The System Curve, the Fan Curve, and the Operating Point

Similar documents
Applied Fluid Mechanics

Fan and air movement essentials

Quick Reference Technical Data

FAN ENGINEERING. Field Testing of Fans FE-900. Introduction. Testing Equipment. Testing Standards. Prior to Testing

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

The Discussion of this exercise covers the following points:

The routine maintenance and inspection of local exhaust ventilation (LEV)

HCD HIGH CAPACITY DRUM LOUVER

Centrifugal Pump Intro

Navy Guidance and Tips for Using DOEHRS-IH Ventilation NAVY & MARINE CORPS PUBLIC HEALTH CENTER

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

CHAPTER 6 INDUSTRIAL VENTILATION

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

Bioreactor System ERT 314. Sidang /2011

How Inlet Conditions Impact Centrifugal Air Compressors

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

Hydronic Systems Balance

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

ENGINEERING AUSTRALIA PTY. LTD.

AMCA Certified Ratings Program. An Introduction to the. An AMCA International White Paper. January 2018

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Third measurement MEASUREMENT OF PRESSURE

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

Pump-Fan-Compressor Sizing

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

(Refer Slide Time: 2:16)

CALMO

Stall & Parallel Operation. Witt&Sohn AG Oct-14

Layout Guidelines. Overview

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Design Tapered Electric Submersible Pumps For Gassy Wells Desheng Zhou, SPE, Rajesh Sachdeva, SPE, IHS INC.

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

LEV Issues. Local Exhaust Ventilation. A Salesman Approaches! Why is LEV important? What is it supposed to do? What comprises an LEV system?

Good News From the Doctor

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Laboratory Ventilation. Environmental, Health, and Safety

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

INTRODUCTION 1.0 GENERAL

Level MEASUREMENT 1/2016

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Conventional Ship Testing

Senior mechanical energy conversion trends

Computational fluid dynamics analysis of a mixed flow pump impeller

VISIMIX LAMINAR. BLENDING OF NON-NEWTONIAN LIQUID. POWER. CIRCULATION. MIXING TIME.

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Pressure Measurement

Assistant Lecturer Anees Kadhum AL Saadi

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site

83. If you pinch down the nozzle of a garden hose and the flow rate remains the same, the water flows (faster/ slower) to get through the nozzle.

UNUSUAL ASPECTS OF PUMP SYSTEMS. Jacques Chaurette p. eng. ww.lightmypump.com July 2003

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

Kansas State University Fume Hood Operation

TERRA NOVA - Wind energy - Standard Kit

Series 3000 Layout Guidelines

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

CADENZA

Domestic ventilation systems

EDUCTOR. principle of operation

A17W49_MASEM_F_EN MANUAL

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

AIRFOIL PROFILE OPTIMIZATION OF AN AIR SUCTION EQUIPMENT WITH AN AIR DUCT

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

A New Way to Handle Changing Fluid Viscosity and the Full-to-empty Effect

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Ventam 85 Installation & Commissioning Instructions

PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION

Proficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems

Introduction to Pumps

VISIMIX TURBULENT. LIQUID - SOLID MIXING. DEFINING JSS (JUST SUSPENSION SPEED)

4x6x10M. 6x8x12M GPM CUBIC METERS PER HOUR. 8x10x20S. 8x8x17. 6x8x17M. 8x10x17S. 10x12x14. 6x8x12XL. 8x10x12L. 4x6x12A. 6x8x12M. 6x8x12S.

OPERATOR, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL COMPRESSOR, RECIPROCATING, AIR; 15 CFM, 175 PSI;

Draft. Equipment/Instrument

Valves. Controllers. Valves Two Types

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Applications of Bernoulli s principle. Principle states that areas with faster moving fluids will experience less pressure

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

Compressors. Basic Classification and design overview

A17W23_MASE_MUS_EN MANUAL

Appendix ITALY Valsassina Tunnel near Lecco (Lombardy)

Hazardous Energy Program Lockout/Tagout

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

COATINGS SPRAY GUIDE Urethane 520

Understanding Lobe Blowers Roots Blowers. Article written by Technical Team of EVEREST GROUP

A18W35_MASE 130_F_EN MANUAL

MEASURING AIR FLOW. Ventilation (Outside Air) Calculations. Derive % of OA as part of total air flow using air temperatures:

Transcription:

The System Curve, the Fan Curve, and the Operating Point AIHA-RMS Sept. 12, 2018 Keith D. Robinson, P.E.

Overall Objective To equip an Industrial Hygienist with the skills necessary to document the performance of the Industrial Ventilation (IV) systems within their facilities without the need of outside personnel.

Learning Objectives Understand the concept of the duct system curve and the fan curve. Demonstrate the interaction between the system curve and the fan curve, the operating point. Apply the concept of the Operating point to develop simple IV system monitoring tools, procedures, and systems.

