PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM
|
|
- Nathaniel Marsh
- 5 years ago
- Views:
Transcription
1 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM A.K.VERMA Institute for Plasma Research Bhat, Gandhinagar, Gujarat, India B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E. R. KUMAR Institute for Plasma Research Bhat, Gandhinagar, Gujarat, India Abstract Institute for Plasma Research (IPR) is developing an Experimental Helium Cooling Loop (EHCL) as a part of R&D activities in fusion blanket technologies. EHCL is similar to the First Wall Helium Cooling System (FWHCS) of LLCB TBM and in this loop first wall mock ups up to one fourth size of blanket can be tested. The Test Section Module (TSM) of EHCL is designed to remove heat load of ~75 kw. Similar to the FWHCS, EHCL is also high-pressure high-temperature system which produces significant moments in the piping system. This leads to forces and moments in the piping support and equipment nozzles. During the earthquake, a high acceleration acts on the piping system due to this the deflection of pipes may increase the difficulty of loop operation. The paper describes the optimized loop layout of EHCL, methodology and results of pipe stress analysis. EHCL process layout is designed in a limited space (64 m 2 ). All major equipment are installed and connected through the piping and associated valves. For the protection from high energy pipes and other safety reasons, entire process area is protected by strong barricade. The pipe stress analysis is performed for sustained and occasional (earthquake) load combinations of various operating cases envisaged for TSM mock ups. The process piping code ASME B31.3 is referred for pipe stress analysis. The calculated stresses are in acceptable limit. The least available value of stress margin (about 0.29 times the allowable stress) and the corresponding displacement of 9.8 mm (x direction), mm (y direction) and mm (z direction) is observed in heater to TSM line. The obtained reaction and moment force results are needed as an input for the selection of pipe supports and location of supports. This pipe stress analysis results are used in the optimization of EHCL layout and further these inputs would be utilized in final design phase. 1. INTRODUCTION Experimental Helium Cooling Loop (EHCL) is a high-pressure high-temperature closed loop helium gas system [1]. This helium loop is similar to the FWHCS and designed mainly for testing various component mock-ups, which are cooled by high temperature and high pressure helium [2], [3]. The Test Section Module (TSM) mockups will undergo a series of mock-ups qualification tests for design and performance validations. The design of EHCL shall also allow experiments with any other high heat flux helium-cooled components that can be operated within the loop operating range. Major objectives of EHCL are to study the dynamics of the system at different operating conditions (shown in Table 1) and to understand the loop operation & control with associated safety aspects. To take care of pressure fluctuations & loss of inventory, the process loop is also equipped with Pressure and Inventory Control System (PICS). The integrated operation of process loop with PICS, and the understanding of high pressure high temperature piping behavior are essential for final development of EHCL. The paper mainly presents EHCL optimized loop layout and results of pipe stress analysis. 2. SYSTEM DESCRIPTION EHCL is designed for 10 MPa pressure, 450 C temperature and 0.4 kg/s flow rate. The selected size for the connection pipes is DN 50 schedule 80. The maximum operating pressure and temperature are 8 MPa and 400 C respectively [1]. The details of process parameters of EHCL are shown in Table 1. Table 1. Details of process parameters of EHCL Parameters Operating Design Heat load for TSM, kw Temperature at TSM, C Coolant pressure (Helium), MPa Coolant flow rate (Helium), kg/s 0.4, 0.3, 0.2,
2 IAEA-CN-123/45 EHCL loop consists of circulators, heater, recuperator, coolers, compressors, vacuum pumps, control and safety valves, associated piping, and necessary instrumentation and control systems (shown in Fig. 1 & 4). FIG. 1. Process flow diagram of EHCL The P&ID of EHCL is presented in Fig. 1.The loop consists of a hot leg and cold leg, which are connected by recuperator. In the hot leg, TSM and electrical heater are placed, while in the cold leg circulators, dust filters and coolers are placed. In the TSM outlet line, the hot helium temperature is first reduced by the recuperator and then by the cooler. This scheme enables cold leg operation in a temperature range of C and allows the components in the cold leg to operate in a lower temperature environment which simplifies the design of the components. In the cold leg between the recuperator and cooler, helium temperature range is C, while between cooler and circulator discharge line, the temperature range is C. The hot leg is designed to accommodate maximum operating temperature of 400 C and in this portion of loop helium operating temperature range is C. Maintaining low temperature helium to the suction of the helium circulator reduces circulator power requirement. In the loop, two parallel circulators, each of 0.2 kg/s mass flow rate capacity are assembled. Based on the flow rate requirements, one or both the circulators shall be operated. Before the circulators, dust filters are installed to filter the metallic dust of the system. 3. MODELLING AND METHODOLOGY EHCL plant layout is prepared with the help of CATIA V5 modelling tool [4]. 3D layout of EHCL consists of equipment arrangement, pipe routing, supports, cable tray routing, instrumentation arrangement and impulse tube routing. The EHCL lab is constructed in 324 m 2 area, which consists of process loop, control & monitoring room, panel room, storage and maintenance area. The entire process area is fenced with metallic barricade (shown in Fig. 2).
