Annex (A) List and technical specifications of items

Size: px
Start display at page:

Download "Annex (A) List and technical specifications of items"

Transcription

1 Annex (A) List and technical specifications of items Item LOT# A) ICU Bed LOT A B) Monitoring system LOT A C) Defibrillator LOT A D) Shower Trolley LOT A E) Crash Cart LOT A F) Portable Ventilator LOT A G) Incubators (Neonate) LOT B H) Pediatric Ventilators (Neonate) LOT B I) Haemodialysis LOT C J) Portable X-ray LOT D K) Ultrasound LOT E Attached are the minimum specifications required for each I

2 A) Technical specifications of ICU Bed F u r n i t u r e S p e c i f i c a t i o n S h e e t Furniture Name Typical Photo Suppliers BED, CRITICAL CARE Page Code Qty. Of Purpose: No. Description/Spec C* P* Electric four section I.C.U BED ( FULL FOWLER). y/n 2 Backrest angulation 0-70 degrees. 3 Mobile on 4 large and wide electrically conductive casters with breaks. 4 Comes complete with mattress, washable mattress cover, straps & side rails. 5 Foot board with retractable board. 6 Up-down range: cm (approximately). 7 One button for retuning the bed for fully supine position for emergencies. 8 Bed length not less than 200 cm, Width not less than 85 cm 9 Electrically adjustable height, back, knee, foot and Trend/ Reverse 0 One button Dining chair position Original battery backup 2 Central brake and steer 3 Integrated controls at side rails with one independent 4 Angle indicator for Head and Trend/Reverse 5 Nonmoving head and foot during bed tilting 6 Built-in IV poles can be located in four locations 7 Emergency CPR 8 Trend/Reverse 2 / 2 9 Casters not less than 5 cm 20 Safe working load not less than 200Kg 2 High density foam mattress. 22 Built in Scale accuracy.% of patient weight 23 Bed Exit alarm- single mode ( included in scale) 24 low power Dc motor 25 Radiolucent sections 26 Night light under the bed 27 Please state any added accessories not mentioned

3 B) Technical specifications of MONITORING SYSTEM E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Suppliers PHYSIOLOGIC MONITORING SYSTEM, ACUTE CARE (VITAL SIGNS) Page Code Qty. Of Purpose: No. Description/Spec C* P* Wall-mounted patient monitor y/n 2 High resolution color LCD display of at least 5 " size. 3 Simultaneous display of at least 6 waveforms (channels): Modular or Semi modular or multi connector 4 ECG (3-channel, 2-lead), Temperature, NIBP, respiration, SPO2 5 ECG arrhythmia and ST segment analysis. HR display 6 SPO2: % - 99%, temperature: C, HR:30 250, respiration: 5-50 BPM 7 NIBP: mmhg 8 Events summary every 24 hours with full annotations and printout. 9 Comes complete with all cables, electrodes, etc. 0 Storage: flash memory to store at least 000 patients' records. Alarms: out of range (user-defined), ECG abnormalities, loose electrodes. 2 Automatic nurse call in case of alarms. 3 Battery backup for at least hour 4 Electrosurgery& defibrillator protection 5 Orignal one full set of accessories such as electrodes, cables, etc. (reusable) 6 A set of disposable ECG electrodes (00). 7 Orignal Mounting bracket, shelf and attachments for securing monitor in place 8 Wireless connection to the central station. 9 Memory and trend display of 24 hr recording 20 Bedside-to-bedside monitor communication 2 Option Modules(CO,2IBP,BIS,ETCO2)

4 C) Technical specifications of DEFIBRILLATOR E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Suppliers DEFIBRILLATOR/MONITOR WITH PACING Page Code Qty. of Purpose: Delivery of a very short high-energy shock wave (externally or internally) to defibrillate the infant heart. No. Description/Spec C* P* System consists of a defibrillator, pacer, and a 3-channel ECG (3 in ). y/n 2 Defibrillator Specifications (adult and pediatric use): 3 () Biphasic (2) Delivers up to 200 J (3 Max period before a second shock can be delivered: less than 8 seconds. (4) Cardioversion (synchronized defibrillation) within 20 msec of QRS complex. (5) Test mode to test charging and discharging. (6) Built-in shock advisory. (7) External & internal paddles (adult and pediatric) 4 Other Specifications: 5 () LCD or CRT display, at least 6" large (diagonally). (2) 3- channel ECG and HR. (3) Memory saves 0 minutes before and after defibrillation 6 Battery Specifications: (at 30 C) 7 () Able to supply at least 20 charges at maximum energy. (2) Requires at most 6 hours to recharge fully or at least 30 minutes operation (3) Battery status indicator. 8 Built-in thermal printer (or equivalent): 9 () Prints any ECG segment. (2) Annotation of patient data. (3) Automatic printing of the last 5 seconds of ECG prior to shock. 0 External Pacemaker Pacer Specifications: 2 () Modes: Fix, demand and over-pace. (2) Variable pulse rate and pulse shape. 3 Power-on self-test and self-diagnostics. 4 Portable light weight easy to use unit with a carrying handle. 5 AED mode 6 Charging using the paddles buttons and the main unit 7 Discharging using the paddles buttons two paddles simultaneously 8 ECG Monitor 9 NIBP, SpO2, EtCO2 20 ECG acquisition through Paddles or ECG electrodes 2 Trend 22 Alarms(Visual and audible for vital parameters, Lead off indicator, Malfunction messages) 23 Card memory 24 Original trolley

