MICROWAVE ANTENNAS KS HORN-REFLECTORAND WAVEGUIDE SYSTEM INSTALLATION ANTENNA ASSEMBLY

Similar documents
FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

CO2 Tank Conversion Kit P.N , P.N , and P.N

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

OPERATING INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

100C Air Compressor Kit

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pressure Dump Valve Service Kit for Series 3000 Units

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

GM Series Dual-Block Multi-Function Gas Control Valves

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

36H SERIES Combination Gas Valve

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Steel Spring Driven Reel Instruction Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 Pressure-Reducing Regulator User Manual

Pressure Dump Valve Service Kit for Series 2300 Units

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

RD(H)20/25 Pressure-Reducing Regulator User Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Operation Manual Piston Sensed Gas Pressure Regulators

Instruction Manual Updated 7/26/2011 Ver. 2.2

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

TEST SPECIFICATION NYT-909-C

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

PAPR Flow Tester. instructions. part no WARNING

Gas Conversion Kit Pilot Ignition Heaters

Techcon Systems TS1254 Pressure Pot

Type ACE95jr Tank Blanketing Valve

DBML-60/80 Squeeze Tool

444C DUAL PERFORMANCE VALUE PACK

INSTRUCTION MANUAL. January 23, 2003, Revision 0

OPERATION MANUAL NTF-15

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

TECHNICAL DATA. Page 1 of 12

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Carter Option X Valve connector assembly. Maintenance manual

TECHNICAL DATA. Q = C v P S

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Installation, Operation and Maintenance Manual for Back Pressure Regulator

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Engineering Data Sheet

DS06D,G Dial Set Pressure Regulating Valve

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

3/8" Dr. Air Butterfly Impact Wrench

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

Installation and Service Manual

Torque Specifications

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

400C & 450C DUAL PERFORMANCE VALUE PACKS

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Operator: Save these instructions for future use!

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Halsey Taylor Owners Manual

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Baron Oxygen STC Installation Instructions (Front Baggage Installation) GAMI/Tornado Alley Turbo 2009

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

DUAL 444C ONBOARD AIR SYSTEM

CSA Sample Draw Aspirator Adapter Operator s Manual

TECHNICAL DATA. Q = C v P S

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Model PSI Compressor with 3-Gallon Air Tank 12VDC

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

FLEXAIR PNEUMATIC CONTROL VALVES

Techcon Systems TS1258 Pressure Pot

SECTION BUTTERFLY VALVES

G96 Series BASOTROL Dual Operator Valve

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Installation, Operation, and Maintenance Manual

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

INSTRUCTION MANUAL Pressure Relief Device LPT

V-24 OXYGEN LANCE VALVE

VERTICAL BLADDER TANK

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

TECHNICAL DATA CAUTION

Transcription:

BELL SYSTEM PRACTCES AT&7Co Standard SECTON 40-41-01 ssue 5, September 1975 MCROWAVE ANTENNAS KS-15676 HORN-REFLECTORAND WAVEGUDE SYSTEM NSTALLATON ANTENNA ASSEMBLY CONTENTS l. GENERAL............ METHOD OF ASSEMBLY...... UNCRATNG.......... NSPECTNG.......... ATTACHNG THE KS-15676, LST 3 FEED HORN............ 3. ANTENNA LEAKAGE TEST..... 4. LEAKAGE TEST FOR NSTALLED ANTENNA..............., 5. NSTALLNG THE 14-EDGE BLNDERS AND SUPPORTS........... 1. GENERAL PAGE 1.01 This section pertains to the assembly of the KS-15676, L9BC, L9BD, L14BC, and L14BD horn-reflector antennas used for the 4-, 6-, and 11-GHz Radio Relay Systems. The following items are covered in this section: (a) KS-15676, L9BC and L14BC horn-reflector antennas (b) KS-15676, L9BD and L14BD horn-reflector antennas (c) KS-15676, L4 mounting base (d) KS-15676, L3 feed horn (e) KS-15676, Lll antenna mounting clamp assembly. 1 8 a 1.0 This section is reissued to delete all references to the List 8 antenna and to incorporate the latest changes made to the KS-15676 antenna. The new versions are coded KS-15676, List 9BC, 14BC, 9BD, or 14BD. Since this is a major revision, the arrows normally used to indicate changes have been omitted. This issue does not affect the Equipment Test List. 1.03 The antennas are shipped lying on a side attached to a shipping skid. The overall dimensions of the antenna and skid are approximately 19 feet 10 inches long by 11 feet 6 inches high by 7 feet 8 inches deep with a weight of approximately 3500 pounds. All major subassemblies are furnished with the antenna. They include the List weather cover, List 5 mounting frame, List 7 sealant kit, and four List 11 mounting clamps. A box of miscellaneous hardware is also furnished with the antenna. 1.04 The List 9BC is the basic horn-reflector antenna assembly. The List 14BC is a factory-assembled hardened version of the List 9BC antenna. Hardening is accomplished by adding an external aluminum skin to the existing structure. The lower edge of the window opening is also reinforced. The List 9BD and 14BD are identical to the List 9BC and 14BC when received. Additional equipment (14-edge blinders and blinder support assemblies) is furnished with the List 9BD and List 14 BD antenna. These assemblies are attached to the shipping skid and must be added to the antenna in the field. These assemblies are secured to the antenna along the right and left sides of the window opening. They are bolted to the side panel assemblies and the weather cover clamping angles. The lower edge is supported with a blinder support and is bolted to the blinder and the front weather cover clamping angle. 1.05 The assembled antenna, List 9BC, is shown in Fig. 1. t consists of a paraboloidal @ American Telephone and Telegraph Company, 1975 Printed in U.S.A. Page 1

