BUBBLER CONTROL SYSTEM

Similar documents
BUBBLER CONTROL SYSTEM

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

Aquavar SOLO 2 Frequently Asked Questions

Stand-Alone Bubble Detection System

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

HumiSys HF High Flow RH Generator

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Operation & Maintenance Manual GDS-68XP

Valve Proving System VDK 200 A S06*

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Valve Proving System VDK 200 A S02

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

ACV-10 Automatic Control Valve

LVU2800 Series. Ultrasonic Level Transmitter

Burner Management System DEMO Operating instructions

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Inert Air (N2) Systems Manual

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

RAM 4021-DPX Operation Manual

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Touch Screen Guide. OG-1500 and OG Part # T011

Built-in Purge Control Functions

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

SCIENCE LAB UTILITY CONTROLS

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

A TECHNICAL REFERENCE

Model 601CV. Mass Flow Controller. Product Features:

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Universal Valve Company Inc

SPECIFICATIONS ATTENTION

Universal Valve Company Inc

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

NGP-250/500 Nitrogen Generator Quick Start Guide

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Overview. Front Panel: Keypad and Display

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

CCT-7320/ROC-2313 Reverse Osmosis Controller

AX5000 Operational Manual

Autocalibration Systems For In Situ Oxygen Analyzers

Design Envelope Booster. Sequence of operation

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Reverse Osmosis System Installation Guide and Operation Manual.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CHILLER CONTROL PANEL PROGRAMMING AND DATA ACCESS

Installation and Operation Manual

780S Ultra High Purity Series

R E D I C O N T R O L S

Model 130M Pneumatic Controller

Standard Chiller 1/4 compressors Manual version: /10/96

Automatic Valve Proving Control

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MP15 Jockey Pump Controller

Instruction Manual. Biogas Analyzer InCa Bio 04

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Fully Automatic Gas Manifold. Patent US 7,013,906. Installation & Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MONSOON 6V Pump Control System

Valve Communication Solutions Axiom

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

HBLT-A1 LIQUID LEVEL SENSOR

2.2.2 Instructions Specific to Hazardous Area Installations... 13

Quick Installation Guide Doc nr.: C Date:

RAM Operation Manual

For Multi-Parameter Meters see mvx

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

Ventam 85 Installation & Commissioning Instructions

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

For Multi-Parameter Meters see mvx

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

BI-680 Online Dissolved Oxygen Controller Instruction Manual

IMVS2000v2 INSTALLATION OPERATING MANUAL MAN720. Integrated Monitoring Valve System. Copyright by BIFFI ITALIA. All rights reserved.

MACON R70 FOR 1 OR 2 COMPRESSORS

OC Panel High Limit Aquastat Kit, Manual Reset p/n

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

Royce Interface Level Analyzer and Sensors

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

TECHNICAL DATA. Q = C v P S

AUTO PUMP STATUS CENTER

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SINGLE VALVE WITH LOW-FLOW BYPASS

VARIOspeed 3R User Manual

Control units. Installation and operating instructions Series: DP-Control

Operating instructions. FOCUS compressor control for piston compressors

Transcription:

BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air tank, bubbler line purge, air tank moisture drain (automatic), system status indications, tank air pressure indication, level indication, alarm outputs as well as tank air pressure signal output and level signal output. The standard style design comes prefabricated on mounting channels with the air compressors and air tan tank external to the bubbler control panel. Optional all integral units are also available. The bubbler system works by pumping regulated air (flow controlled) down a tube that has one end submerged in liquid, then liquid level is determined using a pressure transducer that measures the pressure required to force air through the bubbler tube. Standard Features: 120VAC input power Internal fuses, solenoid, operator interface terminal, controller, and 24VDC power supply. Air compressors, oil-less type, 120VAC, 100PSI maximum continuous pressure Air pressure regulator with filter (20-130PSI, factory set at 25PSI) Bubbler air pressure regulators (4-57PSI, factory set at 10PSI) Pressure transmitter (for wet well level) with ±0.2% full scale accuracy 4-20mA output proportional to level 4-20mA output proportional to tank air pressure Analog output adjustments Re-ranging of analog inputs, air tank pressure and wet well level. This feature allows the end user to install pressure transmitters with different operating range. Compressor on/off setpoint settings. Automatic compressor alternation upon compressor failure Air compressor safe mode which limits the continuous run time of each of the air compressor. This is a factory set features which is determined during the factory test and commissioning of the individual system. Attempts to clear clogged bubbler tube before alarming Freezes level analog output during purging Automatic bubbler line purge and air tank drain cycle performed at an interval of 6 hours (factory set). The time interval is field adjustable. Pushbutton for manual purge Pushbutton for alarm reset Graphical indication for: o Wet well level o Air tank pressure o Compressor running o Compressor run time o System purging o Air tank moisture drain active o Air compressor failure o Clogged bubbler tube indication Output relay contacts for Bubbler system common fault (standard) with optional: o High wet well level o Low wet well level o Air compressor 1 alarm o Air compressor 2 alarm o Air tank low pressure alarm Standard Communications: RS-232 (RJ12) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud, RS-485 (3-wire terminal block) port with Modbus RTU Master/Slave and ASCII In/out protocol(s) at up to 115.2k baud.

