Bladder Accumulators High pressure

Similar documents
Diaphragm Accumulators

Bladder Accumulators Standard model

Bladder Accumulators Standard

Diaphragm Accumulators

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Diaphragm Accumulators

Hydraulic dampers 2. APPLICATION 2.1. PULSATION DAMPING TYPE SB...P / SBO...P. without damper

HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC

Diaphragm Accumulators

Change-Over Pressure Filter DFDK

Accumulators Bladder Accumulators. Hydraulics. Technical Information Series CE + ASME. excellent pressure solutions

Accumulators Bladder Accumulators. Hydraulics. Technical Information Series CE + ASME. excellent pressure solutions

Pressure-Relief Cartridge Valve, Size 4

Universal Charging and Testing Unit FPU-1

BLADDER ACCUMULATORS type AS and ASP 3.1 E 04-11

Safety and Shut-off Block SAF/DSV

Accumulator Technology. Product Catalogue.

Safety and Shut-off Block SAF/DSV

BLADDER ACCUMULATORS type AS and ASP 3.1 E 01-12

3-Way Safety Block DSV

BLADDER ACCUMULATORS LOW PRESSUR LIQUID SEPARATOR type ASBL

Flow control valves Series RFU - RFO 2/

3-Way Pressure-Reducing Cartridge, Size 2 4

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV

HYDRAULIC & LUBE OIL UNIT EQUIPMENTS

Safety and Shut-off Block SAF/DSV

Piloted Non-Return Valves

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Monoblock Directional Control Valve RMB 202

STAUFF Accumulators Accessories

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Bladder-Type Accumulators

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Leak-Free Load-Control Valve SAE ½ psi flange

Proportional Pressure-Relief Cartridge Valve, Size 2...4

// ADapters GUIDelines

Pressure Equalising Valves Model , for Differential Pressure Gauges

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

FLUID SIDE S SAFETY EQUIPMENTS 9 E 01-12

Booster Regulator/Air Tank

Push-in fittings CRQS, stainless steel

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Check valve hydraulically pilot operated

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Push-in fittings NPQH

Pilot Check Valve: Metal Body Type

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Proportional Throttle Cartridges, Size 16

Pressure reducing valve, pilot operated

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

shutoff valves 900 Series psig Manual Shutoff Valves

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Hydraulic Piston Accumulators

K0709 Quick-fit couplings

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Dri-Line Mk3 Monnier Compressed Air Drain Trap

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

HYDROPNEUMATIC BLADDER ACCUMULATORS

Electrically Operated Pressure-Relief Cartridge, Size 10

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

F l o w c o n T R o l v a l v E S

Pressure reducing valve, pilot operated, Model 3DR

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Push-in fittings NPQH

VERTICAL BLADDER TANK

Type 4708 Supply Pressure Regulator

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Type 4708 Supply Pressure Regulator

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Float valves Types SV 4, SV 5 and SV 6

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

NEW TYPE M PRESSURE RELIEF DEVICE

Diaphragm pressure switches, 42 V

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Technical Data Sheet TI-F50 Locking Units series KFH

HORIZONTAL BLADDER TANK

Pressure reducing valve, direct operated

Piston Accumulator Type : AP

Regulating valves REG-SA and REG-SB

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

DI-DRO ADVANCED FORMING SYSTEMS

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Inverse Proportional Pressure-Relief Cartridge, Size 10

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Transcription:

Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in hydraulic accumulators for storing fluids. HYDAC bladder accumulators are based on this principle. A bladder accumulator consists of a fluid section and a gas section with the bladder acting as the gas-proof separation element. The fluid around the bladder is connected to the hydraulic circuit so that the bladder accumulator draws in fluid when the pressure increases and the gas is compressed. When the pressure drops, the compressed gas expands and forces the stored fluid into the circuit. HYDAC bladder accumulators can be used in a wide variety of applications and are also available in different pressure ranges, see catalogue sections: zbladder Accumulators Standard No. 3.201 zbladder Accumulators Low pressure No. 3.202 zhydac Accumulator Technology No. 3.000 1.2. DESIGN The high pressure bladder accumulator consists of the pressure vessel, the flexible bladder with gas valve and the hydraulic connection with check valve. 1.2.1 Shell material The forged pressure vessel is seamless and manufactured from high tensile chrome molybdenum steel. 1.2.2 Bladder material The bladder material must be selected in accordance with the particular operating medium or operating temperature, see section 2.2. If discharge conditions are unfavourable (high p 2 /p 0 pressure ratio, rapid discharge speed), the gas may cool to below the permitted temperature. This can cause cold cracking. The gas temperature can be calculated using the HYDAC Accumulator Simulation Program ASP. 1.2.3 Corrosion protection For operation with chemically aggressive media, the accumulator shell can be chemically nickel-plated internally or supplied with a special plastic coating. For external corrosion protection the hydraulic accumulator can be supplied with an epoxy resin finish especially for offshore applications. 1.3. INSTALLATION POSITION AND TYPE OF INSTALLATION Information on secure installation positions and mounting elements can be found in the following catalogue sections: zbladder Accumulators Standard No. 3.201 zsupports for Hydraulic Accumulators No. 3.502 zaccuset SB No. 3.503 On no account must any welding, soldering or mechanical work be carried out on the accumulator shell. After the hydraulic line has been connected it must be completely vented. Work on systems with hydraulic accumulators (repairs, connecting pressure gauges etc.) must only be carried out once the fluid pressure has been released. The operating instruction must be observed! No. 3.201.BA When replacing seals and/or bladders, please read the Instructions for Assembly and Repair (No. 3.201.M). Notice: Application examples, accumulator dimensioning and extracts from approvals regulations relating to hydraulic accumulators can be found in the following catalogue section: zhydac Accumulator Technology No. 3.000 39

