1 Capability Statement high voltage experts High voltage solutions for electricity infrastructure owners

2 2 Megavar Capability Statement...we are an Australian company, specialising in the construction and high voltage testing of power system equipment...

3 Introduction and Company Overview Welcome to Megavar your high voltage experts Known for our industry leadership and great people, Megavar is proud of its ability to deliver effective solutions to its customers. We strive to be the best in everything we do, which means always delivering what we promise safely, on time, on budget and to the highest standard. We are an Australian company, specialising in asset maintenance, construction and high voltage testing of power system equipment. Our services range from programs to manage your assets, design, electrical construction, protection testing, high voltage testing, commissioning and project management. Now with a team of more than fifty technicians and engineers, we are well equipped to deliver substation maintenance and projects anywhere in Australia. Our engineers and asset managers are industry professionals with experience in generation plants, transmission terminals and distribution substations in all states. What sets Megavar apart from the competition? Our people Our industry knowledge End-to-end solutions Client relationship management Strategic mix of technology and delivery What drives our success? Underpinning the success of our company are two fundamental business objectives: To build and satisfy a customer base through superior quality service with fair dealings based on trust and respect. To deliver the Megavar Make It Happen philosophy: leading to long term relationships with customers, suppliers and employees. These primary objectives have instilled a company team culture and loyalty amongst the company s long serving employees and established a loyal long term customer base built on repeat business. Who uses our services? The company operates from five offices providing Australia-wide coverage to deliver specialist high voltage construction and testing services to HV asset owners in a range of market sectors including: Utility companies Government corporations Heavy industrial and commercial sites Mining companies Turnkey project service providers Power system OEM s What keeps us in front? We think it s our customer focused leadership, the investment we make in training our people, our dedication to be the industry leaders and to be innovative. It could also be because we re responsive to our customer s need. When you put it all together it ensures Megavar will remain a leader in the high voltage industry for many years to come. We look forward to meeting your challenge! See us at Megavar Capability Statement 3

4 Core Competencies and Achievements Why choose Megavar? Quality we have the skills and commitment necessary to deliver high voltage solutions, effective and lasting support and security of equipment. Specialist knowledge our key technical people are passionate about high voltage solutions and work to understand our customers assets and needs to ensure we add real value over the life of your equipment. Talent we deliver strong solutions with safe work practices and clear documentation. Leadership we employ proven modern and traditional techniques, not fads. Full service our design, construct and test skills are in-house. We take personal responsibility for delivering a fully-integrated product from design to commissioning. Affordability we combine our commitment to quality and professionalism with the energy and innovation necessary to remain cost effective and affordable. What we can do for you Our high voltage experts provide a comprehensive suite of asset management, project management, construction, design, commissioning, high voltage testing and condition monitoring services for all industries and high voltage equipment. We provide our customers with an end-to-end engineering service that ensures reliability and longevity of your HV assets. We believe in working smarter for our customers and investing in equipment and training needed to deliver a more effective outcome. Valuable time and reputations are protected by allowing us to pass our industry knowledge to your project or assets. Megavar has in place all the necessary systems and processes to ensure compliance while working on your project. We re currently working towards ISO accreditation. We take the time to identify and tailor the management processes most appropriate for the project type and size. Delivering your project We can help to: Reduce your risk by ensuring we have the right people with the right equipment at your service when you need it. Improve your capability through access to people who develop a strong understanding of your assets and system components. Reduce your overall project costs by delivering our services efficiently and accurately. Achieve full turn key solutions, design, build, test and commission. Educate your internal staff in the correct operation and maintenance of your high voltage equipment. Maximise investment in your equipment by ensuring the optimal life is achieved. Maintain your productivity by helping you understand how your equipment is performing. 4 Megavar Capability Statement

5 We can provide: Engineering Services Compliance auditing Client s engineer Substation design Distribution design Earthing design SCADA design Drawing review Testing Motor and generator high voltage testing Transformer testing Line testing Online partial discharge testing SF6 leak detection IR imaging Thermographic imaging Earth testing Protection relay testing SCADA engineering Installation and Projects HV electrical construction HV civil construction HV switching operations Fault and maintenance service level agreements Project management Cable jointing Value engineering Asset Maintenance Services Megavar has developed relationships over many years with large scale asset owners by performing regular asset inspection, testing and maintenance services all designed to maximise the life cycle and risk profile of assets in service. By developing a comprehensive understanding of the assets and system in which they operate we have been able to provide preventative programs and solutions. Megavar have maintenance and upgrade programs in place with: Transend Networks, Aurora Energy, CitiPower / Powercor, SP Ausnet, Tamar Valley Power Station, SAPower Networks. We also provide maintenance programs for a large number of heavy industrial and private asset owners. Megavar Capability Statement 5

6 Getting to know us Megavar is a wholly Australian owned engineering firm, originating from Tasmania. We have grown rapidly since our inception in 2004 now employing more than 50 engineering staff. We have established offices in Hobart, Launceston, Melbourne, Brisbane and Perth to provide local support to our valued customers. The following people are key contacts within the Megavar business for technical and administration enquiries. We welcome all enquiries and recommend contacting the person closest to your location for prompt service. For larger projects we recommend that you contact Rod or Matt to discuss your requirements. Our key people Matt Geoghegan CEO Rod Wright Market Development Manager Tim Moore Service Delivery Manager Cameron Hanson Business Improvement Manager George Davies Service Team Leader Vic. Rachel Puzey Service Team Leader Northern Tas Damien Virieux Service Team Leader Southern Tas Chris Owens Distribution Design Manager 6 Megavar Capability Statement

7 Our best asset Megavar recognises that its main asset is its people. That s why we invest heavily in the development and retention of good people. Megavar was formally recognised as an Employer of Choice by being a winner in the 2012 awards program. Megavar is considered by the industry as an employer of choice. This is evident through our continued ability to attract and retain quality people in the business. Megavar supports and retains quality employees by providing in-house and external training and development programs so that employees are continually up-skilled in their respective fields of expertise. The development of employees has enabled the company to provide career planning, opportunities and promotion from within the organisation resulting in a skilled, high performing, cohesive and loyal team culture. We pride ourselves on flexibility and our whatever it takes attitude to getting the right result for any contract. Megavar is committed to the training of apprentices and sees the development of new employees part of our obligation to sustaining a healthy industry. Our people are our business....megavar recognises that its main asset is its people... Megavar Capability Statement 7

