4 0.8 mils) ± 0.32 um (± 0.01 mils) Rubert + Co. type 525X & 526X R a Roughness Specimen 3.139 6.36 um (0.1 0.3 mils) ± 0.067 um (± 0.002 mils) Rubert + Co. type 525X & 526X * (± 0.034 um with linear error compensation by the ND287) Caution: The instructions in this Calibration Procedure relate specifically to the equipment and conditions listed in Section 2. If other equipment is substituted, the information and instructions must be interpreted accordingly. Table 2-4 Calibration Environmental and Warm-Up Requirements Measurement Standards & Support Equipment Temperature: 23 ± 5 C. Environmental Requirements: Relative Humidity: Less than 95% Measurement Standards & Support Equipment Warm-up and Stabilization Requirements: Not Required 3 Discussion on the Linearization of Profile Height Readings H L readings are determined in the following manner. Replica tape determinations of profiles using a spring micrometer are plotted against profiles obtained with electronic stylus roughness instruments and a separate response curve is then determined for each grade, or thickness, of replica tape. The curves are represented by the mathematical functions, F c for Coarse grade and F xc for X-Coarse grade. These functions relate replica thickness (H) to electronic stylus roughness R t (not the Rt reported by the RTR) as: R t = F C (H) and R t = F XC (H). The computed R t is mapped to a least squares straight line fit of the combined F c and F xc curves, the result of which is what the gage reports as H L. Management Procedure 2565 Rev. A Page 3 of 9

The deviations associated with this linearization are illustrated below. Note that the areas of greatest deviation occur where the tape is least linear, at the upper and lower ends of the range. The accuracy of the H L reading versus R t is determined by performing a sum of squares on the deviations of the system. There are three sources of significant deviations in the system. The first source is the equipment used in collecting the data used for generating the functions F c and F xc. The second source is the deviations of the least squares straight line fit. The final source is the accuracy of the gage H reading. The accuracies of the equipment used in collecting the data are ± 5 microns for the spring micrometer and± 0.27 microns for the drag stylus. The maximum deviation between H L and R t is ± 8 microns as shown in the H L deviation chart. The H reading as determined by the RTR has an accuracy of ± 5 microns that when applied to the equation of the line shown in the H L Deviation chart results in deviations of ± 0.85 microns. Performing a sum of squares on the system deviations yields: = ((5) 2 + (0.27) 2 + (8) 2 + (0.85) 2 ) 0.5 = (25 + 0.07 + 64 + 0.72) 0.5 = 9.47 microns 4 Preliminary Operations Note: Review the entire document before starting the calibration process. 4.1 Visual Inspection 4.1.1 Visually inspect the UUC for: Contamination on the measuring surfaces Damage to the buttons or probe housing Misalignment of the measuring surfaces Proper identification For body/probe combinations review the body for damage 4.1.2 Damage or excess wear shall be repaired prior to beginning the calibration process. 4.2 Probe Cleaning 4.2.1 Ensure the UUC is powered off. Management Procedure 2565 Rev. A Page 4 of 9