Specifications: Input Power: 120VAC ±10%, 60Hz Skid dimensions 76 H X 14.63 W X 24.28 D Ambient Operating Temperature: 40ºF to 140ºF normal, -28ºF to 140ºF with optional heater Storage Temperature: -4ºF to 140ºF Operator Interface Terminal: 3 liquid crystal display Output relay contacts: 12A @ 28VDC or 250VAC Analog Output: 4-20mA, non-isolated Analog Output Range Analog Input: 4-20mA, non-isolated Air Storage Tank Pressure Rating: 200PSI Max Model Selection Base model: HDBCS-AIN4CSCMTLP Incoming Voltage: A : 120VAC System Design: I : Integral Air Compressors Enclosure Type: N4 : NEMA 4 Output Signal Type: C : 4-20mA Relay Output Options: S : Standard Relay Output Options: CM : Air Compressors Malfunction Relay Output Options: TLP : Air Tank Low Pressure Operating Voltage: A : 120VAC System Design: I : Integral Air Compressors P : Plant/External Air A : Bubbler, compressors, and tank housed inside the enclosure Enclosure Type: O : Open N1 : NEMA 1 N12 : NEMA 12 N4 : NEMA 4 N3R : NEMA 3R 4XF : NEMA 4X, Fiberglass 4XP : NEMA 4X, Polycarbonate 4X4 : NEMA 4X, 304 Stainless Steel 4X6 : NEMA 4X, 316 Stainless Steel Output Signal Type: C : 4-20mA V : 0-10VDC Relay Output Option: S : Bubbler System Common Fault X : Loss of Plant/Eternal Air Alarm WLA : High and Low Wet Well Level Alarms CM : Air Compressors Malfunction TLP : Air Tank Low Pressure Alarm ALL : Bubbler System Common Fault, High and Low Wet Well Level Alarms, Air Compressor 1 and 2 Malfunction (one per compressor), and Air Tank Low Pressure Alarm

System Status and Indications (LCD) Compressor Run Indication: Shows which compressor is being called to run. Compressor Run Time: The system keep track of the run time for each of the compressors. This serves as a diagnostic in order to detect early compressor failure. The run time should be very much equal between the two compressors and if at any time any of the two run times seems to be out of the ordinary, then that compressor needs to be considered as a future failure. Note that the run times are field resettable. Compressor Alarm Indication: Shows which compressor is in alarm. This particular alarm is generated when the running compressor fails to bring the tank pressure up the lead off set point. In normal operation, the compressor runs for a period of 1 minute in order to bring the pressure to the lead off set point. If the pressure does not rise up to the lead off set point within a period of 1.5 minutes, the respective compressor is immediately turned off, the respective compressor alarm indication is turned on, and the other compressor is call to run and made the lead. The new lead compressor remains as the lead and the alarm indication stays active until the reset button is pressed or until main power is cycled. Note that a failed air compressor is taken out of the lead lag sequence. Both, the respective compressor alarm output relay and Bubbler System Common Fault relay are energized upon activation of this alarm. Air Compressor System Failure: This alarm indicates a major failure with the air compressor system portion and couple of scenarios can generate this alarm: 1. A sudden drop of system pressure: pressure drops in matter of seconds. This indicates a major air leak or a pressure sensor failure. Before this alarm is generated, the system, by nature, will operate the compressors. This alarm will remain active until the reset button is pressed and tank pressure goes back to normal or if power is cycled. 2. When both air compressors fail, see Compressor Alarm Indication above. 3. An air compressor signal loss alarm which is generated when the air tank pressure transmitter loses power. If sensor ever needs replacing, the operator can place this particular alarm into standby mode which can then be disabled or automatically disabled after a period of 10 minutes.