3 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR FIG. 2. EHCL internal arrangement (Process area with protective grid) High temperature pipes are routed from the top part of the facility. The necessary flexible supports and pipe looping are also foreseen in the loop layout. The high temperature lines of EHCL are insulated with CERAWOOL [5]. Insulation covers 20% more volume of the process area, but as estimated, sufficient space is still available for maintenance activities within the process area. For the routine inspection, 0.5 m space margin is available surrounding to all major components. FIG. 3. Access for inspection in EHCL process area The Reliability, Availability, Maintainability and Inspectability (RAMI) aspects are also taken into account during EHCL layout preparation. The inspection and maintenance access is shown in Fig. 3. The optimized layout is simplified for the piping analysis as shown in Fig. 4.The coordinates of EHCL pipes are used to recreate pipe models in CAESAR II software. The data exchange tools are not utilized in order to avoid common problems such as loss of bodies from the assemblies, displacement of original positions, and modification in the graphic information [6]. 3
4 IAEA-CN-123/45 FIG. 4. Simplified EHCL model for piping analysis CAESAR II version 5.30 is used as an analysis tool and ASME B31.3 as a reference code chosen for the analysis of EHCL pipes [7]. The modelled EHCL pipes in CAESAR II software are shown in Fig.5. FIG. 5. Modelling of EHCL pipes in CAESAR II for piping analysis
5 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR The pipe stress analysis is performed for maximum operating conditions of EHCL (refer Table 1). The analysis is performed for sustained and occasional load cases. The sustain loads are due to the pressure, temperature & dead weight while the occasional loads are the additional seismic loads (earthquake loads) on the sustained loads. The input parameters considered for the analysis are illustrated in the Table 2. Table 2. Details of input data for CAESAR II analysis CAESAR Parameters Input values Design Code ASME B31.3 Pipe material SS 316 L Pipe size DN 50 schedule 80 Hot leg Temperature values, C 25,300,350,400 Cold leg Temperature values, C 25, 80, 100 Coolant pressure values, MPa 6.0,8.0,8.5, 10.0 Pipe density, kg /m Fluid density, kg /m CERAWOOL density, kg /m Mill tolerance % 12.5 Thermal Cycles 60,000 Allowable Stress at room temperature, MPa 115 Thermal insulation thickness for hot leg pipes, mm 100 The insulation thickness is calculated for minimum heat loss, maximum efficiency and personnel protection. The insulation thickness is estimated from 3EPlus software [8].The EHCL pipes are designed in compliance with ASME B31.3 code considering various loading conditions (operational state, maintenance and standby) [9]. The load combinations for the analysis of EHCL pipes are shown in Table 3. Table 3. Load combinations of EHCL pipes Load combination Loads Max. events Normal operation (Sustained Load Case) DW+P+T 60,000 Normal operation+ SL (Occasional Load Case) DW+P+T+ Occasional 1 IPR lies in seismic zone III and the process loop is planned to be located at ground floor of EHCL lab at IPR. FRS of Gandhinagar was used to find out the induced stress in the process loop during seismic event. The considered operational states, process parameters and load combinations for the pipe stress analysis are presented in the Table 4. Table 4. Load combinations of process piping as per planned operational states Mock-ups operational States Operational States Process parameters Load Combinations Sustain Loads Occasional Case Operation State (POS) Normal Operation State P= MPa, T= C, F = kg/s L1= DW+P1 (Sustain Case) L2= DW+P2 (Sustain Case) L3= DW+T1+P1 (Operating Case) L4= DW+T2+P2 (Operating Case) L5= L3-L1 (Expansion Case) L6= L4-L2 (Expansion Case) L1+ Occasional L2+ Occasional L3+ Occasional L4+ Occasional L5+ Occasional L6+ Occasional Short Term Standby (STS) Cold Standby State RP = MPa T = C, L1= DW+P1 (Sustain Case) L2= DW+T1+P1 (Operating Case) L1+ Occasional L2+ Occasional 5
