KVALIFIK Ltd. has founded in 1991. In 1993 our calibration laboratory has get the accredited status and we have calibrated standards for the generally used physical parameters. Our standards are traceable to national and international standards. Our company can calibrate instruments in the laboratory or on the spot. Furthermore we can measure temperature and relative humidity uniformity of equipments and air-conditioned areas. We can validate and qualificate food industrial and pharmaceutical equipments, test cleanrooms, measure and repair air filters. We can also translate and vet technical texts and instruction manuals. Accreditation of our calibration laboratory is continuous since 1993. Our laboratory has accredited by Hungarian National Accreditation Authority (NAH) according to standard MSZ EN ISO/IEC 17025:2005. Our accreditation number: NAH-2-0133/2015. Valid to: 20.10.2019 Our testing laboratory has get the accredited status in 2003. We perform temperature and relative humidity uniformity measurements. Our accreditation number: NAH-1-1178/2018. Valid to: 07.06.2023 Our accredited calibration laboratory specialized for calibrating flowmeters is TECHNICOOP Ltd. (property of KVALIFIK Ltd.) Our accreditation number: NAH-2-0186/2018. Valid to: 23.08.2023 Issued calibration certificates fulfil requirements of standard ISO 9000, HACCP, IATF 16949, GMP, GLP, ISO 14001, ISO 17025 Term of calibration: 5 workdays with low prices! Accredited calibration laboratory (Our accreditation number: NAH-2-0133/2015) - Thermometer calibration On-site and laboratory calibration of thermometers, air termometers, temperature transmitters and infrared thermometers. Thermometers: (-90...+1200) C Infrared thermometers: (-30...+1200) C 1/7
- Calibration of temperature display Temperature display calibration of furnaces, dry-heat chambers, drying chambers, incubators, refrigerators, freezers etc. (-90...+1200) C - Pressure gauge calibration in range On-site and laboratory calibration of absolute and overpressure gauges, vacuum meters, transmitters and pressure calibrators. abs. 3 µbar...1000 bar overpessure (-1...0) bar vacuum - Relative humidity meter, dew point meter and transmitter calibration on-site and in the laboratory. relative humidity: (2...99) rh% dew point: (-40...+25) C - Length meter and sieve calibration on-site and in the laboratory Calibration ranges: Vernier calipers: (0...1000) mm Depth and height meters, micrometers: (0...600) mm Measuring tapes, rulers (only in the laboratory): (0...50) m Indicators, inner dimension meters, built-in micrometers: (0...50) mm Sieves: 20 µm...200 mm Thickness meters: (0...100) mm Coating thickness meters: (0...3) mm Feeler gauges, thickness standards: (0.005...25) mm High precision thickness standards (only in the labor) (0.005...5) mm Individual length values: (0...5500) mm - Watch, stopwatch and timer calibration on-site and in the laboratory 2/7
- Electric meter calibration on-site and in the laboratory Multimeters, 0.01 ma...20 A DC-AC 50 Hz digital oscilloscopes: 0.01 mv...1 kv DC-AC 50 Hz 2 mω...500 GΩ, 10 Hz...1 GHz Insulation meters: 2 mω...500 GΩ Flashback testers: 1 mv...10 kv Current clamps: 1 A...1 ka, DC (1...850) A, AC 50 Hz Resistance standards: 100 µω...1 TΩ Conductivity meters: 100 ns/cm...500 S/cm Voltage sources: 1 mv...10 kv DC-AC 50 Hz Current sources: 20 µa...3000 A DC 20 µa...2000 A AC 50 Hz Capacitance meters and decades: 1 nf...999 µf Inductivity meters and decades: 10 µh...10 H - Optical tachometer calibration on-site and in the laboratory (1 1 000 000) min -1 - Revolution-controller calibration on-site and in the laboratory (0 99 999) min -1 - Anemometer, anemometer transmitter calibration on-site and in the laboratory (0.15...40) m/s - Torque wrench, screwdriver and limitor, torque meter calibration onsite and in the laboratory. Torque wrenches, screwdrivers and limitors: Torque meters: (0.1...1100) Nm (0...100) Nm - Balance calibration on-site and in the laboratory. 1 mg 710 kg 3/7
- Force meter calibration on-site and in the laboratory. 2 N 60 kn - Pipette, burette, dispenser calibration in the laboratory. Maintenance, adjusting and repairing of pipettes and burettes. 10 µl 160 ml - Illuminance meter calibration on-site and in the laboratory. (10 4000) lx - Refractometer calibration on-site and in the laboratory. (1.3330 1.51710) RI (0 91) Bx - ph-meter calibration on-site and in the laboratory. Calibration values: 1.675 ph 7.429 ph 4.002 ph 9.225 ph 5.00 ph 10.062 ph 6.881 ph 12.00 ph Accredited calibration laboratory (Our accreditation number: NAH-2-0186/2018) - Rotameter, nozzle and flowmeter (with gaseous agent) calibration on-site and in the laboratory. (0 2000) L/min 4/7
CALIBRATIONS TRACEABLE TO THE (INTER)NATIONAL STANDARDS Volume meters (e.g. retorts, measuring vessels) Hardness meters (Shore A and D) Weights with adjusting Bore meter, measuring gauges Viscosimeters Mechanical tachometers Air volume meters Low volume liquid flowmeters Sieve tension meters Gasproofing testers Wood moisture content meters Road testing equipments Accredited testing laboratory (Our accreditation number: NAH-1-1178/2018) Temperature uniformity tests of heating chambers, climate chambers, thermostats, sterilizing chambers, ultra-freezers, freezers, refrigerators, cooling rooms, cooling trucks, air-conditioned rooms, storages, autoclaves, furnaces, heating furnaces, tunnel furnaces, water baths, tunnels, vessels, incubators using computerized datalogger system up to 290 sensors simultaneously. Relative humidity uniformity tests of climate chambers and airconditioned volumes using computerized datalogger system up to 100 sensors simultaneously. Producing reports with tables, colour charts, statistics and qualification of the equipment. TECHNICAL TRANSLATION Translation of ENGLISH and GERMAN instruction manuals, technical documents based on many years experience in pharmaceutical, packaging and food industry. 5/7
INDUSTRIAL SERVICES Testing and qualification of equipments Testing of pharmaceutical and laboratory equipments and road testing machines producing full documentation (IQ, OQ, PQ and SQ - control software validation) according to the customer's demand. E.g. qualification of pharmaceutical machines. Air status measurements (e. g. cleanrooms, hospital operational rooms) Testing and qualification (DQ, IQ, OQ, PQ) of HVACs, cleanrooms, hospital operational rooms, chemical chambers, weighing chambers as well as verifying of air filters. INSTRUMENT SELLING Industrial measuring systems Installing and calibrating on-site multi-channel temperature, relative humidity, pressure, differential pressure, air velocity etc. datalogger and registrator systems according to your demand either in wireless version or with SMS alarming. Installing systems for measuring corrected effective temperature. Temperature, relative humidity, pressure and differential pressure meters, stopwaches, multimeters, Vernier calipers, micrometers, dial indicators, measuring tapes, ph meters, conductivity meters, tachometers, air velocity meters with or without calibration. 6/7
OUR STABLE PARTNERS GUIDANCE...and more than 2000 companies. Our qualified specialists with many years experience are ready to helping you in case of all measuring, instrument selling and calibration question. KVALIFIK Ltd. Telefon: +36 (1) 246-36-78, +36 (1) 246-36-79, +36 (1) 246-70-12 Fax: +36 (1) 246-36-00 E-mail: info@kvalifik.hu www.kvalifik.hu 7/7