Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) SEAMLESS JUNCTIONAL CONNECTIONS
|
|
- Sara Doyle
- 6 years ago
- Views:
Transcription
1 11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector and beyond To order, call DePuy Spine Customer Service ( ). MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) CR XX /08 09/08
2 8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator
3 8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator
4 8:13 PM Page 2 With the MOUNTAINEER Spine System, you can design a fusion solution that solves the unique problems you face - from anomalies of patient anatomy to unexpected intraoperative developments without system constraints. The MOUNTAINEER Spine System has been designed to be both simple and versatile, because where you see challenges, we see solutions. Cha lle nge Rigid Fixation Limited space for cross connecting Rigid fixation to the occiput Minimal Access OC Driver Rod contouring and placement Limited accessibility to OC anatomy OC plate utilizes midline keel for maximum fixation. OC plate incorporates translating and rotating rod connections for easier alignment of the rod. Jointed rod allows for full range of angulation in a single plane and the advantage of revisiting head position intraoperatively. Prebent rod requires less contouring than a straight rod to accommodate the OC junction. Multiple drive options for OC bone screws (NEW minimal access driver). U N P A R A L L E L E D F I X AT I O N O P T I O N S Multiple hook sizes Cables and cable connectors attaches to the top of the minipolyaxial screw utilizing a doubletall set screw as a post, eliminating the need to connect to the rod. Hook will allow the placement of the head-to-head cross connector on the rod in a position where a screw or hook head is not present. Effective rod reduction Achieving appropriate screw trajectory while maintaining alignment with the rod Crossing the CT junction (lordosis to kyphosis) Medial/Lateral S olut ion Favored angle screw options (cephalad/caudad and medial/lateral) combined with the polyaxial drag feature simplify rod placement. Multiple rod-to-rod connection options Dual diameter rods 4.35 mm screw Lateral offset connectors Angled Lateral Offset Connector Two styles of reduction devices, including the new TOP NOTCH approximator. TOP NOTCH Approximator
5 11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector and beyond To order, call DePuy Spine Customer Service ( ). MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) CR XX /08 09/08
6 11:59 PM Page 1 I N D I C A T I O N S When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3), the SUMMIT Occipito-Cervical-Thoracic (OCT) Spinal System and the MOUNTAINEER OCT Spinal System is intended for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies) Spondylolisthesis Spinal stenosis Fracture/dislocation A LEGACY OF SOLUTIONS Atlanto/axial fracture with instability Occipitocervical dislocation DePuy Spine has been and continues to be a leader in Occipito-Cervico-Thoracic fusion technology to promote rigid fixation. DePuy Spine has collaborated with the surgeon community to drive procedural enhancements through implant and instrument UNPARALLELED FIXATION OPTIONS innovation. These collaborations have resulted in many firsts. DePuy Spine is committed to collaborating with surgeons to continue driving procedural Product 2000 SUMMIT Minipolyaxial s Tumors The Occipital Bone s are limited to occipital fixation only. The use of the Minipolyaxial s is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine. The SONGER Cable System, to be used with the SUMMIT OCT Spinal System and MOUNTAINEER OCT Spinal System, allows for wire/cable attachment to the posterior cervical spine. improvements for better patient outcomes. Year Revision of previous cervical spine surgery The SUMMIT OCT Spinal System and the MOUNTAINEER OCT Spinal System can also be linked to the ISOLA, TiMX, MONARCH, MOSS MIAMI and EXPEDIUM Systems using the Dual Wedding Band and Axial Connectors, and via Dual Diameter Rods. