Perimeter soil gas emissions criteria and associated management
|
|
- Myles Morgan
- 5 years ago
- Views:
Transcription
1 Ltd Perimeter soil gas emissions criteria and associated management
2 Using the ICOP 1. Background concentrations 2. Action limits 3. Compliance limits 4. Investigating gas migration 5. Mitigation options and verification strategies Brief quiz at the end of each section. For 3 lucky winners (drawn out of hat if more than 3 with all correct answers) there will be a 2GB memory stick prize 2
3 What migrating gas can do.. The Darvaza well known locally as Hells Door 3
4 Introduction - conceptual model Distances to residential areas, agricultural or urban sites Waterways Groundwater elevations Geological and hydrogeological conditions - permeability of potential gas migration pathways Risk of flooding, subsidence 4
5 Background concentrations Easy to set at sites with no background methane or carbon dioxide concentrations Difficult at sites with external sources of methane and carbon dioxide Difficult at or adjacent to old dilute and disperse sites the ICOP may not be suitable for these sites 5
6 Setting background can be tricky 6
7 Confounding factors No pre-disposal data? One part of site has different background to another? Active ground gas cycle? Intermittent mines gas from coal and shale seams? CO 2 natural respiration in topsoil, degassing from limestone and chalk Historically, well condition and data quality poor? 7
8 Changing background Lining a landfill changes the local background conditions because gas generated in the subsurface that has previously diffused to surface unimpeded now has to migrate around the impermeable lining 8
9 Key phase to collect background New cells must have perimeter boreholes before liner placed Four week period between the end of liner construction and waste deposit -intensive background monitoring is recommended Prior to the onset of methanogenic conditions within specific cells (should be cross referenced to on-site data) 9
10 Setting background (1) Background concentrations will be set on a monitoring well basis This has two advantages: 1. No discussion of zonal boundaries; 2. No complicated statistics are required to deal with multiple datasets that may not have equivalent data There is still merit in looking both at location specific and site/zone data 10
11 Setting Background (2) Sampling frequency is monthly Ideally 2 years background data prior to waste placement. 1 year minimum to understand seasonal variations. High monitoring frequency required after a liner installed (and before waste is placed) background data points a minimum before statistics employed 11
12 Setting Background (3) Background is the T max concentration stable datasets unstable datasets 12
13 13
14 Two dataset types Stable datasets with an approximately normal distribution - statistics can be used (later presentation) Unstable datasets - greater than 10% v/v fluctuations in soil gas concentrations may occur in short periods of time. Such data may exhibit a saw tooth pattern over time. 14
15 Stable dataset Background is the T max concentration T max CO 2 is 4.0%, T max CH 4 is 0.0% 15
16 Unstable dataset Mean: 6%. 95th percentile:19%. 95th percentile limit to maximum data value is >10% v/v 16
17 15% filtered unstable dataset Mean: 21%; 95%ile: 26% T max : 27% After filtering, statistics can be applied 17
18 Other unstable datasets Some datasets do not lend themselves to the use of statistics One common example is a dataset that has mainly zero values with an occasional peak that immediately disappears these will be outliers and removed so background will be zero. CCS scoring will need to account for rapid return to zero 18
19 Questions 1. When is it most important to get a good background dataset? 2. What is the minimum recommended number of datapoints before statistics are employed? 3. What type of site won t fit into the ICOP methodology? 4. What is the background concentration? 19
20 Action Limits 20
21 Action Limits (operator) First indication that conditions are outside the norm maybe that the landfill not operating properly, or natural variation Requires some action or attention from the operator Gas Management Plan Gives operator time to react before Compliance Limits breached 21
22 Action Limits (regulator) Action Limits not included in EPR permit Required as an integral part of a site s gas management plan If Action Limits exceeded, regulator not required to be involved, but if Compliance Limits are subsequently breached, then the actions taken will be scrutinised 22
23 Setting Action Limits Should allow for naturally occurring variation in methane concentrations from baseline conditions; and Should give sufficient time to take corrective or remedial action before regulatory Compliance Limits are breached 23
24 Action Limits - stable environments T max (background) methane concentration plus 0.5% 1% carbon dioxide above the T max if it is less than 5% 2% carbon dioxide above the T max if it is between 5 10% etc No Action Levels for T max carbon dioxide concentrations above 25% 24
25 Action Limits - unstable environments»unstable environments are suggested to occur when the range in concentrations values (between high and low data) is >8% For every well the action level for methane or carbon dioxide will be the T max concentration 25
26 Re-monitor First response Is the reading repeatable? Is the well and the sampler fit for purpose? Is the gas field balanced, with suction being applied to perimeter wells Has a low pressure front just come through? Has it been raining a lot? Are the engines performing - has total gas flow decreased recently? 26
