1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

Similar documents
1800C and 1800C-HC Service Regulators

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800C & 1800C-HC Service Regulators

1800CPB2 Service Regulators

1800CPB2 Pilot-Loaded Service Regulators

SR100 Series Service Regulators. Technical Bulletin

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

Model 1800 PFM Series Regulator. Technical Bulletin

Hawk Mechanical Alley 111 Submittal Log - Hawk Job #: /21/2014. Submittal Status

1800C and 1800C-HC Series Service Regulators

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Noth American 7347 High Pressure Gas Regulators

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

1200B2 Series Service Regulators. Instruction Manual

Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh

1800B2 and 1800B2-HC Series Service Regulators. Technical Bulletin

Industrial Regulator Series 1800/2000

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

S300 Series. Valve Link. Features. Fisher Controls

Type R622 Pressure Reducing Regulator

T208VR Series Tank Blanketing Vacuum Regulator

B34 Series Regulator Commercial and Industrial Regulator

Type 299 Pressure Reducing Regulators

PRO-50 Instrument Supply Regulator

Series 100 Slam Shut Valve. Technical Bulletin

North American 7337A/B/C-4 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators

CL31 Series Commercial Regulator. Advanced Metering and Regulation Technology at Work.

Model 141-A Field Regulator. R-1311 Rev. 9

299H Series Pressure Reducing Regulators

B42 Series Regulator Residential Regulator

B42 Series Regulator

B34S Series Regulator Medium Duty Commercial and Industrial Regulator

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Regulator from 1800 B series

Model 141-A Regulators

CL38 Regulator Commercial & Industrial Regulator

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

CL231 Series Regulator Commercial Regulator

B34S Series Regulator

CL838 Series Twin Parallel Flow Service Regulators

B36 R, N, & M High Pressure Service Regulator

Types S100K and S102K Pressure Regulators

CL231 Series Regulator Commercial Regulator

CL38 Regulator Commercial & Industrial Regulator

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

1805 Series Relief Valves

Precision and Instrument Regulators 1/4" port size

B34S Series Regulator

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

B56 R, N, & M Field Service Regulator

MODEL 240 GAS PRESSURE REGULATOR

B35 Series Regulator R, N, and M Field Service Regulator

North American Orifice Metering System

B31 Series Regulator Light Commercial and Industrial Regulator

J48 Gas Pressure Regulator. Technical Bulletin

B36 R, N, & M High Pressure Service Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

627 Series Pressure Reducing Regulators

< B31R The B31R is the internal relief valve (R) version of the B31 Series. The 1" internal relief valve provides exceptional relief capacity.

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

CL34 Regulator Commercial and Industrial Regulator

B31 Series Regulator Light Commercial and Industrial Regulator

1805 Series Relief Valves

MODEL 274 GAS PRESSURE REGULATOR

2.0 INSTALLATION & SERVICE

Full Range Pressure Compensating Variable Flow Control

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

R-1450 R6. Safety Relief Valve

CL34 Regulator Commercial and Industrial Regulator

Type 99 Pressure Reducing Regulators

MEGR-1627 Instruction Manual

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

CL31 Series Regulator Commercial Regulator

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

66 Series Direct-Operated Regulators and Vacuum Service Equipment

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

SPRING-LOADED GAS PRESSURE REGULATOR

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

CL31 Series Regulator Commercial Regulator

B31 Series Regulator Light Commercial and Industrial Regulator

B31 Series Regulator Light Commercial and Industrial Regulator

RR 16 Commercial & Industrial Regulator

Description Advanced Features Typical Applications

TECHNICAL DATA. Page 1 of 12

Gas Pressure Regulator HON 270 MK2

Homestead Series 820 AWWA Butterfly Valves

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

1305 Series Pressure Reducing Regulators

B531 Series Regulator Twin Parallel Commercial Regulators

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

Transcription:

SB-8506. B Service Regulators Maximum Inlet Pressure 5 PSIG Measurement Engineers Since 86 www.americanmeter.com

