SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Similar documents
S PRESSURE REGULATOR

Levante Sistemas de Automatización y Control S.L.

TYPE M PLUS TM PRESSURE CONTROL VALVES

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Hydraulic Live Swivels

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

FLANGED TWO-PIECE BALL VALVES

Index Table. Model 794. Installation, Operating and Maintenance Instructions

AIR INLINE METAL SHEAR

FLANGED TWO-PIECE BALL VALVES

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

FLEXAIR PNEUMATIC CONTROL VALVES

CSA Sample Draw Aspirator Adapter Operator s Manual

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Parts Manual. Frusheez Machines

WEATHERIZING INSTRUCTIONS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

RAM 4021 Operation Manual

Cylinder Tilt Saddle Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

User Instruction Manual

GALISO SOAP OPTION FOR PCT-ADW-D

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Pressure Relief Valve Instruction Manual

J Air and Water Kit Instructions Part# 02584

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

FLANGED MULTI-PORT BALL VALVES

DelVal Flow Controls Private limited

Color/Catalyst Dispense Valves

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

AIR HYDRAULIC RIVETER

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Model Series 62 Constant Differential Relay

CF-SERIES HIGH FLOW REGULATORS

453 Series Steam Heated Vaporizing Regulator

ORBITAL AIR SANDER. Owner s Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model No Product Name Handpiece Only Complete System

INSTRUCTIONS PARTS LIST

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Installation, Operation and Maintenance Manual for Back Pressure Regulator

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

ROPV R40 E Series User Manual

4-in-1 Professional Inflator Kit

D Series Air and Water Kit Part# 02550

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover)

3/8" Air Impact Wrench

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

TITAN FLOW CONTROL, INC.

1/2 in. Air Impact Wrench

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

Sterile Visual Flow Indicator

6500 KNIFE GATE VALVES

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

BS Series Basket Strainer

Switch Your Swivel! Hydraulic Live Swivels. Inline & 90 Swivels. 304 & 440c Stainless Steel Heavy Duty Ball Bearing, Rebuildable Design

Yoke Block Instruction Manual

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

ACCU-MIX 1200 / / 26270

Freedom8 ShoeBox Compressor Manual

Series IRV1000/2000/3000

Please Do Not Return This Product To The Store!

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

CS150 CAP STAPLER OWNER S MANUAL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Installation and Service Manual

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

This document to be used with Hurley traditional Davits

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

RG2200 BC Integrated Octopus

Hygienic Bubble Trap Installation and Operations Manual

OPERATION and MAINTENANCE Guide

Belt Sander. Owner s Manual

100C Air Compressor Kit

Sunset Swings By Health in Motion, LLC

MODELS 1500, 1520, 1530, 1560

3/8" Dr. Air Butterfly Impact Wrench

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

PERSONAL AIR BREATHING UNIT

Model 40H Nullmatic Pressure Regulators

Booster Regulator/Air Tank

IMPORTANT SAFETY INSTRUCTIONS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

MECH-TECH SYSTEMS CCU MODEL FOR GLOCK PISTOLS

Transcription:

SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate through six or seven predetermined positions of ½ (12.7 mm) increments with total strokes of 2½ (63.5 mm) or 3 (76.2 mm) respectively. They were primarily designed for power-shift transmissions but may also be utilized for indexing and any other application where fixed stroke increments are required. The ideal companion valve for these cylinders is Type "P" six or seven position Rotair Valve. An alternative control is an electropneumatic switching circuit using 3-way solenoid valves. These cylinders are extremely rugged having anodized, corrosion resistant, lightweight aluminum body, pistons and pistons stops. WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices. INSTALLATION! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic or hydraulic systems and devices, unless under trained supervision. Compressed air and hydraulic systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust or drain the pressure from a system before performing any service work. Failure to do so can result in serious personal injury. MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. INSTALLATION Mount the cylinders in any desirable plane to a sturdy, flat surface (preferably with the ports facing down) with three 3/8" bolts. Mounting lugs are cast in the body of the cylinders. Avoid misalignment with the load to be positioned since side thrust and binding will affect the service life of the rod bearing and piston stop seals. All ports are 1/4-18 NPT. The following ports should be piped together with "T" connections: 3 with 3A on the six position cylinder, 3 with 3A and 6 with 6A on the seven position cylinder. Connections should be made as close to the cylinder as possible to reduce the number of lines from the control valve. OPERATION Maximum operating pressure is 150 psi (10 bar) within a temperature range of -40 to 200 F (-40 to 93 C). The cylinder piston rod reaches its various positions in response to pressure being supplied to the cylinder ports as shown in the truth tables on NOTE: P Rotair Valve R431006324 (P -063984-00000) was designed to control six position cylinder R431006322 (P-063982-00001) and valve R431006326 (P -063985-00000) was designed to control seven position cylinder R431006321 (P -063981-00002). Both of these Rotair Valves have first gear position adjacent to neutral and progress toward full automatic at the extreme position of valve handle travel Rotair Valves can be made available to have the handle position sequence identical to the transmission. Six position Rotair R431006324 (P -063984-00000) should be connected as follows: Ports No. 1 and No. 5 plugged, Exhaust port is 1/8 NPT, pressure is supplied to unnumbered port in the side of the pipe bracket, valve port No. 2 to cylinder port No. 2, valve No. 4 to cylinder No. 5, valve No. 3 to cylinder No. 3 & 3a, and valve port No. 6 to cylinder port No. 6A in six position cylinder R431006322 (P -063982-00001). Seven position Rotair R431006326 (P -063985-00000) should be connected as follows: port No. 1 plugged, exhaust port No. 4, pressure is supplied to unnumbered port in the side of the pipe bracket, valve port No. 2 to cylinder port No. 2, valve No. 5 to cylinder No. 5, valve No. 3 to cylinder No. 3 & No. 3A and valve port No. 6 to cylinder No. 6 & 6A in seven position cylinder R431006321 (P -063981-00002). pages 3 and 5. V means air must be vented to atmosphere, S means air must be supplied and S/V means port can be supplied or vented. whichever is most convenient in the control valve. Each cylinder has reverse at full extended position of the rod and is spring returned to neutral (next position in from reverse) from any position. The transmissions which these cylinders usually control have the full automatic or drive position adjacent to neutral. The corresponding position is 5 on the seven position and 4 on the six position cylinder. The sequential order of cylinder positions is a function of the "P" Rotair Valve. The forces developed by the cylinder are functions of the air pressure applied to the exposed piston areas and are tabulated for rod movement to the various stroke positions as shown on the charts on pages 6 and 7. The internal spring returns the piston rod to its Neutral position when air pressure is intentionally or unintentionally exhausted from all control lines. This safety feature returns the transmission to neutral if the air supply is lost. MAINTENANCE Periodically disassemble the cylinder for cleaning and inspection. Clean all metal parts with a nonflammable solvent and wash all rubber parts with soap and water. Rinse thoroughly and dry, using low pressure jet, if available. Replace all damaged or worn parts. Reassemble the cylinder, lubricating each part as it is put in place. Rubber parts should be lubricated with Dow Corning No. 55 pneumatic grease. Check the operation of the reassembled cylinder by putting low pressure air in the ports in accordance with the truth table, pages 3 and 5. NOTE: When disassembling a cylinder, please use CAUTION as the return springs are under compression. ADJUSTMENT AVENTICS six and seven positions require no adjustment. SM-1000.4905

EXPLODED VIEW Six Position R431006322 (P 063982-00001 Page 2

SIX POSITION CYLINDER PARTS LIST M-4-N-1B CYLINDER P/N R431006322 (P -063982-00001) DWG. NO. CP63982A ITEM NO. QTY. DESCRIPTION NEW P/N OLD P/N 1 4 SCREW, 1/4 X 20 X 3/4 CAP R431002203 P -049856-00046 2 1 PISTON 2 7/8 R431002303 P -064175-00000 *3 1 O-RING, 2 3/4 See Kit See Kit *4 2 O-RING, 2 O.D. See Kit 5 1 PISTON, 2 REAR R431006371 P -064184-00000 6 1 BODY, CYLINDER R431006377 P -064193-00000 7 1 SCREW, CAP HEX, HEAD R431002232 P -049832-00078 8 1 WASHER, LOCK 5/16 R431002572 P -049982-00006 *9 1 PISTON, 1 3/4 R431006374 P -064189-00000 *10 1 O-RING, 1 3/4 O.D. See Kit *11 3 O-RING, 11/16 O.D. See Kit 12 1 PISTON, 2 FRONT R431006909 P -066884-00000 13 1 PISTON, 1 5/8 R431006365 P -064172-00000 *14 1 O-RING, 1 1/2 O.D. See Kit 15 1 PISTON 2 7/8 R431006910 P -066885-00000 *16 1 O-RING, 2 7/8 O.D. See Kit *17 1 O-RING, 3 3/8 O.D. See Kit *18 1 O-RING, 1 5/8 O.D. See Kit 19 1 RING, RET. 1 5/8 R431002387 P -049882-00010 20 1 HOUSING, BUSHED SPRING R431000896 P -028264-00001 21 1 SPRING R431006375 P -064191-00000 22 1 ROD, PUSH COMPLETE R431006563 P -065103-00001 23 1 RETAINER, SPRING R431006908 P -066883-00000 24 1 BUSHING R431006366 P -064173-00000 *25 1 WIPER, ROD 1/2 See Kit 26 4 SCREW, CAP 1/4-20X1 R431002303 P -049856-00046 Recommended Spare Parts - *Packing Repair Kit P/N R431006546 (P -064997-00001) Spring P/N R431006375 (P -064191-00000) CONDITION OF PORTS CYLINDER POSITION CAVITY 3 2 5 3A 6A R S V S V V V N S V V V V V 4 S V V V V S 3 S V V V S V 2 S V S S V S V 1 V V S S V S V S SUPPLIED V VENTED Page 3