27 Is well fit for purpose? Valve or end cap is damaged, seized, open or missing prior to sampling Well cap is loose or a perished rubber bung If the well cap is threaded, it is not tight and it doesn t have an o-ring seal If it is a combined well, Waterra tubing is protruding and there is no well cap No hydrated bentonite around the well Slotted screen section visible above ground Annulus has cracked or ground has dropped away around edge of well 27
28 Is sampler trained? Well Differential pressure before Carbon dioxide % Carbon dioxide trend Methane % Methane trend Oxygen % Differential pressure after Comment Stable 0 Absent Balance gas >85% Stable 0 Absent Balance gas >82% Peaked then Slight fall Slight increase 0 Absent Low permeability. Close to ambient air composition. 0 Absent Similar to ambient air composition Stable 0.6 Falling Similar to ambient air composition Slight increase 2.2 Falling Balance gas >80.5% Stable 0 Absent Balance gas > 88% Stable 0 Absent Balance gas >80.5% Stable 0 Absent Balance gas >82.5% 28
29 If Action Limit breached Refer to Gas Management Plan this should have pre-defined actions Re-monitor Check data quality (see above) Increase monitoring frequency Check easy wins gas abstraction system More actions discussed later 29
30 Gas Management Plan actions 30
31 Timeline Medium risk site Outcome Action Deadline Additional Monitoring Concentration above action level Re-monitor 48 hours Concentration above action level Check gas field 48 hours Concentration still above action level Verify conceptual model and plan for extended pathway assessment, if required 1 week Extended pathway assessment Concentration above action level Investigate sources and pathway 2 week fieldwork, 4 weeks report Concentration above action level Concentration still above action level In depth assessment of containment performance Verify conceptual model and review system performance. 3 week fieldwork, 4 weeks report 5 week report 31
32 Questions 1. What is the first thing to do if an Action Limit is breached? 2. For the purposes of setting action limits, what % difference between low and high concentrations indicates unstable conditions? 3. What is the most common problem with well infrastructure identified during monitoring? 4. What is the offset for methane above background (stable dataset)? 32
33 Compliance Limits 33
34 Compliance Limits These will be in the permit (can still use existing LFTGN03 limits) Breach taken as indication that a compliance failure of gas control has occurred Above a compliance limit presumption that elevated methane is from the landfill until proved otherwise 34
35 Setting Compliance Limits For every perimeter well under post-critical gas production conditions, the Compliance Limit will be 1% methane above the T max methane concentration No Compliance Limits where background methane is > 10% No Compliance Limits for carbon dioxide 35
36 Unstable datasets ICOP methodology not appropriate 36
37 Gas Management Plan actions 37
38 Safety first If potential receptors are close to the landfill and if there is any uncertainty then take the safety first option, which would be to instigate actions in the next box down 38
39 Timeline High risk site Outcome Action Deadline Additional Monitoring Concentration above compliance level Re-monitor 6 hours Concentration above compliance level Check gas field 24 hour Concentration above compliance level Verify conceptual model and plan 48 hour for extended pathway assessment, if required Extended pathway assessment Concentration above compliance level Off-site receptor analysis and risk 1 week action plan report Concentration above compliance level Investigate sources and pathway 1 week fieldwork, 3 weeks report Concentration above compliance level In depth assessment of containment performance 2 week fieldwork, 3 weeks report 4 week report Concentration still above compliance level Verify conceptual model and review system performance. Concentration still above compliance level Additional contingency actions 4 week report 39
40 Timeline for event LANDFILL OPERATOR ACTIONS ACTION LEVEL COMPLIANCE LIMIT Tmax +0.5 % Methane Tmax + x% carbon dioxide Or Tmax carbon dioxide ACTION e.g., resampling Tmax +1% Methane INCREASED ACTION* ENVIRONMENT AGENCY ACTIONS ACTION LEVEL COMPLIANCE LIMIT Potential CCS SCORE Tmax +0.5% Methane Tmax + x% carbon dioxide Or Tmax carbon dioxide Tmax +1% Methane NO ACTION ACTION** 40
41 Dilute and disperse sites ICOP methods may be appropriate but should accurately reflect the site conceptual model Investigation and mitigation methods may be different Proportionate risk based response may be appropriate (next slide) 41
42 Hazard assessment methodology British Standard 8485:2007. This uses the concept of hazardous gas flow rate Q hg Q hg = C hg /100 * q 42
43 Questions 1. What is the methane off-set above background for Compliance Limits? 2. Above what methane concentration are limits not appropriate? 3. Above a Compliance Limit, where is the gas presumed to have come from? 4. Are LFTGN03 methods still valid? 43
44 Investigating gas migration 44
45 Gas migration Gas migration in soil is primarily controlled by pressure gradients - along paths of least resistance, from areas of high to low pressure The rate of gas migration depends on the gas pressure in the source area, and the effective gas-phase permeability of the subsurface Diffusive transport is typically much lower than pressure-driven flow in a permeable porous medium 45
46 Controlling characteristics Length of flow path Formation permeability (equivalent porous media or fracture controlled) Permeability variations (i.e., sand and clays); Presence of a near-surface capping layer Water table depth and fluctuation The presence of barriers to lateral flow Preferential pathways 46
47 Conceptual model At operational and closed landfills the application of a negative pressure should mitigate against gas migration The potential for gas migration out of the landfill only exists in pockets of waste that are not under the influence of the gas abstraction system 47
