BBB2 Vacuum Bubble Buster

Size: px
Start display at page:

Download "BBB2 Vacuum Bubble Buster"

Transcription

1 The Compete Guide to Creating Bubbleless Gel Candles with the BBB2 Vacuum Bubble Buster Deb Puerini Gel Candles by Deb E. Providence, RI Steve Hansen the Bell Jar Amherst, NH

2 The Genesis of the name BBB (Boyle's Bubble Buster) Boyle's Bubble Buster is our nickname for the Gel Candle Debubbler. It is named in honor of Robert Boyle ( ). Boyle was a chemist and a natural philosopher. He was noted for his pioneering experiments on the properties of gases and his views of matter. His work led to the modern theory of chemical elements. While at Oxford Boyle collaborated with Robert Hooke in constructing an air pump with which he conducted the experiments leading to his publication (1662) of the relationship, now known as Boyle's law, that at constant temperature the volume of a gas is inversely proportional to its pressure. The complete story of the origins of the BBB can be found in the article Bubbles and Gel Candles which can be found on the Web at Later on in this instruction manual you will also find information on the theory behind the BBB. Page 1

3 A Note on Safety Working with vacuum can be dangerous. Please read this entire manual before attempting to use the BBB. If you have any questions, please do not hesitate to contact either of the authors before proceeding. Your vacuum chamber is designed to work safely under full vacuum as long as it is undamaged. Check it frequently for deep scratches or chips. A damaged chamber should not be used. Any vacuum device will implode if it fails. To protect yourself it is best to wear safety glasses whenever the unit is operating. Keep as much of your body covered as possible. Melted gel is hot. Use suitable insulated mitts when handling hot gel. Never leave the apparatus under vacuum for extended periods or when unattended. Whenever the pump is turned off, immediately vent the chamber to atmospheric pressure (0 on the gauge). The pump's exhaust will emit a fine mist of oil vapor. Your work area should be well ventilated. For normal use just placing a cloth rag over the pump s exhaust will collect virtually all of this vapor. Don't put any living critters in the debubbling chamber. Also don't put in any water, solvents or toxic materials. Some materials will react violently when placed under vacuum Page 2

4 Getting Started with your BBB Vacuum Debubbler Congratulations on your purchase of the original BBB which has been developed specifically for maximum elimination of bubbles in gel candles. Nothing works as well and as dependably. Vacuum debubbling is a standard technique in industry for eliminating bubbles in plastic moldings and potted assemblies where the presence of bubbles could cause anything from performance problems to catastrophic failure. The wide use of vacuum debubbling is a testimony to the efficiency of this method. While other techniques can work under some circumstances, only the application of vacuum technique can assure consistent success and productivity The team of Deb Puerini and Steve Hansen have developed a simple to use system, the BBB, that will make the production of beautiful, clear gel candles an easy and relatively straightforward task with immediate results and no guesswork. Unpacking When you receive the BBB you will find two major items: the vacuum pump & manifold and the plastic debubbling chamber. Other parts with the kit include: Vacuum pump fluid (oil) with Material Safety Data Sheet (MSDS) Pyrex glass beaker Operating manual for the pump These instructions Carefully unpack the items and place them on a table where you can become familiar with the bits and pieces before actually assembling and operating the system. What's All that Stuff on the Vacuum Pump? The vacuum pump is a precision machined device that is capable of achieving very low pressures. It's properly called a two-stage oil-sealed rotary vane vacuum pump. In brief this means that the pumping mechanism has two parts (stages) arranged in series with everything immersed in oil. The oil serves as both a lubricant and as a sealing agent for the sliding vanes. The oil must be clean (change it regularly) and of sufficient quantity to do its job. Too little oil and the pump will not work properly and will, in fact, seize up. Dirty or contaminated oil will result in a poor vacuum and corrosion of the pump parts. Set the pump on a table and read the following to get familiar with the various parts of the vacuum pump. Page 3