8 What we ve achieved Megavar has been involved in many interesting projects that demonstrate our extensive experience in high voltage infrastructure. Cheriton Ave Substation Commissioning and Testing, Sydney Megavar provided testing and commissioning services to the Endeavour Energy Cheriton substation in Sydney for CLM Infrastructure (Zinfra). This significant project involved having the Megavar crew certified onto the Endeavour Energy Network as well as performing the testing and commissioning activity for the site. The project was delivered without incident and to the clients satisfaction. Kingston Sub Station Megavar worked with Alstom on the Kingston Sub Station up-grade for Transend Networks. This project delivered a new 33kV control building housing Siemens Switchgear, the existing line protection panels were replaced, SCADA integration of all equipment along with two new 110/33kV ABB transformers, 2 new station services transformers, New A and B solid bus along with a new bus coupler. Five new circuit breakers and two sets of voltage transformers were installed. The entire project was undertaken under brown field conditions and short return to service timeframes were adhered to at all times. This was a construct and commission project for Megavar and the benefits of this were highlighted as all milestones were met and the synergies between our testers and fitters ensured that there were no delays during the commissioning process. Knights Rd Megavar worked with Powercor Network Services to re-build the Knights Rd substation as part of the Southern security upgrade for Transend. Multiple substations have been involved during the works. Knights Rd being a brown field site, has involved some complex staging & planning in order to keep supply up to customers due to the strict return to service requirements and short outage timeframes. The Megavar team has been successfully working in challenging conditions throughout the winter. Creek Rd Megavar was awarded the 110kV bypass cable installation at Creek Rd by Powercor. This involved the installation of temporary 800mm2 110kV cables run on cable ladder through the existing in service switchyard. The commissioning of this cable allows for the existing redundant control building to be demolished allowing for the construction of the new GIS building. Gordon Power Station Megavar are working with Hydro Tasmania to deliver part of their statewide circuit breaker replacement program. Gordon power station circuit breaker 8 Megavar Capability Statement

9 A52 was removed and replaced with a new 220kV ABB unit. Megavar also managed the civil component of this work providing Hydro Tasmania with one point of contact for the project delivery. George Town 110kV Substation / Aurora Energy Tamar Valley 110kV protection upgrade Megavar was employed by Jemena asset management to conduct design, test and commissioning services for two new 110kV transline protection panels. The panels included dual protection schemes integrating with both existing generator and site protection as well as the Transend Networksowned Georgetown substation via an optical path ground wire. The upgrade ran concurrently with primary and secondary testing and commissioning works which Megavar undertook for Transend at the remote end of the line. George Town Substation T2 and T3 200MVA Auto Transformer Testing and Commissioning Megavar was employed by Transend Networks services for testing and commissioning services relating to the installation of two 200MVA 220:110kV auto transformers at the Georgetown substation. Testing included site acceptance testing and integration of all newly installed primary and secondary equipment. Concurrently Megavar was employed directly by the supplier of the new auto transformers to conduct a full suite of site acceptance tests on their behalf relating to the transformers. Derby Substation Megavar was contracted to perform testing and commissioning works for the upgrade of the Derby substation, which included a new transmission line bay and an upgrade in capacity of the 110kV/22kV power transformer. We performed primary and secondary testing for all of the new equipment and protection systems, including integration into the existing substation infrastructure and the broader transmission networks. The project was established to provide a connection point for the new 200MW wind farm development in Tasmania s far North East, for which the testing scope was extended to include a new anti-islanding scheme and runback control mechanism, incorporating coordination of measurement and control across four different substations and the central network operations centre. Megavar worked alongside technicians and engineers from several companies to ensure that the complex nature of the scheme s design was implemented correctly and successfully. The wind farm commenced generating load into the transmission network in March Burnie Substation Megavar was engaged by Zinfra to perform isolation of existing equipment, Factory Acceptance Testing, Site Acceptance Testing and integration with existing equipment, and commissioning associated with the 110kV system upgrade at Transend Networks Burnie substation. During FAT Megavar engineers performed secondary injection testing of new protection panels proving correct application of relay settings and operating characteristics, operation of logic as well as proving internal panel wiring had been installed correctly and two discreet protection and tripping circuits existed. SAT consisted of verification of current transformers and voltage transformer against nameplate values, confirming new dead tank circuit breakers operated within manufacturer s specifications and performing high voltage withstand testing to prove the equipment was suitable to be energised from the system. Commissioning of the new apparatus included service voltage and stability checks to ensure all equipment was operating correctly. Newton Pumps Megavar worked again with Zinfra under a similar arrangement to the Burnie substation 110kV upgrade to perform FAT, SAT and commissioning of the redeveloped Transend Networks Newton substation. In addition to testing and commissioning the 110kV transmission line bay apparatus Megavar engineers also tested and commissioned a new 110kV Bus Section, a 110kV / 22kV and 110kV / 11kV power transformers. Commissioning of the new 110kV / 22kV power transformer and associated protection devices was performed under quite demanding circumstances with only a 6 hour window permitted to perform all required checks and testing as the only connection to the 22kV system was the adjacent mine site who could not be off line any longer than this time frame. Megavar engineers were able to perform all commissioning works in this time frame and restore supply to the mine without delay. BHP Billiton Macedon Megavar was subcontracted to perform configuration of protection relay settings, application of settings and secondary injection testing of 5 gas turbine protection relays, 2 diesel generator protection relays and two feeder protection relays at BHP Billiton Petroleum Macedon gas plant. The generator protection relays were Schweitzer Engineering Laboratories SEL 700G and the feeder protection relays were SEL 751A. Megavar was provided a window of only 4 days in which to perform all setting development, setting application and relay injection testing. Megavar was able Megavar Capability Statement 9

10 10 Megavar Capability Statement...Megavar has been involved in many interesting projects that demonstrate our extensive experience in high voltage infrastructure...

11 to perform all works required within the specified time frame including resolution of several setting issues between the supplied settings documents and the parameters available within the relays. Aurora Energy Tamar Valley Megavar was engaged by Aurora Energy Tamar Valley to perform routine testing of their Mitsubishi Electric 177MW combined cycle gas turbine, 89MW Mitsubishi Electric 68MW steam turbine and all associated protection relays. Testing of the generators included stator insulation resistance and polarisation index, stator winding resistance, stator dielectric loss angle and tip up, rotor insulation resistance, rotor winding resistance and rotor winding impedance. It was originally planned for Megavar to perform EL-CID testing of both generators however a change in the outage schedule restricted the rotors from being removed and so testing has been postponed until the next major outage. APM Maryvale Generator Testing Megavar engineers worked during a 12 hour outage to perform electrical testing of two generator units at the APM Maryvale site. Generator testing included stator insulation resistance and polarisation index, stator winding resistance, stator dielectric loss angle and tip up, stator partial discharge, rotor insulation resistance, rotor winding resistance, rotor Winding impedance and recurrent surge oscillography (RSO) of the rotor. Hydro Tasmania Tarraleah Unit 4 Testing Megavar was engaged by Hydro Tasmania to perform routine testing of Tarraleah power station generator number 4. Testing applied to the generator was stator insulation resistance, stator polarisation index, stator dielectric loss angle and tip up, rotor insulation resistance, rotor winding resistance, rotor winding impedance and rotor pole drop testing. Megavar engineers were able to identify a number of small issues with the generator stator and rotor, however given the age of the machine and operating environment the client decided these were not significant enough to warrant further works at the time and the generator was returned to service. Mornington Substation Megavar was sub contracted by Powercor Networks Services to construct the new substation for Transend Network Services. This site is supplied via two 110kV transmission line bays connected to an A and B bus which supply two transformer bays which supply a 33kV Siemens switchboard consisting of two incomer panels, one bus coupler panel, two metering panels and eight feeders. Primary work included marking out and installation of foundation bolts, erection of all steel structures, assembly of side by side and end to end disconnectors, installation of circuit breakers, VT s, CT s, wiring and termination of all field cabling, fabrication and installation of solid A and B bus, connection of all equipment and steel structures to the earth grid, installation of overhead conductors, lightning protection and installation of operational earthing stations. Secondary work included installation and assembly of 33kV Siemens switchgear comprising of inter-panel wiring, station service transformers, DC systems, protection panels, fibre optic cabling and termination, installation of building earthing system and connection of all equipment to this earthing system. Ringwood Terminal Station Megavar has been actively involved in managing SP Ausnet s Ringwood terminal station line protection upgrade, including GE Multilin L90 relays and the first ever field installation of SEL s new 411L relay. The project includes review and rectification of design drawings, full management of ITP s and commissioning plans as well as coordination with network management for the purpose of lodgement of applications, outages and cut-over of the existing protection to the new protection. Very much a brown-field installation, the works have all been done while the station is on-line and on-load with cut-overs scheduled to occur on weekends. Once complete the existing scheme along with the associated cables and equipment will be decommissioned. Aurora Zone Substations Partial Discharge Testing Megavar has been employed as the preferred provider for the distribution authority in Tasmania to conduct online partial discharge monitoring services. Where areas of elevated PD are noted further offline and monitoring techniques are utilized to pinpoint the cause of the discharge. BHP Billiton Temco plant has contracted Megavar to replace the 22 kv cables at the Bell Bay plant involving 1000 meter runs of cable installed on overhead gantry. JB Swift, Longford Meats Megavar changed over a transformer and relocated another as part of a high voltage upgrade at the JB Swift Longford meatworks for SJ Electrics. Palmerston Substation 110kV Asset Upgrade Megavar has been employed by Jemena Asset Management to conduct lead primary and secondary testing and commissioning services at Transend Networks owned Palmerston substation. Works include the replacement and subsequent commission services of multiple Megavar Capability Statement 11