6 IAEA-CN-123/45 RF = 0.2 kg/s, Ramping Baking state RP = 1.0 MPa, Temp. = C, RF ~ 10% of F L3= DW+T2+P1 (Operating Case) L4= L2-L1 (Expansion Case) L5= L3-L1 (Expansion Case) L1= DW+P1 (Sustain Case) L2= DW+T1+P1 (Operating Case) L3= L2-L1 (Expansion Case) L3+ Occasional L4+ Occasional L5+ Occasional L1+ Occasional L2+ Occasional L3+ Occasional Long Term Maintenance (LTM) Maintenance state Ambient conditions L1= DW+P1 (Sustain Case) L1+ Occasional DW= Dead weight, P = Pressure, T = Temperature, F = Flow, RP = Reduced Pressure, RF = Reduced Flow. 4. RESULTS The major equipment of EHCL are connected with DN 50 schedule 80 pipes. The pipe material SS316 L is used for connection pipes. The temperature dependent properties of SS316 L are considered for the analysis. The summary of pipe stresses and displacements results during normal operation conditions are shown in Fig. 6. FIG. 6. Pipe stresses and displacements during normal operation condition The summary results of EHCL pipes for sustained, thermal and occasional load cases are presented in Table 5. The stress margin is calculated as margin = (1 - Stress ratio) 100. Whereas; Stress ratio = Calculated Stress / Allowable Stress. Table 5. Summary of results for pipe stresses, displacements and reaction forces Load Cases Available Stress margin % Calculated Stress % Dx, mm Displacements Dy, mm Dz, mm Fx, N Reaction Forces Fy, N Fz, N
7 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR Sustained Load (W+P) 68.5 (1560) 31.5 (1560) (1470) (2460) (2460) 598 (1200) -318 (630) -792 (520) Thermal Load (T) 43.1 (1100) 56.9 (1100) (1680) (1470) (2460) (1380) (630) (970) Occasional Load (W+P+ Occasional) 29.4 (1470) 70.6 (1470) 9.80 (2394) (2390) (2390) 1638 (1200) 1044 (2020) 1024 (520) The highest value of stress about times of allowable stress limit is estimated for Electric heater to TSM line. The maximum displacement of 9.8 mm (x direction), mm (y direction) and mm (z direction) is also observed in the same line. The pipe displacements would be considered during the installation of mechanical supports. The obtained reaction force results would be utilized as an input for the pipe support design. The natural frequency of the integrated EHCL piping system is 4.1 Hz. The dominating natural frequencies in X, Y & Z directions are mentioned in the Table 6. Table 6. Dominating natural frequencies and mass participation factor in X, Y & Z directions Directions Natural Frequency, Hz Mass Participation factor X Y Z The parameters used for the EHCL pipe stress analysis are the maximum allowable temperature and pressure. EHCL piping qualifies to meet the code stress criteria as per the process piping code paragraphs for sustained loads, for occasional loads and for thermal expansion loads for all static and dynamic load conditions. 5. CONCLUSIONS The 3D loop layout of EHCL is modelled in CATIA V5 software. The layout also addresses clash and RAMI aspects. The piping network is used for pipe stress analysis using CAESAR II version 5.30 in accordance with process piping code ASME B31.3. In contemplation of high temperature facility, this loop is also associated with flexible looping patterns (e.g. C and S type) to avoid excess stresses in the piping network. Further, the pipe stresses are checked for sustained loads, thermal expansion loads and occasional loads at maximum operating conditions of process loop. The calculated stresses are below the allowable values for all the cases mentioned in Table 4 and sufficient margins are available in the pipes. The accepted code stress criteria verifies the integrity