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. DePuy Spine offered the first minipolyaxial screw providing surgeons the ability to build a construct according to patient anatomy, not the constraints of the system. WARNING: In the USA, this product has labeling limitations. See package insert for complete information SUMMIT OCT Spinal Fixation System CAUTION: USA Law restricts these devices to sale by or on the order of a physician. DePuy Spine offered the first OC plate utilizing midline fixation. The OC plate also provides flexibility for rod placement through translating and rotating rod connection points SUMMIT SI Spinal Fixation System 2005 MOUNTAINEER OCT Spinal System DePuy Spine is a joint venture with Biedermann Motech GmbH. DEPUY SPINE, the DePuy Spine logo, MOUNTAINEER, EXPEDIUM, SYMPHONY, TOP NOTCH and SUMMIT are all trademarks of DePuy Spine, Inc. TiMX, MONARCH and MOSS MIAMI are registered trademarks of DePuy Spine, Inc. Other Cervical Products: Not all products are currently available in all markets DePuy Spine, Inc. All rights reserved. DePuy Spine accelerated ease of use in challenging occipito-cervical fusions with the introduction of the OC Adjustable Rod. DePuy Spine also provided innovative solutions to space constraints of the cervical spine through the development of the Head-to-Head Cross Connector and beyond To order, call DePuy Spine Customer Service ( ). MOUNTAINEER OCT Upgrades U N PA R A L L E L E D F I X AT I O N O P T I O N S More innovative solutions O P T I M A L C O N T RO L Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) CR XX /08 09/08
CONTROL WITHOUT COMPROMISE
CONTROL WITHOUT COMPROMISE GRYPHON ANCHOR WITH PROKNOT TECHNOLOGY PROKNOT Duncan Loop Duncan Loop Technology FiberWire MaxBraid TECHNIQUE GUIDE Make No Compromises When loaded onto a GRYPHON Anchor, PROKNOT
More informationFRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach.
FRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents
More informationHeadActive TECHNICAL DATA AND INSTRUCTIONS OF USE. Manufactured by: Onlywise Unipessoal Lda. Calle Santa Caterina nº 124 Porto (Portugal) PT
HeadActive TECHNICAL DATA AND INSTRUCTIONS OF USE Manufactured by: Onlywise Unipessoal Lda. Calle Santa Caterina nº 124 Porto (Portugal) PT510797725 HeadActive HeadActive is a product designed to improve
More informationUser Manual. Ambulatory Spinal-Air Decompression Collar
User Manual DDS MAX Ambulatory Spinal-Air Decompression Collar Table of Contents 3 What s Inside the Box 4 What it is & How it Works 5 Features of the DDS MAX 6 Contraindications & Precautions 7 How to
More informationDDS CERVICAL TRACTION COLLAR
DDS CERVICAL TRACTION COLLAR Thank you for choosing DDS and welcome to an enjoyable life free from neck pain. Table of Contents 4 What s inside the box 5 What it is & how it works 6 Features of the DDS
More informationBIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair. Shoulder Series Technique Guide by: Thomas Youm, MD
BIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair Shoulder Series Technique Guide by: Thomas Youm, MD As described by: Thomas Youm, MD Clinical Assistant Professor NYU Hospital
More informationi2i Head & Neck Positioning System
Positioning & Support USER MANUAL i2i Head & Neck Positioning System Stealth s User Manual and Maintenance Guide for the i2i Head & Neck Positioning System Customer Satisfaction 1.0 Stealth Products strives
More informationREVEAL IN DIE-CUT REMOVE FOR PRINTING
M A X I M U M A C C E S S S U R G I C A L P L A T F O R M REVEAL IN DIE-CUT REMOVE FOR PRINTING M A X I M U M A C C E S S S U R G I C A L P L A T F O R M Minimal access systems using tubular retractors
More informationMedical Education Calendar of Events ONE-TO-ONE CADAVERIC ONE-TO-ONE CADAVERIC CADAVERIC ONE-TO-ONE GROUP LEARNING GROUP LEARNING/
/ Medical Education 2015 Calendar of Events / ROUP / / / UP / OUP / / 2015 / Musculoskeletal Education and Research Center (MERC) MERC is the educational division of Globus Medical. Committed to the continuous