12 110kV transmission line schemes. The project also incorporates upgrade works at the remote ends of some of the circuit completed in June Mowbray Substation Stage 2 Megavar was employed by Jemena to conduct primary and secondary testing and commissioning services for the 110kV substation upgrade at the Mowbray substation. The works included the installation of a new transmission line bay, transformer bay, 110kV buscoupler and four 22kV feeders. Secondary protection devices included Siemens and Schweitzer relays for the main transmission, distribution and transformer protection and GE multilin products. Que Substation Megavar was employed by Jemena to design, test and commission the upgrade of the 110 kv power transformer located at the Que River substation. Works included transformer testing, voltage ratio and vector group, FRA, IR & PI, Guard devices and TPI. Megavar managed the Installation of new 22kV and 110kV circuit breakers, disconnectors and earth switches, as well as functional and operational checks, ductoring and timing, upgraded protection involving transformer protection relay GE T60, upgrade of the SCADA system and extensive modifications to secondary circuits. Megavar conducted primary tests involving highpot of all HV s, VLF of 22kV cables and primary balance tests of the transformer. Newman Power Station Unit G404 Testing and Commissioning Megavar was engaged at short notice to perform testing and commissioning of a new 65MW Rolls Royce gas turbine generator and associated 11kV bus, 11kV:415V unit transformer, 11kV:66kV generator step up Transformer and associated protection relays. With only three weeks to completely test and commission a new 11kV generator, an 11kV bus, a unit transformer, a GSUT, and all associated protection, Megavar s make it happen philosophy saw a great outcome for this contract. Copper Mines Of Tasmania Megavar was engaged by Copper Mines Of Tasmania to perform testing and auditing of the high voltage substations earthing systems located on the surface of the mine site. The sites testing and auditing included the main 11kV incoming substation, the 11kV Ball Mill substation and the 11kV Prince Lyell substation. Given the age and the history of the site and very little data with regards to the earthing system Megavar first performed testing on site and gathered as much data as possible to aid with the modelling process. Following the testing Megavar modelled the entire mine site surface substation earthing system including the interconnections between substations and also those to Transend Networks Queenstown substation and the Lake Margaret power station. Using the MALT, MALZ, RESAP and FCDIST modules of the CDEGS software package Megavar was able to determine the apparent earthing system impedances, the fall of potential, earth grid voltage rise, step and touch potentials, soil resistivity and fault current distributions for each of the CMT substations. These modelled values were then compared to the measured values to assess the condition of the earthing systems. Railton/Emu Bay upgrade Alstom Megavar was engaged by Alstom Grid to perform testing and commissioning for the 110kV upgrade of the Burnie Emu Bay and the Emu Bay Ulverstone transmission lines. The Emu Bay substation 110kV installation was completely replaced with a new three breaker scheme with two incoming 110kV transmission lines and two 110:11kV transformers. Megavar technicians performed all primary testing of new equipment, all secondary testing of new protection relays and commissioning of the installation. Megavar also installed a new SCADA system at the Emu Bay substation including the development and implementation of a new local HMI. While this was only a small project relative to many others undertaken by Megavar it was a complex arrangement due to the ring feed arrangement of Transend Networks 110kV supply in the area. ETSA Utilities Megavar is providing specialist testing and commissioning resources to ETSA Utilities as they undertake a substantial upgrade of the South Australian electricity infrastructure. Adelaide City West Project A team of Megavar testers and commissioning engineers undertook finalisation work for Alstom Grid Australia on this substantial project. Transend Networks HV Asset Routine testing Megavar is contracted as the preferred supplier for Transend Networks HV asset routine maintenance. Sunbury Electrification Project This project operated as a joint venture between O Donnell Griffin and Laing O Rourke Electrification is providing new infrastructure and upgrades to the Victorian rail network. Megavar provided pre commissioning and testing services to this exciting public transport upgrade. 12 Megavar Capability Statement

13 Tungatinah Electrical Installation Megavar was happy to be awarded the electrical installation contract to carry out the primary and secondary construction works on behalf of the principal contractor Powercor Network Services. The project to redevelop the 22kv switchyard located at Tungatinah, a Transend Networks asset saw Megavar carrying out installation works associated with the new Siemens 22kV indoor switchgear that is housed in the new substation building. Megavar was also responsible for carrying out all other major electrical works with this project. This included earthing systems, AC and DC installation, protection panels as well as fibre optic installation. Megavar is proud of the fact that no workplace safety incidents have been recorded during the course of this project. Megavar Capability Statement 13

14 Featured Services Distribution Design / Project Management Megavar has recently added additional staff to increase our capability in the areas of overhead power system, substation and underground cable design. This will further our aim of being able to provide complete end to end services for our clients. As well as adding significant design skills to Megavar, our staff have experience in evaluating and implementing new technology, training design staff and auditing design projects. Design capability has boosted Megavar s offerings in the following areas: High voltage distribution substation design. High voltage / low voltage overhead powerline design. Underground power systems and cabling design. Fibre optic cable design (overhead and underground). Data logging (voltage, current, power, harmonics etc.) Streetlighting design. Project management / supervision. Drafting (Microstation Autocad). High voltage installation compliance auditing. Megavar have invested in the latest software and equipment to facilitate our work and to allow us to produce the most accurate and cost effective designs possible for example: We utilise Poles n wires (industry standard powerline design software). LV Design (voltage drop current load analysis). Microstation (CAD) for all design and as built drawings. In house developed software for various design functions. Trimble GPS units (pole / cable location services). EDM Truepulse electronic distance measurers. In addition Megavar are able to mobilise at short notice and to rapidly expand our capability by realocating skills as required to meet clients demands. Many of our employees are multi skilled and can undertake a number of roles as and when required. 14 Megavar Capability Statement

