THERMO-HYDRAULIC ANALYSIS OF FORCED FLOW HELIUM COOLED CRYOPANELS OF CRYOPUMP USING VENECIA CODE

Size: px
Start display at page:

Download "THERMO-HYDRAULIC ANALYSIS OF FORCED FLOW HELIUM COOLED CRYOPANELS OF CRYOPUMP USING VENECIA CODE"

Transcription

1 SAMIRAN SHANTI MUKHERJEE et al. THERMO-HYDRAULIC ANALYSIS OF FORCED FLOW HELIUM COOLED CRYOPANELS OF CRYOPUMP USING VENECIA CODE SAMIRAN SHANTI MUKHERJEE, VISHAL GUPTA, RANJANA GANGRADEY, JYOTI SHANKAR MISHRA, PRATIK NAYAK, PARESH PANCHAL, SUBHADIP DAS, JYOTI AGARWAL Institute for Plasma Research Gandhinagar, India Abstract Cryoadsorption cryopump with large pumping speeds application has been developed at the Institute for Plasma Research (IPR). These pumps are cooled with liquid helium for cryopumping panels below temperature 5K to adsorb hydrogen and helium gases and with gaseous helium for thermal shields at around 80K during fusion reactor relevant future applications. These panels are coated with activated carbon as sorbent. Sorbent with micro-pores adsorbs gases and the pores get saturated after certain duration of pumping operation. During regeneration by increasing the panel temperature adsorbed gases get removed. A cycle of operation is thus followed comprising, cool down from 80K to ~K and warm up from ~K to 80K during the normal operation cycle of the cryopump. Cryopanels and shielding panels are mostly hydoformed quilted stainless steel panels with sheet thickness of.5mm. Hydroformed panel of size 000mm (l) x 200mm (w) with the 3mm thickness connected by inlet and outlet tubes are used as K cryopanel. Thermohydraulic analyses are carried out in Venecia software developed by Alphysica for the 2 Panel cryopump for different operational schemes. To investigate the necessary mass flow rates and cool down time, optimized selection of the cryopanel arrangements, flow paths and manifolds is required. Results of cool-down time, mass flow requirement and temperature profile is presented for different cooling and regeneration scheme.. INTRODUCTION For large pulse duration plasma machines and future coming up experimental fusion reactor like ITER, pumping of enormous scale gas loads is a demanding requirement []. Among all the other auxiliary subsystems, large pumping capacity vacuum subsystem will be one of the key requirements for successful steady operation of the fusion machines. The pumping requirements in ITER like machines is huge (greater than 50 cubic meters per second) and are required for torus, cryostat and neutral beam injectors [2]. The gases to be pumped are mainly helium and various isotopes of hydrogen. After a rigorous study at KIT Germany, for more than 0 years, cryopump design for ITER scenario was completed [3] and the first delivery of cryopump to ITER site, Cadarache FE was completed during August 207[]. Institute for Plasma Research (IPR) is working for the development of the technologies in national level relevant to nuclear fusion that will lead us to build fusion power reactors in near future [5][6]. Aiming that, prototype development of various auxiliary technologies is on-going at IPR. In recent years, a prototype Cryoadsorption cryopump with large pumping speeds application has been successfully tested at the IPR [7]. These pumps are designed to adsorb hydrogen isotopes and exhaust helium gases in order to maintain high vacuum conditions for subsequent plasma confinement. The pump mainly consists of ) thermal shield and baffles, cooled down to 80K temperature. 2) Activated carbon coated hydro formed panels connected in series and/or parallel cooled down at around.5k temperature. The porous activated carbon materials provide enormous pumping speed when cooled to sufficiently low temperatures. On regeneration of such cryopanels, the clogged gases are removed and pores become fresh to hold yet another cycle of gas load. In the process the panel undergoes thermal cycling comprising cool down to.5k by liquid helium and warm up by gaseous helium up to 80K. Preestimating the optimum cool down and warm up time scales are important to study regeneration stages and to estimate the pumping time scales. Design and analysis for 2-panel cryopump with expecting pumping speed greater than 50,000 litres per second is on-going at IPR. This cryopump will be tested stand-alone integrated to 80K gaseous helium supply plant and liquid helium plant to demonstrate the technical feasibility and indigenous capability. 2. GEOMETRICAL ARRANGEMENTS AND THE COOLING SCHEMES As an overview, Fig. shown the stand alone test scheme of the cryopump integrated with K liquid helium plant supply system and 80K gaseous helium supply system. Super critical helium at.k and bar pressure will be used to cool down the cryopanel assembly from 80K to less than 5K temperatures, whereas the 80K gaseous helium supply system will be used to warm up the panel till 80K for fast regeneration and cool down

2 FIP/P3-50 the panel assembly from 300K to 80K temperatures. On the other hand, all the hydroformed thermal shields will be kept at constant temperature of 80-85K to provide radiation shielding to the K components. The internal distribution of the 80K system is not shown in the Fig.. At actual it will have a distribution line, through which 80K gaseous helium will be supplied to the K system as well as thermal shields. Present study will help to understand the mass flow requirement for the K panel assembly and the required cool down and 80K warm up time. The 80K plant available at IPR is capable of delivering gm/s variable mass flow rate at 80K and delivers at 5 bar pressure. FIG.. Lay-out diagram of the cryopump assembly with the K liquid helium and 80K gaseous helium supply system. A B C FIG. 2. A. Flow diagram of the cooling scheme for cryopump panel assembly showing different inlet supply arrangements B. Cryopanel CAD model C.3D CAD model of the cryopanel assembly of 2 panels with flow connectors and headers For estimating the cool down and warm up time for the 2 panel cryopanel assembly thermohydraulic analysis is being carried out in Venecia Code developed by Alphysica. 2 panels will be arranged in four parallel channel manifolds and each channel will have 6 cryopanels in series as shown in Fig.2A. Each individual panel will