5 The rear portion of the pump is the motor (see Figure 1 below). At the very back end are the 3-prong power cord and on/off switch. You will probably have to use an extension cord. Make sure that your cord is grounded (3 prong). Do not use a 2 prong ungrounded cord. Figure 1 - Rear of vacuum pump showing power cord and on/off switch. The business part of the pump is at the other end (see Figures 2A and 2B). At the very end on the pump housing (bell) is a clear window (sight glass) which is used to check the oil level. Just above and behind that on the top of the bell is the vent. This is where the pumped air gets expelled from the pump into the air. The vent is also where you add oil to the pump. There is a fitting (either a brass hose connector or vented cap) in this vent opening. Remove the fitting or cap to add or drain the oil but put the fitting or cap when the pump is actually being used. Under no circumstances should this vent port be plugged as damage to the pump will result. At the rear of the bell is a little screw plug called the gas ballast. This is normally used when pumping very moisture laden air but we will not use it in the BBB application. Check to be sure that it's tight (fully screwed in) and leave it there. If you are curious about when the ballast is used and how to use it, check the pump manual. Vent Vent Sight Glass Gas Ballast Figure 2A, 2B - Business end of vacuum pump. Page 4

6 The part that you will work with mostly is the brass manifold assembly that is connected to the inlet of the pump (see Figure 3). This manifold is for the most part made of brass plumbing fittings, all screwed together and sealed with a vacuum-compatible adhesive sealant. (Do not attempt to take any of these pieces apart as you will break the adhesive seals and you will no longer get a good enough vacuum for efficient debubbling.) Pressure Control/ Relief Valve Figure 3 - Manifold Assembly Gauge Inlet Hose Connector (Behind) The three parts of the manifold that you will be interested in are the inlet hose connector fitting, the pressure control/vacuum relief valve, and the vacuum gauge. The inlet hose connector attaches to a short length of 3/8 inside diameter clear plastic tubing which is supplied already attached. Take care when using the pump that excessive amounts of dust or dirt are not drawn into the pump as these will cause the pump to wear or seize. The pressure control/vacuum relief valve is simply a small plastic or metal cap with a rubber o-ring inside. When the cap is fully tightened and the pump is connected to your debubbling chamber, the pump will produce the best vacuum that it can. By slightly loosening the cap you can regulate the pressure in the chamber anywhere between full vacuum and no vacuum. When you have finished a debubbling operation, you turn off the pump and fully loosen the cap to let air into the chamber. The vacuum gauge is a simple dial-type gauge that gives you a good idea of how good a vacuum is being produced (more on this later). The debubbling chamber (see Figure 4) is a commercial plastic desiccator to which we have added a length of plastic vacuum-compatible hose. Figure 4 - Debubbling Chamber. This consists of a clear plastic top, opaque bottom with o-ring seal and connecting vacuum hose. Note the safety placard. Page 5

7 Examine the debubbling chamber. You will see that the lower half has a rubber o-ring that is used to seal the two parts together. Be sure that this is kept clean and dust free. Dust, hairs, etc. on the o-ring will cause the seal to leak and will result on a poor vacuum. Now find a good location for your BBB. Everything should be at table height and the platform should be stable. You may want to have a small metal tray under the pump to catch any small dribbles of oil. Once you have situated your BBB connect the loose end of the vacuum tubing that is attached to the debubbling chamber to the barbed inlet fitting on the slightly smaller tube that is attached to the pump's manifold. This should slide on with just a moderate amount of force. It should not be loose. For best results the tubing should have as few bends as possible and definitely no kinks. Avoid any tendency to add more tubing as that will impair the performance of the pump. Figure 5 shows a good installation. Figure 5 - Pump and Chamber Connected. Note that there are two pieces of slightly different diameter hoses that are connected with a plastic adapter. The hose clamp on the chamber's fitting should be tight enough to secure the hose but not so tight as to stress the plastic. Now add oil to the pump. Remove the cap or fitting from the pump's vent and, with a clean and dry funnel, add oil slowly until the oil level is half way up the sight glass. Not much more, not much less. If you add too much simply pick the pump up and invert it to drain a bit of oil. Now replace the vent fitting. Page 6