15 Overhead powerline / Fibre Optic design: Megavar have significant capabilities and skills in this area in particular we are fully resourced to undertake audits of existing powerlines, design new powerlines and to produce all relevant design documentation in whatever format is required by our clients. This could include: Autocad plans of existing powerlines (heights, sags, locations etc) as well as the new power or fibre optic cables to be installed. Excel format spreadsheets or work plans of all required make ready works involved to upgrade existing infrastructure. Detailed work plans for new installations including construction types, attachment heights, stringing tensions etc. Poles n wires printouts / schedules of existing infrastructure and new cables. Equipment schedules. Substation Design / Construction: Megavar are experts in all areas of distribution substations. We have the capability to design, construct, test and maintain substations, earth systems and underground HV cabling and associated high voltage equipment. In addition to the design and construction of high voltage installations we also provide engineering certification and sign off of certificates of electrical compliance for all projects in accordance with the National Electricity Rules and Tasmania s Occupational Licensing Act We also are able to assist with production of all regulatory documentation which is required of owners of private high voltage infrastructure including OH&S documentation, testing & maintenance plans, operational plans as well as switching / isolation documents and procedures. Service options: At Megavar we pride ourselves on being able to adapt and personalise what we do to meet clients specific requirements. We are more than happy to jointly work through issues with our clients and produce an outcome suited to any specific requirements they may have. Megavar s flexibility and ability to adapt quickly to challenging situations is our greatest strength. We can resource quickly to meet clients requirements and can offer skilled labour and facilities in a number of formats as and when required. Megavar can provide full end to end services if required but are also able to provide skilled staff on an hourly hire rate or a fee for service arrangement to suit clients specific needs. Megavar Capability Statement 15

16 Megavar Additional Capability Services Value Engineering Megavar strives to understand the client s needs on a whole of the asset view and work to add services and skills that complement the efficiency of any maintenance program. Time: Have you calculated the actual cost of multiple suppliers of routine maintenance? Risk: Is the asset exposed to risk when multiple contractors are working on the site? Megavar actively looks to add value to our existing clients via adding complimentary services to existing contracts delivering cost savings and a reduced risk profile. The deeper our involvement the greater the ability to influence efficiency outcomes through our proven ability to reduce maintenance costs and reduce delivery time through value engineering and complementary activity analysis. Maximum results are achieved through detailed involvement addressing issues such as: Total asset maintenance understanding. Materials selection. Standardisation in selection and sizing of equipment. Programming and scheduling refinements. Skill provision partnerships. By bundling professional services into a single outsourcing arrangement (a Service Package ), clients are solving the problem of managing multiple providers, reducing risk and accessing more significant and immediate cost savings with greater long-term benefits. From Here: Megavar would appreciate the opportunity to offer our assessment of where we could utilise our expertise and experience in the High Voltage field to build efficiency and innovation into your program. 16 Megavar Capability Statement

17 Management systems and policies Occupational Health and Safety Management Megavar is fully committed and uncompromising in our quest to: ensure a safe work place for employees continually strive to improve safety performance instil a cultural mind set in the company to achieve an accident and incident free work environment Safety Megavar has a zero lost time target and we have met the target for the past five years. This outstanding result is achieved by identifying and rectifying any unsafe work conditions or practices, as well as promoting safe working practices. Our team recognise that in order to achieve an outstanding safety performance and best practice, we must have a proven systematic safety system, a committed management team and a pro-active workforce supported by an internal safety committee. Megavar upholds it own stringent standards and as a contractor to ensure we fully understand and comply with the requirements of the business we work in. This can only be achieved by full compliance with Workplace Health and Safety legislation. All employees and sub-contractors are fully engaged in the system and are made aware of their responsibilities through company and project inductions, toolbox meetings, Safe Work Methods (SWM s) and / or Job Safety and Environment Assessments (JSEA). Safety audits are conducted at site level. Megavar is presently working to gain certification to Australian Standard AS/NZS 4801:2001. Our quality assurance Megavar applies sound quality assurance principals to all our projects. We re working towards registration as an ISO9001 quality certified company with SAI Global. Independent third party audits are conducted across our system and structured internal quality audits are performed to ensure ongoing compliance and continuous improvement to our systems and procedures. Environmental management Megavar understands the potential damage when working on company facilities and project locations and the detrimental impacts affecting the local environment and communities. Our project planning specifically identifies potential impacts, risks and compliance requirements as they relate to the project and ensures appropriate actions are implemented to achieve zero incidences and to ensure full compliance. Megavar is presently working to gain certification ISO Megavar Capability Statement 17

18 Our clients Megavar is proud of the many leading organisations and businesses we have worked with on a variety of interesting and challenging assignments. 18 Megavar Capability Statement

19

20 How To Find Us All the information you will need including map locations are at Contact us General enquiries: Phone: Service enquiries: All Technical enquiries and questions relating to prospective projects, jobs and resources. Accounts enquiries: Please direct all accounts payable and accounts receivable queries to this . Our locations Launceston 89 Talbot Road Launceston Tasmania 7249 Hobart Hobart Technopark Unit 8/Tech Innovation Drive Dowsing Point Tasmania 7010 Melbourne 12/41 Sabre Drive Port Melbourne Victoria 3207 Brisbane Level 36 Riperian Plaza 71 Eagle Street Brisbane Queensland 4000 Maryborough 58 Churchill Street Maryborough Queensland 4650 Perth Unit Great Eastern Highway Ascot Western Australia 6104

List all key terms and acronyms used in the procedure, and their definitions.

List all key terms and acronyms used in the procedure, and their definitions. Purpose The purpose of this procedure is to provide guidelines for electrical safety in general within Seqwater in compliance with the Electrical Safety Act 2002, Industry Codes of Practice, Regulations,

More information

TENNIS VICTORIA STRATEGIC PLAN TO 2020

TENNIS VICTORIA STRATEGIC PLAN TO 2020 TENNIS VICTORIA STRATEGIC PLAN TO 2020 MESSAGE FROM OUR PRESIDENT AND CEO We are pleased and privileged to present Tennis Victoria s Strategic Plan to 2020. We acknowledge and thank all of the organisation

More information

Racecourse Operations Manager. Position Description

Racecourse Operations Manager. Position Description Racecourse Operations Manager Position Description Position Discription Racecourse Operations Manager Position Title: Reports To: Business Unit: Department: Racecourse Operations Manager CEO Pakenham Racing

More information

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures SAFETY QUALITY TECHNOLOGY Guidance on Safe Isolation Procedures Introduction Every year, people working on construction sites suffer electric shock and burn injuries some of which, tragically, are fatal.

More information

Low Voltage Electricity System Safety Rules & Associated Safety Guidance

Low Voltage Electricity System Safety Rules & Associated Safety Guidance Annex J To Loughborough University Facilities Management (FM) Health and Safety Policy Low Voltage Electricity System Safety Rules & Associated Safety Guidance 1. Introduction a. These Safety Rules are

More information

Planning for tennis in your Local Government Area. A resource from Tennis Australia

Planning for tennis in your Local Government Area. A resource from Tennis Australia Planning for tennis in your Local Government Area A resource from Tennis Australia Part 1 July 2016 ABOUT THIS RESOURCE This resource forms part of Tennis Australia's Local Government Engagement Program.