5 D) Technical specifications of SHOWER TROLLEY E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Supplier SHOWER,TROLLEY, PORTABLE, ADULT Page Code Qty. Of Purpose: No. Description/Spec C* P* Mobile chair suitable for use as commode, shower or sanitary chair. y/n 2 Four large break castors. 3 Plastic leg rests. 4 Plastic seat and high backrest 5 Safety strap. 6 Arm rests. 7 Height adjustment 8 Patient weight up to 40 kg 9 Comes with all accessories 0 Reclined mode Emergency stop 2 Construction made of aluminum or equivalent 3 Surface easy to clean 4 Chemical and mineral resistance 5 Anti rust

6 E) Technical specifications of Crash Cart E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Supplier CART, CRASH Page Code Qty. Of Purpose: Supports life-saving equipment for emergencies. No. Description/Spec C* P* Mobile cart on 4 wide Anti-static casters with breaks. y/n 2 At least 6 easily retractable lockable drawers: 3 at 25 cm high & 3 at 0 cm high approximately 3 Top (with two handles) supports a generic 5" monitor or better and a defibrillator. 4 Material: double steel sheets with baked-on enamel. 5 Comes with the following accessories: 6 () Oxygen cylinder (E type) on the side of cart. 7 (2) Endotracheal tubes (adult and pediatric) 9 (4) Laryngoscope set. (6) Ambu bags, different sizes. 2 (7) O2 face masks 3 (8) Nasal cannulae (different sizes). 5 (0) Needles, syringes, first aid kit, IV pole and IV solutions. 6 () Sharps container 7 Washable 8 Color choice according to owner

7 F) Technical specifications of Portable Ventilator E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Suppliers VENTILATOR, PORTABLE Page Code Qty. Of Purpose: Adult/pediatric automatic ventilation in intensive & intermediate care. No. Description/Spec C* P* Transport-type ventilator with built-in Air source. 2 Dual power: Mains 220V and rechargeable battery. 3 Power-on self-test. 4 LCD display (at least 2") of all respiratory parameters and waveforms. 5 Battery can support ventilation for at least two 35 C. 6 System consists of the following: 7 Choice of pressure or volume cycled. 8 Allows for the following modes: CPAP, PEEP, SIMV, Assist Control, Volume Control, Pressure Control, Apnea back up 9 Pressure limiting. 0 Alarms: out-of-range flow/pressure/volume/bpm/battery low/equipment diagnostics. All necessary cables, breathing circuits and connectors sets of disposable breathing circuits & 2 sets of reusable BC. 3 Mobile cart

8 G) Technical specifications of Incubators, Neonate Incubators, Vendor/Manufacturer: Neonate, Model: Mobile Origin: (NICU) (With Scale) Technical Specification Main Features Provides a closed, servo controlled environment that warms an infant by circulating heated air over the skin. 2 Application Area Neonatal Intensive care unit (NICU) 2 Control Microprocessor Control Yes 2 Temperature Control Air range, C (increments): (0.)* 2 Skin, C (increments): (0.)* 3 O 2 Servo Control Yes 4 Humidity Servo Control Please state the range 5 Other specification without increasing in price Please state 3 Display Display Type LCD or higher technology 2 Temperature display Air, display type Digital 2 Air, Range, C * 3 Skin, display type Digital 4 Skin,Range, C * 3 Heat Power indicator Yes 4 Alarms Type Audible Alarm & Visible indication 2 Alarm Parameters High Air Temp & Low Air Yes Temp 2 High Skin Temp & Low Skin Yes Temp 3 Air Flow failure Yes 4 Sensor(s) failure Yes 5 Power failure Yes P a g e 2

9 5 HOOD Material Original Clear Yes 2 Antibacterial Yes 3 Cleaning & Disinfection Please state 2 Hand Ports At least 4 * 3 Tubing Ports At least 4 * 4 Double Wall Yes 5 Size, cm Please state, the bigger the better * 6 Bed & Mattress Easy cleaning & disinfection Yes 2 Radiolucent Yes 3 Size, cm At least 60 x30 * 4 Bed tilting Please state 7 General features Backup thermostat Yes 2 Internal Noise, Db <58 ( the lower the better) 3 Power requirements Line Power Hz,single phase 4 O 2 Inlet Ports At least 5 X-ray facility Yes 6 Air Filtration Yes 7 Key Look Yes 8 Built in digital scale Yes 8 Body & Stand Material Original (Non-corrosive) 2 Shelves Please state 3 Drawers Please state 4 IV Pole At least 5 Castors Original Conductive, Non-corrosive & Equipped with brakes *This is the least required range & any higher range is accepted P a g e 2 2

10 H) Technical specifications of Ventilators, Neonate Ventilators, Intensive Care, Neonate Vendor/Manufacturer: Model: Origin: Technical Specification PATIENT TYPE : NEONATE 2 Display Type LCD, Built-in 2 Size, in 6 3 Data displayed Numeric, Waveforms, Trends 3 Controls Tidal volume, ml 5-00* 2 Inspiratory flow, L/min 4-20* 3 Respiratory rate, 5-20* breaths/min 4 Inspiratory time, sec 0.2-2* 5 Expiratory time,sec * 6 FiO 2, % 2-00 * 7 PIP, cm H 2o 5-70 * 8 PEEP, cm H 2o 0-24 * 9 Base flow, ml/min 2-20 * 0 Leak compensation Yes Tube compensation Yes 2 Manual Breath Yes 3 Control Panel Lock Yes 4 Operating modes at pressure control A/C ( Assist/Control) Yes 2 SIMV ( Synchronized Yes Intermittent Mandatory Ventilation) 3 Time cycled Pressure Yes Limited 4 PSV ( Pressure Support Yes Ventilation) 5 Apnea-backup vent Yes 6 Volume Guarantee Yes 7 Non-invasive ventilation Yes, State the modes 5 Monitored Parameters PIP (Peak Inspiratory pressure) Yes 2 MAP ( Mean airway Yes pressure) 3 PEEP ( Positive end Yes expiratory pressure) 4 Tidal Volume Yes P a g e 3