EXPLODED VIEW Seven Position R431006321 (P 063981-00002 Page 4

SEVEN POSITION CYLINDER PARTS LIST M5-N-1B P/N R431006321 (P -063981-00002) DWG. NO. CP63981A ITEM NO. QTY. DESCRIPTION NEW P/N OLD P/N 1 1 CAP R431006372 P -064186-0000 2 1 ROD, REAR PISTON R431006373 P -064188-0000 3 1 PISTON, 2 1/4 R431006376 P -064192-0000 *4 12 O-RING, 2 1/4 O.D. See Kit See Kit *5 1 O-RING, 5/8 O.D. See Kit See Kit *6 2 O-RING, 2 3/4 O.D. See Kit See Kit *7 1 O-RING, 2 O.D. See Kit See Kit 8 1 PISTON, 2 REAR R431006370 P -064183-00000 9 1 BODY, CYLINDER R431006377 P -064193-00000 10 1 SCREW, CAP HEX. HEAD R431002232 P -049832-00078 11 1 WASHER, LOCK 5/16 R431002572 P -049982-00006 12 1 PISTON, 1 3/4 R431006374 P -064189-00000 *13 13 O-RING, 1 3/4 O.D. See Kit See Kit *14 1 O-RING, 11/16 O.D. See Kit See Kit 15 1 PISTON, 2 FRONT R431006909 P -066884-00000 16 1 PISTON, 1 5/8 R431006365 P -064172-00000 *17 1 O-RING, 1 1/2 O.D. See Kit See Kit 18 1 PISTON, 2 7/8 R431006910 P -066885-00000 *19 1 O-RING, 1 7/8 O.D. See Kit See Kit *20 1 O-RING, 3 3/8 O.D. See Kit See Kit *21 1 O-RING, 1 5/8 O.D. See Kit See Kit 22 1 RING, RET. 1 5/8 R431002333 P -049857-00007 23 1 HOUSING, SPRING R431000896 P -028264-00001 24 1 SPRING R431006375 P -064191-00000 25 1 ROD, PUSH COMPLETE R431006562 P -065103-00000 26 1 RETAINER, SPRING R431006908 P -066883-00000 27 1 BUSHING R431006366 P -064173-00000 *28 1 WIPER, ROD 1/2 See Kit See Kit 29 2 RING, RET. 1/2 R431002333 P -049857-00007 30 8 SCREW, CAP 1/4-20X1 R431002303 P -049856-00046 Recommended Spare Parts - *Packing Repair Kit P/N R431006546 (P -064997-00001) Spring P/N R431006375 (P -064191-00000) ASSEMBLY VIEW CONDITION OF PORTS CYLINDER CAVITY POSITION 6 3 2 5 3A 6A R S V S V S V V V N S V S V V V V V 5 S V S V V V V S 4 S V S V V V S V 3 S V S V S S V S V 2 S V V S S V S V 1 V V V S S V S V S SUPPLIED V VENTED Page 5