More information

Chief Operating Officer Approved by. Responsible Officer. Vice-Chancellor Approved and commenced 25 September, 2017 Review by September, 2020

Chief Operating Officer Approved by. Responsible Officer. Vice-Chancellor Approved and commenced 25 September, 2017 Review by September, 2020 Work Health and Safety Policy Responsible Officer Chief Operating Officer Approved by Vice-Chancellor Approved and commenced 25 September, 2017 Review by September, 2020 Relevant Legislation, University

More information

ANNUAL RELIABILITY AND POWER QUALITY REPORT for the year ended 30 June 2017

ANNUAL RELIABILITY AND POWER QUALITY REPORT for the year ended 30 June 2017 ELECTRICITY INDUSTRY (NETWORK QUALITY AND RELIABILITY OF SUPPLY) CODE 2005 ANNUAL RELIABILITY AND POWER QUALITY REPORT for the year ended 30 June 2017 SEPTEMBER 2017 Page 1 of 81 Contents 1 Purpose...

More information

gaf traffic 2015 capability statement

gaf traffic 2015 capability statement gaf traffic 2015 capability statement www.gaftraffic.com.au INTRODUCING GAF TRAFFIC GAF Traffic is a people-centred traffic engineering consultancy serving new and existing projects in Western Australia.

More information

Principles guiding Sport NI investment in Sporting Clubs and Sporting Winners objectives.

Principles guiding Sport NI investment in Sporting Clubs and Sporting Winners objectives. Enjoy Engage Excel Principles guiding Sport NI investment in Sporting Clubs and Sporting Winners objectives. Page 1 of 8 1. Background 1.1. This paper outlines a number of proposals that aim to contribute

More information

Strategic Plan. Approved: September 2016

Strategic Plan. Approved: September 2016 Strategic Plan 2016 2020 Approved: September 2016 VISION To be the leading university hockey club in Australia for high performance and development, and recognised as one of the most participation-friendly,

More information

London Organising Committee of the Olympic Games and Paralympic Games. 14 June 2010

London Organising Committee of the Olympic Games and Paralympic Games. 14 June 2010 London Organising Committee of the Olympic Games and Paralympic Games 14 June 2010 London 2012 Olympic and Paralympic Games Volunteer Protocol Title This document shall be known as the London 2012 Olympic

More information

Why walk? Introducing Heart Foundation Walking! What is Heart Foundation Walking? Your role. Host Organisation

Why walk? Introducing Heart Foundation Walking! What is Heart Foundation Walking? Your role. Host Organisation An Introduction Why walk? It s an inexpensive form of physical activity It s easy doesn t require special skills or equipment It has psychological and community benefits improves mental health and social

More information

HEIGHT SAFETY IT S EVERYONE S BUSINESS

HEIGHT SAFETY IT S EVERYONE S BUSINESS HEIGHT SAFETY IT S EVERYONE S BUSINESS WWW.SAYFA.COM.AU INTRODUCTION Providing a healthy and safe workplace is both a moral and a legal obligation. Safety is paramount when you have employees or contractors

More information

Health & Safety Policy & Plan. Rightway Roofing.

Health & Safety Policy & Plan. Rightway Roofing. Health & Safety Policy & Plan. Rightway Roofing. Valid: 02/2012-02/2013 Contents ( 1 ) Policy Statement. ( 2 ) Hazard Identification. ( 3 ) Hazard Management. ( 4 ) Induction & Training. ( 5 ) Monitoring

More information

Australian Volleyball Federation

Australian Volleyball Federation Australian Volleyball Federation Strategic Plan (2002-2005) (Updated July 2003) GOAL - to foster the sport of volleyball as a human endeavour 1 of 13 Contents: Introduction 3 Purpose & Vision 4 Whole of

More information

QIC. their ICT systems business Optus Business helps to deliver greater customer value

QIC. their ICT systems business Optus Business helps to deliver greater customer value CASE STUDY QIC CASE STUDY SNAPSHOT CUSTOMER QIC Limited INDUSTRY Finance Requirements Good, solid telecommunications services combined with a proven commitment to customer service. Solution IP network

More information

MINE SAFETY TARGETED ASSESSMENT PROGRAM. Ground or strata failure NSW metalliferous mines. April

MINE SAFETY TARGETED ASSESSMENT PROGRAM. Ground or strata failure NSW metalliferous mines. April MINE SAFETY TARGETED ASSESSMENT PROGRAM Ground or strata failure NSW metalliferous mines April 2017 www.resourcesandenergy.nsw.gov.au Document control Publication title: Ground or strata failure NSW metalliferous

More information

Power Unit 075. Maintain Substation Circuit Breakers

Power Unit 075. Maintain Substation Circuit Breakers Power Unit 075 Maintain Substation Circuit Breakers The specification details the required skills, knowledge and behaviours to establish competence to carry out the maintenance of high voltage power circuit

More information

Strategic Plan Basketball in Victoria:

Strategic Plan Basketball in Victoria: EP64949 placed pages.indd 21/11/12 2:14 PM - 1 - Strategic Plan 2013-2016 Basketball in Victoria: The world s best sporting community EP64949 placed pages.indd 21/11/12 2:14 PM - 2-2 EP64949 placed pages.indd

More information

Field Instruction. This instruction outlines the minimum requirements for all Horizon Power workers who undertake Vegetation Management Work.

Field Instruction. This instruction outlines the minimum requirements for all Horizon Power workers who undertake Vegetation Management Work. 10.6 Management Work Purpose This instruction outlines the minimum requirements for all Horizon Power workers who undertake Management Work. Scope The scope of this instruction is to inform all Horizon

More information

Progress with the Road Investment Strategy

Progress with the Road Investment Strategy Report by the Comptroller and Auditor General Department for Transport and Highways England Progress with the Road Investment Strategy HC 1056 SESSION 2016-17 22 MARCH 2017 4 Key facts Progress with the

More information

PSSI 3 High Voltage Metal-Enclosed Switchgear

PSSI 3 High Voltage Metal-Enclosed Switchgear 1. SCOPE This Safety Instruction applies the principles established by the ScottishPower Safety Rules (Electrical and Mechanical) and Company Safety Instructions to achieve Safety from the System for personnel

More information

NETBALL TASMANIA STRATEGIC PLAN

NETBALL TASMANIA STRATEGIC PLAN NETBALL TASMANIA STRATEGIC PLAN 2016-2020 Our Values Inclusion We are committed to the principles of respect and equality Integrity We are committed to practices that are safe, fair, transparent and open

More information

CRICKET VICTORIA-CRICKET AUSTRALIA SUBMISSION TO INFRASTRUCTURE VICTORIA LAYING THE FOUNDATIONS DRAFT PLAN 10 MARCH 2016

CRICKET VICTORIA-CRICKET AUSTRALIA SUBMISSION TO INFRASTRUCTURE VICTORIA LAYING THE FOUNDATIONS DRAFT PLAN 10 MARCH 2016 CRICKET VICTORIA-CRICKET AUSTRALIA SUBMISSION TO INFRASTRUCTURE VICTORIA LAYING THE FOUNDATIONS DRAFT PLAN 1. INTRODUCTION 10 MARCH 2016 Thank you for the opportunity to provide a submission in response

More information

To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy

To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy Annex I To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance 1. Introduction a. These Safety

More information

PSSI 1 High Voltage Switching

PSSI 1 High Voltage Switching 1. SCOPE This Safety Instruction sets down the procedures to be adopted when carrying out High Voltage (HV) Switching operations on The Company s System and other System(s) operated by the Company other