More informationAesculap ProSpace Titanium / PEEK
Aesculap ProSpace Titanium / PEEK Posterior Lumbar Interbody Fusion System Aesculap Spine ProSpace Implant Design Content A Philosophy 3 B Implant Material 4 C Implant Features 6 D Surgical Technique D1
More informationPneumatic Kerrison. Technology that makes life easier. Aesculap Neurosurgery
Pneumatic Kerrison Technology that makes life easier. Aesculap Neurosurgery Air: The Elementary Solution. A stroke of genius and the ability to translate it into technological innovation. KAIRison. A revolutionary
More informationModular OMF-System Cluster
1200 1700 Modular OMF-System Cluster 2000 MONDE face The modular OMF-System Cluster consisting of three systems, has been especially designed for the osteosynthesis in cranio maxillofacial surgery and
More informationCompact Triple Cabinet Outlet Station Model B Installation and Operating Instructions
PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model
More informationIMPLANTS & INSTRUMENTS FOR TISSUE REPAIR
IMPLANTS & INSTRUMENTS FOR TISSUE REPAIR Surgical Innovation Customer Driven For 10 years, Parcus Medical has been listening and reacting to the demands of the changing health care environment. Our mission
More informationPatient Positioning Made Easier
Ordering Information 3 Million Safe Clinical Uses Patient Positioning Made Easier Spinal Surgery Systems Mirrors ProneView Spinal Surgery Top Platform, Protective Helmet and Fastening Rod D28700CE ProneView
More informationThe Arizona Quarterly
Spring 2010 Golf Edition SpineScottsdale Physical Therapy Newsletter The Arizona Quarterly A Note from Shane My wife, Emily, and I have just completed our 1 st quarter with our new clinic: SpineScottsdale
More informationLITe Decompression System Surgical Technique. Non-reflective PVD coating Full microdiscectomy set Simple, low-profile light source
LITe Decompression System Non-reflective PVD coating Full microdiscectomy set Simple, low-profile light source Table of Contents System Overview.... 3 Access.... 4-6 Patient Positioning.... 4 Targeting...
More informationRotator Cuff Solution. Combined Strengths. Precise Control. TWINFIX Ultra FOOTPRINT Ultra Suture Anchors
Rotator Cuff Solution R Combined Strengths. Precise Control. TWINFIX Ultra FOOTPRINT Ultra Suture Anchors Trusted materials Absorbable Our absorbable HA suture anchor combines poly-l-lactic acid (PLLA)
More information1. Connect the attached anesthesia mask to your anesthesia system using the included tubing and connectors.
MouseandRat I nt ubat i onki t Included Equipment: Mouse or Rat Intubation Platform Mouse Intubation Stand with adjustable head positioning Anesthesia mask for anesthesia delivery during intubation Anesthesia
More informationUltra Lightweight Family
Ultra Lightweight Family Live without limits Living an active life means putting your heart and soul into it, being part of something, taking a deep breath of nature, freeing your mind, and going beyond
More informationGRYPHON BR Suture Anchor
GRYPHON BR Suture Anchor Key Features & Benefits GRYPHON T GRYPHON P GRYPHON BR is the newest and smallest shoulder instability anchor in the DePuy Mitek portfolio. This suture anchor, despite being small
More informationInjector system for implantation of 1stQ foldable intraocular lenses
Instruction For Use 1st Inject Instrument Injector system for implantation of 1stQ foldable intraocular lenses The IFU is available electronically on our website: www.1stq.eu Content: The package contains
More informationOperation Manual. Woodpecker
Operation Manual Woodpecker IMT Integral Medizintechnik AG Haldenstrasse 5 6006 Luzern Switzerland Tel: +41 41 210 54 34 Fax: +41 41 210 54 38 info@imt-medical.com www.imt-medical.com Table of Contents
More informationUSER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.
USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. RECEIVING / INSPECTION Remove the Precision Medical,
More informationInstruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.