3 SAMIRAN SHANTI MUKHERJEE et al. have four parallel channels through which fluid will be passed through. Each cryopanel is 000 mm in length and 200 mm in width with hydroformed sheet thickness of.5 mm. The maximum bulge height is 9mm. These hydroformed cryopanels were developed indigenously [8] and technology has been transferred to the industry for its wide applications not only in nuclear fusion related technology but also for the space research and other application. These cryopanels and its prototypes were used as small scale miniature cryopump[9] to the larger scale applications. 3. MODELING AND THEORITICAL REFERENCES The present work has been carried out using the software package VENECIA which is the advanced version of the code Vincenta. With an extensive research and more than 0 years of experience in thermal hydraulic simulations for large magnet systems (ITER, KSTAR, JT-60) this code was developed and was validated [0]. For relatively complex geometries with efficient heat transfer requirements, liquid helium is not commonly used. In those cases a forced flow helium flow with temperature slightly higher than the normal boiling point.2k and pressure above the atmospheric but within the critical point is used. In this particular range, the Gruneisen parameter, isentropic compressibility, and velocity of sound are the three thermodynamic parameters, which are weakly non-catalytic near the critical point, and are used to describe fluid flow processes []. To define the simulation input, basic mathematical models is used for the cryogenic system like magnet system, cryopump system, cryo-distribution line etc. Defined mathematical models are described with set of algebraic, differential equations or in partial derivatives. The main function of the simulation is to solve those set of equations of continuity for D compressible fluid flow involving mass, momentum and energy conservation [2]. Transient parameters of compressible helium flow inside the channel simulated in this particular tool. Mass, momentum and energy conservation terms and material properties are linked under thermo-hydraulic conditions with different flows and solid materials. When the forced flow liquid helium is considered in the problem, the change in temperature, density and other fluid flow parameters are highly non-linear with respect to the time and space making the solution to fluid equations highly complex. Runga kutta th order numerical method is used for the thermal hydraulic analysis of two phase helium flow to know transient behaviour of the fluid. For carrying out the simulation a grid of the special distribution in D and time fraction is defined for the problem to solve in that particular space-time for zooming in the transients. Initial set of fluid parameters are then fed along with the different geometrical shape of the hydraulic structures. Upon solving the equations, simulation results are obtained graphically and numerical output of variations in thermal hydraulic parameters are obtained for every defined space-time step. Basic understanding as discussed above, numerical models set of equations used and their definitions are described by Nickolay A. Shatil [3] and how to define the numerical models for the simulations are elaborated in the Venecia user s guide version [2]. Simulations are carried out for different operation modes in order to get the full cryopump operation cycles 300K to 80K Cool Down: In this process 80K gaseous helium is supplied to the cryopanel assembly. During this mode, valve V2 (see Fig.2.A) is kept open and other fluid supply valve V and V3 is kept closed. 80K gaseous helium passes through the cryopump and cools down the system close to the 80K temperatures. 80K to.k Cool Down: In this process.k helium is supplied to the cryopanel assembly. During this mode, valve V3 (see Fig.2.A) is kept open and other fluid supply valve V and V2 is kept closed..k forced flow super critical helium passes through the cryopump and cools down the system below 5K temperatures. During this process the cryopump will be in operational mode and constant flow will be maintained during the operation time..k to 80K warm-up: In this process 80 gaseous helium is supplied to the cryopanel assembly. During this mode, valve V2 (see Fig.2.A) is kept open and other fluid supply valve V and V3 is kept closed. 80K forced flow gaseous helium passes through the cryopump and warms up the system close to 80K temperatures. During the sequential operation of cryopump 80K to.k cool-down and.k to 80K warm up is carried out for operation and 80K regeneration. 80K to 300K warm-up: In this process 300K gaseous helium is supplied to the cryopanel assembly. During this mode, valve V (see Fig.2.A) is kept open and other fluid supply valve V2 and V3 is kept closed. 300K gaseous helium passes through the cryopump and warms up the system close to 300K temperatures. This process is required whenever complete regeneration is necessary, in order to release the moisture, nitrogen and other residual gases. 3