of piping system. The present design is to be further analyzed for whip load, fire load and other assembly loads. This analysis may lead to slight change the loop layout and accordingly the stresses would be reassessed. REFERENCES [1] B. K. Yadav, A. Gandhi, A. K. Verma, et al., Conceptual design of experimental helium cooling loop for Indian TBM R&D experiments, world academy of science, engineering and technology Int. J. Physical and Mathematical Sciences, 8 (2) (2014). [2] B.K. Yadav, A. Gandhi, A.K. Verma, et al., Helium Cooling Systems for Indian LLCB TBM, Fusion Engineering and Design, 124 (2017) [3] A.K. Verma, B.K. Yadav, A. Gandhi, E.R. Kumar, et al., Pipe stress analysis of first wall helium cooling system for conceptual design development of IN LLCB TBM, Volume 137, December 2018, Pages [4] 3D Modeling Solutions CATIA - Dassault Systèmes 7
8 IAEA-CN-123/45 [5] Ceramic fibre blankets - Morgan Thermal Ceramics ( [6] Lubomir DIMITROV, Fani Valchkova, Problems With 3d Data Exchange Between Cad Systems Using Neutral Formats, Proceedings in Manufacturing Systems, Volume 6, Issue 3, 2011 ISSN [7] CAESAR II - Pipe Stress Analysis coade [8] Pipe Insulation Calculate Thickness 3E Plus Software [9] Process Piping Code ASME B31.3
Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components
1 /7-12 Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel IER and DEMO components M. Ionescu-Bujor, B.E. Ghidersa, G. Janeschitz, X. Jin orschungszentrum Karlsruhe, Germany e-mail:
More informationProfile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy
Profile LFR-43 HELENA ITALY GENERAL INFORMATION NAME OF THE FACILITY ACRONYM COOLANT(S) OF THE FACILITY LOCATION (address): OPERATOR CONTACT PERSON (name, address, institute, function, telephone, email):
More informationStart-up of the Three-shaft Closed Loop
Start-up of the Three-shaft Closed Loop Brayton Cycle Model of the PBMR Power Plant PG Rousseau, GP Greyvenstein & WMK van Niekerk, School of Mechanical and Materials Engineering, Potchefstroom University
More informationPreliminary Failure Mode and Effect Analysis for CH HCSB TBM
Preliminary Failure Mode and Effect Analysis for CH HCSB TBM Presented by: Chen Zhi Contributors by HCSB TBM Safety Group, in China June 21, 2007 E-mail: chenz@swip.ac.cn Outline Introduction FMEA Main
More informationDynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors
Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors C. Wang Cryomech, Inc. Syracuse, NY 13211 ABSTRACT This paper introduces the concept of operating a 4 K pulse tube cryocooler
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More information23.1 Functions, Basic Configuration, and Interfaces
23 (6.6.D) SF 6 and Other Special Gases 23.1 Functions, Basic Configuration, and Interfaces 23.1.1 Functions The primary function performed by the SF 6 and other special gases system is to provide SF 6
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationTechnical Specifications of Hydrogen Isotope Handling and Recovery System
SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I
More informationOil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane
Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane E.C. Luo, Z.H. Wu, G.Y. Yu, J.Y. Hu, and W. Dai Technical Institute of Physics and Chemistry Chinese Academy of Sciences
More informationUltraLo 1800 Alpha Particle Counter
XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation
More informationExperimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles
International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using
More informationDesign and Analysis of Pressure Safety Release Valve by using Finite Element Analysis
Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis Mr.V.D.Rathod* 1, Prof.G.A.Kadam* 2, Mr.V. G. Patil* 3 * 1 M.E. Design (Pursuing), SKN Sinhgad Institute of Technology&