Instruction Manual Model TC1-S TopSide Clamp top side clamp (406)755-4258 (406)257-2711 www.timberlinetool.com 90 Conestoga Ct. Kalispell, MT 59901 USA For your personal safety READ and UNDERSTAND instructions
More informationThe Peritrochanteric Space The Next Frontier in Hip Repair
The Peritrochanteric Space The Next Frontier in Hip Repair The Peritrochanteric Space Explore the next frontier with technology-leading solutions Advance your techniques in arthroscopic hip repair with
More informationSee JAY Product Comparison Guide notes to the right. Cushions HCPCS Code Page # Lateral Stability Forward Stability. Backs HCPCS Code Page #
PRODUCT CATALOG PRODUCT RATING See JAY Product Comparison Guide notes to the right. Cushions HCPCS Code Page # Lateral Stability Forward Stability Pressure Management JAY Basic E2601/E2602 5 1 2 3 4 5
More informationStandard Collection Setup Manual
Standard Collection Setup Manual 727-391-9009 www.tourlinks.net Please register this product online at www.tourlinks.net WARNING! READ AND UNDERSTAND OPERATOR'S MANUAL BEFORE USING THIS UNIT. FAILURE TO
More informationCompact Triple Cabinet Outlet Station Model Installation and Operating Instructions
Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to
More informationAdapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR
NEW! Follow along with your smartphone to make assembly even easier! Adapter Kit For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* Assembly Instructions FULL YEAR 5WAR RA NT Y Specifications
More informationUltra Lightweight Family
Ultra Lightweight Family Live without limits Living an active life means putting your heart and soul into it, being part of something, taking a deep breath of nature, freeing your mind, and going beyond
More informationSTYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS
STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation
More informationTECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device
TECHNICAL HANDBOOK nvent CADDY Speed Link Manual SLS Locking Device Contents 1. WIRE ROPE SUPPORT OVERVIEW 3 A. Using Wire Rope 3 B. The nvent CADDY Speed Link Manual 3 C. SLS Features 4 D. SLS Mechanism
More informationPaintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132
Paintball Marker User s Manual 530 South Springbrook Road Newberg, OR 97132 Component Concepts, Inc., 530 South Springbrook Road, Newberg, OR 97132 Phone: (503) 554-8095 Fax: (503) 554-9370 www.phantomonline.com
More informationUSER MANUAL. DM65 Manual Flush/Tilt Combo Mount
USER MANUAL DM65 Manual Flush/Tilt Combo Mount 1 D1_1.11.11.indd 1 ! CAUTION When using this mounting system, basic precautions should be followed, including: Follow the entire installation/user s manual
More informationDeskCycle USER S MANUAL. Ellipse QUESTIONS / PROBLEMS. Order# Support and Contact: See the support link at DeskCycle.com
DeskCycle Ellipse USER S MANUAL Visit us at www.deskcycle.com for: Usage Tips Calorie Calculator Accessories And More QUESTIONS / PROBLEMS Order# Support and Contact: See the support link at DeskCycle.com
More informationtad PRODUCTCATALOG DUAL-TOP TEMPORARY ANCHORAGE DEVICES (TADS) Dual-Top TAD System Kit Dual-Top Temporary Anchor Devices (TADs) Button Top TAD
DUAL-TOP TEMPORARY ANCHORAGE DEVICES (S) Dual-Top System Kit The Dual-Top system includes a well-organized storage block, which allows for repeated sterilization The Dual-Top system includes 14 of the
More informationAssessments SIMPLY GAIT. Posture and Gait. Observing Posture and Gait. Postural Assessment. Postural Assessment 6/28/2016