4 FIP/P3-50 During the operation of the each mode, previous operation state is considered as initial boundary conditions. The weight of the cryopanel assembly is more than 0kg therefore required mass flow rate is reasonably high. Compared to the enthalpy of the overall system, the radiation heat load and the residual gas convection heat load component are negligible, therefore not considered for simulation. In the present simulation, required mass flow rate and time to cool down or warm up the system, are the major deliverable to attain the required operation conditions in different modes.. SOLUTION RESULTS During the modelling of the simulation, all the hydroformed cryopanels (as shown in Fig.2.B) are considered as straight channels. Each cryopanel have parallel channels of same hydraulic dimension. The main supply of fluid initially divides into parallel sections in the manifolds, thereafter supply fluid is fed to the panel section having 6 panels in series. A total of 2 panels were taken as the cryopump assembly as shown in Fig.2.C. As the present simulation aims the thermohydraulic analysis of the panel assembly, therefore transfer line section is not considered. It is assumed that, there will be bypass valve connected before that delivery of the fluid to the system. Hence, both the main fluid inlet and outlet pipe is assumed to be m in length. Details of the geometrical arrangements are put in table.. TABLE.VALUES OF GEOMETRICAL PARAMETERS AND POSITION IN -D Parts Crosssection Area of Conductors ( ) Perimeter of channels (m) Cross-section Area of channels ( ) Length (m) No. of flow paths/parallel channels Linear Distance [x] (m) Inlet 0.26E E-3 3.0E-6 Flow divider/ E E-3 3.0E-6 manifold 2-Panels 50.0E E E E E E E E E E E E (panel- ) 3.-. (panel-2) (panel-3) (panel-) (panel-5) (panel-6) Flow collector 0.26E E-3 3.0E Outlet 0.26E E-3 3.0E K to 80K Cool Down 80K gaseous helium at 5 bar is supplied to the pump through the supply valve V2. Supply of gaseous helium cools the supply transfer line, then the manifolds and then consecutively each individual panel. In the Fig.3.A, mass flow rate variation over the -dimnsional distance is shown. A maximum mass flow of 0gm/s is observed within the differential pressure of 500 mbar across the system. During the event how the temperature variation is takes place is shown in Fig.3.B. It shows a required cool-down time of 90 seconds. Each panel will have approximately 5kg of weight; therefore, sensible cooling of panel is slow compared to the inlet and outlet connection pipes connected in each end of the panels. As the effective mass flow is high for the inlet and outlet connections of the panels, there is a sharp fall of temperature in transient mode (see Fig.3.B.) in locations where panel inlet and outlet connections are put. During the transient flow of the 80K gaseous helium, the velocity in the panel varies from 3 to 9 m/s.

5 SAMIRAN SHANTI MUKHERJEE et al. FIG. 3. A. Variations of mass flow rate across the linear distances during K cool down, B. Temperature profile at different location of the cryopumps during the cool down of cryopump from K.2. 80K to K Cool Down During this event, forced flow.k super critical helium at bar pressure is supplied, considering the initial state of the panel assembly to be at 80K temperature. When, the geometry gets cooled, mass flow rate increases and reaches upto 00gm/s (as shown in the Fig..A). This is observed due to the pressure regulation at the output of the return line which was kept at 3.65 bar. This mass flow can be regulated either by outlet pressure regulation or optimizing the supply pressure to the cryopump. With a maximum flow rate of 00gm/s, all the panels gets cooled down to ~.5K temperature within 30 seconds. As shown in the Fig..B, each panel is gradually cools down and takes approximately 5 seconds. FIG.. A. Variations of mass flow rate across the linear distances during 80-K cool down, B. Temperature profile at different location of the cryopumps during the cool down of cryopump from 80-. K.3. K to 80K warming up During this event it is assumed that, the flow channels are filled with helium at. K and bar pressure and 80K gaseous helium pushes out the helium and starts warming up the cryopump system. As shown in Fig.5 maximum mass flow rate is 0gm/s and gets uniform at 0gm/s. Initial mass flow rate is slightly increased due to the flushing out of previously occupied helium and at the same time all the channels were cooled during the initial state, this leads to the increase in mass flow rate. 5

6 FIP/P3-50 FIG.5. Variations of mass flow rate across the linear distances during -80 K warm up/regeneration As seen in the Fig 6, panels initially warms up rapidly up to 0-50K within 0 second of time and after that it warms up slowly up to the ~80K temperatures. Here also all the inlet and outlet connection pipes at the end of each panels shows slightly higher temperature compares to the panel sections due to the increase in velocity and effective mass flow rates at those sections. During this event velocity is very less approximately.m/s at each channel of the panels whereas at the connection pipes it reaches up to m/s. To warm up till ~80K temperature, the cryopump takes around 70 seconds. FIG. 6. Temperature profile at different location of the cryopumps during the warming up of cryopump from -80 K K warming up The cryopump usually operates at to 5K temperatures to pump helium and hydrogen isotopes effectively. After a certain pumping duration these cryopumps are regenerated and the duration of operation is decided based on the hydrogen safety limit and the gas load condition during the plasma operation. These details are not discussed here as the present system is stand-alone experimental test facility. After each operation cycles there is regeneration cycle and during this event all the trapped gases are removed. During a reactor relevant condition most of gas composition will be helium and hydrogen isotope. Therefore, 80K regeneration will be sufficient. During the cryopump operation there will always be a chance for reduction of the efficiency of cryopumping due to the water vapour, nitrogen and other gas entrapment in the charcoal beds. Those gases will fill up the