SECTON 40-41-01 reflector mounted in the top of a pyramidal horn. A window or weather cover is fastened to the horn antenna in front of the reflector. This antenna is supported on trunnions in a square mounting frame. A tilt adjustment assembly between the back of the antenna and the square mounting frame provides for adjustment of the elevation angle of the antenna. The mounting frame is equipped with four brackets, each provided with two threaded studs with jam nuts. Tie-angle assemblies are attached to each of the four corners of the antenna horn at the mounting frame level. The antenna is adjusted in elevation by means of the tilt adjustment assembly, after which the studs in each bracket are turned into contact with the antenna tie-angle assemblies and locked with the jam nuts provided. This arrangement serves to lock the antenna against vertical movement in the mounting frame. Azimuth adjustment of the antenna is accomplished by means of the List 17 tool. Section 40-41-0 covers the use of this tool. The antenna is held in its final azimuth position by four List 11 clamps which fasten the List 5 mounting frame to the List 4 mounting base as shown in Section 40-41-0.. METHOD OF ASSEMBLY.01 The assembly procedures for a List 9BC or 14BC antenna will consist of uncrating, inspecting the antenna for any damage that might have occurred during shipping, attaching the List 3 feed horn, and pressure testing the antenna. The assembly procedures for a List 9BD or 14BD consist of uncrating, inspecting, attaching the List 3 feed horn, pressure testing, securing the 14-edge blinders and supports, and repressure testing the antenna. UNCRATNG.0 Remove the protective covering with which the antenna was shipped. Remove the wood protective panel from the face of the antenna. Unbolt the antenna from the shipping skid. Uncrate the miscellaneous hardware. Remove the 14-edge blinders and supports from the shipping skid. Remove the protective wood cover from the narrow end of the antenna. NSPECTNG.03 nspect the antenna for any obvious damage that might have occurred during shipping. nspect the interior of the antenna for the presence of water or, in cold weather, ice or frost. f moisture in any form is present, it must be removed before the feed horn is installed. A standard ventilating heater, as covered in Division 649 of the Bell System Practices, may be used to melt ice and speed drying. ATTACHNG THE KS-1 5676, LST 3 FEED HORN.04 Clean the surface of the four bottom flange angles of the antenna using trichloroethane and clean rags. f necessary, fill out any unevenness at the four corners of the flange angles with EC-116 sealer material. Remove the l/4-inch plywood protective cover from the large end of the List 3 feed horn. Clean the surface that will mate with the bottom flanges of the antenna with trichloroethane and clean rags..05 Place the sealer strip assembly on the feed-! horn flange 1/16 inch from the inside edge of the opening. Apply the strips with the black rubber against the feed-horn flange, the wire mesh towards the inside edge, and the rubber towards the bolt holes. Miter the corners of each strip to obtain tight joints. Do not overlap the strips. (See Fig..). Caution: The surfaces which the seals will be in contact w th must be clean and free from any moisture. Do not apply the sealer strip assembly when the air temperature wi thin 1 foot of the metal is less than 40 degrees F..o6 Secure the feed horn to the antenna using the 3/8 by 1-3/4 inch bolts as shown in Fig.. Apply a coating of KS-19094 antiseize compound to the threads of all bolts and nuts before using. Tighten the bolts and nuts to a torque of 60 foot-pounds. Caution: n order to prevent possible damage to the seaj, avoid loosem ng any bolt after it has been tightened. 3. ANTENNA LEAKAGE TEST 3.o1 Remove the protecting cover from the feed horn, and bolt the test plate to the feed horn in accordance with Fig. 3, using a standard O-ring gasket. 3.0 Figure 4 shows the test setup for supplying and metering dry nitrogen to the antenna. Page

