Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Similar documents
Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Two-stage valve type NE

Pressure-controlled shut-off valve type CNE

Pressure-reducing valve type CDK

Diaphragm accumulator type AC

Pressure reducing valves type CDK

Pressure reducing valve, pilot operated

Diaphragm accumulator type AC

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, direct operated

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Check valve hydraulically pilot operated

Over-center valves type LHT with oscillation damping, zero leakage

3-Way Pressure-Reducing Cartridge, Size 2 4

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

2-way flow control valve Model 2FRM 6

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pressure relief valve, direct operated

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure-Relief Cartridge Valve, Size 4

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Leak-Free Load-Control Valve SAE ½ psi flange

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

DK ton, Double-acting, Die-type Crimping Tool

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Related Products: Auto Drain Valve. Model/Specifications. Model

Technical Data Sheet TI-F50 Locking Units series KFH

Monoblock Directional Control Valve RMB 202

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Cooler-Bypass Thermostat Valve, Size 16

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

180 Series Rotary Shear Directional Control Valve

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Fixed Displacement Motor A4FM

Leak free Pipe Rupture Valve for Excavators

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Controllers DR, DP, FR and DFR

MANUAL. Sesame. Thermoplastic Tank Technologies

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Hydraulic Punch Drivers

Fixed Displacement Plug-In Motor A2FE

Electrically Operated Pressure-Relief Cartridge, Size 10

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Manual Actuated Boiler Blowdown Valves

Pressure relief valve, direct operated Type DBD

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

750 Cable Cutter INSTRUCTION MANUAL

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

Series IRV1000/2000/3000

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DNS. Monoblock directional control valves DNS - Directional control valve

Unit 24: Applications of Pneumatics and Hydraulics

ALF400 to 900, ALT-5/-9

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Electro-Pneumatic Converter YT-940 SERIES

Pressure maintenance valve SDV-P / SDV-P-E

Operation Manual Air Saver Unit ASV5000 Series

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

FPD20 Series. Gear wheel flow sensor

Inverse Proportional Pressure-Relief Cart., Size 2 4

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

3-Way Safety Block DSV

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

EXH. Specifications. Descriptions. Min. working pressure MPa

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

CAST IRON SAFETY VALVE TYPE 6301

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

VACUUM REGULATORS CONTENTS

Air operated valve. VGA342R Series

Pressure Sensing Valve - Model 4023

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Hydraulic Punch Drivers

Siphon vessel / Priming aid

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

HPB25 Hydraulic Paving Breaker

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

ASB Accumulator Safety Blocks

Transcription:

Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1

by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated on: 28.06.2018 2/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

Contents 1 Overview of hand pump type CH... 4 2 Available versions, main data... 5 3 Parameters... 7 4 Dimensions... 9 4.1 Hand pump CH 08 P, CH 08 P-S... 9 4.2 Hand pump CH 08 G-AS... 10 5 Assembly, operation and maintenance recommendations...11 5.1 Intended use... 11 5.2 Assembly information... 11 5.3 Operating instructions...12 5.4 Maintenance information...12 HAWE Hydraulik SE D 7147 CH - 04-2018-1.1 3/13

1 Overview of hand pump type CH Hand pumps are a type of hydraulic pump. They generate a ow rate manually. The hand pump type CH is single acting. It draws oil in when the hand lever is moved in one direction and discharges it when the hand lever is moved in the opposite direction. The hand pump type CH is available for pipe connection and manifold mounting. Features and bene ts: Sturdy design Corrosion-resistant Zero-leakage pressure connection Intended applications: Marine Mining equipment Wind turbines Fixture construction Hand pump type CH 4/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