7 SAMIRAN SHANTI MUKHERJEE et al. charcoal pores, therefore effectively reduces the pumping efficiency. During such an event, once should goahead for rapid regeneration up to the 300K or higher instead of natural warm up of the system. Considering this scenario, warm up to 300 K is being studied. Here, warm room temperature helium at a pressure 5 bar is supplied to the system which effectively delivers up to 80gm/s mass flow to the system as shown in Fig.7. FIG. 7. Variations of mass flow rate across the linear distances during K warm up As seen the Fig 8, with the mass flow of approximately 55 to 75 gm/s all the panels can be warmed up in 280 second time. FIG.8. Temperature profile at different location of the cryopumps during the warm up of cryopump from K 5. CONCLUSION In the present work, complete operational cycle of the cryopump has been analysed. Based on the cryogen supply system availability, major flow conditions are put in the simulation and the cool down and warm up details are found for the operation of the cryopump. The results shows required cool down for 300K to 80K is 90 seconds and for 80K to. K cool down it is 30 second for helium mass flow of 0 gm/s and 00 gm/s (max.). Whereas for the warm up or regeneration for.k to 80K it takes 70 seconds and for 80K to 300K warm up it takes 280 seconds when the mass flow is considered 0 gm/s and ~75 gm/s respectively. During the analysis pressure domain are regulated by applying a pressure control valve before the outlet collector. Based on 7

8 FIP/P3-50 the studies carried out all the cryogen supply system will be modulated to offer the best suitable flow conditions. Actual operational conditions will be monitored during the experimental testing of the cryopump system. ACKNOWLEDGEMENTS The author s would like to thank Department of Atomic Energy, Govt. of India for supporting this work. For carrying out the simulation Venecia software package is used which is supplied by M/s Alphysica, St. Petersburg, Russia. Authors would like to thank Ms. Reena Sayani for her contribution to the initial software installation and benchmark analysis. REFERENCES [] V.KALININE et al., Cryogenic Subsystem to Provide for Nominal Operation and Fast regeneration of the ITER Primary Cryosorption Vacuum Pumps, AIP Conf. Proc., vol. 8, no. 70, 200. [2] C. DAY. et Al., Validated Design of the ITER Main Vacuum Pumping Systems, IAEA fusion energy conference, 200, IT/P3 7,. [3] M. DREMEL et al., The new build to print design of the ITER Torus Cryopump, Fusion Eng. Des., vol. 88, no. 6 8, pp , 203. [] Press Releases from FE, Europe delivers to ITER the first cryopump, 29th August 207, weblink: [5] S. DESHPANDE AND P. KAW, Fusion research programme in India, Sadhana, vol. 38, October, pp , 203. [6] R. SRINIVASAN et al. Role of Fusion Energy in India, Journal of Plasma Fusion Res. SERIES. vol. 9, pp , 200. [7] R. GANGRADEY et al., Progress towards achieving large pumping speed for exhaust from fusion grade machines, IAEA fusion energy conference, 206, FIP/P7-2. [8] R.GANGRADEY et al. Design and indigenous development and fabrication of cryopanels for cryopump applications IEEE/NPSS 2th Symposium on Fusion Engineering 20, SP-0. [9] R. GANGRADEY, Pumping speed offered by activated carbon at liquid helium temperatures by sorbents adhered to indigenously developed hydroformed cryopanel. IOP Conf. Series: Materials Science and Engineering 0 (205) 020 doi:0.088/ x/0//020 [0] VENECIA : Venecia software package for thermal hydraulic analysis of forced flow cooled superconducting equipment and their primary cryogenic subsystems Introduction, 208. [] V. ARP, Thermodynamics of single-phase one-dimensional fluid flow Cryogenics, P , May 975. [2] VENECIA User s Guide. by M/s Aplphysica, St. Petersburg, Russia [3] NICKOLAY A. SHATIL Quench Simulation of VLHC Transmission Line Magnet. Report No: TD-0-025, St.- Petersburg, Russia, February 999

Cable in Conduit Conductor (CICC) quench modelling

Cable in Conduit Conductor (CICC) quench modelling DEMO SAMPLE Cable in Conduit Conductor (CICC) quench modelling This demo gives an example of quench simulation for a Central Solenoid (CS). CS is divided into geometrically identical sections (see Fig.

More information

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 INAOE. Tonantzintla, Mexico. 2010-06-23. June 23 rd, 2010 Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 Joel Molina INAOE Microelectronics Group jmolina@inaoep.mx 1 Vacuum

More information

Specifications of Cryogenic vacuum jacketed valves

Specifications of Cryogenic vacuum jacketed valves TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. SECTION - C Technical Specifications for Supply of Cryogenic Vacuum ed Control Valves Specifications of Cryogenic vacuum jacketed valves Contents 1 INTRODUCTION

More information

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler C. Becnel, J. Lagrone, and K. Kelly Mezzo Technologies Baton Rouge, LA USA 70806 ABSTRACT The Missile Defense Agency has supported a research

More information

First Experimental Data of the Cryogenic Safety Test Facility PICARD

First Experimental Data of the Cryogenic Safety Test Facility PICARD First Experimental Data of the Cryogenic Safety Test Facility PICARD C. Heidt, A. Henriques, M. Stamm and S. Grohmann 26 th International Cryogenic Engineering Conference 2016 in New Delhi, India KIT,

More information

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

International Journal of Technical Research and Applications e-issn: ,  Volume 4, Issue 3 (May-June, 2016), PP. DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008

More information

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd. Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV

More information

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute (JAERI),

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER P P P International Journal of Scientific Engineering and Applied Science (IJSEAS) - Volume-1, Issue-6, September 2015 AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON

More information

Overview of Earlier Lecture

Overview of Earlier Lecture 4 1 Overview of Earlier Lecture Hydrogen Helium Phase Diagram of Helium Super fluid Helium 2 Outline of the Lecture Uses of Helium 4 Thermomechanical, Mechanocaloric, Fountain, Rollin Film Effects. Sound

More information

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS T. Gélain, C. Prévost Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Saclay, France Abstract In order to better understand the risks due

More information

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE - 247 - AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE J D Castro a, C W Pope a and R D Matthews b a Mott MacDonald Ltd, St Anne House,

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube Y Raja Kumar ¹, Dr.P Usha sri ² PG Student¹, Associate professor² Department of Mechanical Engineering, University College of Engineering

More information

Development of a high vacuum sample preparation system for helium mass spectrometer

Development of a high vacuum sample preparation system for helium mass spectrometer Journal of Physics: Conference Series Development of a high vacuum sample preparation system for helium mass spectrometer To cite this article: P Kumar et al 2012 J. Phys.: Conf. Ser. 390 012056 View the

More information

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics Large Hadron Collider Project LHC Project Report 388 EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC

More information

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD http:// OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD Anand Kumar S malipatil 1, Anantharaja M.H 2 1,2 Department of Thermal Power Engineering, VTU-RO Gulbarga,

More information

Thermodynamic Study of Compartment Venting

Thermodynamic Study of Compartment Venting Thermodynamic Study of Compartment Venting Francisco Manuel Bargado Benavente francisco.benavente@tecnico.ulisboa.pt Instituto Superior Técnico, Universidade de Lisboa Lisbon, Portugal Abstract Compartment

More information

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak Journal of Physics: Conference Series Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak To cite this article: F S Pathan et al 2008 J. Phys.:

More information

A Brief Introduction to Helium Liquefaction At ITER

A Brief Introduction to Helium Liquefaction At ITER ITER Cryogenic System LHe PLANTS A Brief Introduction to Helium Liquefaction At ITER ITER Organization PLANT ENGINEERING DIVISION CRYOGENIC SECTION LHe PLANTS TRO: Eric FAUVE A Brief Introduction to to

More information

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator Yong-Ju Hong 1, Seong-Je Park 1, and Young-Don Choi 2 1 Korea Institute of Machinery & Materials, Daejeon,

More information

PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM

PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM A.K.VERMA Institute for Plasma

More information

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses Simulator For Performance Prediction Of Reciprocating Considering Various Losses Aditya S. Bawane 1, Dr. V.K. Bhojwani 2, Mitali B. Deshmukh 3 1 (Mechanical Engineering Department, JSCOE, S.P. Pune University,

More information

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components 1 /7-12 Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel IER and DEMO components M. Ionescu-Bujor, B.E. Ghidersa, G. Janeschitz, X. Jin orschungszentrum Karlsruhe, Germany e-mail:

More information

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler M. Xu, H. Takayama and K. Nakano Sumitomo Heavy Industries, Ltd. Nishi-tokyo-city, Tokyo, Japan 188-8585 ABSTRACT Sumitomo Heavy Industries

More information

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. Introduction of Vacuum Science & Technology Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. 1 What is a vacuum? 760 mm Hg Vacuum ATM A vacuum is defined as less than

More information

Loss of Vacuum Experiments on a Superfluid Helium Vessel

Loss of Vacuum Experiments on a Superfluid Helium Vessel 1 Loss of Vacuum Experiments on a Superfluid Helium Vessel Stephen M. Harrison 1 Abstract The Alpha Magnetic Spectrometer (AMS) is a particle physics experiment for use on the International Space Station

More information

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Technical Specifications of Hydrogen Isotope Handling and Recovery System SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I

More information

NUMERICAL ANALYSIS OF SINGLE STAGE PULSE TUBE REFRIGERATOR

NUMERICAL ANALYSIS OF SINGLE STAGE PULSE TUBE REFRIGERATOR NUMERICAL ANALYSIS OF SINGLE STAGE PULSE TUBE REFRIGERATOR Preethi.M.V #, Arunkumar K N #,Kasthuriregan S #2 and Vasudevan K #2. # Vidya Vardhakka College of engineering, Mysuru-570002. m.v.preethi35@gmail.com

More information

Characterizers for control loops

Characterizers for control loops Characterizers for control loops By: F. G. Shinskey (May 1999) Introduction Commercial controllers such as the PID series (proportional, integral, derivative, and their combinations) are linear devices

More information

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006 ZIN Technologies PHi Engineering Support PHi-RPT-0002 CFD Analysis of Large Bubble Mixing Proprietary ZIN Technologies, Inc. For nearly five decades, ZIN Technologies has provided integrated products and

More information

Cryogenics The Basics. Lesson 2 D. Kashy

Cryogenics The Basics. Lesson 2 D. Kashy Cryogenics The Basics Lesson 2 D. Kashy Lecture 1 Review Lesson 1 - Objectives Looked at common liquids and gases to get a feeling for their properties Looked at Nitrogen and Helium Discussed Pressure

More information

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR PROCEEDINGS OF THE YEREVAN STATE UNIVERSITY Physical and Mathematical Sciences 216, 2, p. 57 62 P h y s i c s SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 44/27