1SS 5, SECTON 40-41-01 -: y., -. FEED HORN ++ Fig. l KS-l 5676 Horn-Reflector Antenna Page 3

SECTON 40+1-01 LO 79 N w \\ ll ~ / / R.H.ANDL,tl REQ. ) L // ll [ / BOTTOM FLANGE ANGLE WASHER 7/161 N,lDX v:l:e:l, dl.w#&,sealerst.lp.s \ e / / SEALER STRP ASSEMBLY ~ WRE MESH RUBBER SEAL BOLT 3/8-4X 3/4 N. (3 REQ) SECTON A-A Fig. KS-1 5676 Antenna and List 3 Feed Horn Page 4

1SS 5, SECTON 40-41-01 11/3 N. DRLL ;TAT$NDA open the two outside valves. Pressure is applied to the hose connected to the right tube. An F pressure testing valve should be inserted into the other hose chuck to keep the chuck open to the atmosphere, and the hose should be coiled near the base of the instrument. Pressure is read directly on the new scale at the fluid level in the left tube; ignore the fluid level in the right tube. (b) f the B flow indicator is not available, construct locally a water manometer as shown in Fig. 5. 3.o3 Test the antenna for gas leakage as follows. 1:L.rL Fig. -Test Plate / f the method described in 3.04 is used, the flowrat.or (or gas meter) will not be required. The assembly and operation of the gas cylinder, both regulators, and hose are covered in Section 081-601-101 entitled Pressure-Testing Tools B Gas Regulator. Connect a pressure-testing hose between the outlet of the B gas regulator and the inlet of the flowrator (or gas meter) and a second pressure-testing hose between the outlet of the flowrator (or gas meter) and the gas admission valve of the test plate. Connect a gas pressure-measuring instrument to the other valve in the test plate. This instrument may be either a B flow indicator or a water manometer in accordance with Fig. 5. (a) Use a B flow indicator, when available, in a vertical position, following general instructions on leveling and maintenance in Section 081-603-100 entitled B Flow ndicator. Add fluid to the tubes, if required, until the level in both tubes falls between 80 and 90 on the regular manometer scale. Prepare a scale on 0 lines-per-inch graph paper in accordance with Fig. 5, and mount it on the instrument scale alongside the left-hand tube with the zero reading on the scale at fluid level, using a clear plastic adhesive tape. Before gas flow is started, close the center valve and (1) With the B flow indicator (or the water manometer) in the vertical position, attach the hose chuck to the pressure-measuring valve before charging is started. Feed the flowrator (or gas meter) from the nitrogen cylinder through the regulators. Adjust the regulator slowly to maximum output to avoid damaging the flowrator as the float rises to the top of the tube. This pressure is about 5 psi as measured on the outlet valve of the AT-734 regulator in accordance with Fig. 4. Watch the fluid level in the B flow indicator (or water manometer), and as it approaches 0. psi (5.5 inches of water), reduce the regulator feed pressure. Adjust the regulator further, as required, until 0. psi (5.5 inches of water) is maintained, and then record the gas usage shown by the flowrator. Caution: To avoid accidental damage to the antenna, do not exceed a pressure of 0.33psi (9.3inches of water) during leakage tests. Note: Large variations in pressure may occur when the sun emerges from or goes behind clouds. () f an equalized pressure of 0. psi (5.5 inches of water) can be obtained, the antenna leakage is determined by reading the gas meter over a measured period of time; or if a flowrator is used in place of the gas meter, the leakage is determined by direct reading of the flowrator. An approximation of the leakage at 0. psi (5.5 inches of water) can be obtained by gas meter or flowrator readings at lesser pressure, if it is impractical to bring the pressure up to 0. psi (5.5 inches of water), by using the following Page 5