48 Physical conceptual model Atmospheric pressure Recent weather Any activities in the area that may affect readings Pressure within the well Reading variability Any odours Groundwater levels Flow rate Oxygen Balance gas - any input of landfill gas comprising ~ 60% methane and 40% carbon dioxide would displace and reduce the 80% of nitrogen in the pore space Graphs should be used to identify trends 48
49 Detailed investigation Trace component testing CH 4 : CO 2 ratio Borehole purging Helium Isotopes carbon and tritium (best if enough CH 4 ) 14 C Activity (Percent Modern) δ 13 C (%o) CH 4 CO 2 CH 4 CO 2 GA ± ± Well ± ± H of the CH 4 Bq/litre H 2 O (TU) 1730 ± ± ± ±
50 Source term management Total abstraction m 3 - gas losses or volume increasing? Site vacuum, operation of carrier mains, is the gas mix at the Plant richer than normal etc. Assess status of gas extraction wells (open, percentage open, closed) and condition is satisfactory If wells open and well-maintained but gas production has increased, check for interference suction on wells Condensate build up in gas carrier pipe work If operational model has changed, full performance assessment may be required 50
51 Quick reference Process Likely Gas Migration Unlikely Gas Migration Differential High pressure in the Pressure greater landfill, low pressure in than 30mB the Borehole in the Borehole Presence of Helium Presence of Chlorinated hydrocarbons in off-site wells Carbon isotopes If no Helium is found, this does not mean that the gas has migrated Chlorinated hydrocarbons are most likely to have come from the landfill 14 C is found to be modern and the gas is biogenic Low pressure in the landfill, High pressure Helium present in the borehole. Low 14 C level, not biogenic Tritium isotope High Tritium level. Background Tritium Level Carbon Dioxide 60:40 CH 4 : CO 2 ratio High flow with either ratio. with high flow CH 4 or CO 2 but not both Comments Diffusion can drive a gas against a pressure gradient. Not all non-landfill gas sources contain Helium. If no chlorinated hydrocarbons are found, they may not be present in the landfill, or may be adsorbed en route. Data is rarely conclusive for CO 2 because this does not discriminate mixed sources or influences Need enough methane to get adequate tritium sample If the gas is flowing quickly over a short distance the amount of adsorption or methane oxidation will be limited. 51
52 Questions 1. What is the primary controlling factor for gas migration? 2. What other factor controls the rate of gas migration? 3. What gas ratio can be worth investigating? 4. What is the most useful isotope and what is the limitation of this technique? 52
53 Mitigation strategies 53
54 Cost should be proportionate to risk Risk Gas into building Gas into confined space Gas off-site Adverse CCS score Cost Maximise gas field efficiency Additional monitoring Additional on-site gas abstraction Off-site gas abstraction Risk Ranking Very high High Medium High Cost Ranking Low Medium High Very high 54
55 CIRIA guidance Risk to housing 55
56 Risk to confined spaces The majority of the incidents associated with landfill gas migration involve the accumulation of gas in confined spaces, such as within buildings, culverts, and manholes 56
57 Risk of gas off-site CCS scoring (see later presentation) Corporate image 57
58 Off-site gas management If on-site gas management is as good as it can be and there is still a loss of containment, then an off-site gas management plan will be required Two types Passive systems are not normally used to manage gas and are now typically viewed as a poor solution 58
59 Active systems Well or trench vents extract gas and form a negative pressure gradient, or air is injected to form a positive pressure gradient Use biofilter to oxidise abstracted methane Biowindow to release pressure in area of poor gas control 59
60 Summary Background concentrations being set on a well by well (or zonal) basis Statistical techniques are proposed to define background limits for stable and unstable data No Compliance (formerly trigger) Limits need be set for carbon dioxide Carbon dioxide data should continue to be collected and assessed against a lower Action (formerly control) Limit 60
61 Questions 1. What is the off-site location where the majority of LFG gas incidents occur in? 2. What is required when all gas management options have been explored and there is still migration? 3. What kind of system is now viewed as a poor solution? 61
Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study
Measurement of Representative Landfill Migration Samples at Landfill Perimeters: A Case Study Breda M. Kiernan, PhD. National Centre for Sensor Research, Dublin City University Glasnevin Dublin 9 Ireland
More informationUsing ternary plots for interpretation of ground gas monitoring results
Ground Gas Information Sheets Using ternary plots for interpretation of ground gas monitoring results Ground Gas Information Sheet No 1 Paper 1.0 30/7/2018 Keywords: ground gas, ternary, landfill gas,
More informationProtective Atmospheres, Measurement Technologies and Troubleshooting Tools
Protective Atmospheres, Measurement Technologies and Troubleshooting Tools Furnace atmospheres are critical to meet metallurgical specifications defined by control processes. The makeup of a furnace s
More informationThe Environmental Protection Group Limited
The Environmental Protection Group Limited March 2012 EPG Limited No part of this document may be reproduced without the prior permission of EPG Limited. Landfill Gas Technical Discussion Note 2 V1.0 1
More informationGoaf Inertisation and Sealing Utilising Methane from In-Seam Gas Drainage System
University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2011 Goaf Inertisation and Sealing Utilising Methane from In-Seam Gas Drainage System
More informationExplosive gas migration monitoring for a sanitary landfill facility.