Clogged Bubbler Tube Alarm: In normal operation, the water level rises and falls in a similar pattern. If the level rises and continues to rise until the detected level rises up near the max range, it is then assumed that the bubbler line is clogged. A purge/dump cycle is initiated the first time this condition occurs but the alarm is yet not activated. In doing so, the system is given a chance to clear the clog before the alarm is generated. If the condition is detected again within the next 20 minutes, the Clogged Bubbler Tube alarm is generated and the system performs another purge/dump cycle. The system will perform three more purge/dump cycles at 10 minutes interval in an attempt of clearing the clog. This alarm indication will remain active until the alarm reset push button is pressed or until main power is cycled. The Bubbler System Common Fault relay is energized upon activation of this alarm. Purge/Dump Cycle: A purge/dump cycle is displayed while the cycle is being executed. Wet Well Level Indication: The water elevation is displayed as a graphical representation as well as numerical. Air Tank Pressure Indication: The air tank pressure is displayed as a graphical representation as well as numerical. High and Low Wet Well Alarms: These are field adjustable settings. The High Wet Well Level alarm is generated when the water level increases to the high wet well level alarm set point. The Low Wet Well Level alarm is generated when the water level decreases to the low wet well level alarm set point. The alarms remain active until the reset pushbutton is pressed. Both, the respective alarm output relay (High or Low Wet Well Level) and Bubbler System Common Fault relay are energized upon activation of either alarm. Air Compressors in Backup Mode: This alarm is activated when the pressure in the air storage tank drops below the set point as detected by the pressure transducer mounted on the air storage tank. Upon activation of this alarm, the controller will automatically switch controls to the air storage tank pressure transducer and serves as backup to the normal control mode (pump pressure switch). A compressor will be called to run after a preset time delay elapses (factory set to 10 seconds). The compressors work in the same order as when operating in normal control mode but call to run commands are determined by the pressure transducer instead of the pump pressure switch. Lead, lag, and alternation are operational when operating in backup mode. Note that the Air Compressor in Backup Mode alarm will be activated until the reset pushbutton is pressed or until power is cycled. Air Tank Low Pressure Alarm: This is a field adjustable setting. This alarm is activated when the pressure in the air storage tank drops below the set point, as detected by the pressure transducer mounted on the air storage tank. This is an indication that the Backup Mode failed to build up the pressure inside the air storage tank and the condition becomes a true alarm after the elapsed time of five minutes. Pushbuttons Functionality: Alarm Reset: Pressing the button causes all present alarms to clear. Manual Purge: Purge/dump cycle is initiated upon pressing this button. The cycle will initiate if either the Compressor System Failure alarm or Clogged Bubbler Tube alarm is active. Lead On/Off Setpoint: This will be used to maintain a constant air pressure inside the storage tank and it is enabled when an Air Compressors in Backup Mode alarm is activated. Note that normal mode of operation is from the pump pressure switch mounted on the air storage tank.

Air Tank Pressure Settings: It is used to enter the engineering range of the pressure transmitter that measures air tank pressure, min and max engineering values. This range will be the same range used for the corresponding analog output. Wet Well Pressure Transmitter Settings: It is used to enter the engineering range of the pressure transmitter that measures air pressure in the bubbler line, min and max engineering values. The pressure value is proportional to the water level. Wet well offset values can be entered in this screen as well as setting the analog out range which correspond to wet well level. Purge/Dump Time Interval: factory set to 8 hours. This is the time interval at which purging is to occur. It is field adjustable. LCD Operating Screens: 1. Settings Screen: This screen is used to properly set the operating parameters. a. Air Tank Pressure b. Well Pressure Transmitter: c. High and low wet well level alarms setpoints d. Compressor on/off setpoints e. Time interval at which purging is to occur f. Compressor run time reset. 2. Home Screen (Displays): a. Wet well level b. Air tank pressure c. Compressor running d. Compressor Run Time e. Purge/Dump active f. System alarm (when active, the alarm screen must be accessed in order to see actual alarm) 3. Alarm Screen (Displays): a. Wet well high level alarm b. Wet well low level alarm c. Compressor 1 malfunction d. Compressor 2 malfunction e. Air Compressors in Backup Mode f. Air tank low pressure alarm g. Air Compressor System Failure h. Clogged bubbler tube alarm i. Air tank pressure signal lost alarm j. Wet well signal lost alarm

Level Measurement Range Note that level measurement is not done with the entire depth of the wet well. The distance from the end of the bubbler tube to the highest measured point in the well provides the actual level measurement range. See sample below. Bubbler Control Panel View: BUBBLER PANEL MANUAL PURGE ALARM RESET Note: The above panel is typical of NEMA 12 type enclosures. The front layout will be the same for different types enclosures included but not limited to NEMA 1, 3R, 4X Stainless Steel, 4X Polycarbonate, and 4X Fiberglass. The front door mounted components are: 1. 3 Graphical display terminal which is used for displaying status and indications, and for system settings. 2. Manual purge button which is used to manually initiate a purge/dump cycle. 3. Alarm reset button which is used to reset system related alarms.

Pluming Diagram Note: Pumping diagram is typical of the bubbler system with integral air compressors option. BUBBLER PANEL MANUAL PURGE ALARM RESET FLOW INDICATOR/ REGULATOR PRESSURE TRANSDUCER PRESSURE REGULATOR PURGE VALVE PURGE VALVE AIR COMPRESSOR 1 AIR COMPRESSOR 2 LOW PRESSURE SWITCH PUMP SWITCH PRESSURE GAUGE PRESSURE REGULATOR 5GAL AIR RECEIVER DRAIN VALVE