8 Science Stuff: How Vacuum is Measured To successfully run the BBB you need not be able to express pressure in Newtons per square meter or to be able to convert millibar units to Pascal. However, you should understand a bit about what the vacuum gauge is telling you. At sea level our atmosphere exerts a pressure of about 14.7 pounds per square inch (psi). Pressure can also be measured in units that are derived from the weather barometer. That 14.7 psi ambient atmospheric pressure will support a column of mercury that is about 30 inches high (inches of mercury or inhg). When you listen to your local weather guy (or guyess) he (or she) may say that the something like "the barometer is inches and rising." That doesn't mean that the barometer is levitating but that the reading (which is stated in terms of a barometer's mercury column) is some value and increasing. What that means is that the 30 inhg is just a typical value and can vary by weather conditions or by height above sea level. (Denver is normally about 26 inhg because they are a mile above sea level. A barometer would read zero inhg in space because space is a really good vacuum.) The gauge that is supplied with your BBB reads 0 to 30 inches but you will note that when the BBB is not running the gauge reads 0. As the pressure goes down (more vacuum) the reading increases. This is opposite what barometer readings are just because that's what all the pump manufacturers do. Just keep in mind that normal pressure is zero and full vacuum is 30. And, of course, if you are at a high elevation (Denver, Albuquerque, etc.) full vacuum is going to be something less than 30. Don't worry too much about this as what we'll be doing for the most part is looking at what's happening in the chamber, not what the gauge says. However, the gauge readings will provide important reference points as we'll see later. If you really want to get the lowdown on vacuum measurement units, check out Doing a Trial Run For anyone who has never dealt with vacuum apparatus, it can all seem quite daunting. However, the equipment is fairly simple and easy to use. Before we actually try to use it do debubble gel, let's get familiar with how it works. Make sure you have everything connected, oil to its correct level, nothing in the debubbling chamber and safety glasses on. Place the lid on the lower half of the chamber. Apply a bit of pressure with your hand to make sure that it is closed tightly. With the screw cap of the pressure control/vacuum relief valve partially open, turn on the pump. You will hear a gurgling sound as air bubbles through the pump's oil bath. Page 7

9 Look at the vacuum gauge. It should be reading some value more than zero indicating that you have a partial vacuum. Once you have a reading of more than about 5 inches you should be able to let go of the chamber's lid. The pressure from the atmosphere will hold the lid on. Start to close the pressure control/vacuum relief valve's cap in tiny increments (turn clockwise). You should see the gauge reading start to increase even more. Try to set the pressure at 20, 25, 28, 29 by varying the tightness of the cap. Close the cap fully and see what the gauge reads. At sea level it should read about 30 but don't worry too much if the reading is a bit different. Let the pump operate for 10 to 20 minutes. You will note that the gurgling sound pretty much disappears (if it doesn't you may have a leak) to be replaced by a sort of clicking sound with maybe some intermittent gurgles. The clicking sound is the pump's exhaust valve and this is normal. Make a note of your final pressure reading. This is called your base pressure and is your reference for a full vacuum. When you are ready to turn the pump off first open the vent screw cap to let some air in and then shut off the pump. Immediately open the vent screw cap fully to bring the gauge reading to zero. It is important to quickly vent the system once you have turned the pump off. If you don't, some of the oil in the pump will get sucked back into your lines and chamber making a real mess. (If this does happen, don't despair. Raise the chamber so that the oil in the tubing can go back into the pump when you turn it on briefly. Then clean any residual oil that may have gotten into the chamber with a solution of water and a mild soap (e.g. Ivory). Dry with a lint free towel and check the level of oil in the pump.) A Nifty Experiment Deb really likes this one and it's a classic vacuum demonstration that shows how the debubbler works. Place a marshmallow (preferably one of the big ones) or a marshmallow Peep (this is really sadistic) into the debubbler chamber. Close it up and apply vacuum as in the above section. Note the size of the marshmallow as the pressure drops. It will get quite large. This is because the marshmallow is composed of thousands of air cells. As the pressure drops (gauge reading goes up), the bubbles expand. The amount that the bubbles expand is directly related to the change in pressure in the vacuum chamber. When the pressure is 29 inches the bubble will expand by a factor of 30. As noted before, this relationship between pressure and volume was discovered by Robert Boyle and is referred to as Boyle's Law. Now turn off the pump and vent the chamber back to atmospheric pressure. The marshmallow will literally collapse because the bubbles, in their expansion, also broke. This is what you will be doing with the gel when you debubble it. Figure 6 on the next page is a picture of a marshmallow Peep that is under vacuum. Page 8