Assessments 2 SIMPLY GAIT Understanding movement Evaluations of factors that help therapist form professional judgments Include health, palpatory, range of motion, postural, and gait assessments Assessments
More informationOPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS
OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS (Patent Pending) WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT
More informationDevice-Related Pressure Ulcer/Injury Prevention Cervical Collar Recommendations and Guidance
original April, 2010 updated September, 2017 Device-Related Pressure Ulcer/Injury Prevention Cervical Collar Recommendations and Guidance These recommendations are intended to provide guidance to improve
More informationVariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator
VariSource High Dose Rate Afterloader Procedures For Performing Breast Brachytherapy with The SAVI TM Applicator Contents I. CT Evaluation (~1 week prior to insertion) II. SAVI Applicator Implantation
More informationInspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to:
A H E A D O F T H E C U R V E C R A F T E D F O R P R E C I S I O N Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: Respect the thoracic
More informationSee JAY Product Comparison Guide notes to the right. Cushions HCPCS Code Page # Lateral Stability Forward Stability. Backs HCPCS Code Page #
CUSHIONS & BACKS PRODUCT RATING See JAY Product Comparison Guide notes to the right. Cushions Page # Lateral Stability Forward Stability Pressure Management JAY Basic E2601/E2602 5 1 2 3 4 5 1 2 3 4 5
More informationStudy & Manipulative Training Guide
Study Manipulative Training Guide What is the XCOLLAR? The XCollar is a complete Cervical Spine Splinting System designed especially for EMS. It ensures the highest level of patient safety while significantly
More informationX-FACTOR THINKING CHANGING THE WAY YOU THINK ABOUT DR A SINGLE DETECTOR. A FAMILY OF SOLUTIONS. DRX Family of Products
DRX Family of Products A SINGLE DETECTOR. A FAMILY OF SOLUTIONS. The imaging solutions in the DRX Family are all designed around the remarkable X-Factor wireless detector platform. This allows the same
More informationRAI-M series RUDDER ANGLE INDICATOR SYSTEM
RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr GENERAL Seafirst Rudder
More informationINSTRUCTIONS 360 Y-DROP HAGIE STS 2015
INSTRUCTIONS 60 Y-DROP HAGIE STS 05 INSTRUCTIONS 60 Y-DROP HAGIE STS 05 INTRODUCTION Before beginning, it s important to know where each mounting bracket fits relative to the row spacing involved. The
More informationWarner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax
DH-40i, Rev. 04.03.02 Micro-Incubation Platform For RC-40 Chambers Model DH-40i 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax DH-40i, Rev. 04.03.02 Table of
More informationHI-PRESS HYDRAULICS Ltd
-, Low Profile renches hown: units with interchangeable cassettes Rigid teel Design The Professional Low Profile olution implicity Includes handle to improve tool handling and safety. No tools are needed
More informationSatisfaction. For you and your patients.
WOMEN S HEALTH SOLUTIONS Satisfaction. For you and your patients. Tissue Removal System & Aquilex Tissue of One solution for hysteroscopic tissue removal. Operative O.D. of 6 mm minimizes the risk of perforation
More information3 Post Pressure Fit System Owner s Manual
3 Post Pressure Fit System Owner s Manual Use and Care Trouble Shooting Warranty Information Table of Contents 3 Post Pressure Fit System Introduction... 3 Overview of the 3 Post Pressure Fit System...
More informationMyoSure Tissue Removal System. For you and your patients.