11 Ventilators, Intensive Care, Neonate Vendor/Manufacturer: Model: Origin: Technical Specification 5 Monitored parameters continued 5 FI0 2 Yes 6 Respiratory rate Yes 7 Inspiratory time Yes 8 IE Yes 9 Lung mechanisms Please state 6 Alarms ( Audiable or Visual) Equipment alarms Gas-supply failure Yes 2 Power Failure Yes 3 Ventilator Yes inoperative 4 Low battery Yes 2 Patient alarms High respiratory Yes rate 2 High PEEP Yes 3 Low PEEP Yes 4 High PIP Yes 5 Low PIP Yes 6 High Pressure/ Yes Occlusion 7 FiO 2 Yes 8 Breathing circuit disconnect Yes 7 Self-Diagnostic 8 NEBULIZER (preferred ultrasonic built in- Ultrasonic external synchronized- Pneumatical Built in) 9 HUMIDIFIER ( servo control) 0 Power Requirements LINE POWER 220 VAC, 50Hz, Single-phase 2 Battery Operating time, hr Rechargeable Yes Accessories Mask Neonate, Qty 0 2 Test Lung Neonate, Qty 2 P a g e 2 3

12 Ventilators, Intensive Care, Neonate Technical Specification 3 Inspiration & Expiration Filter Accessories continued 4 Patient circuits Material Antistatic 2 Reusable & Autoclavable & Silicon Yes Vendor/Manufacturer: Model: Origin: Yes, Please state type (Autoclavable preferred, state no. of sterilization cycles) 3 Quantity 2 5 Medical grade Air compressor : With automatic switchover & compatible with hospital gas pipe system 6 Gas supply hoses for air & oxygen with connectors as hospital standard outlet 2 The ventilator machine shall be mobile on conductive & swivel castors with locks and side arms original 3 Flow sensor (Preferred Permanent-Reusable Sterilizable ( Autoclave-Plasma) at Y Piece 4 The ventilator machine shall be easy to be cleaned and disinfected *This is the least required range & any higher range is accepted. P a g e 3 3

13 I) Technical specifications of Haemodialysis Minimum Required Specifications High performance Haemodialysis Machine. Easy for use to ensure maximum safety for patient Volumetric ultra-filtration control Designed for heat and chemical disinfection Designed to use all filters and consumables (blood lines,.) available in local market Operate with acetate and bicarbonate dialysis (Cartridge and powder) Back up battery to maintain continues blood circulation during electrical power failure for at least 5 minutes. Only well-known brand names in the field will be accepted Equipped with heparin pump The machine should be disinfected by disinfectant solutions available in local market with no restrictions or special disinfectant need. Profiling for UF (NA Profile), Bicarbonate profile, dialysate flow Equipped with ultra-pure filter for dialysate Dialysate temperature control KT/V display by measurement Dialysate flow rate display ML/MIN up to 800 Availability to be connect the machine to Hospital Information system.(option) Temperature alarm limits. C Alarm if temperature exceed: Conductivity range MS/CM: 3-5 Transmembrane Pressure MM HG Alarm Bypass indicator Blood circuit Blood pump range ml/min Display type : digital or led indicator Displayed parameters Dialysate pressure : Preferred Transmembrane pressure Conductivity Flow rate : Yes Elapsed time: Yes Alarm Action Blood- leak detector: yes (stop blood pump, clamps, venous return, etc.) Air foam detector: yes (stop blood pump, clamps, venous return, etc.) Arterial/venous pressure: -200/400(Arterial) 00/+400 (Venous) (stop blood pump, clamps, venous return, etc.) Temperature High/Low : Yes (Dialyzer bypass) Power requirement: 220 VAC, 50 HZ- Single phase.

14 J) Technical specifications of Portable X-ray E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Suppliers Analogue Mobile x-ray (AC & Battery) Page Code Qty. Of Purpose: Delivery of aerosolized medications to treat respiratory disorders No. Description/Spec C* P* Generator: y/n 2 Microprocessor control, High Frequency inverter type 3 Digital displays of mas, kv and an electronic timer 4 Kw 30 5 Kv 40-25, Adjustable 6 ma range 200 ma 7 Touch key operations 8 Shortest exposure time: ms 9 Anatomical Programmable Radiographic modes 0 Tube: Rotating Anode 2 Anode heat capacity 300 khu (20 KJ) 3 Anode heat dissipation 667 HU/s (475 W) 4 Tube housing heat capacity 250 khu (900 KJ) 5 RPM Dual Focus 7 Collimator rotation -/+90 8 Articulated arm for maximum positioning flexibility in any patient position 9 The unit have cassette storage facility for all size of cassettes 20 ACCESSORIES 2 2 Lead Approns, 4" X 7" cassette 22 POWER REQUIREMENTS 23 Power input to be 220 VAC, 50Hz 24 Batteries, with low charging time and low-battery indicator 25 General Conditions (Must be Documented) 26 FDA 27 CE or any equivalent certificate 28 IEC, ISO, or any equivalent certificate 29 Country of origin of Company 30 Country of origin of Equipment