SECTON 40-41-01 1$ TANK )% 1 w!- AT-a1 ---,,,.- A- ROCKWELL NO. 150 LST 3 FEEO HC EJ7R%<* \ \ AT-7676 /~ \ PRESSURE TESTNG HOSE ASSEMBLY BRASS HOSE CONNECTON NPPLE / \ \ TO ANTENNA TO PRESSURE MEASURNG _ DEVCE d \ 90 RNG GASKET F PRESSURE TESTNG VALVE. 1/4 TO l/b V TO /4 NPT BRASS NPT BRASS REOUCNG BUSHNG FROM REDuCNG BUSHNG QiiL 1/ TO l/4 NPT BRASS REOUCNG BUSHNG 1/4 TO 1/ NPT BRASS REDUCNG BUSHNG REGULATOR F ( BRASS HOSE CONNECTON NPPLE \ FSCHER ANO PORTER TRFLAT FLOWRATE METER (NOTE ) NOTES: 1. OETERMNE THE NUMBER OF REVOLUTONS OF THE UNT PONTER FOR 15 MNUTE PEROD. MULTPLY BY 4 TO COMPUTE GAS LEAKAGE N CUBC FEET PER HOUR.. GAS LEAKAGE CAN BE READ DRECTLY N CUBC FEET PER HOUR. Fig. 4-Gas Leakage Test Page 6

1/4 N. O.D. X 3/4 N. COPPER TUBNG NSERT - T 1-1/4 N. CORRESPONDNG SCALE ON B FLOW NDCATOR b 0 o -10-0 3/8 N. O.D. CLEAR PLASTC TUBNG\ -30-40 -50-1/4 N. O.D. COPPER TUBNG - so -lo 1-8 N, -80 9 FLUD LEVEL - ~ $-. - FLUD LEVEL NO PRESSURE 9 N -90 WRE LASHNG, - SCALE (NOTE 3) WATER MANOMETER VERTCAL B FLOW NDCATOR (ALCOHOL) VERTCAL.- t N. 1?. ~ 11 11 E 0 MPROVSED STRAP CLAMP (4 REQ) NOTES : PRESSURE SCALES FOR WATER AND ALCOHOL MANOMETER (NOTE ) 1. READ PRESSURE LEVEL CHANGES N ONE TUBE ONLY,. USE A WATER SOLUBLE DYE N WATER AS FLUD FOR MANOMETER. 3, ATTACH SCALE USNG CLEAR PLASTC ADHESVE TAPE, Fig. 5-Water or Alcohol Manometer relationship or by using the graph shown in (1) Feed nitrogento the antenna in the manner Fig. 6. described i~3.03 (), except thattheflowrator (or gas meter) will notbe required when this method is used. When the pressure in the CFH (at 0. psi) = antenna has stabilized at 0. psi (5.5 inches of water) as indicated by the B flow indicator, the 0. X CFH (at observed pressure, p) water manometer, or a U.S. gauge No. 6336 D L Antennas having a gas loss cubic feet per hour at 0. satisfactory for installation. hand gauge, stop feeding gas to the antenna by closing the nitrogen tank valve and removing the hose from the gas admission valve of the not greater than 10 test plate. Observe the decrease in antenna psi are considered pressure, as read on the pressure-measuring device, for a period of 4 minutes. A loss in pressure of 0.6 inch of water or less during this period is considered satisfactory and approximates 3.o4 To determine antenna leakage by the pressure a leakage rate of 10 cubic feet per hour from drop method, proceed as follows. the antenna. Page 7

