EZI-DRY Pty Limited ABN:

Similar documents
PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

Thermocirc Installation and Maintenance Instructions

LPG SAFETY INFORMATION. Kwik-Gas. Safety Manual. Less talk more energy

BREATHERS VC Series. The best-selling traditional breather type, with mechanical valve.

BREATHERS VE Series. The best-selling traditional breather type, with hydraulic valve.

System Pressure Manager Standard & System Pressure Manager Plus

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Breather Control V1.4. Installation Manual

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Niltox Breathing Air Purifier Range

Unit 24: Applications of Pneumatics and Hydraulics

Installation and commissioning instructions 255 series and 256 series

Yoke Block Instruction Manual

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

ANALYTICAL SERVICES MAHANGA HOLDINGS LTD

Endura AZ40 Sensor assembly High temperature filter assembly kit

80 Litre Suction Oil Drainer

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

EHS Laboratory Guidance: Cryogenic Material

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

SIMPLAIR PIPING TOOL. JXT Company

Class 2 Gases Learning Tool

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Pressure Automated Calibration Equipment

GRAPHIC DIVISION. 3D drawings available at

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

MF2M Monnier Miniature Compressed Air Filter

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Design of a Solid Wall Transonic Wind Tunnel

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

Yoke Block Instruction Manual

Technical Bulletin 160. Maximum Air Pressure for Diffusers. by:

Discharge Relief Valve Operation & Maint.

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Series IRV1000/2000/3000

The Glockemann Pump Site & Installation Guide

AVM7 Stainless Steel Thermostatic Air Vent

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

TEST SPECIFICATION NYT-909-C

PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

The number of test stands can be adapted to the special requirements.

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Waterous Relief Valve

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

BITUMEN HEALTH SAFETY & ENVIRONMENT. RBA Training Modules. Bitumen HSE

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

For many applications, there is no technical reason anymore to keep the oil volumes of a transformer with vacuum type OLTC separated

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

TSS21 Sealed Thermostatic Steam Tracer Trap

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

VESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure :

OWNER S MANUAL SUCTION GUN SG-300

Prestige Water Equipment Ltd.

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

Prof AH Basson, Pr Eng March Departement Meganiese en Megatroniese Ingenieurswese. Department of Mechanical and Mechatronic Engineering

Aging Cell, OFITE Style. Included Items

Technology for Life. saver. The. A breath of fresh air when you need it most.

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

NEW TYPE M PRESSURE RELIEF DEVICE

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Cold-acclimatised pipelines

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Peak Pressure Indicator MSI-3

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

PC3_ and PC4_ Pipeline Connectors

Electronic Single and Twin Pump System Pressure Managers

Red Valve Coarse and Fine Bubble Air Diffuser Systems

Schlenk Line. Standard Operating Procedure. Lab: Engineering Sciences Building 155. Department: Materials Science and Engineering. PI: Paul V.

9.0 Equipment Cleaning and Repair

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Pressure Systems Safety Regulation

Transcription:

EZI-DRY Pty Limited ABN: 98 114 507 443 PO Box 370 Phone: 02 49711993 Swansea NSW 2281 Fax: 02 49716320 Mobile: 0427587900 Email: ezidry@exemail.com.au 1. Breather operation Why EZI-DRY Breathers? Most oil filled transformers have a Conservator (similar to the overflow tank on the radiator in a car) or an air space to allow for the expansion and contraction of the oil when it heats up or cools down. The transformer usually incorporates a vent pipe system to the outside atmosphere where the air pressure changes can be vented (breathing). When the oil in the transformer begins to cool down (ambient temp drop or load change) it is critical that the air being drawn into the transformer is as free of moisture as possible. Transformer oil is hydroscopic and will absorb moisture that can damage the insulation qualities of the transformer. Indicating silica gel breathers mounted on the vent pipe are used to absorb moisture in the air that is entering the transformer. The indicating gel typically changes from a blue colour to a pink colour when saturated and this is when it requires replacement. 2. Traditional Breathers Traditionally, breathers have been designed with a single compartment for the silica gel and an oil bath system that prevents the atmosphere from contact with the silica gel unless the transformer is breathing. Once breathing (expansion, contraction of oil) the oil bath will allow the atmosphere to bubble through it with minimal pressure change, sometimes the simple effect of a cloud passing over may produce enough of a temperature change to cause the transformer to breath, though it may only be momentarily. Sometimes when a transformer has a surge of some type within the transformer (fault, fault load) which causes the transformer oil to instantly expand, the oil can be blown out of the oil bath and allow the silica gel to be exposed to direct atmosphere and thus can become saturated regardless whether or not the transformer is breathing. In this type of single compartment unit the moisture will slowly pass throughout the compartment through simple contact action without any airflow and thus prematurely change the colour of the silica gel. This type of breather can also be susceptible to tunnel saturation i.e. the gel can be saturated up through the middle section but cannot be detected from the outside. Typically the traditional type of oil bath breather requires maintenance with the aid of tools, PPE, work area, oil and silica gel, including packaging for disposal of gel and approx 15-20 minutes to complete the work.

3. Ezi-Dry Breathers The EZI-DRY breather system utilises 3 innovative designs that overcome many of the problems associated with the traditional type of breather. 1. A quick connect adaptor is initially mounted on the vent pipe which allows for the quick removal and placement of the breather without the use of tools. This adaptor has a rubber sealing washer which will ensure correct sealing when the breather is screwed home. The same adaptor is used for all the EZI-DRY breathers which allows for easy interchange. 2. A reed valve system (replaces oil bath) is designed to operate at a pressure of 1-2 kpa before it breathes. This will reduce breathing at minor pressure changes, as in the case of a cloud passing over and thus prolonging the life of the silica gel. Any sudden pressure changes will not adversely affect the reeds and they will continue to operate as designed. 3. Specially designed separation discs (minimum of 2) are placed within the EZI-DRY breather to form separate compartments (Min 3 compartments). The silica gel will not prematurely absorb moisture through contact action past each disc. The discs are designed with different placement of vent holes to direct the airflow over a greater area of the silica gel, thus providing greater efficiency and prevents tunnel saturation. If the reed valve should brake (unlikely) the first compartment may become saturated but it will not pass into the next compartment unless the transformer is breathing, ensuring correct operation.

The EZI-DRY breather only requires 10-15 seconds to remove and replace without the use of tools. The disposable cartridge type is self contained and can be disposed in landfill 1 without further preparation and does not require the need for PPE as handling of the silica gel is not required. The disposable units can be mounted as single units, 2 units or 4 units with the addition of a manifold for up to 12,000 litre oil capacity. The larger units for 10,000 litre to 20,000 litre are easy to mount on the quick connect adaptor and are simple to dismantle for recharging if required. EZI-DRY Pty offers a recharge service if required. This information is provided to give a brief outline of breather operation. Maintenance intervals can vary depending on site conditions. If you would like further information please do not hesitate in contacting your supplier or EZI-DRY Pty Ltd direct. 1 See EPA NSW and QLD letter