10 Figure 6 - An Expanded Marshmallow Peep under Vacuum. Poor thing. (Don't try this with your gerbil.) A Debubbling Test with Real Gel Now prepare a small container of melted gel. Don't use too much as we are still trying to get familiar with this whole vacuum thing. Put the container of melted gel in the debubbling chamber and close the lid. Turn on the pump with the vent valve cap partially closed. Quickly start to reduce the pressure (gauge reading goes up) to about 20. Then continue to drop the pressure by gently closing the vent cap in small increments. Go in increments of 1. At some point you will see the bubbles start to get bigger. Then you will see them start to rise more quickly to the surface and then break. As the vacuum gets better and better the bubbling will become more energetic. This is where it is more important to see what's going on rather than watching the gauge's reading. You don't want the action to get too out of control as the gel may actually froth and overflow. No big deal but that's messy and you will have to clean spilt gel out of the chamber. Just imagine what a real candle would like. For people who are at sea level, the bulk of the action happens at gauge readings somewhere between 29 and 30 inches. Figure 7 shows debubbling in progress. Figure 7 - Air bubbles dutifully obeying Boyle's Law by expanding like crazy and rising to the surface whereupon they break and are never seen again. Page 9

11 A Full Run and Other Hints from Deb Please familiarize yourself with all of the basic aspects of gel candle making before attempting to use the BBB. We want you to be successful and a piece of equipment, no matter how good, won't get you there unless you are knowledgeable of the basics. We strongly recommend the ebook How To Make Gel Candles That Sell Like Wildfire which is available as a download from Read this book cover to cover at least twice, it is our "bible" and, in the opinion of many, the BEST gel candle making book EVER. As you can see in Figure 8 below, I have two separate melting pots - one for regular, unprocessed gel and one for the debubbled gel. I go on debubbling jags and try to fill the debubbled pot up so I can have it ready when the mood strikes. I got the one on the right in Walmart's housewares department, It's called a Presto Kitchen Kettle. They are about $20.00 around here. The other one is a deep fryer with incremental temperature control (not just low, medium, high) that I got at a thrift shop. The most important attribute of a good melting pot is that it has incremental temperature control. The most important accessory is a candy thermometer for each of your melting pots since the controller on the pot won't give you an accurate indication of the real temperature. Figure 8 - Melting pots for raw gel and debubbled gel. Note the candy thermometers. Now, what temperature is the best for debubbling gel? The hotter the better, but not too hot or you will scorch the gel. My general rule of thumb is at least 250 degrees F but not over 275. I use a 1 cup metal measuring cup to transfer the hot gel from the melting pot to the beaker to be debubbled. But you can experiment to find what works best for you (raid your kitchen for tools!). Another good idea is to get an electric griddle (the bigger the better) on which to set your smaller pots of already melted gel, ready for scenting and/or coloring. This will keep them nice and warm. I just have a small one but it does work well if you have a lot of little pots of different scented and colored gels. Page 10