2. SPECIFICATIONS 2.1. MODEL CODE Not all combinations are possible. Order example. For further information, please contact HYDAC. SB690 32 A 1 / 312 U 690 D Series Nominal volume [l] Fluid port A = standard connection Gas-side connection 1 = standard design 1) 9 = special design (example.: 1/4" BSP) Material code 312 = standard design Fluid port* 3 = stainless steel 2) Accumulator shell 0 = plastic coated (internally) 1 = carbon steel 2 = chemically nickel-plated (internal coating) 6 = low temperature steel 8 = plastic coated (e.g. Duroplastic) internally and externally Accumulator bladder 2 = NBR 3) 3 = ECO 4 = IIR 5 = NBR 3) 6 = FKM 7 = other 9 = NBR 3) Certification code U = European Pressure Equipment Directive (PED) Permitted operating pressure [bar] Connection* A = thread to ISO 228 (1/2" BSP) D = thread to ANSI B1.20.3 (1/2" NPTF) Required gas pre-charge pressure must be stated separately! * others on request 1) gas valve in SB < 10 l = 7/8-14UNF, in SB 10 l = M50x1.5 2) dependent on type and pressure range 3) observe temperate ranges, see section 2.1. 40

2.2. EXPLANATIONS, NOTES 2.2.1 Operating pressure 690 bar (10000 psi) higher pressures on request 2.2.2 Permitted operating temperature of the hydraulic accumulator -10 C... +80 C standard design, others on request 2.2.3 Working temperature and operating medium The permitted working temperature of a bladder accumulator is dependent on the application limits of the metal materials and the bladder. Outside this temperature range, special materials must be used. The operating medium must also be taken into account. The following table displays a selection of elastomer materials including max. temperature range and a rough overview of resistant and non-resistant fluids. Please contact us for help in selecting a suitable elastomer. Materials NBR ECO Acrylonitrile butadiene rubber Ethylene oxide epichlorohydrin rubber Material code 1) Temperature range Overview of the fluids 2) Resistant to 2-15 C to 80 C zmineral oil (HL, HLP) zflame-retardant fluids from the 5-50 C to 50 C groups HFA, HFB, HFC zwater 9-30 C to 80 C zsea water 3-30 C to +120 C zmineral oil (HL, HLP) zflame-resistant fluids from the group HFB zwater zsea water IIR Butyl rubber 4-50 C to +100 C zoperating fluids from the group HFD-R zflame-resistant fluids from the group HFC zwater FKM Fluorine rubber 6-10 C to +150 C zmineral oil (HL, HLP) zoperating fluids from the group HFD zaromatic hydrocarbons zinorganic acids 1) see section 2.1. Model code, material code, accumulator bladder 2) others on request Not resistant to zaromatic hydrocarbons zchlorinated hydrocarbons (HFD-S) zamines and ketones zoperating fluids from the group HFD-R zaromatic hydrocarbons zchlorinated hydrocarbons (HFD-S) zamines and ketones zoperating fluids from the group HFD-R zflame-resistant fluids from the groups HFA and HFC zmineral oils and mineral greases zaliphatic, chlorinated and aromatic hydrocarbons zamines and ketones zammonia zskydrol and HyJet IV zsteam 2.2.4 Gas charge Hydraulic accumulators must only be charged with nitrogen. Never use other gases. Risk of explosion! In principle, only use nitrogen of at least Class 4.0 (filtration <3 μm). If other gases are to be used, please contact HYDAC for advice. 41

3. DIMENSIONS AND SPARE PARTS 3.1. DRAWINGS SB690-1... 5 Detail X (2:1) SB690-10... 50 Detail X (2:1) 42

3.2. DIMENSIONS standard model perm. operating pressure: 690 bar (PED) Nominal volume Effective gas volume Part no. A max. W [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [kg] 1 1 3444800 324 8.5 2.5 2.5 3129516 531 61 58 122 67 45 13.5 5 4.9 3129515 860 23 10 9 3436744 522 54 20 17 3436795 865 114 77 68 250 110 75 32 33.5 3436499 1385 186 50 49.7 4291199 1900 260 C Ø D max. 3.3. SPARE PARTS Please request spare parts for versions with spacer (item 17) in volume range 10... 50 litres separately. standard model perm. operating pressure: 690 bar (PED) Ø E SW Weight Description Item Bladder assembly 1) Bladder 2 Gas valve insert* 3 Retaining nut 4 Seal cap 5 Protective cap 6 O-ring 7 Seal kit O-ring 7 Washer 15 O-ring 16 Bleed screw 19 Backup ring 23 Repair kit 1) Bladder assembly (see above) Seal kit (see above) Oil valve assembly Valve 9-13 Anti-extrusion ring* 14 Washer 15 O-ring 16 Spacer 17 Lock nut 18 Bleed screw 19 Support ring 23 * available separately 1) when ordering, please state diameter of the smaller shell port Nominal volume Bladder assembly Seal kit Repair kit Oil valve assembly [l] Part no. Part no. Part no. Part no. 1 3010110 3182617 2.5 3211568 3182615 3201771 4291202 5 3211569 3201772 10 3120931 4347598 20 3211592 4347600 4192830 32 3211571 4347601 4030279 50 3116598 4347602 4. NOTE The information in this brochure relates to the operating conditions and fields of application described. For fields of application and operating conditions not described, please contact the relevant technical department. Subject to technical modifications. Accumulator shell (item 1) and company label (item 8) not available as a spare part HYDAC Technology GmbH Industriegebiet 66280 Sulzbach/Saar; Germany Tel.: +49 (0) 68 97 / 509-01 Fax: +49 (0) 68 97 / 509-464 Internet: www.hydac.com E-mail: speichertechnik@hydac.com 43

44