B Service Regulators General Information The American Meter Series B pressure regulator is designed for natural gas applications and features a compact, lightweight design for fast, easy installation. Interchangeable orifices and springs provide a wide range of outlet pressures and flow rates. Outlet pressures between.5" W.C. and 5 PSIG are available. Operating temperature range is -0 F to 50 F (-0 C to 65 C). Maximum flow rate is 500 SCFH (70.8 m /h). The diaphragm case may be easily removed for routine inspection without disturbing the line connections. All models conform to ANSI Code B09.-998, and CGA Service-type Regulator Specification CAN/CGA-6.8-M95. Exclusive, 7 - Step Corrosion Protection The protective finish on the B regulator resists corrosive effects of weather and harsh environments better than any other in the industry. Each precision die cast aluminum regulator is treated-inside and out-with a special conversion coating that's part of an exclusive, 7-step finishing process. This coating greatly inhibits oxidation of the metal's surface that can eventually compromise the integrity of the metal. It also prevents finish paint from cracking and blistering. A single coat polyester primer and the high solid polyurethane top coat provides a long-lasting protection to all exterior regulator surfaces. The American Meter conversion coating process meets all environmental protection regulations. High Tensile Strength Valve Bodies Each B regulator is equipped with a high tensile strength cast iron valve body that rotates in 90-degree increments and features extra heavy wall thickness. This provides maximum strength to withstand installation stresses without damage and prevents thread galling experienced with aluminum. Features In response to a market survey, the following features were designed into the B regulator to accommodate the customers needs. " Improved relief performance. " Improved performance repeatability. " Lever design provides for secondary emergency relief in the event of unauthorized removal of the seal plug. " Snap-in internal components (quick change outs). " Non-adjustable relief. " Larger seat disc area. " B and B use the same seal plug to avoid loss of emergency relief should the seal plugs be interchanged. Application The B features a full capacity internal relief valve with large passages to assure the fast release of gas (See performance graphs on page 5). For added protection, a secondary relief valve stop is provided to assure operation under the most severe conditions and in the event the seal plug has been removed. The standard relief spring setting is 8.0" W.C. above the normal 7" W.C. outlet pressure. Valve body configuration permits the B regulator to be supplied in four positions as specified on page 7. All B regulators are available with either right angle (90-degree) or straight flow (80-degree) valve bodies. Vents can also be supplied in four different positions. The B regulator is designed with an extra large, removable weather and bug-proof stainless steel screened vent to resist freeze-ups and to exclude foreign matter. The vent is threaded / inch NPT making it suitable for indoor installations. B regulator valve bodies are treated with a 5-step metal finishing process. The treated metal is painted with a single coat polyester paint. Available valve body sizes are: /" x /", /" x " and " x " NPT or BSP-TR for 80 valve bodys. Also available is a 90 valve body in /" x /", /" x ", " x " and /" x " NPT and /" x /" BSP-TR. ➁ ➀ ➀ AC50 Aluminumcase Meter; ➁ B Regulator;

B Service Regulators Options Meter Bar- The B regulator can be used with a detachable meter bar /" x /" (Part number 776G00), /" x " (Part number 776G00) and " x " (Part number 776G00) for compact and convenient installation to meters with 6 connection centers. Use of a meter bar prevents piping stress from being transferred to the gas meter. Vent Elbow- The regulator vent opening should face downward (6 o'clock) to minimize the chance of blockage from ice and snow. If not, a / NPT plastic, 90 vent elbow (Part number 780P05) and separate protective screen (Part number 7000P07) may be screwed into the vent to provide the necessary protection. Elevation Compensation- E.C. orifices are also available, which provide constant outlet pressure even when inlet pressure fluctuates greatly. The elevation compensation orifice is a device which reduces changes in regulator outlet pressure due to change in inlet pressure. The E.C. orifice is recommended for installations where the inlet pressure may vary over a wide range. The E.C. orifice is available in two sizes: /8 x /6 (Part number 7698G006) and /6 (Part number 7698G005). Its capacity is the same as a standard orifice of the same size. Consult your American Meter Sales Representative for specific applications. 5" -5/" -9/6" Model B-90-5/" -5/" 5-5/6" 5" -5/" Model B-80-9/6" -/6" -/" 5-7/8"