12 If you want to color and/or scent, I suggest you do that first before debubbling, as doing it later will reintroduce air to the gel. Just put your scented/colored gel onto the griddle or on the stove for a bit to get it hot again (don't forget the thermometer and NEVER let it leave your sight). With the gel container in the vacuum chamber, turn on the vacuum pump and let it go at full vacuum for about 3 minutes (remember, if it looks like the debubbling is getting too wild, raise the pressure just a bit (probably just 1/2 inch will do) until things slow down and then return to full vacuum. It will still look as if there are tons more bubbles to get out, but don't worry, this is just fine. Keep your eye on it, you can jiggle the chamber just a bit if the bubbles don't seem to be going as fast as they did at first. I put some rubber material in the bottom so the beaker won't slip and in case some gel bubbles over, it will collect on the rubber mat and not stick the beaker directly to the chamber (it happened to me and I didn't have that rubber underneath it and it was really hard to get the beaker out). When it's done debubbling, you can now pour directly into your candle, let it sit on the griddle, or pour it into your "debubbled" melting pot for later use. Don't worry about a lot of leftover gel in the beaker. Let it cool off and it will just peel out and you can drop it in the debubbled gel pot. I encourage you to try to find a better beaker to put gel in to debubble. Because of the size of the chamber, it is hard to do, and the beaker that is provided is the best I could find. You do need a handle (as you will see after trying it for the first time) and handled beakers or pitchers of the right size are really difficult to find. (If I find a better one, I'll let you know. If you find a better one, let us know!) Tips for Minimizing Bubbles that come from Embeds The warmer everything is the better. And the slower you pour the better. If you can break the fall of the gel with something (like an embed) that is better. If you have sand in the bottom of your candle, be sure to pour a thin layer of gel to cover the sand and then let it completely cool off. Otherwise you will get big air "blurps" from the air in the sand. Mostly, have fun and experiment! You will find your own way of doing things, and if you find a cool tip be sure and share it with us at the Yahoo gel candle groups!! Remember, don't hesitate to me about gel and Steve about vacuum. We're here to make this experience a GREAT one!! Regular Maintenance of your BBB Your BBB requires very little maintenance. Just keep all of the parts clean with an occasional wiping with a clean, dry, lint-free cloth. For a more thorough cleanup, if required, you may use warm water with a mild, pure & unscented soap (e.g. Ivory dish detergent). Do not use solvents as these may attack the seals or plastic surfaces. Under no circumstances should you use any abrasives such as scouring Page 11

13 pads. If water has been used for cleaning, make sure all surfaces are dry before using with the vacuum pump. Water will contaminate the pump oil instantly. The most important part of maintenance is keeping the pump oil clean and at the proper level. Before each debubbling run make sure that the oil level is midway in the sight glass. We recommend that you change your oil on a monthly basis or more often if the oil appears darkened (dirty/contaminated) or milky (a sure sign of lots of water content). To change the oil take the fitting off of the exhaust port and invert the pump over a funnel or collecting pan. Discard the oil in a proper manner (local service station, at the town dump, etc.) as you would automobile engine oil. If your oil is very contaminated we recommend that you refill the pump, run it for about 30 seconds, and then drain and refill again. Replacement Parts Pump oil: Vacuum pump oil can be obtained from local dealers who cater to the air conditioning trade (look in the yellow pages for HVAC). The most common brands are Robinair and J/B Industries. If you have trouble finding pump oil, please contact us. In a pinch you can use 30 wt auto engine oil. However this tends to be a bit smelly but it does work fine. Cap for pressure relief/vent: This is the little metal or plastic cap with o-ring. If you lose it, you may get a replacement for $6.00 ppd. in the USA. O-ring for debubbling chamber: We can supply these for $8.00 ppd. Further Assistance Any questions or feedback, please Steve for problems or questions with regard to the equipment shansen@tiac.net Deb for issues related to candlemaking with the BBB lovesalsa@cox.net Also be sure to visit Steve's vacuum web site, the Bell Jar, at If you are science minded you will also get a host of ideas for other applications that your vacuum pump can be used for. By March 2003 there will also be a message board at belljar.net which will include an area for vacuum applications in arts & crafts. Page 12

14 Examples of Debubbled Candles using the BBB Page 13

BBB Vacuum Bubble Buster

BBB Vacuum Bubble Buster Creating Bubbleless Gel Candles with the BBB Vacuum Bubble Buster Deb Puerini Gel Candles by Deb E. Providence, RI Steve Hansen the Bell Jar Amherst, NH The Genesis of the name BBB (Boyle's Bubble Buster)

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

5 Gallon Pressure Pot with HVLP Spray Gun and Hose California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,

More information

1. CONDITIONS FOR USE 2. SAFETY

1. CONDITIONS FOR USE 2. SAFETY 1. CONDITIONS FOR USE This micro abrasive blaster may only be operated: Indoors; Below 6500 ft above sea level altitude; Ambient air temperature between 40-105 F (5-40 C); Maximum relative humidity of

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006 Nov 2006 Place the H2-40 on a benchtop surface which will not be damaged by water in the event of a leak. Fill a bottle with clean water. Tapwater is OK in most large cities, but bottled drinking water

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in this instruction manual. 1 CONTENTS 3. Safety Precautions

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

Rejuvenation Instructions

Rejuvenation Instructions Rejuvenation Instructions #401 Air Systems UPR This NRI covers the following: Understanding the applications and operation of flow meters. Understand the application and operation of test pressure gauges.