2 Available versions, main data Circuit symbol: CH 08 P CH 08 P-S CH 08 G-AS Order coding example: CH 08 G -AS -200 Pressure setting Additional function Table 3 Pressure setting Table 3 Additional function Model Table 2 Model Basic type and size Table 1 Basic type and size Table 1 Basic type and size Basic type and size Design Function Displacement volume V Stroke max (cm 3 /stroke) CH 08 Open Single-acting 8.3 300 Pressure p max (bar) Note Stroke: Hand lever from one end position into the other and back again Suction port able to bear up to 150 bar Pressure on port S has effect through the pumps above port P until the connected consumer or the directional valve connected between them. The hand lever is pressed in the end position. HAWE Hydraulik SE D 7147 CH - 04-2018-1.1 5/13

Table 2 Model Coding G P Description Pipe connection Manifold mounting Table 3 Additional functions Coding No designation S AS Description None Pressure-limiting valve (adjustable with tool) Pressure-limiting valve (adjustable with tool) and drain valve Pressure range (bar): 50 to 300 Note Position of pressure-limiting valve Type CH 08 P-S: The pressure-limiting valve is located after the check valve on the pump side. The pressure-limiting valve protects against pressure that is too high, which could be caused by the pump. It does not offer protection against an increase in pressure in the P line, caused by e.g. a temperature increase. Type CH 08 G-AS: The pressure-limiting valve is located before the check valve on the pump side. It provides protection both for pressure increases through the pump as well as coming from the P line. 6/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

3 Parameters General information Designation Design Model Material Installation position Actuation torque [Nm] Ports Hand pump Open, single-acting Pipe connection or manifold mounting Steel; nitrided valve housing, electrogalvanised sealing nuts and connection block, hardened and ground functional inner parts Pump housing: Nickel-zinc coating hardened As desired Setting up: Keep suction line short. Set up oil tank at the same level or higher than the suction ports. This prevents drainage of the suction line at rest. 310 Nm (at 250 bar) P = pressure connection S = suction port Hydraulic uid Hydraulic oil: according to part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. Pressure and ow rate Operating pressure Displacement volume Static overload capacity p max = 300 bar Suction port p s < 150 bar V g = 8.3 ccm Pressure connection P: approx. 2 x p max (600 bar) HAWE Hydraulik SE D 7147 CH - 04-2018-1.1 7/13

Weight Type CH 08 P CH 08 P-S CH 08 G-AS = 2.3 kg = 2.3 kg = 3.0 kg 8/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

4 Dimensions All dimensions in mm, subject to change. 4.1 Hand pump CH 08 P, CH 08 P-S 1 Pressure-limiting valve, only for type CH 08 P-S Base plate hole pattern Sealing of the ports: O-ring P, S 14x1.6 HAWE Hydraulik SE D 7147 CH - 04-2018-1.1 9/13

4.2 Hand pump CH 08 G-AS 1 Centring pin 2 Knob for drain valve 3 Pressure setting Port (ISO 228-1) (BSPP) S G 3/8 P G 1/4 10/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

5 Assembly, operation and maintenance recommendations 5.1 Intended use This product is intended exclusively for hydraulic applications ( uid technology). The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the components, assemblies and the speci c complete system must also always be observed. If the product can no longer be operated safely: 1. Remove the product from operation and mark it accordingly. It is then not permitted to continue using or operating the product. 5.2 Assembly information The hydraulic power packthe product must only be installed in the complete system with standard and compliant connection components ( ttings, hoses, pipes, xtures, etc.). The hydraulic power pack must be shut down correctly prior to dismounting; this applies in particular to power packs with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. HAWE Hydraulik SE D 7147 CH - 04-2018-1.1 11/13

5.3 Operating instructions Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of the hydraulic component. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters".) (also see cleanliness level in 5.4 Maintenance information This product is largely maintenance-free. For hand pump type CH, the drive (lever mechanism) is outside the housing (suction chamber). As such, occasional cleaning and lubrication is necessary. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 12/13 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE

Further information Additional versions Manual pump type H, HD and HE: D 7147/1 D 7147 CH - 04-2018-1.1 HAWE Hydraulik SE Einsteinring 17 85609 Aschheim/Munich Postfach 11 55 85605 Aschheim Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com