More information

RACING VICTORIA S EQUINE WELFARE STRATEGY

RACING VICTORIA S EQUINE WELFARE STRATEGY RACING VICTORIA S EQUINE WELFARE STRATEGY Published October 2016 Racing Victoria s vision is to be a leader in equine welfare and build a racing culture in which the safety and welfare of the racehorse

More information

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic

More information

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine. Health and Safety Procedure - Confined Spaces Section 1 - Background and Purpose (1) Confined spaces are, for the purposes of this procedure, defined as the following which is the definition under the

More information

A Guide to working safely near Overhead Power Lines

A Guide to working safely near Overhead Power Lines A Guide to working safely near Overhead Power Lines 1 Please Note This information is for guidance only and is not to be taken as an expression of the law. It should be read in conjunction with the Workplace

More information

CAMBERWELL HOCKEY Strategic Plan

CAMBERWELL HOCKEY Strategic Plan CAMBERWELL HOCKEY Plan 2017-2021 2 CAMBERWELL HOCKEY Plan 2017-2021 Over the next four years, our strategy will lay the foundation for our Club to work as a collective. It will inspire us to recognise

More information

Electrical Shore Connections

Electrical Shore Connections RULES FOR CLASSIFICATION OF Ships / High Speed, Light Craft and Naval Surface Craft PART 6 CHAPTER 29 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Electrical Shore Connections JULY 2014

More information

PLAY. SPORT. AUSTRALIA. One Sailing Case study

PLAY. SPORT. AUSTRALIA. One Sailing Case study PLAY. SPORT. AUSTRALIA. One Sailing Case study This case study provides an overview of the planning, delivery process and outcomes of the One Sailing project undertaken by Australian Sailing (formerly

More information

Policy Redesign Project. Plant Safety Policy. Table of Contents

Policy Redesign Project. Plant Safety Policy. Table of Contents Policy Redesign Project All policies and procedures are being reviewed as part of this project. This document is pending review, but remains in effect until the review is carried out. Plant Safety Policy

More information

Good things come in threes

Good things come in threes 3 Hardware for specialty gases Equipment, supply systems and services for specialty gases Good things come in threes 02 Hardware for specialty gases Everything under one roof The complete equipment range

More information

STCP 08-2 Issue 004: Circuit Live Trip & DAR Tests

STCP 08-2 Issue 004: Circuit Live Trip & DAR Tests STCP 08-2 Issue 004: Circuit Live Trip & DAR Tests STC Procedure Document Authorisation Party Name of Party Representative Signature Date National Grid Electricity Transmission SP Transmission Ltd Scottish

More information

Strategic Plan

Strategic Plan Strategic Plan 2016-2020 President s Message On behalf of the Board and staff I am very pleased to present the Ballarat Golf Club Strategic Plan 2016-2020 (the Plan) to the members. The Plan has been

More information

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper April 2013 Section A - All questions carry equal marks. Answer all three questions. Show all calculations. Q.1 The electrical installation in a small food retail outlet is scheduled

More information

High Pressure Compressed Air and Gas Solutions

High Pressure Compressed Air and Gas Solutions High Pressure Compressed Air and Gas Solutions Intelligent Air Technology World leaders in the manufacture and commissioning of high pressure compressors for industry It is not by accident that CompAir

More information

CONTRACTOR SAFETY INDUCTION HANDBOOK

CONTRACTOR SAFETY INDUCTION HANDBOOK CONTRACTOR SAFETY INDUCTION HANDBOOK As a valued contractor for Total Group we would ask that you read and carefully consider the details included in this document. Total Group carry out work for a number

More information

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Advanced Test Equipment Rentals ATEC (2832) OMS 600 Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMS 600 Continuous partial discharge monitoring system for power generators and electrical motors Condition monitoring

More information

Welcome to MUR Motorsports

Welcome to MUR Motorsports Welcome to MUR Motorsports Welcome to MUR Motorsports Thank you for your interest in MUR Motorsports. In this prospectus, it is with pleasure I present detailed information on the team, a strategy for

More information

Connect Activate Inspire

Connect Activate Inspire Connect Activate Inspire Join with us to get your community walking Proudly supported by Join Heart Foundation Walking as a Host Organisation Heart Foundation Walking is Australia s largest free walking

More information

W WEST COAST FEVER ASSISTANT COACH / ACADEMY HIGH PERFORMANCE COACH

W WEST COAST FEVER ASSISTANT COACH / ACADEMY HIGH PERFORMANCE COACH Employer Reports to Department Location Position Overview Core Responsibilities West Coast Fever Netball Club Executive Officer - West Coast Fever and West Coast Fever Head Coach West Coast Fever Based

More information

Aiming for Zero Road Worker Safety. Mark Pooley Highways Agency Road Worker Safety Programme Manager Monday 11 June 2012

Aiming for Zero Road Worker Safety. Mark Pooley Highways Agency Road Worker Safety Programme Manager Monday 11 June 2012 Aiming for Zero Road Worker Safety Mark Pooley Highways Agency Road Worker Safety Programme Manager Monday 11 June 2012 1. Road Worker Safety Strategy. RWS Strategic Target No. 1: achieve a substantial

More information

Reaching new heights in Fall Protection Solutions.

Reaching new heights in Fall Protection Solutions. Reaching new heights in Fall Protection Solutions. About How high is too high? For us, raising the levels of safety and protection offered to those working at height knows no limits. We haven t just watched

More information

NORTHERN POWERGRID. Distribution Safety Rules 2015 Edition

NORTHERN POWERGRID. Distribution Safety Rules 2015 Edition NORTHERN POWERGRID Distribution Safety Rules 2015 Edition These rules shall be read in conjunction with the Operational Practice Manual and/or indicated Operational Guidance. Refer to the index for supplementary

More information

Development and Evolution of an Asset Management Organization

Development and Evolution of an Asset Management Organization Development and Evolution of an Asset Management Organization Art Kruppenbacher Manager Asset Management October 21, 2015 About the Iberdrola Group Headquartered in Spain 109-year history 28,000 employees

More information

Gas Network Craftsperson

Gas Network Craftsperson Gas Network Craftsperson Unit EIAU016 Carrying out Fault Diagnosis on Electrical Equipment and Circuits This assessment specification has been developed as part of the network maintenance craftsperson

More information

How volunteer organisations can comply with the model Work Health and Safety Act LEGISLATIVE FACT SHEET SERIES

How volunteer organisations can comply with the model Work Health and Safety Act LEGISLATIVE FACT SHEET SERIES How volunteer organisations can comply with the model Work Health and Safety Act LEGISLATIVE FACT SHEET SERIES Overview This fact sheet provides information about what volunteer organisations need to do

More information

Newtown Neighbourhood Centre

Newtown Neighbourhood Centre Policy Name Policy Number 1.10.1.1 Relevant procedures Work Health and Safety All procedures relating to the health, safety and well being of individuals in the workplace are relevant to this policy. Author

More information

INSPECTION & NON-DESTRUCTIVE TESTING

INSPECTION & NON-DESTRUCTIVE TESTING INSPECTION & NON-DESTRUCTIVE TESTING Stork delivers experienced and efficient Inspection and NDT solutions; as a tailored package or a standalone service. WWW.STORK.COM 1 GLOBAL SERVICE WITH A LOCAL PRESENCE

More information

EDUCATION DEPARTMENT ACCU-TEST

EDUCATION DEPARTMENT ACCU-TEST ABN 17 100 208 964 EDUCATION DEPARTMENT ACCU-TEST GAS SAFETY SHUT OFF SYSTEM Operating & Installation Manual Head Office (Melbourne) Sydney Brisbane (Distributor) 1/5 Samantha Court 2/14 Welder Road 17

More information

GAS PIPELINE SAFETY GUIDE.