SECTON 40-41-01 0 18 16 14.300 1 lol--l-+-l-+-l#h 9 6 4.75.50.5 =.00 g.175 u a.150 3 m m.15 w a n..100.075.050.05 t 1 A /1! v 1 1 0 /1 3456 789 PRESSURE (NCHES OF HtO) / A ACCEPTABLE LEAKAGE RATES AT PRESSURES OTHER THAN 0. ms (5.5 OF H*O) CONVERSON GRAPH- PRESSURE N PS TO NCHES OF HZO 3.o5 Remove the pressure-testing connections. Remove the test plate. Replace the original protecting cover on the end of the feed horn. 4. LEAKAGE TEST FOR NSTALLED ANTENNA 4.01 The approximate leakage rate of an antenna in an operating system may be determined by an air-flow measurement made at the waveguide pressure window. 4.0 Disconnect the tubing from the manifold tq the waveguide near the pressure window. With a second length of tubing, insert a flow-measuring device, such as a flowrator (Fischer and Porter A6405-A1644A to 18 CF/HR) or a Rockwell No. 150 LPG gas meter, in the line. f there is a water trap or a drain tube at the bottom of the network, this must be sealed during the measurement or excessive leakage will be recorded. The bleed point in the waveguide pressure window, used for pressure sensing, must also be sealed. f, after these precautions have been taken, excessive leakage (more than 15 CF/HR) is recorded, the antenna should be soap-tested to ensure that it is the source of the leakage and to determine the areas of leakage. Repairs, if necessary, can be made according to Section 40-41-501. The pressure drop method in accordance with 3.04 may be used as an alternate method. Acceptable leakage rates for the antenna are shown in Fig. 6. Fig. 3456789 PRESSURE (NCHES OF H0) 6-Acceptable Leakage Rates and Conversion Graphs Caution: Avoid making antenna leakage measurements during perioo% of chan~ ng ambient temperature, such as on partly C1Oudy days, as su olden changes from overcast to sunshine will @ ve false resuts. 5. NSTALLNG THE 14-EDGE BLNDERS AND SUPPORTS 5.01 The antenna is shipped lying on a side. n this position, one side is not accessible. To permit access for attaching the 14-edge blinders, the antenna must be raised approximately feet and supported on sawhorses. When supporting the antenna, the supports must be positioned to permit removal of the weather cover edge seal angles and access to the bolts and nuts that secure the front weather cover clamping angle to the antenna. Detailed instructions for raising the antenna are covered in Section 40-41-0. () Antennas leaking at a rate exceeding 10 cubic feet per hour at 0. psi should be examined with pressure-testing soap solution to determine the points of leakage. Retighten the bolts in these areas and retest. f the leakage is not reduced to a satisfactory rate, the case should be referred to supervision. Section 40-41-501 describes repair procedures. 5.0 After the antenna has been raised and supported, remove the nuts and washers from the bolts marked A and B shown in Fig. 7. Retain the hardware, for it will be reused. Do not remove the bolts from the antenna. Remove and discard the weather cover edge seal angle, and install the 14-edge blinder in its place. Figure 8 shows the proper placement and position of the Page 8 r

1SS 5, SECTON 40-41-01 bolts, nuts, and washers. Tighten the bolts and nuts to a torque of 60 foot-pounds. 5.03 Secure the blinder support to the blinder and also to the front weather cover clamping angle as shown in Fig. 8 and 9. Use the three 3/8- by l-inch bolts to secure the support to the blinder and the three 1/ by 1-1/ inch bolts to secure the support to the front weather cover clamping angle. Apply a coat of KS-19094 antiseize compound to the threads of all bolts and nuts before using. Tighten the bolts and nuts to a torque of 60 foot-pounds. 5.04 After both blinders and supports have been added to the antenna, perform the antenna leakage test in accordance with Part 3 of this section. WEATHER COVER CLAMP NGAN LE> WEATHER COVER BOLT 1/ -0 X N. LONG SEALER STRP ASSEMBLY 9/16 X 1-3/8 X 3/3 N RGHT SOE ANGLE WEATHER COVER EOGE SEAL LOCK NUT (FG. OR FG 31 (EX13TNG) ~~R#JEL~O SECTON A-A Fig. 7 KS-15676 Antenna With Weather Cover Edge Seal Angles Page 9

SECTON 40-41-01 Y u * SECTON USE DOUBLE WASHER AT BOTTOM ANO TOP SLOT A-A Fig. 8-Front View of KS-15676 Antenno With 14 Edge Blinders Page 10

1SS 5, SECTON 40-41-01 1/-0 X 1-3/4 N. BOLT (4 REQURED) BLNOER ASSEMBLY SUPPORT CLAMPNG ANGLE 1~ 0 x 1-1/ N. BoLT FOR LST 9 ANTENNAs OR 1/-0 X N. BOLT FOR LST 14 ANTENNAs Fig. 9 Side View of KS-15676 Antenna With 14 Edge Blinders Page 11 11 Pages