3745-27-12 Explosive gas migration monitoring for a sanitary landfill facility. (A) Applicability and implementation. This rule applies to the following: (1) The owner or operator of a sanitary landfill
More informationOhio EPA. Division of Air Pollution Control. Engineering Guide #78. (also known as DSIWM Guidance Document #1001 and #1002)
Ohio EPA Division of Air Pollution Control Engineering Guide #78 (also known as DSIWM Guidance Document #1001 and #1002) Question: The Standards of Performance for New Stationary Sources (NSPS) for municipal
More informationErrata. Publication C665 Assessing risks posed by hazardous ground gases to buildings
Publication C665 Assessing risks posed by hazardous ground gases to buildings Errata Readers are advised of the following corrections to the document: Figure 1.1, page 5 Figure revision (see attached page)
More informationMETHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES
METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES 1. Applicability and Principle 1.1 Applicability. This method applies to the analysis of carbon dioxide
More informationMETHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the
287 METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling and analytical)
More informationInvestigations into the identification and control of outburst risk in Australian underground coal mines
Investigations into the identification and control of outburst risk in Australian underground coal mines Dennis J Black 1,2 1. Principal Consultant, PacificMGM, Bulli NSW 2516, Australia 2. Honorary Fellow,
More informationThe FTC Gas Model For Balancing Landfill Gas Extraction
The FTC Gas Model For Balancing Landfill Gas Extraction Development Background & Overview FTC is an environmental consultancy with specialist landfill related expertise over 20 years Presentation assumes
More informationIntroduction. Geomembrane lining systems are used in a variety of different applications. Landfill Lining Landfill Capping Salt Piles Lagoons / Ponds
Contents 1. Introduction/Overview 2. Traditional Methods of Anchoring Geomembrane Liners 3. What can go wrong? 4. Net Down 5. Theory and how Net Down works 6. Installation Details 7. Technical Information
More informationtechnical bulletin CL : AIRE Complete Continuous Monitoring in Underfloor Voids TB 16 (December 2017)
CL : AIRE TB 16 (December 2017) CL:AIRE s describe specific techniques, practices and methodologies currently being employed on sites in the UK. This bulletin explains a best practice approach using complete
More informationGasClam: Continuous Ground-Gas Monitoring Becomes A Reality
GasClam: Continuous Ground-Gas Monitoring Becomes A Reality Introduction Ground-gas monitoring is an important aspect of contaminated land site investigation and landfill management as the data is critical
More informationDIRECTIONAL DRILLING
DIRECTIONAL DRILLING 1. General. Installation of pipelines through the levee embankment using directional drilling technology is prohibited. Installation of pipelines through a flood control project foundation
More informationDiscussion and guidance on the definition and qualification of porous loads
SUMMARY Porous Loads requiring Sterilisation are often a Critical Control Point for the manufacture of Sterile products. Particularly Aseptically filled products. Regulatory guidance in this area is not
More informationSWI NAPL Recovery. Cemcor Environmental Services. represented by. Contact: Craig Marlow Phone Cell
SWI NAPL Recovery represented by Cemcor Environmental Services Contact: Craig Marlow Phone 419.867.8966 Cell 419.349.7970 Email cemarlow@att.net Physical mechanisms of SWI Injection in the saturated zone
More informationInitial Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1
Initial Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1 Ottumwa-Midland Landfill Prepared for: Ottumwa-Midland Landfill 15300 130 th Street Ottumwa, Iowa 52501 Prepared by: SCS
More informationMaterials Performance November Nitrogen generator inhibits corrosion within fire protection systems
Materials Performance November 2014 Nitrogen generator inhibits corrosion within fire protection systems When dry and pre-action fire protection systems experience internal corrosion in their piping network,
More informationThe Role of Gas Monitoring in the Prevention and Treatment of Mine Fires
University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 28 The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires D. Brady
More informationApplied Technology and Best Practices in CEE. Conference
Geoinform Applied Technology and Best Practices in CEE Conference THE DEVELOPMENT OF MUD GAS LOGGING SYSTEMS AND THEIR ROLE IN HYDROCARBON EXPLORATION Sándor Pugner GEOINFORM Ltd. Budapest, 17 November
More informationVermin, Insects and Scavenging Birds Management Plan
VIRIDOR WASTE MANAGEMENT LIMITED Lostock Waste Treatment Plant Vermin, Insects and Scavenging Birds Management Plan CONTENTS 1 Introduction... 2 2 Sources, Releases and Impacts... 3 3 Vermin, Insects and
More informationthe annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).
