ASIC-Based Small Bore Submersible Level Transducer

Similar documents
Deep Submersible Level Transducer Series 300DS

Modbus Submersible Level Transducer

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

High-performance submersible pressure transmitter For level measurement Model LH-10

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

9700 Transmitter Submersible hydrostatic level transmitter

INSTALLATION & MAINTENANCE INSTRUCTIONS

ASDX Series Silicon Pressure Sensors

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

86BSD Backside Digital Output

SDX Submersible Depth Transmitter User Manual

SDX Submersible Depth Transmitter User Manual

780S Ultra High Purity Series

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

AUTO PUMP STATUS CENTER

High-performance submersible pressure transmitter For level measurement Model LH-10

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Expert Hydrostatic Level Transmitters

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

DPC-30 DPC-100. Reference Manual

T EK-SUB 4800C 19 mm Submersible Level Transmitter

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Design Features. General Description

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Submersible Pressure Transducer

Electro-Pneumatic Converter YT-940 SERIES

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Variable Area Flow Meters

AMS 2710 PCB pressure sensor module with V output

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

P499 Heavy Duty Pressure Transducer

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

P900. P900, Datenblatt Seite 1 DESCRIPTION

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

How to specify a product. Process Sensors and Mechanical Instruments

QBS Electronic Pressure Regulator

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

EPRB-2 Pressure Transducer

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Pro-V Multivariable Flowmeter

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Pressure Measurement Single-range transmitters for general applications

DTG - LCD Digital Temperature Gauge USER MANUAL

Programmable Submersible Level Transmitters

L3 Pressure and Level transmitter

PC12K Flush Diaphragm Pressure Sensor with Clamp

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

TRANSDUCER KIT 2 INSTALLATION INSTRUCTIONS

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

QBS Electronic Control Valve

DeltaSpan General Purpose Water Small Bore or Wastewater Pressure Level Transmitter LD34 and LD35 Series Manual

I/P Transducer Positioner Module

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

CDP-100S Pressure Type Level Transmitter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

User s Guide Temperature Sensor Converter TSC-599

EASIDEW TRANSMITTER with Current Source Output

GEMS SENSORS & CONTROLS

AMS 6916 Board mount pressure sensor with ratiometric analog output

RCD - Ultra-Rugged Differential Pressure Flowmeter

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

3.0 Pressure Transmitter Selection

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Features. Description

SITRANS P measuring instruments for pressure

Torque Tube TB300 Digital Transmitters

Pressure and Liquid Level Measurement 700 Series Users Manual

ellison sensors international

American Sensor Technologies. Your Sensor Business Partner...

Model PDT Dewpoint Transmitter

Programmable pressure and temperature transmitters PTM/RS485

OPTIBAR P 1010 C Technical Datasheet

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

Installation and Operation Manual

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

THE INSIDE STORY OF THE F-SERIES:

Mass Flow Controllers

Parametrable / Programmable Pressure Transmitter

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Ultra High Purity Model 780S

Programmable pressure and temperature transmitters PTM/RS485

Transcription:

ASIC-Based Small Bore Submersible Level Transducer KPSI Transducers Series 340 FEATURES Custom Level Ranges up to 230 ft (70 m) H 2 O Unparalleled Performance - Static Accuracy: ±0.05% FS - Total Error Band: ±0.25% FS Analog Outputs of 4-20 ma, 0-5 VDC or mv Welded 316 SS or Titanium Construction Small Diameter, Rugged, and Waterproof Custom Cable Lengths APPLICATIONS Ground Water Monitoring Down Hole Dewatering Surface Water Monitoring Shipboard Use Level Control The Series 340 is a small bore submersible hydrostatic level transducer that combines Pressure Systems excellent sensor competencies with the latest in Application Specific Integrated Circuit (ASIC) technology. Pressure Systems implementation of the ASIC provides unmatched sensor compensation over the entire operating range of the pressure sensor. The Total Error Band specification (±0.25% FS) over the complete operating temperature range (-20 to 60ºC) eliminates the user having to combine multiple performance specifications to understand the total accuracy of the transducer. All KPSI Transducers utilize a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium. The attached electrical cable is custom manufactured to Pressure Systems specifications and includes Kevlar members to prevent errors due to cable elongation, and a unique water block feature that self-seals in the event of accidental cuts to the cable. Each transducer is shipped with our latest SuperDry Vent Filter that prevents moisture from entering the vent tube for at least one year without maintenance, even in the most humid environments. The Series 340 is CE compliant to EN 61000-6-4:2001 and EN 61000-6-2:2001 and have a IP 68 and NEMA 6P housing protection rating. Pressure Systems, Inc. 34 Research Drive Hampton, VA 23666 USA Phone: 757-865-1243 Toll Free: 800-328-3665 Fax: 757-865-8744 E-mail: sales@pressuresystems.com www.pressuresystems.com Order on-line! www.levelandpressure.com ISO-9001:2000 Certified PSI Ltd. 124 Victoria Road Farnborough, Hants GU147PW United Kingdom Phone: +44 1252 510000 Fax: +44 1252 510099 E-mail: PSI@WestonAero.com Copyright Pressure Systems, Inc., 2006