B Service Regulators B Regulator Capacity Performance Capacity /" Outlet B Regulator Set Point 7.0" W.C. @ 50 SCFH SCFH 0.60 specific gravity gas @ 60 F &.7 PSIA. Pressure spring 7007P08. Outlet pressure variance not to exceed +" -" W.C. from set point, horizontal position. Inlet (PSIG) /8 /6 / 5/6 75 5 5 5 00 75 75 75 50 500 5 00 50 650 700 0 00 600 950 00 5 5 800 00 00 5 75 00 00 800 5 600 00 00 500 50 700 800 00 60 700 00 00 75 750 00 00 00 00 5 00 For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given orifice size. Capacity /" Outlet B Regulator Set Point PSIG @ 50 SCFH SCFH 0.60 specific gravity gas @ 60 F &.7 PSIA. Pressure spring 7007P085. Outlet pressure variance not to exceed +/- 0% from set point, horizontal position. Inlet (PSIG) /8 /6 / 5/6 75 00 50 50 5 5 75 5 50 0 75 50 50 75 5 5 50 75 500 5 5 75 650 750 5 50 600 850 000 50 75 700 00 00 60 600 850 00 00 75 700 000 00 800 00 900 00 5 000 For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given orifice size. Capacity " Outlet B Regulator Set Point 7.0" W.C. @ 50 SCFH SCFH 0.60 specific gravity gas @ 60 F &.7 PSIA. Pressure spring 7007P08. Outlet pressure variance not to exceed +" -" W.C. from set point, horizontal position. Inlet (PSIG) /8 /6 / 5/6 75 5 5 5 00 75 75 75 75 500 5 00 50 650 750 0 00 600 000 00 5 50 800 00 600 5 75 00 000 500 5 600 00 500 500 50 700 800 500 500 60 800 00 500 500 75 900 500 500 00 00 500 5 600 For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given orifice size. Capacity " Outlet B Regulator Set Point PSIG @ 50 SCFH SCFH 0.60 specific gravity gas @ 60 F &.7 PSIA. Pressure spring 7007P085. Outlet pressure variance not to exceed +/- 0% from set point, horizontal position. Inlet (PSIG) /8 /6 / 5/6 75 5 50 50 5 5 75 5 50 0 75 50 5 75 5 5 5 00 00 5 00 5 600 600 5 75 500 750 900 50 75 700 000 00 60 550 800 00 00 75 650 000 00 00 00 000 00 5 000 For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given orifice size.

B Service Regulators B Regulator Relief Valve Performance There are several methods of measuring the relief performance of a regulator. For the B service regulator, the worst case scenario will occur when the lever is disconnected. The data presented in the tables below represent this condition. 90 80 70 Outlet Pressure Relative To Inlet Pressure /" Screened Vent - No Vent Pipe Set Pressure 7" W.C. 5/6" /" /6" 90 80 70 Outlet Pressure Relative To Inlet Pressure /" Screened Vent - 0 Foot Vent Pipe with Elbows Set Pressure 7" W.C. 5/6" /" /6" Outlet Pressure - Inches W.C. 60 50 0 0 /8" Outlet Pressure - Inches W.C. 60 50 0 0 /8" 0 0 0 0 0 0 0 0 0 0 0 50 60 70 80 90 00 0 0 0 0 0 0 0 0 50 60 70 80 90 00 0 0 0 Inlet Pressure - PSIG Inlet Pressure - PSIG 9 8 Outlet Pressure Relative To Inlet Pressure /" Screened Vent - No Vent Pipe Set Pressure PSIG 5/6" 9 8 Outlet Pressure Relative To Inlet Pressure /" Screened Vent - 0 Foot Vent Pipe with Elbows Set Pressure PSIG 5/6" /" 7 /" 7 /6" Outlet Pressure - PSIG 6 5 /6" /8" Outlet Pressure - PSIG 6 5 /8" 0 0 0 0 0 0 0 50 60 70 80 90 00 0 0 0 0 0 0 0 0 50 60 70 80 90 00 0 0 0 Inlet Pressure - PSIG Inlet Pressure - PSIG 5