More information

Columbia Taping Tools. Hydra Reach Handle. Manual

Columbia Taping Tools. Hydra Reach Handle. Manual Columbia Taping Tools Hydra Reach Handle Manual Table of contents Warning 2 Introduction 3 Before you start, identify your handle 4 What is your problem? 5 Reservoir Upgrade 5 Setting up the loading system

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Glove Box Installation Manual

Glove Box Installation Manual Glove Box Installation Manual 1998 by M. Braun Company File: GB-UNI-INS.DOC! Edition 08-00 by M. Boutin! Subject to be changed without notice Glovebox Installation Your Glove box has been fully assembled,

More information

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases.

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases. PROPERTIES OF GASES: PRESSURE, VOLUME, TEMPERATURE, & SOLUBILITY RELATIONSHIPS PURPOSE: To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS 6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS USER MANUAL -1- SI-BARNET DEADWEIGHT TESTER 6000 SERIES Release: S31-0250 Revision: A Date: 05/08/03 MANUFACTURED BY: GE RUSKA RUSKA INSTRUMENT CORPORATION 10311

More information

General No. 25 and D-25 Handy Operating Instructions

General No. 25 and D-25 Handy Operating Instructions General No. 25 and D-25 Handy For 1-1/4 through 3 lines (30mm 75mm) No. 25 Handy D- 25 Handy This tool is designed to give you years of trouble-free, profitable service. However, no machine is better than

More information

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves Instruction Manual PE-25/32/37 Tapping Machines & POLYTAPP Valves Nov 2016, Revision 2 Document Number 3000111 2 M.T. Deason Company, Inc. PO Box 101807 Birmingham, AL 35210 Phone: 205 956 2266 Fax: 205

More information

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes. Telemark Biathlon Where performance and precision come together http://telemarkbiathlon.com Rifle Cleaning Date : July 19, 2013 Anschutz Rifle Manual - Click Here Izhmash 7-3 Rifle Manual - still looking

More information

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTION ARCHON Industries, Inc Liquid Level Gauges Models: BT-LLG ND-LLG INSTALLATION & MAINTENANCE INSTRUCTION Instruction No.: 1014.2 Revision Issued: 3/01/03 Approved: Engineering Manager Warning ONLY QUALIFIED

More information

FOR SAFE AND CORRECT USE

FOR SAFE AND CORRECT USE FOREWARD Thank you for purchasing the Model AP-20 sampling pump. The Model AP-20 pump is designed specifically for use with Kitagawa detector tubes. This system with the available Kitagawa detector tubes

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER TM easycomposites share the knowledge SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER 26L Vacuum Degassing Chamber 26L Starter Vacuum Degassing

More information

VACUUM CHAMBER MANUAL

VACUUM CHAMBER MANUAL VACUUM CHAMBER MANUAL INDUSTRIAL VACUUM CHAMBERS CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City,

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

Nitrogen Tyre Inflator Owner s Manual

Nitrogen Tyre Inflator Owner s Manual Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

Operating Instructions

Operating Instructions Operating Instructions PRECISION AIR ENTRAINMENT METER Model: 34-3265 (CT-126A) TABLE OF CONTENTS I. GENERAL INFORMATION...1 II. RELATED USER DOCUMENTATION...2 FIGURE 1 -- AIR ENTRAINMENT METER...3 III.

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

We can tell that diameter of the tube influence the pressure of the water at the bottom.

We can tell that diameter of the tube influence the pressure of the water at the bottom. IDS 102 Pressure Part II You may have found that there is a slight difference in the distance of the two streams, but this is due to frictional forces between the water and the tube, not the different

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

AIR/OVER HYDRAULIC JACK 20 TON

AIR/OVER HYDRAULIC JACK 20 TON AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.