15 K) Technical specifications of Ultrasound E q u i p m e n t S p e c i f i c a t i o n S h e e t Equipment Name Typical Photo Suppliers Echo Ultrasound +convex (ICU) (Portable System) Page Code Qty. Of Purpose: Delivery of aerosolized medications to treat respiratory disorders No. Description/Spec C* P* Technical Specifications : y/n 2 Portable System (Laptop Style with security locks on a light weight trolly) should have following Applications with extensive Calculation software : 3 Applications: ICU, Emergency Medicine, Cardiology 4 Abdomen 5 Vascular - transcranial - small parts 6 Endo-cavitary application- Trans-vaginal 7 System will have following Modes : 8 M-Mode, Color M-Mode, PW Doppler 9 HPRF Doppler, CW Doppler 0 Steerable Doppler, Power Doppler, Color Flow Mapping Color Angio Visualization, and Directional power Doppler 2 Duplex and Triplex Mode simultaneity (all three modes 2D, Color & Doppler Modes simultaneously). 3 Scan depth will be 30 cm or more 4 System should have at least 3 active ports 5 LCD/TFT HD monitor 5'' or more 6 Archiving database management system allows the storing on CD/DVD and review of images and loops to be processed later the same as online and take offline measurements 7 Offline analysis and processing allowing the user to change the following settings offline: 8 2D gain, Grey scale maps, Zooming, 2D image processing, 2D measurements 9 Color gain, color maps 20 M mode gain, M mode measurements 2 Doppler gain, Baseline, Velocity Scale, Doppler maps, All Doppler measurements 22 Dual &/ Quad split display 23 Anatomical M Mode 24 Automatic Tissue Optimization 25 Automatic Spectral Doppler Optimization 26 Have Duplex for simultaneous B mode & Spectral Doppler and real time triplex mode 27 Facility of Full screen imaging 28 Facility for zoom (real-time and frozen image) 29 Cineloop review facility in individual and mixed modes with memory up to minimum of 380 MB 30 System have Controls for Time Gain Compensation (TGC - slide pot control), variable power, dynamic range & overall gain control so that following parameters can be adjusted on stored / live image.- Gain, TGC, Dynamic range, Gray map, Color map 3 Showing blood flow in 2D mode 32 Frame Rate not less than 200 F/S 33 at least 260 db Dynamic Range 34 Pan Zoom feature for real time & frozen images

16 35 Needle Recognition Includes ability to adjust needle gain and angle. 36 Automatic calculation in PW Doppler. 37 Built-in hard disk with memory of minimum 500 GB. 38 Image archival & Transfer 39 measurements in all applications 40 Full DICOM 3 package with Life time license 4 System must have fast boot-up time 42 Higher gray scale will be evaluated 43 Minimum weight with Battery 44 Battery with longest operation time 45 CW KIT 46 Supplied Probes : 47 Convex Array Transducer up to 5 MHz 48 Linear Array Transducer up to 3 MHz 49 Phased array Transducer ( MHz) 50 User friendly software: 5 Accessories: 52 B/W Video Printer 53 UPS for 0 minute 54 Power input to be 220 VAC, 50Hz 55 Standards and Safety Requirements 56 FDA,CE mark, IEC

Technical Data and Specifications

Technical Data and Specifications Technical Data and Specifications INTENDED USE Ventilator designed to provide Invasive and Non-invasive ventilation for the critical care management of adult, pediatric and neonate-infant (including premature)

More information

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES DATA ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES CRITICAL CARE HIGHLIGHTS! For all patient categories, from neonate and pediatric to adult! A platform for the future choose the level of system

More information

Electronics Respironics Lifecare PLV-102 / PLV-102 Ventilator To t a l S o l u t i o n This lightweight ventilator is well suited for transport and portable applications. Controlled by a microprocessor,

More information

DATA SHEET. VENTILATION SERVO-s

DATA SHEET. VENTILATION SERVO-s DATA SHEET VENTILATION The Gold Standard Critical Care 3 PROVEN SERVO SIMPLICITY, RELIABILITY AND SENSITIVITY MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical

More information

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters SLE4000 Infant Ventilator with touch-screen operation When the smallest thing matters SLE4000 - The Total Solution for Conventional Infant Ventilation SLE is a world leader in the design and manufacture

More information

INTENSIVE CARE VENTILATORS

INTENSIVE CARE VENTILATORS INTENSIVE CARE VENTILATORS iternis ADV INTENSIVE CARE VENTILATION FOR ALL PATIENT CATEGORIES Design Features HEYER iternis ADV s 12-inch touch-screen display combines comprehensive, easy-to-follow user

More information

NEONATAL/INFANT VENTILATOR

NEONATAL/INFANT VENTILATOR n a!! i le ion b a a i l ve r s v w a lone o N d-a n sta FEATURES: MDES F VENTILATIN PRESSURE LIMITED/ CNTINUUS FLW FLW TRIGGERED VLUME VENTILATIN NENATAL/INFANT VENTILATR The Crossvent 2i+ ventilator

More information

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products

More information

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products Saturn Evo SATURN EVO COLOR A N A E S T H E S I A S Y S T E M i n t e l l i g e n t s i m p l i c i t y Manufacturer of high quality anaesthesia products SATURN EVO COLOR PATIENT SAFETY AND USER PATIENT

More information

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR: PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: 1. **Identify and name the filters on the 7200ae. 2. **Explain how each filter is sterilized. 3. **Trace the gas flow through the ventilator

More information

fabian HFO: Modular, Powerful, Versatile.

fabian HFO: Modular, Powerful, Versatile. fabian HFO: Modular, Powerful, Versatile. Introducing the flagship of the ACUTRONIC FABIAN FAMILY. The FABIAN HFO, a ventilator developed specifically for the NICU and PICU needs, packed with many great