GAS PIPELINE SAFETY GUIDE. GAS PIPELINE SAFETY GUIDE. Date of issue 27/02/2017 Date of next review 27/02/2018 Page 1 Vector Limited 2017 Gas Pipeline Safety Guide February 2017 CONTENTS CONTENTS...2 WORKING SAFELY... 3 Your Legal

More information

Best Practice RBI Technology Process by SVT-PP SIMTECH

Best Practice RBI Technology Process by SVT-PP SIMTECH Best Practice RBI Technology Process by SVT-PP SIMTECH We define the best practice in RBI as a proactive technology process which is used to formally and reliably optimise the inspection efforts for each

More information

SUPPLIER HEALTH AND SAFETY. Supporting a healthy and safe working environment for our people and customers

SUPPLIER HEALTH AND SAFETY. Supporting a healthy and safe working environment for our people and customers SUPPLIER HEALTH AND SAFETY Supporting a healthy and safe working environment for our people and customers Document Template Control Prepared by Georgina East May 2017 Date Approved by May 2017 Mark Beder

More information

Safe work method statements

Safe work method statements Information about Safe work method statements How to prepare and use a safe work method statement (SWMS) for high risk construction work (HRCW) and who needs to prepare one. October 2018 Key concepts Hazard

More information

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY Approved by the Trustees: November 2016 Health and Safety Policy Introduction The main piece of health and safety legislation is the Health and Safety

More information

New Zealand Thoroughbred Racing (NZTR) Job Description

New Zealand Thoroughbred Racing (NZTR) Job Description New Zealand Thoroughbred Racing (NZTR) Job Description Position Director, NZTR Board External and Internal Key Relationships Internal: NZTR CEO Managers & Staff of NZTR External: NZ Racing Board (NZRB)

More information

OUR TRIATHLON VISION

OUR TRIATHLON VISION OUR TRIATHLON VISION 2 INTRODUCTION Triathlon is a fast-growing, modern and dynamic Olympic and Paralympic sport. From the first modern triathlon in San Diego in 1974 the sport has evolved quickly, making

More information

TYRO ACTIVATE TYRO ACTIVATE P A R T N E R P R O G R A M T A P P P A R T N E R P R O G R A M T A P P

TYRO ACTIVATE TYRO ACTIVATE P A R T N E R P R O G R A M T A P P P A R T N E R P R O G R A M T A P P TYRO AC TIVATE PARTNER PROGR AM TAPP Tyro s partners have been the foundation of our success, from when we brought on our first integrated POS partner in 2007, until today where we ve grown to have over

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

Plant Isolation Lock out/tag out Procedure

Plant Isolation Lock out/tag out Procedure Plant Isolation Lock out/tag out Procedure Related Policy Responsible Officer Approved by Work Health and Safety Policy Approved and commenced November, 2014 Review by November, 2017 Responsible Organisational

More information

WHS PROCEDURE P Plant Isolation. Approved by: Ruth Hampton Review Date: 6 th December 2015

WHS PROCEDURE P Plant Isolation. Approved by: Ruth Hampton Review Date: 6 th December 2015 5 WHS PROCEDURE P29-02 Page 1 of 7 Issue: 2 1. Intent The Salvation Army Australia Eastern Territory (TSA-AUE) is committed to the provision of a safe, healthy and injury free environment within the mission

More information

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015 5 WHS PROCEDURE P21-01 Page 1 of 7 Issue: 2 1. Intent The Salvation Army Australia Eastern Territory (TSA-AUE) is committed to the provision of a safe, healthy and injury free environment for all persons

More information

" High Voltage Switch Yards & How Safe are these really" <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd>

 High Voltage Switch Yards & How Safe are these really <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd> " High Voltage Switch Yards & How Safe are these really" High Voltage Forum Brisbane 2013 Duty of Care As part of an asset owner Duty of care

More information

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving

More information

BACCHER CERTIFICATES / CONTENTS CERTIFICATES / STATUS CONTENTS. l TRAFFIC ACCOMMODATION. ROAD SERVICES (PTY) LTD Your Vision Our Reality!

BACCHER CERTIFICATES / CONTENTS CERTIFICATES / STATUS CONTENTS. l TRAFFIC ACCOMMODATION. ROAD SERVICES (PTY) LTD Your Vision Our Reality! CERTIFICATES / CONTENTS CERTIFICATES / STATUS CONTENTS CONTENTS / CERTIFICATION BACKGROUND 2 3 ROAD SIGNS 4 REGULATORY SIGNS WARNING SIGNS 6 9 INFORMATION SIGNS GUIDANCE SIGNS TOURISM SIGNS ROUTE MARKERS

More information

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats Assisting in modifying and adding electrical circuits in yachts and boats Overview This standard identifies the competences you need to assist with the modification or addition of electrical circuits in

More information

Level 3 Diploma in Moving Loads in Construction. Qualification Specification

Level 3 Diploma in Moving Loads in Construction. Qualification Specification Qualification Specification ProQual 2017 Contents Page Introduction 3 Qualification profile 3 Qualification structure 4 Centre requirements 4 Support for candidates 5 Assessment 5 Internal quality assurance

More information

MANAGING ARC FLASH: A Risk Management Approach. Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane

MANAGING ARC FLASH: A Risk Management Approach. Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane MANAGING ARC FLASH: A Risk Management Approach Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane 1 ARC FLASH RELEVANCE? Higher Safety Awareness & OHS Legislation Statistics

More information

Western Australian Swimming Association Inc. strategic plan SWIMMING AN ESSENTIAL PART OF THE WESTERN AUSTRALIAN WAY OF LIFE

Western Australian Swimming Association Inc. strategic plan SWIMMING AN ESSENTIAL PART OF THE WESTERN AUSTRALIAN WAY OF LIFE Western Australian Swimming Association Inc. strategic plan 2015 2018 SWIMMING AN ESSENTIAL PART OF THE WESTERN AUSTRALIAN WAY OF LIFE Swimming WA Vision Swimming is an essential part of the Western Australian

More information

Sit-Stand Workstations. Your guide to keeping up with the latest in workstation technology

Sit-Stand Workstations. Your guide to keeping up with the latest in workstation technology Sit-Stand Workstations Your guide to keeping up with the latest in workstation technology 1 Contents The Height Adjustable Trend Why height adjustable workstations are becoming so popular What s in a Name?

More information

Logan City Council Planning for Tennis Together

Logan City Council Planning for Tennis Together Logan City Council Planning for Tennis Together February 2016 Introduction Tennis Queensland and Tennis Australia are seeking the opportunity to proactively work with the Logan City Council (LCC) to address

More information

Berwick Health and Education Precinct: Casey Amendment C207 (Part 1) Submission to Planning Panels Victoria

Berwick Health and Education Precinct: Casey Amendment C207 (Part 1) Submission to Planning Panels Victoria Berwick Health and Education Precinct: Casey Amendment C207 (Part 1) Submission to Planning Panels Victoria August 2018 CONTENTS 1 Executive summary... 1 2 Summary of the amendment... 2 3 Submission...