More information

LABORATORY TECHNIQUES. Pouring Liquids

LABORATORY TECHNIQUES. Pouring Liquids LABORATORY TECHNIQUES Working in the chemistry laboratory you will be handling potentially dangerous substances and performing unfamiliar tasks. This section provides you with a guide to the safe laboratory

More information

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List 1 Liter High- Pressure Gel Coat Spray Gun 134-A Usage Instructions & Parts List www.fibreglast.com 1.800.821.3283 385 Carr Drive Brookville, OH 45309 Operating Instructions & Suggestions This is a high

More information

Bottle Rocket Launcher P4-2000

Bottle Rocket Launcher P4-2000 WWW.ARBORSCI.COM Bottle Rocket Launcher P4-2000 BACKGROUND: The Bottle Rocket Launcher allows for the exploration of launching rockets using commonly available materials such as plastic soda bottles and

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

"RESPIRATORY PROTECTION AND SAFETY"

RESPIRATORY PROTECTION AND SAFETY PRESENTER'S GUIDE "RESPIRATORY PROTECTION AND SAFETY" Training for the OSHA RESPIRATORY PROTECTION STANDARD Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

Installation Instructions

Installation Instructions Model: ACT-4500 ACT-4500-3 ACT-4500-6 SUN ELECTRIC CORPORATION Page: 1 of 5 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SUN PERSONNEL ONLY INSTALLATION OVERVIEW: The Installation

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

COMPRESSOR MANUAL. (888)

COMPRESSOR MANUAL.   (888) COMPRESSOR MANUAL www.ultimadentalsystems.com (888) 900-8584 Table of Contents Introduction..Page 2 Quick Compressor Start Guide....Page 3-5 Compressor Pump Diagram....Page 6 Compressor Frame Diagram....Page

More information

Installation Instructions

Installation Instructions Model: ACT-4100 ACT-4100-3 ACT-4100-6 SUN ELECTRIC CORPORATION Page: 1 of 5 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SUN PERSONNEL ONLY INSTALLATION OVERVIEW: The Installation

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Table of Contents Want full page pictures with most important parts labeled in the beginning. 1 Table of Contents Want full page pictures with most important parts labeled in the beginning. Precool Procedures (Perform before cooling down): 1. Check N2 and 4He gas tanks to be sure that there is

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTRUCTION MANUAL. January 23, 2003, Revision 0 INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,

More information

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS 1 Introduction... 1 2 Abrasive Regulator... 2 2.1 Regulator Installation... 2 Location... 2 Attaching the Regulator to the Machine...

More information

256 Pneumatic Pressure Indicator

256 Pneumatic Pressure Indicator 256 Pneumatic Pressure Indicator 51425699 Copyright 2002 Slope Indicator Company. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any

More information

Physics Experiment 17 Ideal Gas Law Qualitative Study

Physics Experiment 17 Ideal Gas Law Qualitative Study Physics 210 17-1 Experiment 17 Ideal Gas Law Qualitative Study Note 1: Parts of this lab involve using a laptop computer and the PASCO ScienceWorkshop Interface to collect data. The lab also involves use

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A. Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2

More information

ATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL

ATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL ATD-8401 40 LBS. PRESSURE BLASTER INSTRUCTION MANUAL ATD abrasive blasting equipment is designed for cleaning and removing rust, scale, paint and dirt. It is the ideal method for stripping, polishing and

More information

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before

More information

MB-SP Series Solvent Purification System

MB-SP Series Solvent Purification System Operation Manual MB-SP Series Solvent Purification System Table of contents 1. System overview 2 2. Column activation.. 5 3. System purging.. 6 4. Glove box integration.... 7 5. Solvent reservoir installation....

More information

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES THE COLD WELDING EQUIPMENT The equipment needed to take ~ 45 gram water samples in copper tubes is shown in the figures below. Figure 1 shows the

More information

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer RC Unofficial Manual to the Solvent Dispensing System Designed by J. C. Meyer 1 Table of Contents: I. Introduction...3 II. rgon Supply...3 Tanks Regulators Over Pressurization III. Solvent Kegs...4 Solvent

More information

Operation Manual Guillotine Cutter RC-5

Operation Manual Guillotine Cutter RC-5 Operation Manual Guillotine Cutter RC-5 Technical Specifications General Safety/Operating Instructions Using the Guillotine Cutter/Crimper Blade Change Instructions Maintenance Instructions This is a detailed