Specifications Specifications subject to change without notice. Parameter 343 342 Units Comments LEVEL RANGES Full Scale Level Ranges 1 10 thru 230 (3 thru 70) 35 thru 230 N/A (10 thru 70) Proof Pressure 1.5 x FS ft H 2 0 (m H 2 0) vented gage reference ft H 2 0 (m H 2 0) sealed gage or absolute reference Burst Pressure 2.0 x FS STATIC PERFORMANCE Static Accuracy ±0.05 ±0.10 %FSO BFSL method Total Error Band 2 ±0.25 %FS TEB Resolution Infinitesimal %FS Total Error from BFSL ENVIRONMENTAL 316 SS or Titanium; Wetted Materials polyurethane or Viton Compensated -20 to 60 ºC Temp Range Operating Temp Range -20 to 60 ºC Protection Rating IP 68, NEMA 6P Viton is a registered trademark of DuPont. ELECTRICAL Excitation 9 30 VDC for ma and VDC output 20 for ma output Input Current ma max 3.5 for VDC output 4-20 ma Output 0-5 VDC Zero Offset ±0.12 < 0.1 Output Impedance See Loop Resistance diagram on page 5 510 ma VDC Insulation mega 100 Resistance ohm Circuit Polarity, surge/shorted output Protection ohm for ma output for VDC output for ma output for VDC output at 50 VDC NOTES: 1 Intermediate level ranges are available. 2 Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range per ISA S51.1. - 2 -

Specifications Specifications subject to change without notice. Parameter 343 342 Units Comments PHYSICAL Approximate Weight Cable Jacket Material 0.50 (224) 0.05 (79) Polyurethane (std) Tefzel (opt) lbs (g) lbs/ft (g/m) transducer cable Tefzel, Teflon and Kevlar are registered trademarks of DuPont. Pull Strength 200 (90) lbs (kg) Number of Conductors 4 Conductor Size Cable Seal 22 Molded Polyurethane Viton Gland AWG for polyurethane cable for Tefzel cable Uniquely-Designed Submersible Cable Our level transducers utilize one of two types of custom cable made specifically for submersible applications. The cable of choice for most applications is a polyurethane-jacketed cable incorporating Kevlar strength members to prevent errors due to cable elongation, and a water block liner to prevent water intrusion due to minor cuts to the cable jacket. Polyurethane cable is attached to the transducer using an injection molded polyurethane cable seal. The other alternative is a Tefzel -jacketed cable which provides superior chemical resistance and toughness, yet preserves the other features found in the polyurethane-jacketed cable. Tefzel is a Teflon derivative from DuPont and is the better choice for caustic media or when a high degree of abrasion is anticipated. While more expensive and less flexible, it can save money in the long term due to reduced maintenance costs. Tefzel cable is attached to the transducer using a compressed Viton gland cable seal. Both submersible cables have a pull strength of over 200 lbs. In all installations, care should be taken to ensure no damage occurs to the cable, as cable damage represents one of the most frequent causes of transducer failure. In the case where the user is not sure which material is best, contact Pressure Systems for assistance. Moisture Protection Our submersible transducers are equipped with custom, vented cable. The vent provides an atmospheric reference for the sensor, which is necessary for ensuring the highest possible accuracy when making a level measurement. It must be noted that if left unprotected, it provides a pathway for water vapor to enter the level transducer. This vapor will condense into water and could create an offset in the transducer output, or cause permanent damage. For these reasons, a Series 810 desiccant-filled vent filter is provided free of charge with each Series 340 we ship. Our latest SuperDry Vent Filter prevents moisture from entering the vent tube for at least one year without maintenance. Replacement filters are available from the factory. Series 810 SuperDry Long Life Vent Filter - 3 -