Bulletin 2011-35 December 20, 2011 Surface Casing Vent Requirements for Wells This bulletin clarifies Section 6.100(4) of the Oil and Gas Conservation Regulations (OGCR) and provide additional surface
More informationApplied Modelling of Ventilation and Gas Management to Increase Production in a Single Entry Longwall Panel
University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2016 Applied Modelling of Ventilation and Gas Management to Increase Production in a
More informationW I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS
PRESSURE BASICS AND CONCEPTS Pressure Basics and Concepts Learning Objectives You will be familiarized with the following basic pressure concepts: Defining pressure Hydrostatic pressure Pressure gradient
More informationA Conceptual Understanding of Leakage During Soil-Gas Sampling
A Conceptual Understanding of Leakage During Soil-Gas Sampling Dominic C. DiGiulio, Ph.D. U.S. Environmental Protection Agency Office of Research and Development National Risk Management Research Laboratory
More informationMETHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the
1151 METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS 1.0 Scope and Application. 1.1 Analytes. Analyte Volatile Organic Compounds (VOC) CAS No. No CAS number assigned 1.2 Scope. This method
More informationAnnual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1
Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1 Ottumwa-Midland Landfill Prepared for: Ottumwa-Midland Landfill 15300 130 th Street Ottumwa, Iowa 52501 Prepared by: SCS ENGINEERS
More informationNiltox Breathing Air Purifier Range
Breathing Air Requirements The main standards affecting breathing air are BSEN529, EN12021 and COSHH. The requirements for a breathing air system are shown in the table opposite and the requirements for
More informationEPA R6 Dive Team Operations Report. San Jacinto Waste Pits Channelview, TX December 9-10, 2015
EPA R6 Dive Team Operations Report San Jacinto Waste Pits Channelview, TX December 9-10, 2015 BACKGROUND The San Jacinto River Waste Pit Site history has been documented in several documents prepared for,
More informationZebron Gas Management
Zebron www.phenomenex.com/gasmanagement What are the key benefits of Zebron filters and traps? The high adsorption capacity of the Zebron Filters removes contaminants from mobile phase gases, reducing
More informationConstruction Dewatering
Construction Dewatering Introduction The control of groundwater is one of the most common and complicated problems encountered on a construction site. Construction dewatering can become a costly issue
More informationSAMPLE MAT Proceedings of the 10th International Conference on Stability of Ships
and Ocean Vehicles 1 Application of Dynamic V-Lines to Naval Vessels Matthew Heywood, BMT Defence Services Ltd, mheywood@bm tdsl.co.uk David Smith, UK Ministry of Defence, DESSESea-ShipStab1@mod.uk ABSTRACT
More informationANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS
Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This
More informationTolent Construction Ltd. Derwent House Lakeside Court Fifth Avenue Business Park Team Valley Gateshead Tyne & Wear NE11 0NL
Tolent Construction Ltd. Derwent House Lakeside Court Fifth Avenue Business Park Team Valley Gateshead Tyne & Wear NE11 0NL Our Ref: _TC_Gas Risk Assessment 22 September 2017 Dear Sirs/Madam, RE: GAS RISK
More informationOxygen Contamination
MPMS Application Note 1014-210 Oxygen Contamination This application note describes potential sources for oxygen contamination in the sample chamber and discusses its possible effects. Molecular oxygen,
More informationSignificant Change to Dairy Heat Treatment Equipment and Systems
Significant to Dairy Heat Treatment September 2008 Page 1 Significant to Dairy Heat Treatment Equipment and Systems September 2008 1 Background Requirements for the assessment of dairy heat treatment equipment
More informationAppendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation
Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly
More informationD.B. Wilson Station CCR Landfill
D.B. Wilson Station CCR Landfill Disposal of Coal Combustion Residuals (CCR) from Electric Utilities Final Rule Closure and Post-closure Care Plan October 11, 2016 Prepared By: Project ID: 160030A Big
More informationCHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS
CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS 5.1 Introduction Using surcharging as the sole soil consolidation mean can take a long time to reach the desired soil settlement. Soil consolidation using prefabricated
More informationThe FLUX-METER: implementation of a portable integrated instrumentation for the measurement of CO 2 and CH 4 diffuse flux from landfill soil cover.