More information

Airox Supportair Ventilator

Airox Supportair Ventilator Airox Supportair Ventilator A versatile hospital ventilator with a titration platform that enables a smooth transition to the patient s home care ventilator Titration Platform The Supportair ventilator

More information

IEC C LASSIFICATIONS:

IEC C LASSIFICATIONS: Enrich life Introducing Astral Introducing the Astral 100 and Astral 150 life support ventilators. From initial setup to everyday use, Astral offers greater freedom, confident care and designed efficiency

More information

Milestones of Aeonmed Ventilators

Milestones of Aeonmed Ventilators Aeonmed Development History Milestones of Aeonmed s 2003 More than 1000 Aeonmed ventilators contributed to save lives during SARS 2008 Aeonmed nominated emergency ventilator supplier for 2008 Beijing Olympic

More information

Panther 5 Acute Care Ventilator

Panther 5 Acute Care Ventilator 1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without

More information

Aespire 7100 Essential performance Compact design

Aespire 7100 Essential performance Compact design GE Healthcare Aespire 7100 Essential performance Compact design Features Enhanced monitor integration capabilities with our Datex-Ohmeda Anesthesia Monitor and Compact Anesthesia monitor Lightweight and

More information

A9600 Anesthesia Workstation. Your healthcare, we care.

A9600 Anesthesia Workstation. Your healthcare, we care. A9600 Anesthesia Workstation Your healthcare, we care. A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation.

More information

State-of-the-art anesthesia technology

State-of-the-art anesthesia technology State-of-the-art anesthesia technology anesthesia system Get closer to the MRI scanner Superb certified performance in close proximity to strong magnetic fields. Our innovative machine provides benefits

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus Your requirements for reliability and mobility are our benchmark. VENTIlogic LS and VENTIlogic plus

More information

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation Ventilation EVE easy - light - smart The mobile Ventilation Concept from Emergency to Intensive Care + Ventilation at the push of a button + Cutting edge turbine technology + Critical care during transport

More information

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes O-Two Self-Study Guide e600 Transport Ventilator Ventilation Modes e600 VENTILATION MODES The e600 ventilator has 13 ventilation modes: Manual Ventilation, Controlled Mandatory Ventilation (CMV), Assist

More information

Amended Technical Specifications BLOOD GAS ANALYZER

Amended Technical Specifications BLOOD GAS ANALYZER BLOOD GAS ANALYZER 1. It should measure Blood Gas (full parameters) in its addition to measure Electrolytes like Na+, K+, Cl-, ph, po2,pco2. and Haematocrit. 2. Calculated parameters: TCO2, HCO3, Base

More information

Operation and Maintenance of the EPV200 Portable Ventilator

Operation and Maintenance of the EPV200 Portable Ventilator Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide

More information

SLE5000 Infant Ventilator with HFO

SLE5000 Infant Ventilator with HFO SLE5000 Infant Ventilator with HFO When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation Shown on optional roll stand. Ventilator may be mounted either way round on stand.

More information

No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014

No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014 No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR 1. EQ-C-66 Bubble C PAP 2. EQ-C-68 Neonatal High frequency ventilator 3. EQ-C-70

More information

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15 AED A5 Mediana Automated External Defibrillator A5 AED A5 COVER Protected icon sheet, shock button, adult/paediatric mode switch. 7 BATTERY Disposable LiMnO2 Non-Rechargeable. 2yrs shelf life, 5yrs standby

More information

SLE5000 Neonatal Ventilator with High Frequency Oscillation

SLE5000 Neonatal Ventilator with High Frequency Oscillation SLE5000 Neonatal Ventilator with High Frequency Oscillation The SLE5000 is superb: the best High Frequency Ventilator I ve used When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation

More information

fabian Therapy evolution Our 2-in-1 device

fabian Therapy evolution Our 2-in-1 device fabian Therapy evolution Our 2-in-1 device Ventilation Beyond Limits When It Comes to Life, There Is No Compromise Distributing worldwide ACUTRONIC is a privately held company that develops, manufactures,

More information

V8800 Ventilator System. Your healthcare, we care.

V8800 Ventilator System. Your healthcare, we care. V8800 Ventilator System Your healthcare, we care. V8800 Ventilator System V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design,

More information

Automatic Transport Ventilator

Automatic Transport Ventilator Automatic Transport Ventilator David M. Landsberg, MD, FACP, FCCP, EMT-P Luke J. Gasowski, RRT, NPS, ACCS, CCP-C, FP-C Christopher J. Fullagar, MD, FACEP, EMT-P Stan Goettel, MS, EMT-P Author credits /

More information

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Introducing Astral. Greater freedom. Confident care. Designed efficiency Enrich life Introducing Astral From initial setup to everyday use, the Astral 100 and Astral 150 life support ventilators offer greater freedom, confident care and designed efficiency to enrich life for

More information

Ventilator Training Module

Ventilator Training Module Ventilator Training Module LTV (Lap Top Ventilator) Teaching Script LTV User guides: http://www.carefusion.com/documents/guides/user-guides/rc_ltv-1000_ug_en.pdf http://www.carefusion.com/documents/guides/user-guides/rc_ltv-1100_ug_en.pdf

More information

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator 1 Applications of the MCV100(B) The MCV100 and MCV100-B Mass Casualty Ventilators are electronically controlled portable ventilators,

More information

APUS Anesthesia Machines

APUS Anesthesia Machines APUS Anesthesia Machines Adult and pediatrics applicable breathing circuit Autoclavable metal and plastic materials. Featured with stable pressuretightness. Visual observation of bellows and valves. Breathing