Tissue Removal System All-in-one Solution. For you and your patients. One solution for hysteroscopic tissue removal. Now there s a fast, convenient way to remove intrauterine pathology with two powerful
More informationCP-D/CP-M Circular Polarizer for Phoroptor. User s Guide
CP-D/CP-M Circular Polarizer for Phoroptor User s Guide 2016 AMETEK, Inc. Reichert, Reichert Technologies, Auto Phoroptor RS and Phoroptor are registered trademarks of Reichert, Inc. Ultramatic RX Master
More informationHemorrhoid Multiple Band Ligator Set Instructions for Use
Hemorrhoid Multiple Band Ligator Set Instructions for Use -Micro-Tech (Nanjing) Co., Ltd- 1 IMPORTANT INFORMATION Caution: Federal law restricts this device to sale by or on the order of a physician. Read
More informationModel 6202 Reduced Oxygen Breathing Device 2
Model 6202 Reduced Oxygen Breathing Device 2 Simulator Accessory Package Operator s Guide Revision 2 26 FEB 2013 Environics Inc. 69 Industrial Park Road East Tolland, CT 06084-2805 USA Phone (860) 872-1111
More informationBetter Body, Better Golf
www.getfittogolf.com This e-book explains the basics of golf biomechanics and how Get Fit to Golf s ChiroFit Program can determine and assist in eliminating the underlying physical faults affecting a golfer
More informationRescue Ladder Model: KT ft (5.48m)
Rescue Ladder Model: KT36164 18ft (5.48m) IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationNo guesswork. Controllable tension for labral repairs of the shoulder and hip. BIORAPTOR Knotless Suture Anchor
No guesswork Controllable tension for labral repairs of the shoulder and hip BIORAPTOR Knotless Suture Anchor The BIORAPTOR Knotless Suture Anchor allows surgeons to control anchor tension in labrum repairs
More informationInstallation Manual. Version 12-10
Installation Manual The products and parts shown herein are to be installed and used adjusted in accordance with these instructions. Any deviation by the buyer, installer, or user from these instructions
More informationRADON 237A: ASSEMBLY GUIDE. Revision Valid for MY2017 Radon
RADON 237A: ASSEMBLY GUIDE Revision 3.0-05-29-2017 - Valid for MY2017 Radon RADON 237A: Table of Contents 1. Tools Needed and First Aid Kit... 3 2. Sizing Chart... 4 3. Seat Post Collar Assembly... 5 4.
More informationHenry Pratt Diviner Position Indicator. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #:DIVPOSNOM Revision Date: 2/9/11
Henry Pratt Diviner Position Indicator Operation and Maintenance Manual Job Name: Contractor: Date: Document #:DIVPOSNOM Revision Date: 2/9/11 SAFETY MESSAGES All safety messages in the instructions are
More informationNitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions
FM-171 Rev. B 8/00 Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions MODEL 6300-1 PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA 19440-0907
More informationExradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers
EXRADIN Ion Chambers Exradin Ion Chambers Exradin (EXacting RADiation INstrumentation) Ion Chambers have been built for over 33 years, are recognized by top research institutes and standards laboratories,
More informationCONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL
SAVE THESE INSTRUCTIONS DEALER/INSTALLER: GIVE TO HOMEOWNER CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL Model CCX-IG Note: 40 lbs. of sand required! SAND
More informationINFUSION SYSTEM (110V) (220V) USER S MANUAL
INFUSION SYSTEM 20-6000-00 (110V) 20-6005-00 (220V) USER S MANUAL 8000 South Kolb Road Tucson, AZ 85756 Phone 800.528.1597 Fax 520.885.1189 www.wellsgrp.com email: sales@wellsgrp.com GENERAL DESCRIPTION
More informationHEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock
HEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock Introduction The HEALIX ADVANCE KNOTLESS Anchors are the latest addition to the already successful HEALIX ADVANCE family
More informationMSA Latchways Solutions for Industry
MSA Latchways Solutions for Industry Fall protection systems for industrial applications Overhead systems Horizontal systems LadderLatch VersiRail Self-Retracting Lifeline (SRL) MSA Latchways Solutions
More informationOmega 3 Fatty Acid (O3FA) Bioabsorbable Coated Mesh
Omega 3 Fatty Acid (O3FA) Bioabsorbable Coated Mesh SUPERIOR HEALING WITH OMEGA 3 TECHNOLOGY Atrium s C-QUR Family of soft tissue repair products combine the clinically proven ProLite polypropylene with
More information889P & 889P/B Backboard
Users Manual 889P & 889P/B Backboard January 2012 Document ID: 00123-AU-V01 Read and retain this Manual for future reference 00123 DISCLAIMER This manual contains general instructions for the use, operation
More informationCONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL
SAVE THESE INSTRUCTIONS DEALER/INSTALLER: GIVE TO HOMEOWNER CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL Model CCX-AG Note: 40 lbs. of sand required!
More informationMANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE
MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and
More informationAllPro Foot. Posterior Mount Product Manual
AllPro Foot Posterior Mount Product Manual Instructions The AllPro PM foot system has been designed and manufactured for specific patient weights. Failure to follow the weight guidelines and/or overload
More informationThe TURTLE Concept Contents:
The TURTLE Concept Contents: General Assumptions The Turtle In Brief Why Developing the Turtle Turtle Lay Outs A Field Presentation The Delta TURTLE Concept General assumptions It must be possible to develop
More informationADVANCED CORE DECOMPRESSION SYSTEM X-REAM
ADVANCED CORE DECOMPRESSION SYSTEM X-REAM Percutaneous Expandable Reamer PRO-DENSE Core Decompression Procedure Kit SURGICAL TECHNIQUE Advisory Board C. Lowry Barnes, MD Wael Barsoum, MD Robert Heck, MD
More informationTABLE OF CONTENTS/LIST OF EXHIBITS
TABLE OF CONTENTS/LIST OF EXHIBITS Executive Summary... 2 Exhibit 1: Sales Performance: Market Leaders... 3 Exhibit 2: Market Share: Largest Players and All Others... 4 Exhibit 3: Sales Performance: Next-tier
More informationLightweight II S.E. Improved Design & Acoustics. Stethoscope
mproved Design & coustics ightweight S.E. Stethoscope nnovative chestpiece design Reliable and clear acoustics ightweight, durable design unable diaphragm for monitoring low and high frequencies Single
More informationAugust 28-29, 2009 The Pinehurst Resort and Spa Village of Pinehurst, NC
NC Spine Society PO Box 27167 Raleigh, NC 27611 2009 Annual Meeting of the North Carolina Spine Society August 28-29, 2009 The Pinehurst Resort and Spa Village of Pinehurst, NC This continuing medical
More informationAndrewsREF.org 1020 Gulf Breeze Parkway, Gulf Breeze, FL (850)
The Andrews Research and Education Foundation are proud to present the results of testing on the FaceLoc quick release system that has been completed in conjunction with the sponsoring company. Introduction:
More informationLarySeal - Laryngeal Mask Airways
LarySeal - Laryngeal Mask Airways The LarySeal range of Laryngeal Mask Airways have the following common benefits, which are incorporated into the Clear, Blue, Multiple, MRI and Flexi. Reduced risk of
More informationPackaging Information Bulk Packs Non-Gas
SIZE TYPE PIPE OD 10 IPS 10.750 12 IPS 12.750 14 IPS 14.000 16 IPS 16.000 (Note 1) FORMANCE PIPE IPS PRODUCTS BULK PACKS NON-GAS DISTRIBUTION (All series except 6500,8100,8300) LAYER 40 /50 /53 JOINTS
More informationThe advantages of the Impact NecksGen unit
The advantages of the Impact NecksGen unit Comfort The body forming pads place very little pressure on your collar bone, making the unit extremely comfortable and unlikely to create injury to your collarbone
More informationThe A-dec Difference Legendary Reliability
PERFORMER The A-dec Difference Legendary Reliability A-dec has earned a reputation for creating equipment of legendary reliability and quality. It is a reputation earned through dedication to excellence,
More informationUSER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder
USER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder Table of Contents 1. 2. 3. 4. 5. Safety Notice... 3 Operator s Instructions... 4 Duct Rod Sizes... 5 Duct Rodder Assembly... 6 Duct
More informationCinchLock SS (Sports Sheath) Knotless Labrum Restoration SURGICAL TECHNIQUE
CinchLock SS (Sports Sheath) Knotless Labrum Restoration CinchLock SS Knotless Anatomic Labrum Restoration System is designed to facilitate precise anchor placement in challenging environments during hip
More informationSanti Ribot in TITAN DESERT 2012 REX 3.0
Santi Ribot in TITAN DESERT 2012 REX 3.0 REX 3.0 SHOE AIR SYSTEM SHOE NECK LAST AIR SOLE STREAM ANATOMIC GRIPS THE LUCK SHOE TOE HEEL CUP SHOE TONGUE CLOSURE BUCKLE ARCO LUCK INSOLE SYNTHETIC SERIE 37-48
More informationStability Trainer. New! Balance Products. Rocker and Wobble Boards. New!