More informationHTR Systems and Components
IAEA Course on HTR Technology Beijing, 22-26.October 2012 HTR Systems and Components Dr. Gerd Brinkmann Dieter Vanvor AREVA NP GMBH Henry-Dunant-Strasse 50 91058 Erlangen phone +49 9131 900 96840/95821
More informationOPERATION AND SIMULATION OF A THREE-SHAFT, CLOSED-LOOP, BRAYTON CYCLE MODEL OF THE PBMR POWER PLANT
OPERATION AND SIMULATION OF A THREE-SHAFT, CLOSED-LOOP, BRAYTON CYCLE MODEL OF THE PBMR POWER PLANT WMK van Niekerk, PG Rousseau & GP Greyvenstein School of Mechanical and Materials Engineering Potchefstroom
More informationServing. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants
Serving Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines ulk Gas Plants Mining & Metals Pharmaceuticals Pulp & Paper Mills Sugar Mills Nuclear Desalinization Plants NOTES:
More informationRELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY
RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY Yusuf Mansur Hashim M. Tech (Structural Engineering) Student, Sharda University, Greater Noida, (India)
More informationServing. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants
Serving Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines ulk Gas Plants Mining & Metals Pharmaceuticals Pulp & Paper Mills Sugar Mills Nuclear Desalinization Plants NOTES:
More informationIJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online): 2321-0613 Design Optimization and Fabrication of a Low Pressure Vessel Bhagatsinh Verma 1 Ankur
More informationUniversity of Cincinnati
Mapping the Design Space of a Recuperated, Recompression, Precompression Supercritical Carbon Dioxide Power Cycle with Intercooling, Improved Regeneration, and Reheat Andrew Schroder Mark Turner University
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationDesign, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller
IJSRD - International Journal for Scientific Research & Development Vol. 6, Issue 03, 2018 ISSN (online): 2321-0613 Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller Ajay A.
More informationFUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]
PAGE : 1 / 9 5. CONTAINMENT PURGE (EBA [CSVS]) The Reactor Building purge system comprises the following: A high-capacity EBA system [CSVS] [main purge] A low-capacity EBA system [CSVS] [mini-purge] 5.1.
More informationEDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4
EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS ASSIGNMENT No. 4 NAME: I agree to the assessment as contained in this assignment. I confirm that the work submitted is my own work. Signature
More informationIMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS
IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS Patrick BRAVAIS, Roland SALOME +, Cécile GELAS + * AIR LIQUIDE DTA + CNES Toulouse Abstract Plasmic propulsion systems
More informationRemotely-installed Hydraulic Module
Remotely-installed Hydraulic Module HDM 1.1-2.2 Single or twin pump ACC-PRC001E-GB Table of Contents Application Considerations Unit sizing...4 Unit placement... 4 Minimum water volume... 4 Selection Procedure...5
More informationBest Practices for Installation of Gaseous Sample Pumps
Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure
More informationISSN: Page 410
Study of Structural Stability of Globe Valve in Petroleum and Sugar Industries Anil Rathod 1, Dr. S N Kurbet 2 1 PG Student Mechanical branch (machine Design) BEC Bagalkot, Karnataka India, 2 HOD of Mechanical
More informationFigure 1 The LHC cryogenic islands and plants layout
The LHC cryogenic operation for first collisions and physics run Brodzinski K, Barth K, Benda V, Bremer J, Casas-Cubillos J, Claudet S, Delikaris D, Ferlin G, Fernandez Penacoba G, Perin A, Pirotte O,
More informationOverflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................
More informationOxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.
Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists
More informationOPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD
http:// OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD Anand Kumar S malipatil 1, Anantharaja M.H 2 1,2 Department of Thermal Power Engineering, VTU-RO Gulbarga,
More informationStep 1: Step 2: psi psi
General Tutorial on Evaluation of Nozzles by computing Local Shell Stresses as per WRC 537 and Stress Evaluation as per ASME Section VIII Division 2 using CAEPIPE Whenever Pressure Vessel or Heat exchanger
More informationExperimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events
Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute (JAERI),
More informationCooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas
Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas J. Ko, Y.J. Hong, H. Kim, H. Yeom, S.J. Park, D.Y. Koh Korea Institute of Machinery & Materials Daejeon, Korea (S), 305-343
More informationOverflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationEarlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.
17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower
More informationInternational Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE
Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 7, July -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 DESIGN CALCULATIONS
More informationSAMSON SOLUTIONS Energy and Power (Critical Applications)
SAMSON SOLUTIONS Energy and Power (Critical Applications) Speakers: Ing. Gianluigi Rossi Ing. Stefano Salvadori Managing Director - SAMSON Italy Head of Sales and Project Department - SAMSON Italy MARKET
More information1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER
1 SE/P-2 Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute,
More informationRICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES
RICK FAUL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES The primary design objective for any turbomachinery control system should be to maintain or maximize machine and
More informationTwo-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor
Volume 118 No. 18 2018, 4241-4252 ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Two-way Fluid Structure Interaction (FSI) Analysis on the Suction
More informationPressure regulating valves Types OFV, OFV-SS
Data sheet Pressure regulating valves Types OFV, OFV-SS OFV are angle-way pressure regulating valves, which have ajustable opening pressure and cover the differential pressure range ( P): 2-8 bar (29 116
More informationPVP Copyright 2009 by ASME
Proceedings of PVP 009 009 ASME Pressure Vessel and Piping Division Conference July 6-30, 009, Prague, Czech Republic PVP009-7746 UPDATE OF THE TABULATED «M AND Y» VALUES IN THE NEW REVISIONS OF FRENCH
More informationInfluencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology
More informationNORMAL OPERATING PROCEDURES Operating Parameter Information
Operating Parameter Information Each operator performing the normal operating procedures (routine checks) of the facility should be familiar with the current normal operating parameters of all systems
More informationControl & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system
Control & Maintenance INT69 Diagnose INT69 TM Diagnose Protect the heart of your system R INT69 DIAGNOSE The widely known protective system INT69 and INT69 TM present on all Frascold compressors is now
More informationAN EVALUATION OF ENCAPSULATED OIL FLOODED SCREW COMPRESSOR SYSTEMS. Nikola Stosic, Ahmed Kovacevic, ian K Smith and Elvedin Mujic
Proceedings of IMECE2007 2007 ASME International Mechanical Engineering Congress and Exposition November 11-15, 2007, Seattle, Washington, USA IMECE2007-43027 AN EVALUATION OF ENCAPSULATED OIL FLOODED
More informationUniversity of Cincinnati
Mapping the Design Space of a Recuperated, Recompression, Precompression Supercritical Carbon Dioxide Power Cycle with Intercooling, Improved Regeneration, and Reheat Andrew Schroder Mark Turner University
More information[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY PARAMETRIC STUDY TO UNDERSTAND THE SEISMIC BEHAVIOUR OF INTZE TANK SUPPORTED ON SHAFT Prasad S. Barve *, Ruchi P. Barve * Civil
More informationInternational Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.
DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008
More informationImproving distillation tower operation
Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast
More informationADVANCES in NATURAL and APPLIED SCIENCES
ADVANCES in NATURAL and APPLIED SCIENCES ISSN: 1995-0772 Published BYAENSI Publication EISSN: 1998-1090 http://www.aensiweb.com/anas 2017 June 11(8): pages 408-415 Open Access Journal Design of Absorptive
More informationDevelopment of High Efficiency 4K Two-Stage Pulse Tube Cryocooler
Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler M. Xu, H. Takayama and K. Nakano Sumitomo Heavy Industries, Ltd. Nishi-tokyo-city, Tokyo, Japan 188-8585 ABSTRACT Sumitomo Heavy Industries
More informationFirst Experimental Data of the Cryogenic Safety Test Facility PICARD
First Experimental Data of the Cryogenic Safety Test Facility PICARD C. Heidt, A. Henriques, M. Stamm and S. Grohmann 26 th International Cryogenic Engineering Conference 2016 in New Delhi, India KIT,
More informationEfficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Efficiency Improvement of Rotary Compressor by Improving the Discharge path through
More informationGas Vapor Injection on Refrigerant Cycle Using Piston Technology
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Sophie
More informationPressure Systems Safety Regulation
Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent
More informationAn Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler
An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler Mahesh N 1, S A Mohan Krishna 2 1 PG Student, Vidyavardhaka College of Engineering, Mysore,
More informationASERCOM guidelines for the design of multiple compressor racks using frequency inverters
ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING
More informationS-CO 2 Brayton Recompression Loop Design and Control
S-CO 2 Brayton Recompression Loop Design and Control 1) Background 2) Recommended Design Features 3) Modeling Strategy IST Model Changes Transient Results Prepared by: Mike Hexemer Advanced Concepts Knolls
More informationFlexible Metal Hose Products
Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationDevelopments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry
Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at
More informationLow GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals
Low GWP R-404A Alternatives for Commercial Refrigeration Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals Chillventa Nűrnberg October 9-11, 2012 Topics Regulatory Environment Properties of New Refrigerants
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationLP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand
Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal
More informationS265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications
Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance
More informationResearch of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor
More informationCable in Conduit Conductor (CICC) quench modelling
DEMO SAMPLE Cable in Conduit Conductor (CICC) quench modelling This demo gives an example of quench simulation for a Central Solenoid (CS). CS is divided into geometrically identical sections (see Fig.
More informationDESIGN AND THERMAL-HYDRAULIC PERFORMANCE OF A HELIUM COOLED TARGET FOR THE PRODUCTION OF MEDICAL ISOTOPE 99M TC
DESIGN AND THERMAL-HYDRAULIC PERFORMANCE OF A HELIUM COOLED TARGET FOR THE PRODUCTION OF MEDICAL ISOTOPE 99M TC Keith Woloshun, Gregory E. Dale, Charles T. Kelsey IV, Eric R. Olivas, Michael A. Holloway,
More informationLinear Compressor Suction Valve Optimization
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Linear Compressor Suction Valve Optimization Rinaldo Puff Embraco, Brazil, rinaldo.puff@embraco.com
More informationFitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study
The International Journal Of Engineering And Science (IJES) Volume 6 Issue 2 Pages PP 12-16 2017 ISSN (e): 2319 1813 ISSN (p): 2319 1805 Fitness for Service Assessment of Ageing Pressure Vessel Experiencing
More informationProducts for Cryogenic Applications
Products for Cryogenic Applications Cryogenic valves, self-operated regulators, differential pressure meters SMART IN FLOW CONTROL. Designed for cryogenic service Industry, medicine, supply engineering
More informationInformation Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100
Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet
More informationDesign. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle
SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made
More informationCustomer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationLiquid Lead-Bismuth Materials Test Loop