More information

Spot Weld Drill Spot Weld Removal System Instruction Manual

Spot Weld Drill Spot Weld Removal System Instruction Manual 85-1001 Spot Weld Drill Spot Weld Removal System Instruction Manual Version 1.1 TABLE OF CONTENTS COMPONENT CHECKLIST 2 GENERAL SAFETY - READ BEFORE USING 3 INSTALL AND STORAGE MAINTENANCE INSTRUCTION

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Tempe Pressure Cell June 1995 Fig. 1a 1400 Tempe Pressure Cells with 3cm cylinders and 6cm cylinders) mounted on the Tempe Cell Stand Fig. 1b Disassembled 1400 Tempe Pressure Cell

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:... 1 2.1 Regulator

More information

Checklist for care of Respirators

Checklist for care of Respirators Checklist for care of Respirators Inspect the respirator before and after each use and during cleaning. Inspect equipment designated for "emergency use" at least monthly, and after each use. Replace all

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this INSTRUCTION MANUAL AIRBRUSH COMPRESSOR AS-48A Thanks for purchasing our airbrush compressor and please read this Instruction Manual carefully and thoroughly before operating the tool to get best performance.

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

1 DRIVE INDUSTRIAL IMPACT WRENCH

1 DRIVE INDUSTRIAL IMPACT WRENCH 1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight

More information

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams. Heat Engine Equipment: Capstone, 2 large glass beakers (one for ice water, the other for boiling water), temperature sensor, pressure sensor, rotary motion sensor, meter stick, calipers, set of weights,

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage

More information

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412) SECTION Bypass Oil Sampling Station (B.O.S.S 1000) GENERAL.......................... SAFETY........................... Hazards............................... Personal Protective Equipment........... PRODUCT

More information

Techcon Systems TS1254 Pressure Pot

Techcon Systems TS1254 Pressure Pot Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION

More information

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes Module 2, Add on Lesson Depth Sensor 90 minutes Teacher Purpose of this lesson Investigate the relationship between pressure and depth Construct a sensor to measure the depth of water Graph data and reason

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Thanks for choosing EJAI SOLAR product

Thanks for choosing EJAI SOLAR product SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2

More information

Gases and Pressure. Main Ideas

Gases and Pressure. Main Ideas Gases and Pressure Key Terms pressure millimeters of mercury partial pressure newton atmosphere of pressure Dalton s law of partial pressures barometer pascal In the chapter States of Matter, you read

More information

Moving Fluids Concept and Theory

Moving Fluids Concept and Theory Moving Fluids Concept and Theory Graco, Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 1995 Graco Inc. Form No. 321-037 12/95 Rev 2 SL Training 11/14 Understanding Your Customer s Situation Characteristics

More information

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS 2561762B REV. B 210 Printed in U.S.A. INSTALLATION AND SERVICE INSTRUCTIONS

More information

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY

More information

4 ANGLE GRINDER MODEL NO: CAT 52 PART

4 ANGLE GRINDER MODEL NO: CAT 52 PART 4 ANGLE GRINDER 4 ANGLE GRINDER MODEL NO: CAT 52 PART No: 3110685 OPERATION & MAINTENANCE INSTRUCTIONS 0807 Fig.1 SPECIFICATIONS Model:...CAG52 Part Number:...3110685 Rated Wheel...Capacity: 4 x 1/4 (type

More information

Owner s Manual for Assembly, Operating & Maintenance of

Owner s Manual for Assembly, Operating & Maintenance of Owner s Manual for Assembly, Operating & Maintenance of Model ST-1 Table Top Steam Table www.bigjohngrills.com YOU MUST READ THIS OWNER S MANUAL BEFORE OPERATING YOUR GAS STEAM TABLE. IF YOU SMELL GAS:

More information

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005 RDK-408D2 Cold Head Technical Manual SHI-APD Cryogenics Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision A: September 2005 (Reference SHI Manual: December 18, 2003 266404A CD32ZZ-160A)

More information

Mass Spec will not Autotune

Mass Spec will not Autotune Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems

More information

Setting up and running a column

Setting up and running a column Setting up and running a column PART 1: What you need and theory PART 2: Using a bellow and packing the column PART 3: Loading sample to silica PART 4: Running column PART 5: TLC analysis and combining

More information

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels 12.09 product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels Introduction: This manual covers the installation and operation of Humboldt FlexPanels for Triaxial and Permeability

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information