SIX POSITION CYLINDER Page 6

SEVEN POSITION CYLINDER Page 7

NOTICE TO PRODUCT USERS 1. WARNING: FLUID MEDIA AVENTICS pneumatic devices are designed and tested for use with filtered, clean, dry, chemical free air at pressures and temperatures within the specified limits of the device. For use with media other than air or for human life support systems, AVENTICS must be consulted. Hydraulic cylinders are designed for operation with filtered, clean, petroleum based hydraulic fluid; operation using fire-resistant or other special types of fluids may require special packing and seals. Consult the factory. 2. WARNING: MATERIAL COMPATIBILITY Damage to product seals or other parts caused by the use of noncompatible lubricants, oil additives or synthetic lubricants in the air system compressor or line lubrication devices voids AVENTICS warranty and can result in product failure or other malfunction. See lubrication recommendations below. AIR LINE LUBRICANTS! In service higher than 18 cycles per minute or with continuous flow of air through the device, an air line lubricator is recommended.* (Do not use line lubrication with vacuum products.) However, the lubricator must be maintained since the oil will wash out the grease, and lack of lubrication will greatly shorten the life expectancy. The oils used in the lubricator must be compatible with the elastomers in the device. The elastomers are normally BUNA-N, NEOPRENE, VITON, SILICONE and HYTREL. AVENTICS recommends the use of only petroleum based oils without synthetic additives, and with an aniline point between 180 F and 210 F. COMPRESSOR LUBRICANTS! All compressors (with the exception of special "oil free" units) pass oil mist or vapor from the internal crankcase lubricating system through to the compressed air. Since even small amounts of non-compatible lubricants can cause severe seal deterioration (which could result in component and system failure) special care should be taken in selecting compatible compressor lubricants. 3. WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices. NSTALLATION! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic or hydraulic systems and devices, unless under trained supervision. Compressed air and hydraulic systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust or drain the pressure from a system before performing any service work. Failure to do so can result in serious personal injury. MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. 4. WARNING: APPLICATION AND USE OF PRODUCTS The possibility does exist for any device or accessory to fail to operate properly through misuse, wear or malfunction. The user must consider these possibilities and should provide appropriate safe guards in the application or system design to prevent personal injury or property damage in the event of a malfunction. 5. WARNING: CONVERSION, MAINTENANCE AND REPAIR When a device is disassembled for conversion to a different configuration, maintenance or repair, the device must be tested for leakage and proper operation after being reassembled and prior to installation. MAINTENANCE AND REPAIR! Maintenance periods should be scheduled in accordance with frequency of use and working conditions. All AVENTICS products should provide a minimum of 1,000,000 cycles of maintenance free service when used and lubricated as recommended. However, these products should be visually inspected for defects and given an "in system" operating performance and leakage test once a year. Where devices require a major repair as a result of the one million cycles, one year, or routine inspection, the device must be disassembled, cleaned, inspected, parts replaced as required, rebuilt and tested for leakage and proper operation prior to installation. See individual catalogs for specific cycle life estimates. 6. PRODUCT CHANGES Product changes including specifications, features, designs and availability are subject to change at any time without notice. For critical dimensions or specifications, contact factory. *Many AVENTICS pneumatic valves and cylinders can operate with or without air line lubrication; see individual sales catalogs for details. LIMITATIONS OF WARRANTIES & REMEDIES AVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following: For twelve months after shipment AVENTICS will repair or replace (F.O.B. our works), at its option, any equipment which under normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser. No charge will be made for labor with respect to defects covered by this Warranty, provided that the work is done by AVENTICS or any of its authorized service facilities. However, this Warranty does not cover expenses incurred in the removal and reinstallation of any product, nor any downtime incurred, whether or not proved defective. All repairs and replacement parts provided under this Warranty policy will assume the identity, for warranty purposes, of the part replaced, and the warranty on such replacement parts will expire when the warranty on the original part would have expired. Claims must be submitted within thirty days of the failure or be subject to rejection. This Warranty is not transferable beyond the first using purchaser. Specifically, excluded from this Warranty are failures caused by misuse, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts. This Warranty also excludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products. This Warranty sets out the purchaser's exclusive remedies with respect to products covered by it, whether for negligence or otherwise. Neither, AVENTICS nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred by reason of the use or sale of such products. Our liability (except as to title) arising out of the sale, use or operation of any product or parts, whether on warranty, contract or negligence (including claims for consequential or incidental damage) shall not in any event exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is terminated. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. No attempt to alter, amend or extend this Warranty shall be effective unless authorized in writing by an officer of AVENTICS Corporation. AVENTICS reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without notice. Page 8