: implementation of a portable integrated instrumentation for the measurement of CO 2 and CH 4 diffuse flux from landfill soil cover. I. Minardi*, E. Giovenali*, L. Coppo*, G. Virgili*, D. Continanza*,
More informationReview of oxygen deficiency requirements for graham s ratio
University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2017 Review of oxygen deficiency requirements for graham s ratio Sean Muller Simtars,
More informationRESEARCH OF LEAK DETECTION SYSTEMS WITH ACCUMULATIVE MEMBRANES
RESEARCH OF LEAK DETECTION SYSTEMS WITH ACCUMULATIVE MEMBRANES V.M.Mjasnikov, S.G.Sazhin, Dzerzhinsky Polytechnic Institute NSTU named after R.E.Alekseev, Dzerzhinsk, Nizhegorodsky region, Russia One of
More informationASTATT10 Carry out air tightness testing on large and complex, high rise and phased hand over zonal buildings
Carry out air tightness testing on large and complex, high rise and phased Overview This standard is for those who carry out air tightness testing and inspection of large and complex buildings, high rise
More informationMEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY
MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY SPORTS & SAFETY BAUER KOMPRESSOREN WHY PRECISE MEASUREMENT
More informationLeak Checking Large Vacuum Chambers
Leak Checking Large Vacuum Chambers Technical Overview Vacuum Technologies Introduction Understanding the pump-down characteristics of a large vacuum vessel is critical for determining whether the vacuum
More informationCORESTA RECOMMENDED METHOD N 6
CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination
More informationMARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE
When there is a problem making consistent product in a carborizing furnace you must consider all the possibilities before replacing the oxygen sensor. In many cases using the sensor and the control instrument
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.
Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography
More informationOctober 16, GRDA CCR Landfill Compliance Report Grand River Dam Energy Center 8142 Hwy 412B PO Box 609 Chouteau, OK Dear Mr.
October 16, 2018 Mr. Mike Bednar Superintendent of Environmental Compliance GRDA-Ecosystems and Education Center PO Box 70 420 Hwy 28 Langley, OK 74350-0070 RE: GRDA CCR Landfill Compliance Report Grand
More informationLecture 8&9: Construction Dewatering
Arab Academy for Science, Technology & Maritime Transport Colleague of Engineering & Technology Construction & Building Engineering CB 523 Methods and Equipment for Construction 1 Lecture 8&9: Construction
More informationEarly evap monitors. Photo courtesy Toyota Motor Sales, U.S.A., Inc.; diagram courtesy University of Toyota
Early evap monitors checked for leaks greater than.040 in. (1mm), but starting in model year 2000, the allowable leak was reduced to.020 in. (.5mm), which was phased in over several years. The reduced
More informationCarbon Dioxide The Other Silent Killer. George Lomax Heath Consultants Incorporated
Carbon Dioxide The Other Silent Killer George Lomax Heath Consultants Incorporated Carbon Dioxide On February 26, 2016 at 9:45 AM a gas company in Warwick County Indiana received a call from a customer
More informationGases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.
Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to
More informationSubparts AA and BB - The Other RCRA Air Rules. Beginners aabb
Subparts AA and BB - The Other RCRA Air Rules Beginners aabb 1 Background Subpart AA - Process vents Subpart BB - Equipment leaks Subpart CC - Tanks, surface impoundments, containers. Also includes Subpart
More informationSubject: FW: 2018 First Quarter Probe/Perimeter Monitoring Report Lena Road Landfill WACS # 44795
Borderieux, Scott From: Thompson, Madison Sent: Wednesday, May 16, 2018 3:48 PM To: Borderieux, Scott Subject: RE: 2018 First Quarter Probe/Perimeter Monitoring Report - Lena
More informationAPPENDIX P U.S. EPA WARM MODEL OUTPUT
APPENDIX P U.S. EPA WARM MODEL OUTPUT Analysis Inputs Version 12 Waste Reduction Model (WARM) -- Inputs Use this worksheet to describe the baseline and alternative MSW management scenarios that you want
More informationProposed Uniform Standards for Equipment Leaks
12 th LDAR Symposium May 15-16, 2012 New Orleans, LA Proposed Uniform Standards for Equipment Leaks Standards Certification Education & Training Publishing Conferences & Exhibits 1 Proposed LDAR Uniform
More informationCTB3365x Introduction to Water Treatment
CTB3365x Introduction to Water Treatment D4b Aeration Doris van Halem Did you know that there are not just gasses in your glass of sparkling coke, but also in the tap water you drink? Welcome to the water
More informationVACUUM TESTING PRECAST CONCRETE MANHOLES
1 OF 5 testing is a quick, safe and practical way to validate manhole system integrity. Manhole sections can be tested at the precast concrete plant prior to delivery or on site prior to backfilling. Here
More informationGas Sampling in the DST
UCRL-ID-129732 Gas Sampling in the DST L. DeLoach M. Chiarappa R. Martinelli B. Glassley January 12, 1998 Lawrence Livermore National Laboratory This is an informal report intended primarily for internal
More informationMass Spec will not Autotune
Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems
More informationHow HSE regulates onshore oil and gas
Health and Safety Executive How HSE regulates onshore oil and gas Paul Bradley (Operations Manager Wells and Mines) Craig Norman (Well Engineering and Operations Inspector) Health & Safety Executive Health
More informationEXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE
OIL AND GAS DO0KET NO. 01-0249550 THE APPLICATION OF REGENCY FS LP UNDER RULE 36 AND RULE 46 TO DISPOSE OF OIL AND WASTE CONTAINING HYDROGEN SULFIDE GAS INTO ITS TILDEN GPI WELL NO. 1, TILDEN, S. (WILCOX
More informationGeneral Accreditation Guidance. User checks and maintenance of laboratory balances
General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in
More informationGhost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager
Ghost Peaks: How to Fix a Haunting Problem Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager Outline of Topics What is a ghost peak? How to identify ghost peaks and their source How to correct
More informationTHE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM
THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM What is pressure drop in a compressed air utility? Pressure drop is a term used to characterize the reduction in air
More informationEAS Basic Soil Gas Sampler
EAS Basic Soil Gas Sampler Please Read The Following Important Information before Starting The EAS Basic Soil Gas Sampler has the traditional design where a pump or evacuated canister can be to purge the
More informationTECH TIPS: ROPE DEFECTS
Hoist Ropes: Why must they be inspected? A hoist rope is not made to last forever. This is a useful fact, as the kinds of wear that appear on a rope can indicate areas of problems within an installation
More informationAPPENDIX A1 - Drilling and completion work programme
APPENDIX A1 - Drilling and completion work programme Information about the well and drilling To the extent possible, the international system of units (SI) should be adhered to, and the drilling programme
More informationADVANCES IN GAS DRAINAGE & GAS MANAGEMENT WITHIN AAMC - RUSSELL PACKHAM. Gas and Coal Outburst Committee Seminar, Wollongong, 23 rd November 2011.
ADVANCES IN GAS DRAINAGE & GAS MANAGEMENT WITHIN AAMC - RUSSELL PACKHAM Gas and Coal Outburst Committee Seminar, Wollongong, 23 rd November 2011. RICH GAS MANAGEMENT Overview Grasstree Moranbah North Grosvenor
More informationresearch bulletin C L : AIRE
C L : AIRE RB 1 (February 211) CL:AIRE s describe specific, practical aspects of research which have direct application to the characterisation, monitoring or remediation of contaminated soil or groundwater.
More informationEnbridge Pipelines Inc. PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT
Enbridge Pipelines Inc. Line 9B Reversal and Line 9 Capacity Expansion Project Appendix A to Updated Pipeline Engineering Assessment PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT Table of Contents 1.
More informationGeneral Inspection Guidance for Waste Management Units Requiring Air Emission Controls Under RCRA Air Standard Subpart CC
United States Environmental Protection Agency RCRA Programs Branch Region IV Atlanta, GA CAA/RCRA Air Rules 27 November 2000 General Inspection Guidance for Waste Management Units Requiring Air Emission
More informationInquiry Investigation: Factors Affecting Photosynthesis
Inquiry Investigation: Factors Affecting Photosynthesis Background Photosynthesis fuels ecosystems and replenishes the Earth's atmosphere with oxygen. Like all enzyme-driven reactions, the rate of photosynthesis
More informationGenerating Calibration Gas Standards
Technical Note 1001 Metronics Inc. Generating Calibration Gas Standards with Dynacal Permeation Devices Permeation devices provide an excellent method of producing known gas concentrations in the PPM and
More informationUNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008
UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method
More informationSmart Water Application Technologies (SWAT) TM
Smart Water Application Technologies (SWAT) TM Equipment Functionality Test Protocol Version 2.3 June 2014 SWAT Committee 8280 Willow Oaks Corporate Drive Suite 400 Fairfax, VA 22031 www.irrigation.org
More informationChapter 22 Testing Protocols
This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated
More informationThis test shall be carried out on all vehicles equipped with open type traction batteries.