More information

Safe Accurate Reliable. CWM-301 Anesthesia System

Safe Accurate Reliable. CWM-301 Anesthesia System Safe Accurate Reliable CWM-301 Anesthesia System CWM-301 Anesthesia System Extraordinary performance points 8.4 inch colour LCD screen Compact Anesthesia ventilation system with the standard of ISO 9001:13485

More information

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare patient education program 4156 South 52 nd Street, Omaha, NE 68117 800-747-7334 402-734-6741 ChildrensOmaha.org/HomeHealthcare We know children CHILDREN S HOME HEALTHCARE Trilogy Ventilator Instructions

More information

APUS Anesthesia Machines

APUS Anesthesia Machines APUS Anesthesia Machines APUS x1 Anesthesia Machine Breathing circuit applicable for complete range Autoclavable metal and plastic materials. Suitable for adult, pediatric and neonatal patients. Featured

More information

How Ventilators Work. Chapter 3

How Ventilators Work. Chapter 3 How Ventilators Work Chapter 3 To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts with the patient How changes in lung condition

More information

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator IMPACT Uni-Vent Eagle Model 754 Portable Ventilator Uni-Vent Eagle Model 754 Portable Ventilator OPERATOR TRAINING PROGRAM FOR: Critical Care Transport Aero medicine Emergency Services Uni-Vent Eagle Model

More information

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Narkomed MRI-2 A perfect fit for the MRI environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care The complete anesthesia solution for the MRI environment A

More information

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017) e700 Automatic Transport Ventilator User Manual Table of Contents Chapter 1 Safety... 1 Chapter 2 Intended Use.. 4 Chapter 3 Overview.... 5 3.1 Control and Display Layout...... 5 3.2 Function Keys......

More information

fabian HFO Our 4-in-1 device

fabian HFO Our 4-in-1 device fabian HFO Our 4-in-1 device Ventilation Beyond Limits When It Comes to Life, There Is No Compromise Distributing worldwide ACUTRONIC is a privately held company that develops, manufactures, and distributes

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic VENTIlog LS Your Requirements for Reliability and Mobility are Our Benchmark. VENTIlogic LS and VENTIlogic plus are

More information

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations GE Healthcare Centiva/5 Critical Care Ventilator Meet a new level of expectations Intergrating performance and value Marry form and function In an environment where time and space are tight, the design

More information

WILAmed INTENSA. Intensive Care Ventilator System

WILAmed INTENSA. Intensive Care Ventilator System EN WILAmed INTENSA Intensive Care Ventilator System 0197 WILAmed INTENSA Ventilator System The WILAmed INTENSA is a full invasive and non-invasive life-support ventilator, solely designed for the ventilation

More information

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do 8/25/11 Mechanical ven3la3on Neonatal Mechanical Ven3la3on Support oxygen delivery, CO2 elimination" Prevent added injury, decrease ongoing injury" Enhance normal development" Mark C Mammel, MD University

More information

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated Bunnell Incorporated n www.bunl.com n 800-800-4358 (HFJV) n info@bunl.com 436 Lawndale Drive n Salt Lake City, Utah 84115 n intl 801-467-0800 n f 801-467-0867 Bunnell LifePulse HFV Quick Reference Guide

More information

HAMILTON-G5. The modular high-end ventilation solution

HAMILTON-G5. The modular high-end ventilation solution HAMILTON-G5 The modular high-end ventilation solution We live for ventilation technology We live for ventilation technology. Technology that helps caregivers improve the lives of their critically ill patients.

More information

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals a The Ventilation Standard for Professionals a The Ventilation Standard for Professionals a offers you everything you need for reliable emergency ventilation. Users around the world are impressed by its

More information

GE Healthcare. Aestiva/5. More than superior ventilation

GE Healthcare. Aestiva/5. More than superior ventilation GE Healthcare Aestiva/5 More than superior ventilation A balance of superior ventilation and award-winning design SmartVent the shape of superior ventilation At the heart of the Datex-Ohmeda Aestiva /5

More information

SERVO-s v8.0 Data sheet

SERVO-s v8.0 Data sheet Data sheet This document is intended to provide information to an international audience outside of the US. 2 Critical Care Key features For adult and pediatric patients A ventilator system designed to

More information

Department of Paediatrics

Department of Paediatrics KASTURBA HEALTH SOCIETY'S MAHATMA GANDHI INSTITUTE OF MEDICAL SCIENCES, P.O. SEVAGRAM, WARDHA (DISTT.) MAHARASHTRA STATE - 442 102 Specifications for Equipment Department of Paediatrics 1. A) Ventilator

More information

Intensa GO Alternate Care Ventilator

Intensa GO Alternate Care Ventilator EN Intensa GO Alternate Care Ventilator 0197 Intensa GO Versatility and simplicity The all new WILAmed Ventilator INTENSA Go offers great versatility and simplicity. It is designed to ventilate (invasive

More information

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017)

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017) e600 Automatic Transport Ventilator User Manual Table of Contents Chapter 1 Safety. 1 Chapter 2 Intended Use.. 4 Chapter 3 Overview. 5 3.1 Control and Display Layout........ 5 3.2 Function Keys......