More information

City of Perth Cycle Plan 2029

City of Perth Cycle Plan 2029 Bicycling Western Australia s response City of Perth Cycle Plan 2029 2012-2021 More People Cycling More Often ABOUT BICYCLING WESTERN AUSTRALIA Bicycling Western Australia is a community based, not-for-profit

More information

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction Locate and avoid supply apparatus for Utilities Network Construction Overview This national occupational standard defines the competence involved in locating and avoiding supply apparatus by using appropriate

More information

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems Performing Engineering Operations QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems Learner Name: 2013 Excellence, Achievement & Learning Ltd EAL Assessment Route

More information

TVPPA Lineman Apprenticeship Program

TVPPA Lineman Apprenticeship Program Self-Study Modules Unit 1 Unit 2 Unit 3 Unit 4 Lineman Apprenticeship Program Skills Labs Pre-Apprentice Assessment Digger Derrick Training Fundamentals Lab 1 Construction Lab 2 Operations Lab 3 Underground

More information

STCP 01-1 Issue 005 Operational Switching

STCP 01-1 Issue 005 Operational Switching STCP 01-1 Issue 005 Operational Switching STC Procedure Document Authorisation Party National Grid Electricity Transmission plc Name of Party Representative Signature Date Formatted: Font: Arial Bold,

More information

SCHNEIDER AUTOMATIC CIRCUIT RECLOSER JOB SAFETY ANALYSIS

SCHNEIDER AUTOMATIC CIRCUIT RECLOSER JOB SAFETY ANALYSIS Title: Schneider Automatic Circuit Recloser Job Safety Analysis Purpose and Scope: This document describes the tests to be carried out before accepting a new or repaired N and W series Schneider Automatic

More information

District Cooling System at Kai Tak Development Content

District Cooling System at Kai Tak Development Content District Cooling System at Kai Tak Development Content Background District Cooling System (DCS) at Kai Tak Benefits of DCS DCS Connection Technical Guidelines for DCS Connection / Supply Rules on District

More information

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE Peter Mason Manager, Coal Mines Technical Services, a division of Mines Rescue Pty Ltd, Australia ABSTRACT The NSW Mines Rescue

More information

STCP 01-1 Issue 008 Operational Switching

STCP 01-1 Issue 008 Operational Switching STCP 01-1 Issue 008 Operational Switching STC Procedure Document Authorisation Party Name of Party Representative Signature Date National Grid Electricity Transmission plc SP Transmission plc Scottish

More information

PRO Lifting Operations

PRO Lifting Operations MS&L Procedure PRO-4.5-0001-1-06 Lifting Operations Document Owner: Bill Kruesi HSSE Manager - Asset Mgmt. Owen Quake ANZ Engineering Authority Approved By: Bill Kruesi HSSE Manager - Asset Mgmt. Control

More information

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 5: Dive supervisor. Australian/New Zealand Standard

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 5: Dive supervisor. Australian/New Zealand Standard AS/NZS 2815.5:2013 Australian/New Zealand Standard Training and certification of occupational divers Part 5: Dive supervisor Superseding AS 2815.5 2006 AS/NZS 2815.5:2013 AS/NZS 2815.5:2013 This Joint

More information

Agreement between. The London Organising Committee of the Olympic Games and Paralympic Games. and

Agreement between. The London Organising Committee of the Olympic Games and Paralympic Games. and LOCOG: taking action to ensure respect for workers rights in global supply chains Agreement between The London Organising Committee of the Olympic Games and Paralympic Games and Trades Union Congress on

More information

Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks. A Report on Best Practice from TALIS

Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks. A Report on Best Practice from TALIS 1 Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks A Report on Best Practice from TALIS 2 Introduction For a generation focused on smart systems and big data, it

More information

To comply with the OHS Act, the responsible manager must carry out and document the following:

To comply with the OHS Act, the responsible manager must carry out and document the following: Owner: Manager Health, Wellbeing and Safety Last Update: 10 January 2018 Contents 1. Purpose... 1 2. Minimum Compliance Requirements... 1 3. Definitions... 2 4. Legislative requirements under the OHS Act

More information

Nottingham Cycle City Frequently Asked Questions

Nottingham Cycle City Frequently Asked Questions Nottingham Cycle City Frequently Asked Questions About the scheme How much money is to be spent on cycling? And where is the money from? We have 6.1 million in Growth Fund which we will be investing directly

More information

Infrared Thermography Inspection Guidelines. Date Issued:

Infrared Thermography Inspection Guidelines. Date Issued: Infrared Thermography Inspection Guidelines Date Issued: 2002 01 29 Created By: Approved By: L. Henderson G. Durnford Table Of Contents Table Of Contents...i POLICY STATEMENT...1 APPLICABLE INTERNATIONAL

More information

B S Glass Ltd Safety procedures- outsourced Workplaces

B S Glass Ltd Safety procedures- outsourced Workplaces B S Glass Ltd Jan 17 B S Glass Ltd Safety procedures- outsourced Workplaces Index - - - - - - - - Page No On Site safety - - - - - - - - - - - - - - - - - - - Content 3. 1.00 Health and Safety Mission

More information

Leakage Current Testing Is it right for your application?

Leakage Current Testing Is it right for your application? Leakage Current Testing Is it right for your application? Introduction The Leakage Current test (LCT for short) is most often specified to be performed as a type test in a design or engineering laboratory

More information

Role Profile. Chief Executive of Blackburn Youth Zone. Chair and Board of Blackburn Youth Zone

Role Profile. Chief Executive of Blackburn Youth Zone. Chair and Board of Blackburn Youth Zone Role Profile Job Role: Accountable to: Key Relationships: Chief Executive of Blackburn Youth Zone Chair and Board of Blackburn Youth Zone Youth Zone Chair and Board, Youth Zone Senior Management Team,

More information

CITB Construction site safety update

CITB Construction site safety update D: High risk activities Underground and overhead services This text replaces the text from the current GE700 2015, Section D, Chapter D08, Underground and overhead services, pages 133 to 136. 8.6 Overhead

More information

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks Selecting the right MCC equipment leads to improved plant safety, helping protect people and

More information

UK Contractors Group Mobile Elevating Work Platforms Good Practice Toolkit June June 2015 Page 1 of 16

UK Contractors Group Mobile Elevating Work Platforms Good Practice Toolkit June June 2015 Page 1 of 16 UK Contractors Group Mobile Elevating Work Platforms Good Practice Toolkit www.ukcg.org Page 1 of 16 Contents Foreword Reference Material Initial Considerations Planning and Preparation for MEWP Activities

More information

Report to COUNCIL for decision

Report to COUNCIL for decision 17 152 Title: Section: Prepared by: Olympic Pool Business Case Community & Recreation Andrew White (Community & Recreation Manager) Meeting Date: 18 May 2017 Legal Financial Significance = Medium Report

More information

Working with Grantors

Working with Grantors Working with Grantors Introduction Welcome to this Grantors Code of Practice. SSE s core purpose is to provide the energy that people need in a reliable and sustainable way. A key component of this is

More information