4.2.2 Place a card reader cleaning card between the measuring surfaces. 4.2.3 Squeeze both buttons of the probe simultaneously to close the measuring head. 4.2.4 While keeping the buttons depressed, move the provided cleaning card back and forth several times. Note: The cleaning card can be used multiple times. Do not use isopropyl alcohol to clean the RTR-3D. 4.2.5 Repeat steps 4.2.2 to 4.2.4 using the provided microfiber cloth. 4.2.6 Inspect the measuring surfaces. If there is any contamination, repeat the cleaning process. 4.3 Gage Reset: 4.3.1 When the UUC is powered down, simultaneously hold the + and middle buttons until the reset symbol appears. 4.3.2 When the UUC prompts you, depress both probe buttons simultaneously to perform a probe zero. Make sure to hold the buttons until you hear the UUC beep. 5 Height Calibration Process Note: Whenever the test requirement is not met, verify the results of each test and take corrective action before proceeding. 5.1 Review the Performance Requirements Table 7-1. 5.2 Select Cal Settings, then Tape Grade to select the proper tape grade. For the 75 micron (3 mil) shim select C, for the 125 micron (5 mil) shim select XC. 5.3 Depress both probe buttons simultaneously without a shim in the probe to zero the probe. This must be done before every measurement. 5.4 Insert the 75 micron (3 mil) shim between the measurement surfaces and depress both probe buttons simultaneously. Any movement of the shim during the measurement process will impact the measurement, so let go of the shim once the probe is holding the shim. 5.5 After the measurement is complete, hold the shim, release the probe buttons and remove the shim. Record the measurement value (H L or H). Note: The PosiTector RTR measures the average maximum peak-to-valley profile height of Press-O-Film TM replica tape. The gage subtracts 50.8 microns (2 mils) from measurements to Management Procedure 2565 Rev. A Page 5 of 9

compensate for the thickness of the polyester film on the Press-O-Film TM. When measuring shims all readings will be 50.8 microns (2 mils) lower than actual. 5.6 Select the Cal Settings menu and change the Linearize setting. 5.7 Record the new displayed value (H or H L ) 5.8 Repeat steps 5.2 5.7 with the 125 micron (5 mil) shim. 6 Profile Calibration R a & R t 6.1 Use the 1.5 (38mm) diameter ball to burnish two XC optical grade replica tape samples, one each on the two surface roughness standards 525X and 526X. Align the tape as shown below. Figure 6-1 6.2 From the main menu select ANALYSIS SETUP then 2D Parameters. Select R t and confirm that R a is also selected. Figure 6-2 6.3 Press the minus button to return to the ANALYSIS SETUP menu and select Short Filter. Select the 0.008 mm setting then Exit. 6.4 Clean and zero the probe and verify the tape is clean of debris and adhesive residue. Management Procedure 2565 Rev. A Page 6 of 9

6.5 Measure the 525X sample, S/N PA6, and record the R a & R t readings in table 7-1. Figure 6-3 6.6 From the main menu select ANALYSIS SETUP then Cutoff Filter. Select the 0.25 mm setting then Exit. Figure 6-4 6.7 Clean and zero the probe and verify the tape is clean of debris and adhesive residue. 6.8 Measure the 526X sample, S/N P51X, and record the R a & R t readings in table 7-1. Management Procedure 2565 Rev. A Page 7 of 9

7 Performance Requirements Table 7-1 Performance Requirements and Calibration Data for PosiTector RTR-3D Standard Reading Adjusted Shim Reading Min. Reading Allowed UUC Reading Max. Reading Allowed A B H = H L = H = H L = N/A R a = N/A R t = N/A R a = N/A R t = Calculation H & H L : (A 50.8) Calculation H: (B 5). Round up to the nearest micron. H L : (B 10) Round up to the nearest micron. R a : (A*0.95) - 0.25 Round up to the nearest 0.1 micron R t : (A* 0.95) - 5 um Round up to the nearest 0.1 micron Calculation H: (B + 5). Round down to the nearest micron. H L : (B + 10) Round down to the nearest micron. R a : (A*1.05) + 0.25 Round down to the nearest 0.1 micron R t : (A* 1.05) + 5 um Round down to the nearest 0.1 micron To convert from microns to mils divide by 25.4 Management Procedure 2565 Rev. A Page 8 of 9

Management Procedure Change Notice Procedure Number: MP 2565 Revision Level: A Date of Change: October 30, 2017 Title: Calibration Procedure for PosiTector RTR-3D Reason for Change: New product Description of Change: New procedure I confirm I have read and understand the procedure and the change described above. Printed Name Signature Date Management Form 0010.02-05/1998 Management Procedure 2565 Rev. A Page 9 of 9