More information

Transient Analyses In Relief Systems

Transient Analyses In Relief Systems Transient Analyses In Relief Systems Dirk Deboer, Brady Haneman and Quoc-Khanh Tran Kaiser Engineers Pty Ltd ABSTRACT Analyses of pressure relief systems are concerned with transient process disturbances

More information

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator Y. J. Hong, S.J. Park, J. Ko, H.B. Kim Korea Institute of Machinery & Materials Daejeon, 305-343, Korea ABSTRACT Miniature

More information

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator T. Huang 1, A. Caughley 2, R. Young 2 and V. Chamritski 1 1 HTS-110 Ltd Lower Hutt, New Zealand 2 Industrial Research Ltd

More information

HTR Systems and Components

HTR Systems and Components IAEA Course on HTR Technology Beijing, 22-26.October 2012 HTR Systems and Components Dr. Gerd Brinkmann Dieter Vanvor AREVA NP GMBH Henry-Dunant-Strasse 50 91058 Erlangen phone +49 9131 900 96840/95821

More information

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012 Basic Hydraulics Module 4: Flow Control Valves & Pressure Relief Valves PREPARED BY Academic Services January 2012 Applied Technology High Schools, 2011 ATM 1122 Basic Hydraulics Module 4: Flow control

More information

Development of a Miniaturized Pressure Regulation System "mprs"

Development of a Miniaturized Pressure Regulation System mprs Development of a Miniaturized Pressure Regulation System "mprs" IEPC-2015-365 /ISTS-2015-b-365 Presented at Joint Conference of 30th International Symposium on Space Technology and Science 34th International

More information

Study of Mixed Gas Flow Pattern Inside RPC

Study of Mixed Gas Flow Pattern Inside RPC Study of Mixed Gas Flow Pattern Inside RPC S. D. Kalmani a,1, P.V. Verma a, R. P. SHINDE b and P. V. Hunagund c a Dept. of High Energy Physics, Tata Institute of Fundamental Research, Mumbai, India. b

More information

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC)

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC) Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron

More information

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor Volume 118 No. 18 2018, 4241-4252 ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Two-way Fluid Structure Interaction (FSI) Analysis on the Suction

More information

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater Proceedings of the 2 nd World Congress on Mechanical, Chemical, and Material Engineering (MCM'16) Budapest, Hungary August 22 23, 216 Paper No. HTFF 146 DOI:.11159/htff16.146 Visual Observation of Nucleate

More information

SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS

SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS BY ADVANCED ALTITUDE SIMULATION Klaus SCHÄFER Institute of Space Propulsion, German Aerospace Centre (DLR) Lampoldshausen, 74239 Hardthausen, Germany klaus.schaefer@dlr.de

More information

ITER_D_R8752R v.1.1. IDM UID D_R8752R v.1.1

ITER_D_R8752R v.1.1. IDM UID D_R8752R v.1.1 IDM UID D_R8752R v.1.1 Technical Specifications: Supply of Elastomer sealed Ultra High Vacuum Valves for the ITER Project. Technical Specifications: Supply of Elastomer sealed Ultra High Vacuum Valves

More information

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY WHITE PAPER A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY Author(s): Adam Jones and Grant Johnson, Costain Natural Resources First published: GPAE, September 2014 www.costain.com A New Process for

More information

CFD Analysis of Giromill Type Vertical Axis Wind Turbine

CFD Analysis of Giromill Type Vertical Axis Wind Turbine 242 CFD Analysis Giromill Type Vertical Axis Wind Turbine K. Sainath 1, T. Ravi 2, Suresh Akella 3, P. Madhu Sudhan 4 1 Associate Pressor, Department Mechanical Engineering, Sreyas Inst. Engg. & Tech.,

More information

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER 1 SE/P-2 Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute,

More information

The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump

The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump Vinayak Manur 1, Sharanabasappa 2, M. S. Hebbal 3 P.G.Students, Department of Mechanical Engineering, Basaveshwar Engineering College,

More information

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1) Modeling and Field Verification Study of Air Slam Conditions on kalanit Pipeline System By Yiftach Brunner & Sathish Kumar ir valves are integral part of long water transmission mains and are essential

More information

Baffles and Traps Cryotrap

Baffles and Traps Cryotrap Baffles and Traps 362-6 Cryotrap Varian Low-Profile Water-Cooled Baffles combine 100% optical density with high conductance and unusually low overall height. They are especially useful in applications

More information

Flow transients in multiphase pipelines

Flow transients in multiphase pipelines Flow transients in multiphase pipelines David Wiszniewski School of Mechanical Engineering, University of Western Australia Prof. Ole Jørgen Nydal Multiphase Flow Laboratory, Norwegian University of Science

More information

R.Maingi, G.L. Jackson, M.R. Wade,? M.A. Mahdavi, P.K.Mioduszewski,?