New! Stability Trainer Balance Products Rocker and Wobble Boards New! www.thera-band.com Rocker and Wobble Boards The Hygenic Corporation 1245 Home Avenue, Akron, Ohio 44310 USA 330.633.8460 1.800.321.2135
More informationCT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C
CT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C TAVR: Overview of the Application Overview: CT Transcatheter Aortic Valve Replacement (TAVR) planning assists with the assessment of
More informationProper Operation of Heath Consultants Incorporated Plunger Bar
Proper Operation of Heath Consultants Incorporated Plunger Bar Heath Consultants Incorporated 9030 Monroe Road Houston, TX 77061 (800) HEATH-US www.heathus.com Notice The contents of this manual are proprietary
More informationUniversal Anchoring Adapter For Mercedes
Universal Anchoring Adapter For Mercedes Anchoring Pin & Tube Set (For Most Mercedes Models) Users Manual 006 Chief Automotive Technologies, Inc. Chief s Limited One-Year Warranty & Liability CHIEF'S
More informationGALISO SOAP OPTION FOR PCT-ADW-D
GALISO SOAP OPTION FOR PCT-ADW-D Installation and Operation Instructions MANUAL NUMBER 21-11-1008 Issued March 2016 Rev B 09/26/2018 Copyright 2016 - Galiso, Incorporated 22 Ponderosa Ct., Montrose, CO
More informationNew. View our Evolution Product Video at
English Cover 10:10 Page 1 New Revolutionary Body Shaped Design Advanced Patient Positioning Relieves Pressure, Friction & Moisture Cuts Risk of Decubitus Ulcers Burst & Tear Resistant Easily Cleaned Just
More informationTriple Tine Mechanical Grapple
Attachment Solutions Triple Tine Mechanical Grapple Operators Manual KENCO Mechanical Grapple Operation Manual 1 TABLE OF CONTENTS 170 State Route 271 Section I. General Information.... 3 Section II. Safety...
More informationQE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax
QE-1, Rev. 03.27.03 35 mm Quick Exchange Platform Model QE-1 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax QE-1, Rev. 03.27.03 Table of Contents DESCRIPTION...3
More informationTube Clamps Advanced Tube Clamps for the Most Demanding Applications
www..accuflowsystems.com----ph:--240.457.4413 Tube Clamps Advanced Tube Clamps for the Most Demanding Applications Standard Size Tube Clamps TC Pure-Fit TC Pure-Fit TC Tube Clamps represent a new generation
More informationQUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER
S & S AIR-PAK X3 PRO What facepieces are approved for use with the Air-Pak X3 Pro SCBA? Due to the high temperature and communications performance requirements in the NFPA 1981, 2013 edition standard,
More informationBruker Sample Transport
Bruker BioSpin Bruker Sample Transport BST Installation and Technical Manual Version 002 think forward NMR Spectroscopy Copyright by Bruker BioSpin NMR GmbH All rights reserved. No part of this publication
More informationOWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY
OWNER S MANUAL This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY Models covered; PA506 EL506 Ergonomic Tool Arms, LLC PO Box
More informationChallenge Friends, Get Ranked and Earn Points with the FUTCHI_App Players
The Ultimate Soccer Lawn Game Ultra Fun and Fast Way to Develop Ball Skills Challenge Friends, Get Ranked and Earn Points with the FUTCHI_App 1-12+ Players Age 10+ 1 FUTCHI_rebounder is the revolutionary
More informationThe Criticality of Cooling
Reliability Solutions White Paper January 2016 The Criticality of Cooling Utilities, power plants, and manufacturing facilities all make use of cooling towers for critical heat transfer needs. By cycling
More information