Example Industrial Ventilation System

Example Industrial Ventilation System

Example Industrial Ventilation System Common Questions: Is the system still operating as designed? What is the flow at each hood? What is the capture velocity at the hood face?

The System Curve

System Curve Assume you have a fan with a fixed duct system. An adjustable damper is installed in the ductwork upstream of the fan.

System Curve Fluid flow is either laminar or turbulent In laminarsystem the pressure drop is linearly related to velocity. In turbulentsystems the pressure drop is a function of the velocity squared. Most air systems are turbulent

System Curve

System Curve What happens if we adjust the position of the control dampers in the system?

System Curve

System Curve Summary Air system are typically turbulent. The pressure is related to the square of the velocity. A fixed duct system has one and only one system curve. Changing something in the ductwork creates a new duct system with a new system curve.

The Fan Curve

Fan Curve There are many types of fans. The types that are typically used in IV systems are: Centrifugal Backward inclined Radial blade Axial

Fan Curve As the fan impeller rotates, it imparts energy into an airstream. This energy can be seen in: Pressure Air movement (flow) Heat The relationship between the amount of flow and the amount of pressure created by a rotating fan is called the fan curve. The fan curve for each type of fan has a different shape.

Fan Curve

Fan Curve

Flow Fan Laws = Pressure = Horsepower =

Fan Law Example If you decrease the speed of a fan by 50%: The new flow rate is 50% of the original flow rate. The new pressure is 25% of the original pressure. The horsepower is 12.5% of the original horsepower. If you increase the speed of a fan by 10%: The new flow rate is 110% of the original flow rate. The new pressure is 121% of the original pressure. The horsepower is 133% of the original horsepower.

Fan Curve

Fan Curve Density Effects If the density of the air changes: The flow rate is not affected. The change in pressure is proportional to the change in density. The change in power is proportional to the change in density.

Fan Curve Density Effects Fan curves are developed for air at normal conditions (14.7 psi, 70 F) This means the fan curves are incorrect when used in locations whose elevation is above 1,000 ft. i.e. all locations in Colorado, Utah, and Wyoming. Make sure fan curves are corrected for elevation.

Fan Curve Summary Fan curves are typically generated per ANSI/AMCA-210 (ASHRAE 51). Each fan model has a specific fan curve. The fan curve is a function of fan speed and air density. Make sure your fan curves are corrected for elevation.

Review The system curve represents the performance of a duct system. It shows the relationship between the flow rate and the pressure required to create that flow through the duct system. The fan curve represents the performance of a fan. It shows the relationship between the flow rate and pressure created by the rotation of a fan impeller.

The Operating Point

Operating Point The system curve governs the operation of the duct system. The fan curve governs the operation of the fan. The interaction of these two curves determine the operating point for the system.

Operating Point

Operating Point

Operating Point Operating Point

Operating Point

Operating Point

Review The system will operate at the intersection of the system curve and the fan curve. A change in the system curve, i.e. a change in the pressure drop, will change the operating point. A change in fan speed will change the operating point.

So how is knowing this helpful in real life?

Application Remember these rules: In a fixed duct system the system curve is fixed. Once you have determined the system curve, the flow in the branch can be known with a single pressure measurement. Data from the original test & balance report provides system curve.

Application If the operating point (flow rate & pressure) changes then either the fan curve or the system curve has changed.

Application

Application Double Drum Hood (Fixed slots, no damper within the hood) = Fixed system curve The pressure at this location is a function of flow. MEASURE PRESSURE HERE.

Application What if an adjustable damper is in the duct?

Application What if an adjustable damper is in the duct? The pressure at this location is a function of flow AND damper position. DO NOT MEASURE PRESSURE HERE UNLESS DAMPER IS LOCKED. The pressure at this location is a function of flow. MEASURE PRESSURE HERE.

Application A simple pressure gauge can be mounted to the hood/duct or near the hood/duct to provide a permanent real time performance monitor. There are many inexpensive commercially available pressure gauges. Many include options for upper and lower indicator flags or colored overlays for the face to indicate acceptable operating range.

Application Approximate Installed Costs: Differential Pressure Gauge (basic): $100 Mounting & Tubing: $ 50 Installation (2 hrs. @ $75/hr.): $150 Approximate Total: $300

Application Write a Standard Operating Procedure or startup checklist that includes acceptable pressure range for each hood. If the hood pressure changes then either the fan curve or the system curve has changed. Maintenance or EH&S should be notified if pressure is outside of acceptable range.

Summary The system curve governs the operation of the duct system. The fan curve governs the operation of the fan. The interaction of these two curves determine the operating point for the system. Hood operation can be determined and documented with a single pressure measurement

Summary Simple pressure gauges can provide: Permanent real time performance monitoring Document system performance Facilitate system troubleshooting process