R.Maingi, G.L. Jackson, M.R. Wade,? M.A. Mahdavi, P.K.Mioduszewski,? DIVERTOR PARTICLE EXHAUST AND WALL INVENTORY ON DllCD R.Maingi, G.L. Jackson, M.R. Wade,? M.A. Mahdavi, P.K.Mioduszewski,? G. Haas,# M.J. Schaffer, J.T. Hogan,i C.C. Klepperi General Atomics, P.0.Box 85608,

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance Frank Husmeier, Cummins Fuel Systems Presented by Laz Foley, ANSYS Outline Overview Computational Domain and Boundary

More information

Using the CONVAL software for the petrochemical plant control valves checking. Case study

Using the CONVAL software for the petrochemical plant control valves checking. Case study Using the CONVAL software for the petrochemical plant control valves checking. Case study C. Patrascioiu, G. Stamatescu, C. Lazar Abstract In the paper there are presented the researches into field of

More information

ANDRA Benchmark Workshop (Paris-Orly, April 2007)

ANDRA Benchmark Workshop (Paris-Orly, April 2007) ANDRA Benchmark Workshop (Paris-Orly, April 27) Javeri (GRS, Köln, Germany): 2-Dim. Case 1B Code TOUGH2/EOS7 developed by Pruess et al, Lawrence Berkeley National Laboratories, California, USA (199), Since

More information

Research and optimization of intake restrictor for Formula SAE car engine

Research and optimization of intake restrictor for Formula SAE car engine International Journal of Scientific and Research Publications, Volume 4, Issue 4, April 2014 1 Research and optimization of intake restrictor for Formula SAE car engine Pranav Anil Shinde Mechanical Engineering,

More information

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed. GLOSSARY OF TERMS Absolute pressure Total pressure measured from absolute zero i.e. a perfect vacuum. As a practical matter, gauge pressure plus atmospheric pressure. Absolute temperature Temperature measured

More information

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

More information

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00 D R A F T Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13 Version 1.00 October 06, 2010 Operating Procedures for the NPDGamma Liquid Hydrogen Target V1.00 6/10/10 2 Table of Content

More information

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration M. Burak Şamşul ITU AYOC 2014 - Milper Pervane Teknolojileri Company Profile MILPER is established in 2011 as a Research and Development

More information

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program Determination of the Vacuum System for R2R by using a New Pumping Simulation Program AIMCAL WCHC Conference Memphis Oct 10 th, Peter Klingner, Dr. Stefan Lausberg, Dr. Marlis Sydow, Dr. Derek Corcoran

More information

Helium Management of the ESS Target and Monolith Systems

Helium Management of the ESS Target and Monolith Systems Helium Management of the ESS Target and Monolith Systems P. Nilsson, R. Linander, A. Lundgren, C. Kharoua, P. Sabbagh, F. Plewinski, F. Mezei and E. Pitcher European Spallation Source ESS AB, SE-22100

More information

RESIDENTIAL WATER DISTRIBUTION

RESIDENTIAL WATER DISTRIBUTION RESIDENTIAL WATER DISTRIBUTION This case study demonstrates the steady-state simulation of the fresh water (drinking water) reticulation system in a small village. WATER RETICULATION Page1 WATER RETICULATION

More information

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Efficiency Improvement of Rotary Compressor by Improving the Discharge path through

More information

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow A model to examine pigging and inspection of gas networks with multiple pipelines, connections and

More information

Figure 1 Schematic of opposing air bearing concept

Figure 1 Schematic of opposing air bearing concept Theoretical Analysis of Opposing Air Bearing Concept This concept utilizes air bearings to constrain five degrees of freedom of the optic as shown in the figure below. Three pairs of inherently compensated

More information

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India) IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN(e) : 2278-1684, ISSN(p) : 2320 334X, PP : 45-49 www.iosrjournals.org Modeling, Optimization & Manufacturing of Vortex Tube and Application

More information

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR 9. Pompa Vana Kompressör Kongresi 5-7 Mayıs 2016, İstanbul MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR Süleyman Doğan Öner Email: oner@ug.bilkent.edu.tr İbrahim Nasuh Yıldıran Email:

More information

Two-stage pulse tube refrigerator with step displacer as phase shifter

Two-stage pulse tube refrigerator with step displacer as phase shifter IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Two-stage pulse tube refrigerator with step displacer as phase shifter To cite this article: Shaowei Zhu 2015 IOP Conf. Ser.:

More information

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle RESEARCH ARTICLE OPEN ACCESS Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle Shyamshankar.M.B*, Sankar.V** *(Department of Aeronautical

More information

Chapter 8: Cryo-sorption pumps

Chapter 8: Cryo-sorption pumps Chapter 8: Cryo-sorption pumps Cryo-sorption pumps offer a clean, quiet, safe, vibration free and inexpensive way to rough pump a vacuum system. They are often used on vacuum systems that are sensitive

More information

Procedure of Xenon Transfer

Procedure of Xenon Transfer Procedure of Xenon Transfer Feng Zhou,MIT CC: Martina Green February 28, 2005 In this write up, we discuss the procedure on how to transfer xenon to a designed gas storage vessel that supplies xenon to

More information

Investigation of the Early Inflation Characteristics of a Complex Folded Knee Airbag with the New Corpuscular Method in LS-DYNA

Investigation of the Early Inflation Characteristics of a Complex Folded Knee Airbag with the New Corpuscular Method in LS-DYNA 6. LS-DYNA Anwenderforum, Frankenthal 2007 Passive Sicherheit III Investigation of the Early Inflation Characteristics of a Complex Folded Knee Airbag with the New Corpuscular Method in LS-DYNA M. Freisinger

More information

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c Applied Mechanics and Materials Online: 2013-06-13 ISSN: 1662-7482, Vols. 321-324, pp 299-304 doi:10.4028/www.scientific.net/amm.321-324.299 2013 Trans Tech Publications, Switzerland Study on the Influencing