More information

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485 ANESTHESIA MACHINES AUGUST - 2008 MEDICAL PRODUCTS ANESTHESIA MACHINES Quality System Standard applied: ISO 9001, ISO 13485 CE Certification 93/42/EEC. Arsiconsult 38, Av. Guy de Maupassant 78400 Chatou

More information

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter ESSE 3 Via Garibaldi 30 14022Castelnuovo D.B. (AT) tel +39 011 99 27 706 fax +39 011 99 27 506 e-mail esse3@chierinet.it web : www.4ci.com PERSEO EVOLUTION workstation for gaseous anaesthesia for adults,

More information

MANITOBA RENAL PROGRAM

MANITOBA RENAL PROGRAM MANITOBA RENAL PROGRAM SUBJECT Fresenius 5008 Preparation for Hemodialysis using the ONLINEplus System SECTION CODE 30.10.02 30.10 Hemodialysis: Equipment and Procedures AUTHORIZATION Professional Advisory

More information

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Your patients, our primary focus. Siesta i Whispa anesthesia machine Your patients, our primary focus Siesta i Whispa anesthesia machine Functional, and flexible At Dameca we are not just committed to meeting the healthcare needs of today. We also think about tomorrow.

More information

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation V8600 Ventilator Integrated Invasive & Noninvasive Ventilation 0123 V8600 Ventilator Invasive Ventilation With state-of-the-art turbine technology, V8600 helps achieve sequential ventilation in various

More information

Inspiration 7i Ventilator

Inspiration 7i Ventilator Inspiration 7i Ventilator Clinician Focused Products is not just a tag line, rather a belief system. Low cost of ownership High performance PSOL and active exhalation Comprehensive graphics and trending

More information

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS INTENDED USE The GraphNet ts ventilator was designed to be used with all types of patients: adult, pediatric, and neonatal infants (optionally with the NEO-INF module) requiring invasive and noninvasive

More information

Anesthesia Workstation

Anesthesia Workstation Your healthcare, we care. A9800 Anesthesia Workstation Technical Parameters A9800 Ventilation Modes Alarms Volume Control Pressure Control SIMV with Pressure Support (SIMV + PS) - with Volume or Pressure-type

More information

e500 Automatic Transport Ventilator User Manual e500 User Manual (15PL Rev.7 6_6_2017)

e500 Automatic Transport Ventilator User Manual e500 User Manual (15PL Rev.7 6_6_2017) e500 Automatic Transport Ventilator User Manual Table of Contents Chapter 1 Safety.. 1 Chapter 2 Intended Use 4 Chapter 3 Overview.. 5 3.1 Control and Display Layout.... 5 3.2 Function Keys..... 6 3.2.1

More information

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open. Calibration Procedures on Cobe Centrysystem 3: I) Balance Chamber Calibration: - Verify that pressure regulators PRV and PRV2 are calibrated as well as pressure transducers PDI and PDO with switches SW2

More information

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life Anesthesia Solutions The Future of Anesthesia Prima SP and Prima SP2 Anesthesia Systems The Penlon Anesthesia System Range provides the user with their choice of advanced, easy to use anesthesia systems

More information

Oxylog 3000 plus Emergency & Transport Ventilation

Oxylog 3000 plus Emergency & Transport Ventilation Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow, integrated capnography and non-invasive Ventilation, the compact and robust Oxylog

More information

Flight Medical presents the F60

Flight Medical presents the F60 Flight Medical presents the F60 Reliable Ventilation Across the Spectrum of Care Adult & Pediatric Pressure/Volume Control Basic/Advanced Modes Invasive/NIV High Pressure/Low Flow O2 Up to 12 hours batteries

More information

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Traditional hospital ORs have their needs... With more surgical procedures being performed

More information

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Automatic Transport Ventilators. ICU Quality Ventilation on the Street. Automatic Transport Ventilators ICU Quality Ventilation on the Street. Kevin Bowden, March 20 th 2014 Ventilator Definition A ventilator is an automatic mechanical device designed to provide all or part

More information

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota ASSISTANCE Cardinal Health Pulmonetic Systems 17400 Medina Rd., Suite 100 Minneapolis, Minnesota 55447-1341 Customer Care: (800) 754-1914 (763) 398-8500 Fax: (763) 398-8403 Website: www.cardinalhealth.com/viasys

More information

Dameca MRI 508. State-of-the-art MRI technology

Dameca MRI 508. State-of-the-art MRI technology Dameca MRI 508 State-of-the-art MRI technology The closer, the safer the better Hospitals have long awaited an anaesthesia machine that can be used close to their MRI scanner. The Dameca MRI 508 is it

More information

DATA SHEET. VENTILATION SERVO-i INFANT HIGHLIGHTS

DATA SHEET. VENTILATION SERVO-i INFANT HIGHLIGHTS DATA SHEET VENTILATION HIGHLIGHTS For neonatal to pediatric patients Intuitive user interface Designed for cost-efficiency Flexible placement Modular - interchangeable plug-in units Enables Heliox delivery

More information

Puritan Bennett 840 Universal Ventilator

Puritan Bennett 840 Universal Ventilator Puritan Bennett 840 Universal Ventilator ne Ventilator for Every Area of Care Healthcare providers and patients throughout the world depend on Covidien for state-of-the-art ventilation therapy. Whether

More information

Mechanical Ventilation

Mechanical Ventilation Mechanical Ventilation Understanding Modes Rob Chatburn, RRT-NPS, FAARC Research Manager Respiratory Therapy Cleveland Clinic Associate Professor Case Western Reserve University 1 Overview Characteristics

More information

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH VENTILATION SERVO-i INSPIRATION IN EVERY BREATH The Gold Standard Critical Care SERVO-i 3 PROVIDING THE HIGHEST LEVEL OF CLINICAL CARE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international

More information

Emergency Transport and Ventilation

Emergency Transport and Ventilation Emergency Transport and Ventilation When you get a call and the patient is not breathing, are you and your equipment ready? Can you make the difference? Pneupac portable gas powered ventilators (PGPVs)

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you With the most advanced anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow

More information

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management Tourniquet System Ideal for single or bi-lateral orthopaedic surgery and pain management The AT4 Electronic Tourniquet: A state-of-the-art dual channel electronic tourniquet with integral power supply

More information

Hospital and Transport for Controlled Breathing

Hospital and Transport for Controlled Breathing Hospital and Transport for led Breathing When transporting a critically ill patient you need a ventilator that can go anywhere in any situation. Smiths Medical Pneupac small portable gas powered ventilators

More information

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland. HAMILTON-T1 Quick Guide This Quick Guide is intended as a useful reference for ventilation of adult and pediatric patients. It does not replace the clinical judgment of a physician or the content of the

More information

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP Devices - Masks - Accessories for respiratory assistance in HAROL is one of the Italian companies leader in developing and selling systems, determining the most appropriate solutions for all your needs.