B Service Regulators Pressure Springs Outlet Pressure Color Code Part Number B.5" to 7" W.C. Light Blue 7007P08 5" to 9" W.C. Lavender 7007P08 6" to 5" W.C. Light Gray 7007P088 8" to PSIG Light Green 7007P085 Maximum Recommended Inlet Pressure Inlet Pressure (PSIG) /8" 5 /6" 5 /" 5 5/6" 00 to PSIG Pink 7007P086 to 5 PSIG Turquoise 7007P087 s Part Number B 5/6" 79P0 /" 79P0 /6" 79P0 /8" 79P00 For sizing downstream relief valves, use the following formulas to determine the regulator full open capacity: For critical flow rates Q = 0.5 C x P G For sub-critical flows Q = C P h G Full Open Regulator Relief Capacity Key: Q = Maximum capacity of regulator C = Orifice constant, see table P = Inlet absolute pressure (PSIA) P = Outlet absolute pressure (PSIA) h = Differential pressure (P - P) G = Specific gravity of gas Orifice C /8" 0 /6" 6 /" 80 5/6" 50 6

B Service Regulators Regulator Assembly Positions For 90 Models Valve Body Position "A" Valve Body Position "B" Valve Body Position "C" Valve Body Position "D" Regulator Assembly Positions For 80 Models Valve Body Position "A" Valve Body Position "B" Valve Body Position "C" Valve Body Position "D" 7

B Service Regulators Construction Lower Diaphragm Case - Precision die cast aluminum with a exclusive 7-step advanced conversion coating, single coat polyester primer and High Solid Polyurethane Top Coat. Top Assembly - Precision die cast aluminum with a exclusive 7-step advanced conversion coating, single coat polyester primer and High Solid Polyurethane Top Coat. Valve Body - Cast grey iron, undercoated, single coat polyester primer and High Solid Polyurethane Top Coat, (Rotates in 90 degree increments). Pressure Spring - Steel, Zinc plated and yellow chromate. Color coded for identification. Diaphragm Plate - Steel, terne plated. Seat Disc - Buna-N. Orifice - Super high strength, corrosion-resistant, aluminum. Lever - Stamped aluminum. Vent Screen - Stainless steel. Seal Plug - Ultraviolet stabilized, minlon. Corrosion Protection Ordering Information Model number. Size of inlet and outlet. Inlet pressure, psi. Outlet pressure, inches W.C. (or PSIG). 5 Flow, scfh. 6 Kind and specific gravity of gas. 7 Orifice size. 8 Regulator assembly position number. 9 Possible variation in inlet pressure for E.C. Orifice models. Maximum PSIG Minimum PSIG Shipping Weight - 8 lbs/carton of eight regulators Regulator Pressure Rating 5 PSIG = Maximum recommended inlet pressure for normal service. Maximum recommended pressure may vary with orifice size. 75 PSIG = Maximum inlet pressure for abnormal or emergency service, without causing damage to regulator case. 5 PSIG = Maximum outlet pressure for normal service. 0 PSIG = Maximum outlet pressure which can be contained by pressure carrying components (no flange leakage to atmosphere except for normal relief action). If regulator is subjected to these conditions, it should be removed from service. 50 PSIG = Maximum outlet pressure for abnormal service without damage to internal components. If regulator is subjected to these conditions, it should be removed from service. Due to continuous development the information in this document is subject to change. AMERICAN METER 00 Welsh Road, Building One " Horsham, PA 90- " USA " Tel: (5) 80-800 " Fax: (5) 80-890 CANADIAN METER 07 Derry Road, West " Milton, Ontario L9T X6 " Canada " Tel: (905) 878-6 " Fax: (905) 878-5758 8 PB/500/0-0 FP 0-96