5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following
More informationEnbridge G & P (East Texas) LP EXAMINER S REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE
OIL AND GAS DOCKET NO. 05-0263914 THE APPLICATION OF ENBRIDGE G & P (EAST TEXAS) LP FOR AUTHORITY PURSUANT TO STATEWIDE RULES 9 AND 36 TO DISPOSE OF OIL AND GAS WASTE CONTAINING HYDROGEN SULFIDE INTO ITS
More informationSUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE
Page 1 of 6 A. PURPOSE AND SCOPE This procedure establishes safe working practices for handling sulfur hexafluoride (SF 6 ) gas and release minimization practices. This document also specifies methods
More informationOverview ASTATT3. Carry out air tightness testing for single dwellings and other small buildings
Overview This standard is for those who carry out air tightness and/or change rate testing of single dwellings and small up to a gross internal volume of 4000m³ inside the thermal line as defined by EN13829
More informationChallenges of gas monitoring and interpretation in underground coal mines following an emergency
University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2012 Challenges of gas monitoring and interpretation in underground coal mines following
More informationDesign Assessment Checklist: Infiltration / Detention Basin
Design Assessment Checklist: Infiltration / Detention Basin Objectives This checklist can be used by the organisation approving the drainage scheme (drainage approving body) to help assess submissions
More informationConfined Space July 2014
Confined Space July 2014 How Are We Doing? LTI s 0 in last 12 months Period Location Oil & Gas Base AFR Oil & Gas Sites AFR Total AFR May 0 0 0 12 Month Rolling 0 2.14 1.35 Statistics presented one month
More informationEuropean Technical Standard Order (ETSO)
Date: 28/11/2008 European Aviation Safety Agency European Technical Standard Order (ETSO) Subject: CREWMEMBER OXYGEN MASK 1 - Applicability This ETSO gives the requirements which the crewmember constant
More informationCAS Guidance (CAS-G-004)
Water Use CAS Guidance (CAS-G-004) Flow Recording and Reporting at Sewage Treatment Works and on the Sewer Network Version: v2 Released: Jan 2017 Copyright and Legal Information Copyright 2017 Scottish
More informationCOAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:
COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS Prepared for: SANDY CREEK SERVICES, LLC P.O. Box 370 Riesel, Texas 76682 Prepared by: SCS ENGINEERS TBPE
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions
More informationMitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!
P.S.I.G. Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training! Last Unfortunately is When It Goes Wrong! The Failure! The Release! Loss of Product or Production
More informationTechnical Support Note
Title: Air Dilution Correction using O2 and CO2 TSN Number: 17 File:S:\Bridge_Analyzers\Customer_Service_Documentation\Technical_Support_Notes\ 17 Air Dilution correction using O2 and CO2.docx Created
More informationGASEOUS EXCHANGE IN PLANTS & ANIMALS 30 JULY 2014
GASEOUS EXCHANGE IN PLANTS & ANIMALS 30 JULY 2014 In this lesson, we: Lesson Description Define gaseous exchange o o Look at the requirements for efficient gaseous exchange Study gaseous exchange in various
More informationExploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans.
Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans. The Research Question In this investigation I will be considering the following general research question: Does increased
More informationNZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site
Page 1 of 8 Title Manage the mine ventilation system at an extractive site Level 7 Credits 30 Purpose This unit standard covers the development and management of the operation and maintenance of a mine
More informationGuidance on room integrity testing and its interpretation
Guidance Note Guidance on room integrity testing and its interpretation Guidance on room integrity testing and its interpretation 1. SCOPE... 6 2. INTRODUCTION AND BACKGROUND... 6 2.1. DEVELOPMENT OF INTEGRITY
More informationRULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS
RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER 0400-52-06 DRILLING WELLS TABLE OF CONTENTS 0400-52-06-.01 Drilling Equipment 0400-52-06-.03 Casingheads 0400-52-06-.02 Blowout Prevention
More informationCOAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:
COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS Prepared for: SANDY CREEK SERVICES, LLC P.O. Box 370 Riesel, Texas 76682 Prepared by: SCS ENGINEERS TBPE
More informationLegal Requirements Planning and carrying out drilling work
Health and and Safety Executive Geotechnica 13 th July 2017 Warwick Legal Requirements Planning and carrying out drilling work John Underwood HSE Construction Sector Safety Team john.underwood@hse.gov.uk
More information