More information

ila ACTIVVE SYSTEM PLATFORM

ila ACTIVVE SYSTEM PLATFORM ila ACTIVVE SYSTEM PLATFORM Custom-tailored Extrapulmonary Lung Support ila activve : Custom-Tailored Extrapulmonary gas exchange Extrapulmonary blood flow: as high as necessary as low as possible. The

More information

AUTOVENT 4000 VENTILATOR

AUTOVENT 4000 VENTILATOR OVERVIEW AUTOVENT 4000 Only properly trained and approved Escambia County Bureau of Public Safety Paramedics are to use the AutoVent 4000 ventilator manufactured by LSP to transport patients already on

More information

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Principles of mechanical ventilation Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Disclosure Research grant Chiesi Pharmaceuticals Research grant CareFusion GA: 27 weeks,

More information

Tourniquet Systems Pressure Infusion

Tourniquet Systems Pressure Infusion Tourniquet Systems Pressure Infusion VBM Medizintechnik GmbH VBM 1 VBM 2 Summary Tourniquets and Accessories Digital Tourniquets... Compressed Air Tourniquets... Electronic Tourniquets... Application Tourniquets...

More information

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING OPERATOR S MANUAL 0614-905493A First Edition: 12 Dec 2011 Second Edition: 12 Feb 2015 Printed: Pediatric/Infant cap-one Mask YG-232T/YG-242T Symbol Description Attention, consult operator s manual Date

More information

Infant Warmers Quality for life

Infant Warmers Quality for life Alhena Infant Warmers Quality for life Infant Warmers A basic requirement for therapy and treatment of newborns, and in particular Low Birth Weight newborns, is to have a temperature controlled environment.

More information

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT IV - 2013 MECHANICAL VENTILATORS Prof. Yasser Mostafa Kadah Mechanical Ventilator A ventilator is a machine, a system of related elements designed to alter, transmit, and direct energy

More information

Equipment and supplies - pediatric intensive care service.

Equipment and supplies - pediatric intensive care service. ACTION: Original DATE: 02/27/2017 9:54 AM 3701-84-64 Equipment and supplies - pediatric intensive care service. (A) Appropriate drugs for resuscitation and pediatric advanced life support shall be present

More information

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life D-9355-2009 Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM Dräger. Technology for Life 02 DRÄGER FABIUS GS PREMIUM One of the most challenging places D-9354-2009 on earth The modern hospital

More information

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors SiPAP Set-Up Plug into mains, air & O 2, then setup the circuit as shown below Set-up & test before spiking water bag A few seconds after turning on, the screen changes to Set Up Screen Before adjusting

More information

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services UNDERSTANDING NEONATAL WAVEFORM GRAPHICS Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services Disclosures Purpose: To enhance bedside staff s knowledge of ventilation and oxygenation

More information

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA SOP#: 1157.1 Date Issued: 05/14 Date Revised: 5/15 Page 1 of 6 TITLE: SCOPE: RESPONSIBILITY: PURPOSE: SurgiVet

More information

HAMILTON-MR1. Technical specifications HAMILTON-MR1

HAMILTON-MR1. Technical specifications HAMILTON-MR1 HAMILTONMR1 HAMILTONMR1 Technical specifications The HAMILTONMR1 guarantees uncompromised continuous ventilation care from the ICU to the MRI scanner and back. Its reliability and high performance, with

More information

Contacts. Quick Start Guide

Contacts. Quick Start Guide Contacts Clinical Support Specialist: Phone: Cell Phone: Email: Fresenius Renal Technologies A division of Fresenius Medical Care North America 920 Winter Street Waltham, MA 02451 Technical Service Customer

More information

SERVO-air ventilator. Datasheet for system version 2.1

SERVO-air ventilator. Datasheet for system version 2.1 SERV-air ventilator Datasheet for system version 2.1 This document is intended to provide information to an international audience outside of the US. Contents Technical specifications... 3 General... 3

More information

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults... First and Only Disposable Infant T-Piece Resuscitator In-Line PIP Controller New Override Button Easier to Read Manometer New PIP Controller with Override Button allows clinicians to reach higher pressures

More information

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command Changing patient from NIV to INVASIVE Vent Type Table 9 shows automatic settings changes that occur when changing the same patient from NIV to INVASIVE Vent Type. Table 9: Automatic settings changes NIV

More information

pneuton Transport Ventilator Model S Operators Manual The pneuton Ventilator is under US patent protection. (Patent # 6,591,835)

pneuton Transport Ventilator Model S Operators Manual   The pneuton Ventilator is under US patent protection. (Patent # 6,591,835) The pneuton Ventilator is under US patent protection. (Patent # 6,591,835) pneuton is a Registered Trademark of the Airon Corporation Copyright 2011 by Airon Corporation pneuton Transport Ventilator Model

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you The anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow sensors, allowing

More information