More information

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System JOURNAL ARTICLES BY FLUENT SOFTWARE USERS JA187 Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System Computer simulation has helped NATCO engineers make dramatic improvements

More information

Vacuum Simulations of the KATRIN Experiment

Vacuum Simulations of the KATRIN Experiment Vacuum Simulations of the KATRIN Experiment Marcel Krause (KATRIN collaboration) 31.03.2014 KIT University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association www.kit.edu

More information

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473 DUE: May 23 ASSIGNMENT 2 CHE 3473 #Problem 1: 3.3 #Problem 2: 3.4 #Problem 3: 3.5 #Problem 4: 3.6 #Problem 5: 3.7 #Problem 6: 3.8 #Problem 7: 3.11 #Problem 8: 3.15 #Problem 9: 3.22 #Problem 10: 3.32 #Problem

More information

PRad Target. Chris Keith JLab Target Group

PRad Target. Chris Keith JLab Target Group PRad Target Chris Keith JLab Target Group Target Overview & Components Target Software Hazard Analysis and Mitigation Target Status, Performance& Remaining Work Installation Schedule Nov. 12, 2015 PRad

More information

An Investigation of Liquid Injection in Refrigeration Screw Compressors

An Investigation of Liquid Injection in Refrigeration Screw Compressors An Investigation of Liquid Injection in Refrigeration Screw Compressors Nikola Stosic, Ahmed Kovacevic and Ian K. Smith Centre for Positive Displacement Compressor Technology, City University, London EC1V

More information

CFD Modelling of LPG dispersion

CFD Modelling of LPG dispersion CHAM Limited Pioneering CFD Software for Education & Industry CFD Modelling of LPG dispersion Demonstration example The following describes the numerical analysis of the dispersion of gas release from

More information

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes Water Technologies & Solutions technical paper maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes Authors: W.E. Haas, SUEZ, J. Helmrich, Florida Power and Light and J.E.

More information

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1 OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL Rehan Yousaf 1, Oliver Scherer 1 1 Pöyry Infra Ltd, Zürich, Switzerland ABSTRACT Gotthard Base Tunnel with its 57 km

More information

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473 DUE: May 21 ASSIGNMENT 2 CHE 3473 #Problem 1 Read Chapter 3. ALL OF IT. Time yourself and report the time. #Problem 2: 3.2 #Problem 3: 3.3 #Problem 4: 3.5 #Problem 5: 3.6 #Problem 6: 3.7 #Problem 7: 3.8

More information

Comparison of Methods and Devices for High Pressure Vessel Passivation B. Zitouni (1), L. Denies (1),M. Peukert (1)

Comparison of Methods and Devices for High Pressure Vessel Passivation B. Zitouni (1), L. Denies (1),M. Peukert (1) SPC2016_ 3124678 Comparison of Methods and Devices for High Pressure Vessel Passivation B. Zitouni (1), L. Denies (1),M. Peukert (1) (1) OHB System AG, Universitätsallee 27-29, 28359 Bremen, Germany Email:

More information

NUMERICAL INVESTIGATION ON WATER DISCHARGE CAPABILITY OF SLUICE CAISSON OF TIDAL POWER PLANT

NUMERICAL INVESTIGATION ON WATER DISCHARGE CAPABILITY OF SLUICE CAISSON OF TIDAL POWER PLANT Proceedings of the Sixth International Conference on Asian and Pacific Coasts (APAC ) December 4 6,, Hong Kong, China NUMERICAL INVESTIGATION ON WATER DISCHARGE CAPABILITY OF SLUICE CAISSON OF TIDAL POWER

More information

Laboratory studies of water column separation

Laboratory studies of water column separation IOP Conference Series: Materials Science and Engineering OPEN ACCESS Laboratory studies of water column separation To cite this article: R Autrique and E Rodal 2013 IOP Conf. Ser.: Mater. Sci. Eng. 52

More information

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope. HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope. The solar cell/solar panel shown above depict how a semiconductor can transform solar power into electrical power. Consider the solar panel

More information

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

Linear Compressor Discharge Manifold Design For High Thermal Efficiency Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Linear Compressor Discharge Manifold Design For High Thermal Efficiency Dietmar E.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION Aldin Justin 1, Robin James, Shruti Panicker 2,A.N.Subash,Saravana Kumar 1 Assistant Professor,Karunya University, aldinjustin@karunya.edu

More information

SIMULATION OF ENTRAPMENTS IN LCM PROCESSES

SIMULATION OF ENTRAPMENTS IN LCM PROCESSES Douai, FRANCE - July 6 SIMULATION OF ENTRAPMENTS IN LCM PROCESSES René Arbter, Paolo Ermanni Centre of Structure Technologies ETH Zurich, Leonhardstr. 7, 89 Zurich, Switzerland: rarbter@ethz.ch ABSTRACT:

More information

University of Cincinnati

University of Cincinnati Mapping the Design Space of a Recuperated, Recompression, Precompression Supercritical Carbon Dioxide Power Cycle with Intercooling, Improved Regeneration, and Reheat Andrew Schroder Mark Turner University

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors C. Wang Cryomech, Inc. Syracuse, NY 13211 ABSTRACT This paper introduces the concept of operating a 4 K pulse tube cryocooler

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed

More information