Accessories Installation Tips The Series 340 submersible transducers may be suspended directly in the media or in a perforated 1" PVC instrumentation still well. When suspending by the cable, users often utilize our cable hanger (PN# 12-90- 0931). This device slides onto the cable from the bare-wire end and is easily positioned anywhere on the cable by pushing the ends together. Once positioned, the cable hanger contracts to provide a snug grip. For applications requiring cable length in excess of 500 feet, consult the factory for proper installation and maintenance. Nose Cap The closed-face nose cap with a #8-32UNC-2B threaded hole can be used to attach weights. It was designed for installations where users may encounter sharp, protruding objects. Display Meter Pressure Systems offers two types of Display Meters to provide a visual readout of a single KPSI transducer having ma or VDC output. Both varieties utilize a red 0.54 LED display with 4 active characters to indicate a numeric range of -1999 to 9999. The units operate from 115 VAC power and provide a 24 VDC supply for power to the transducer. The Model 3019 Digital Readouts provide a sophisticated display of the transducer output with six 14-segment LED s for display of true alphanumeric characters; the last two used for process descriptors. These readouts offer programmable input configuration, isolated transducer power supply, selectable 2-point scaling or up to 17-point linearization, optional 4-20 ma retransmission, and two or four optional 10-amp SPDT alarm contacts for control. The 3019 has a NEMA 4X front panel with a polycarbonate bezel and a 1/8 DIN aluminum housing measuring 1.9375" H x 3.75 "W x 6.5" D. The Model 3620 Pump Controllers provide a more rugged package specifically designed to operate external pumps via two 10-amp SPDT alarm contacts. The 3620 provides front panel scaling, operates from - 20 to 70ºC, and uses 120 or 240 VAC. The NEMA 4X rated enclosure can be surface or panel mounted and measures 3.2" H x 5.5" W x 2.7" D. - 4 -

Technical Data Submersible Cable Exit Molded Cable Seal Submersible Cable Exit Gland Cable Seal ELECTRICAL TERMINATION 22AWG CONDUCTORS IN A SHIELDED CABLE WITH VENT TUBE 4-20 ma 0-5 VDC RED BLACK RED BLACK WHITE + EXCITATION - EXCITATION + EXCITATION - EXCITATION + SIGNAL ALL DRAIN WIRE SHIELD - 5 -

Order Information MODEL SUBMERSIBLE LEVEL TRANSDUCER 3 4 3 ±0.05% FS Static Accuracy, ±0.25% FS Total Error Band 3 4 2 ±0.10% FS Static Accuracy, ±0.25% FS Total Error Band MATERIAL S Stainless Steel T Titanium REFERENCE FORMAT 1 Vented gage 3 Sealed gage (except 343) 4 Absolute (except 343) OUTPUT 3 0-5 VDC 4 4-20 ma PRESSURE CONNECTION B Closed-face nosecap ELECTRICAL CONNECTION 0 Molded cable seal A Gland cable seal LEVEL RANGE (at MAX output) 1 x x x. x x x LEVEL RANGE (at MIN output) 1 3 4 B A Notes: x x x. x x x MOISTURE PROTECTION A None (sealed/absolute only) B Vent Filter CABLE TYPE 1 Polyurethane 2 Tefzel CABLE LENGTH x x x x (in feet) LABEL 2 1 The part number requires two level range limits, corresponding to the maximum and minimum analog outputs of the transducer, to be specified in pounds per square inch (psi) to three decimal places. The lower level range is typically 000.000 unless otherwise required. For reverse output requirements, enter the lower level range for the maximum output signal and the upper range for the minimum output. Use the following conversion factors: ft H 2 O / 2.3073 = psi Examples: 10 ft H 2 O / 2.3073 = 4.334 psi (enter 004.334 in the part number) m H 2 O / 0.703265 = psi 10m H 2 O / 0.703265 = 14.219 psi (enter 014.219 in the part number) For sealed gage reference add local atmosphere when converting to psi. Contact PSI for assistance. Example: 10 ft H 2 O / 2.3073 +14.7 = 19.034 psi (enter 019.034 in the part number) 2 Units of measure on standard PSI label. Contact PSI if private labeling is required. A B C psi ft H 2 O m H 2 O Warranty: The Series 340 product is warranted against defects in material and workmanship for 2 years from date of shipment. Products not subjected to misuse will be repaired or replaced. THE FOREGOING IS IN LIEU OF ANY OTHER EXPRESSED OR IMPLIED WARRANTIES. We reserve the right to make changes to any product herein and assume no liability arising out of applications or use of any product or circuit described. Products described in this Specification are not intended for life support applications. No. 1206-6 -