Liquid Lead-Bismuth Materials Test Loop Valentina Tcharnotskaia, Curtt Ammerman, Timothy Darling, Joe King, Ning Li, Don Shaw, Leon Snodgrass, Keith Woloshun. Los Alamos National Laboratory, P.O. Box 1663,
More informationInspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement
Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement Glenn A. White, Kyle P. Schmitt, Kevin J. Fuhr, Markus Burkardt, and Jeffrey A. Gorman Dominion Engineering, Inc. Paul Crooker
More informationFUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])
PAGE : 1 / 16 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS]) 7.0. SAFETY REQUIREMENTS 7.0.1. Safety functions The main functions of the EVU system [CHRS] are to limit the pressure inside the containment
More information44 (0) E:
FluidFlow Relief Valve Sizing Handbook Flite Software 2016 Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd, Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 E: sales@fluidflowinfo.com
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationRecirculating Coolers
(Chillers) - Basic type Low Temp. - General Type Low Temp. - Intelligent type Selection Guide Recirculating Cooler Basic type General type (Low temp.) Intelligent type (Low temp.) Working Temp. Range (
More information2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications
Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity
More informationTwo-stage pulse tube refrigerator with step displacer as phase shifter
IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Two-stage pulse tube refrigerator with step displacer as phase shifter To cite this article: Shaowei Zhu 2015 IOP Conf. Ser.:
More informationPERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT
PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE M. FUKUTA, T. YANAGISAWA, S. NAKAYA (b), and Y. OGI Shizuoka University, 3-5-1 Johoku Hamamatsu, 432-8561, Japan Fax +81-53-478-158,
More informationLiquid ring compressors
Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement
More informationIdentification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI
Identification and Screening of Scenarios for LOPA Ken First Dow Chemical Company Midland, MI 1 Layers of Protection Analysis (LOPA) LOPA is a semi-quantitative tool for analyzing and assessing risk. The
More informationApplication of Computational Fluid Dynamics to Compressor Efficiency Improvement
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Application of Computational Fluid Dynamics to Compressor Efficiency Improvement J.
More informationSelection of ICF made easy Save even more time with ICF
MAKING MODERN LIVING POSSIBLE Selection of ICF made easy Save even more time with ICF ICF stands for valve trains and for over five years installation and service has never been easier. This quick guide
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationOperational Behaviour of Safety Valves with Constant Superimposed Backpressure
Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Arne Gastberg Albert Richter ARI-Armaturen GmbH & Co. KG When selecting spring loaded safety valves, an accurate knowledge
More informationWP2 Fire test for toxicity of fire effluents
Pagina 3 di 89 TRA SFEU VTT 22.6.2009 v.2 WP2 Fire test for toxicity of fire effluents Task 2.1.2 Development of small-scale test method for fire effluents Step 1: Use of modeling Plans according to DoW:
More informationCNS In-Pool Assembly Mechanical Design for OYSTER Project
CNS In-Pool Assembly Mechanical Design for OYSTER Project JINBOK CHOI, JUNGHYUN RYU Korea Atomic Energy Research Institute (KAERI) 111 Deadeok-daero 989Beon-gil, Yuseong-gu, Daejeon, Republic of Korea
More informationCONTAINMENT OF CO2 REFRIGERATION INSTALLATIONS
CONTAINMENT OF CO2 REFRIGERATION INSTALLATIONS X. CAZAURAN, S. GUYOT, C. HERMON CETIM, Centre Technique des Industries Mécaniques, 74 route de la Jonelière, 44326 Nantes, France Fax : +33 ()251 86 73,
More informationDesign and optimization of a low pressure vessel
Abstract Research Journal of Engineering Sciences ISSN 2278 9472 Design and optimization of a low pressure vessel Available online at: www.isca.in, www.isca.me Received 8 th April 2017, revised 11 th July
More informationSchedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT
S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled
More informationHazard Operability Analysis
Hazard Operability Analysis Politecnico di Milano Dipartimento di Energia HAZOP Qualitative Deductive (search for causes) Inductive (consequence analysis) AIM: Identification of possible process anomalies
More informationSALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN
SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN DOUG ADLER UNIVERSITY OF WISCONSIN NIR THERMAL SYSTEMS Three primary thermal systems: Predewar, Dewar, and Electronics NIR instrument
More information